Displaying all 20 publications

Abstract:
Sort:
  1. Lim CC, Ahmad TEBTN, Sawali HB, Afandi ANB, Paniselvam V, Bernard MW, et al.
    Eur Arch Otorhinolaryngol, 2023 May;280(5):2201-2207.
    PMID: 36350365 DOI: 10.1007/s00405-022-07711-1
    OBJECTIVES: Obstructive sleep apnea (OSA) has been associated with auditory dysfunction both to the cochlear and higher auditory pathways. However, available literatures presented conflicting results. We aimed to study the impact of OSA severity and their polysomnography parameters on hearing function.

    MATERIALS AND METHODS: A total of 44 patients were included after evaluation for sleep disorders and were divided into four groups in accordance with apnea-hypopnea index (AHI). Pure tone audiometry (PTA), distortion product otoacoustic emission (DPOAE) and auditory brainstem response (ABR) were compared in commensurate with the severity of AHI. Polysomnography oximetry parameters of oxygen desaturation index, mean SPO2, minimum SPO2 and percent SPO2 

    Matched MeSH terms: Oximetry
  2. Kuan GL, Tee AC
    MyJurnal
    To study the role of pulse oximetry in the assessment of acute asthma in children presenting to the A&E department, 360 children who presented themselves to the A&E department were enrolled into the study. Those admitted were found to have a lower mean Sa02 of 92% compared to those discharged with Sa02 of 94% (p < 0.001). After the initial treatment at the A&E, those admitted still have a lower mean Sa02 of 94% compared to those discharged with a mean Sa02 of 96% (p < 0.001). However taking Sa02 of 92% as a predictor of admission hada sensitivity of 39% and a specificity of 80% but it had a high negative predictive value of 92%. Hence pulse oximetry alone is not sensitive for predicting admission in acute asthma in children.
    Matched MeSH terms: Oximetry
  3. Chin HJ, Seng QB
    Malays J Med Sci, 2004 Jul;11(2):34-40.
    PMID: 22973125 MyJurnal
    Children with bronchiolitis from Hospitals Universiti Sains Malaysia (HUSM) and Hospital Kota Bharu (HKB) were student using the Kristjansson Respiratory Score and the Wang Respiratory Score respectively. Saturation of oxygen (S(a)O(2)) was measured with a pulse-oximeter while the child is breathing room-air. Two observers assessed the respiratory scores in all children independently. The correlation between respiratory scores and S(a)O(2) was assessed using Spearman's Rho, and the inter-rater reliability of respiratory scores determined using intraclasscorelation coefficient. There were 29 children in HUSM and 25 from HKB with a median age of 8 months (IQR 4.5 months) and 9 months(IQR 7 months) respectively. In HUSM, the median Kristjansson Respiratory Score for both observers was 4 (IQR 2), and the median S(a)O(2) was 96% (IQR 3%). The correlation coefficient between the Kristjansson Respiratory Score and S(a)O(2) for the first observer was - 0.75 (p <0.001), and for the second observer -0.73 (p <0.001). In HKB, the median Wang Respiratory Score was also similar for both observers (median 4 IQR 4.5), and the median (IQR) for S(a)O(2) was 96% (2%). The correlation coefficient between the Wang Respiratory Score and S(a)O(2) for the first observer was -0.41 (p = 0.04) and for the second observer -0.43 (p = 0.03). The inter-rater reliability between the first and second observer was high for both the Kristjansson Respiratory (ICC 0.89) and the Wang Respiratory Scores (ICC 0.99). In conclusion the validity of the Kristjansson Respiratory Score was high whereas the validity of the Wang Respiratory Score was moderate in the assessment of the severity of acute bronchiolitis. Both respiratory scores and physical signs showed high agreement between observers. The Kristjansson Respiratory Score should be considered for use by medical personnel in the assessment of the severity of acute bronchiolitis in children.
    Matched MeSH terms: Oximetry
  4. Sahadan DZ, Davey MJ, Horne RS, Nixon GM
    Sleep Breath, 2015 Dec;19(4):1409-14.
    PMID: 25739713 DOI: 10.1007/s11325-014-1108-4
    PURPOSE: Overnight oximetry is a simple tool for investigation of obstructive sleep apnoea (OSA) in children, but only severe cases will be detected, and children with obstructive events resulting in arousal, but not desaturation, will have a normal (inconclusive) result. We hypothesised that pulse rate rises using pulse rate indices per hour (PRI) and pulse rate standard deviation (PR-SD) automatically calculated from commercially available software would improve oximetry as a diagnostic tool.

    METHODS: Children having home overnight oximetry for suspected OSA were identified over 12 months, and those with a normal result who went on to have polysomnography (PSG) were included. Oximetry, including PR-SD and PRI (rises of 8, 10 and 15 beats/min per hour), was analyzed using commercially available software. PR parameters were compared between those with OSA (obstructive apnoea-hypopnoea index (OAHI) >1 event/h) and those without OSA.

    RESULTS: One hundred sixteen children had normal oximetry, of whom 93 (median age 4.5 years; 55 % M) had PSG. Fifty-seven of 93 (61 %) children had OSA (median OAHI 4.5 events/h, range 1.1-24). PR-SD was not different between the OSA and non-OSA groups (p = 0.87). PRI tended to be higher in those with OSA, but there was considerable overlap between the groups: PRI-8 (mean ± SD 58.5 ± 29.0/h in OSA group vs 48.6 ± 20.2/h in non-OSA group, p = 0.07), PRI-10 (45.1 ± 25.0 vs 36.2 ± 16.7, p = 0.06) and PRI-15 (24.4 ± 14.5 vs 18.9 ± 9.0, p = 0.04). A PRI-15 threshold of >35/h had specificity of 97 % for OSA.

    CONCLUSION: The PRI-15 shows promise as an indicator of OSA in children with normal oximetry.

    Matched MeSH terms: Oximetry/methods*
  5. Jawin V, Ang HL, Omar A, Thong MK
    PLoS One, 2015;10(9):e0137580.
    PMID: 26360420 DOI: 10.1371/journal.pone.0137580
    Studies on pulse oximetry screening for neonatal sepsis and respiratory disease in a middle-income country are lacking. Newborn screening for critical congenital heart disease (CCHD) using pulse oximetry is an effective and life-saving strategy in developed countries. While most studies have reported false-positive results during CCHD screening, they have not elaborated on the detected disease types. We studied the effectiveness and outcomes of pulse oximetry newborn screening for non-cardiac hypoxemic diseases such as neonatal sepsis, respiratory diseases, and CCHD in a middle-income country.
    Matched MeSH terms: Oximetry*
  6. Hisham A, Hafizuddin Bin Salleh M, Ibrahim S, Mohd Yussof SJ
    Int Wound J, 2020 Aug;17(4):1097-1098.
    PMID: 32333718 DOI: 10.1111/iwj.13375
    Matched MeSH terms: Oximetry/adverse effects*
  7. Zahari M, Lee DS, Darlow BA
    J Clin Monit Comput, 2016 Oct;30(5):669-78.
    PMID: 26282827 DOI: 10.1007/s10877-015-9752-1
    The displayed readings of Masimo pulse oximeters used in the Benefits Of Oxygen Saturation Targeting (BOOST) II and related trials in very preterm babies were influenced by trial-imposed offsets and an artefact in the calibration software. A study was undertaken to implement new algorithms that eliminate the effects of offsets and artefact. In the BOOST-New Zealand trial, oxygen saturations were averaged and stored every 10 s up to 36 weeks' post-menstrual age. Two-hundred and fifty-seven of 340 babies enrolled in the trial had at least two weeks of stored data. Oxygen saturation distribution patterns corresponding with a +3 % or -3 % offset in the 85-95 % range were identified together with that due to the calibration artefact. Algorithms involving linear and quadratic interpolations were developed, implemented on each baby of the dataset and validated using the data of a UK preterm baby, as recorded from Masimo oximeters with the original software and a non-offset Siemens oximeter. Saturation distributions obtained were compared for both groups. There were a flat region at saturations 85-87 % and a peak at 96 % from the lower saturation target oximeters, and at 93-95 and 84 % respectively from the higher saturation target oximeters. The algorithms lowered the peaks and redistributed the accumulated frequencies to the flat regions and artefact at 87-90 %. The resulting distributions were very close to those obtained from the Siemens oximeter. The artefact and offsets of the Masimo oximeter's software had been addressed to determine the true saturation readings through the use of novel algorithms. The implementation would enable New Zealand data be included in the meta-analysis of BOOST II trials, and be used in neonatal oxygen studies.
    Matched MeSH terms: Oximetry/methods*
  8. Rashid NH, Zaghi S, Scapuccin M, Camacho M, Certal V, Capasso R
    Laryngoscope, 2021 02;131(2):440-447.
    PMID: 32333683 DOI: 10.1002/lary.28663
    OBJECTIVES: Intermittent hypoxemia is a risk factor for developing complications in obstructive sleep apnea (OSA) patients. The objective of this systematic review was to identify articles evaluating the accuracy of the oxygen desaturation index (ODI) as compared with the apnea-hypopnea index (AHI) and then provide possible values to use as a cutoff for diagnosing adult OSA.

    STUDY DESIGN: Systematic Review of Literature.

    METHODS: PubMed, the Cochrane Library, and SCOPUS databases were searched through November 2019.

    RESULTS: Eight studies (1,924 patients) met criteria (age range: 28-70.9 years, body mass index range: 21.9-37 kg/m2 , and AHI range: 0.5-62 events/hour). Five studies compared ODI and AHI simultaneously, and three had a week to months between assessments. Sensitivities ranged from 32% to 98.5%, whereas specificities ranged from 47.7% to 98%. Significant heterogeneity was present; however, for studies reporting data for a 4% ODI ≥ 15 events/hour, the specificity for diagnosing OSA ranged from 75% to 98%, and only one study reported the positive predictive value, which was 97%. Direct ODI and AHI comparisons were not made because of different hypopnea scoring, different oxygen desaturation categories, and different criteria for grading OSA severity.

    CONCLUSION: Significant heterogeneity exists in studies comparing ODI and AHI. Based on currently published studies, consideration should be given for diagnosing adult OSA with a 4% ODI of ≥ 15 events/hour and for recommending further evaluation for diagnosing OSA with a 4% ODI ≥ 10 events/hour. Screening with oximetry may be indicated for the detection of OSA in select patients. Further study is needed before a definitive recommendation can be made. Laryngoscope, 131:440-447, 2021.

    Matched MeSH terms: Oximetry
  9. Mondal H, Mondal S
    Malays Fam Physician, 2021 Mar 25;16(1):8-14.
    PMID: 33948137 DOI: 10.51866/rv1097
    Home health monitoring devices are consumer-grade devices that help to monitor the health of individuals at home. These devices are usually low-cost and easily procurable, and they can be operated by patients or their caretakers with minimal training. However, improper usage of these devices may provide erroneous results, which can lead to an unnecessary hospital visit or teleconsultation. In this article, we discuss the basic technology and proper usage of some of these devices, namely automatic blood pressure monitors, blood glucose monitors, body fat monitors, pulse oximeters, electrocardiographs, digital thermometers, and infrared thermometers. This brief document intends to help primary health care professionals and their patients use these devices.
    Matched MeSH terms: Oximetry
  10. Chiong XH, Wong ZZ, Lim SM, Ng TY, Ng KT
    Ann Card Anaesth, 2022;25(4):384-398.
    PMID: 36254901 DOI: 10.4103/aca.aca_149_21
    High prevalence of cerebral desaturation is associated with postoperative neurological complications in cardiac surgery. However, the evidence use of cerebral oximetry by correcting cerebral desaturation in the reduction of postoperative complications remains uncertain in the literature. This systematic review and meta-analysis aimed to examine the effect of cerebral oximetry on the incidence of postoperative cognitive dysfunction in cardiac surgery. Databases of MEDLINE, EMBASE, and CENTRAL were searched from their inception until April 2021. All randomized controlled trials comparing cerebral oximetry and blinded/no cerebral oximetry in adult patients undergoing cardiac surgery were included. Observational studies, case series, and case reports were excluded. A total of 14 trials (n = 2,033) were included in this review. Our pooled data demonstrated that patients with cerebral oximetry were associated with a lower incidence of postoperative cognitive dysfunction than the control group (studies = 4, n = 609, odds ratio [OR]: 0.15, 95% confidence interval [CI]: 0.04 to 0.54, P = 0.003, I2 = 88%; certainty of evidence = very low). In terms of postoperative delirium (OR: 0.75, 95%CI: 0.50-1.14, P = 0.18, I2 = 0%; certainty of evidence = low) and postoperative stroke (OR: 0.81 95%CI: 0.37-1.80, P = 0.61, I2 = 0%; certainty of evidence = high), no significant differences (P > 0.05) were reported between the cerebral oximetry and control groups. In this meta-analysis, the use of cerebral oximetry monitoring in cardiac surgery demonstrated a lower incidence of postoperative cognitive dysfunction. However, this finding must be interpreted with caution due to the low level of evidence, high degree of heterogeneity, lack of standardized cognitive assessments, and cerebral desaturation interventions.
    Matched MeSH terms: Oximetry
  11. Oei JL, Saugstad OD, Lui K, Wright IM, Smyth JP, Craven P, et al.
    Pediatrics, 2017 01;139(1).
    PMID: 28034908 DOI: 10.1542/peds.2016-1452
    BACKGROUND AND OBJECTIVES: Lower concentrations of oxygen (O2) (≤30%) are recommended for preterm resuscitation to avoid oxidative injury and cerebral ischemia. Effects on long-term outcomes are uncertain. We aimed to determine the effects of using room air (RA) or 100% O2 on the combined risk of death and disability at 2 years in infants <32 weeks' gestation.

    METHODS: A randomized, unmasked study designed to determine major disability and death at 2 years in infants <32 weeks' gestation after delivery room resuscitation was initiated with either RA or 100% O2 and which were adjusted to target pulse oximetry of 65% to 95% at 5 minutes and 85% to 95% until NICU admission.

    RESULTS: Of 6291 eligible patients, 292 were recruited and 287 (mean gestation: 28.9 weeks) were included in the analysis (RA: n = 144; 100% O2: n = 143). Recruitment ceased in June 2014, per the recommendations of the Data and Safety Monitoring Committee owing to loss of equipoise for the use of 100% O2. In non-prespecified analyses, infants <28 weeks who received RA resuscitation had higher hospital mortality (RA: 10 of 46 [22%]; than those given 100% O2: 3 of 54 [6%]; risk ratio: 3.9 [95% confidence interval: 1.1-13.4]; P = .01). Respiratory failure was the most common cause of death (n = 13).

    CONCLUSIONS: Using RA to initiate resuscitation was associated with an increased risk of death in infants <28 weeks' gestation. This study was not a prespecified analysis, and it was underpowered to address this post hoc hypothesis reliably. Additional data are needed.

    Matched MeSH terms: Oximetry/methods
  12. Poh AH, Adikan FRM, Moghavvemi M
    Med Biol Eng Comput, 2020 Jun;58(6):1159-1175.
    PMID: 32319030 DOI: 10.1007/s11517-019-02077-9
    The study and applications of in vivo skin optics have been openly documented as early as the year 1954, or possibly earlier. To date, challenges in analyzing the complexities of this field remain, with wide scopes requiring more scrutiny. Recent advances in spectroscopic research and multivariate analytics allow a closer look into applications potentially for detecting or monitoring diseases. One of the challenges in this field is in establishing a reference for applications which correspond to certain bandwidths. This article reviews the scope on past research on skin spectroscopy, and the clinical aspects which have or may have applications on disease detection or enhancing diagnostics. A summary is supplied on the technicalities surrounding the measurements reported in literature, focused towards the wavelength-dependent applications in themes central to the respective research. Analytics on the topology of the papers' data cited in this work is also provided for a statistical perspective. In short, this paper strives to immediately inform the reader with possible applications via the spectroscopic devices at hand. Graphical Abstract .
    Matched MeSH terms: Oximetry/methods
  13. Wang CY, Ling LC, Cardosa MS, Wong AK, Wong NW
    Anaesthesia, 2000 Jul;55(7):654-8.
    PMID: 10919420
    In Study A, the incidence of arterial oxygen desaturation was studied using pulse oximetry (SaO2) in 100 sedated and 100 nonsedated patients breathing room air who underwent diagnostic upper gastrointestinal endoscopy. Hypoxia (SaO2 92% or less of at least 15 s duration) occurred in 17% and 6% of sedated patients and nonsedated patients, respectively (p < 0.03). Mild desaturation (SaO2 94% or less and less than 15 s duration) occurred in 47% of sedated patients compared with 12% of nonsedated patients (p < 0.001). In Study B, the effects of supplementary oxygen therapy and the effects of different pre-oxygenation times on arterial oxygen saturation (SaO2) in sedated patients were studied using pulse oximetry. One hundred and twenty patients who underwent diagnostic upper gastrointestinal endoscopy with intravenous sedation were studied. Patients were randomly allocated to one of four groups: Group A (n = 30) received no supplementary oxygen while Groups B-D received supplementary oxygen at 4 1 x min(-1) via nasal cannulae. The pre-oxygenation time in Group B (n = 30) was zero minutes, Group C (n = 30) was 2 min and Group D (n = 30) was 5 min before sedation and introduction of the endoscope. Hypoxia occurred in seven of the 30 patients in Group A and none in groups B, C and D (p < 0.001). We conclude that desaturation and hypoxia is common in patients undergoing upper gastrointestinal endoscopy with and without sedation. Sedation significantly increases the incidence of desaturation and hypoxia. Supplementary nasal oxygen at 4 1 x min(-1) in sedated patients abolishes desaturation and hypoxia. Pre-oxygenation confers no additional benefit.
    Matched MeSH terms: Oximetry
  14. Jeyamalar R, Sivanesaratnam V, Kuppuvelumani P
    Aust N Z J Obstet Gynaecol, 1992 Aug;32(3):275-7.
    PMID: 1445144
    Matched MeSH terms: Oximetry
  15. Abbasi H, Saqib M, Jouhar R, Lal A, Ahmed N, Ahmed MA, et al.
    Biomed Res Int, 2021;2021:1119710.
    PMID: 34124238 DOI: 10.1155/2021/1119710
    Introduction: Dental anxiety is a common occurrence in patients undergoing dental treatments, especially in children. The success in paedriatric dental treatments and patient comfort depends on controlling the level of patient's anxiety in clinical settings. This study is aimed at evaluating the efficacy of different techniques applied for the reduction of dental anxiety in paediatric patients. Material and Methods. One hundred and sixty participants were divided into 4 groups; each group having 40 patients as follows: group I: mobile application "little lovely dentist," group II: YouTube® "dental video songs," group III "tell-show-do," and group IV "control." Dental prophylaxis treatments were provided to all the participants. Initial anxiety levels were noted during the patient's education phase by measuring heart rate with pulse oximeter and distress level with facial image scale, at the same time in each group, respectively. The postoperative anxiety was noted later with the same methods, after the application of anxiety reduction techniques. The data obtained were entered in the statistical package for the social sciences software, version 25. One-way ANOVA and paired t-test for matched groups were used to compare mean values of the 4 groups, in this study to determine their effectiveness. A p value of ≤0.05 was considered as statistically significant.

    Results: The mean age of patients in group 1 was 6.8 ± 2.1 years, group 2: 8.15 ± 2.27 years, group 3: 7.5 ± 2.3 years, and group 4: 7.27 ± 1.68 years. The intragroup comparisons of heart rate and facial image scores have shown a significant difference in before and after dental treatment procedures. Marked reduction in heart rate and facial image scale scores were found in patients belonging to group 1 (mobile applications) and group 2 (dental video songs). An increase in heart rate and facial image scale scores was seen in group 3 (tell-show-do) and the control group.

    Conclusion: The paediatric dental anxiety is a common finding in dental clinics. Behavior modification techniques like smartphone applications, "little lovely dentist," and "dental songs" can alleviate dental anxiety experienced by paediatric patients. The "tell-show-do" technique although most commonly used did not prove to be beneficial in the reduction of the anxiety levels.

    Matched MeSH terms: Oximetry
  16. Jamal R, Baizura J, Hamidah A, Idris N, Jeffrey AH, Roslan H
    PMID: 15906681
    The aim of this study was to: (1) determine the prevalence and patterns of lung dysfunction among transfusion dependent thalassemics; (2) determine the associated factors that might contribute to this problem. This was a cross-sectional study involving 66 patients with transfusion dependent thalassemia aged 10 years and above. All patients underwent physical examination, standardized pulmonary function tests including spirometry, lung volume, and the carbon monoxide diffusion capacity. A restrictive pattern of lung dysfunction was observed in 22 patients (33.3%) and none showed the presence of obstructive ventilatory impairment. A reduction in the carbon monoxide diffusion capacity (DLCO) was seen 87.9% of the patients, including 7.6% who had evidence of hypoxemia. Ten patients showed a reduction in the FEF25-75% although they did not fulfil the criteria for small airway disease. No correlation was found between lung dysfunction and serum ferritin levels in the patients. Restrictive lung dysfunction and diffusion impairment were the predominant abnormalities found in our cohort of patients.
    Study site: Thalassemia clinic, Pusat Perubatan Universiti Kebangsaan Malaysia (PPUKM), Kuala Lumpur, Malaysia
    Matched MeSH terms: Oximetry
  17. Doufas AG, Shafer SL, Rashid NHA, Kushida CA, Capasso R
    Anesthesiology, 2019 02;130(2):213-226.
    PMID: 30247202 DOI: 10.1097/ALN.0000000000002430
    BACKGROUND: Evidence suggests that obstructive sleep apnea promotes postoperative pulmonary complications by enhancing vulnerability to opioid-induced ventilatory depression. We hypothesized that patients with moderate-to-severe obstructive sleep apnea are more sensitive to remifentanil-induced ventilatory depression than controls.

    METHODS: After institutional approval and written informed consent, patients received a brief remifentanil infusion during continuous monitoring of ventilation. We compared minute ventilation in 30 patients with moderate-to-severe obstructive sleep apnea diagnosed by polysomnography and 20 controls with no to mild obstructive sleep apnea per polysomnography. Effect site concentrations were estimated by a published pharmacologic model. We modeled minute ventilation as a function of effect site concentration and the estimated carbon dioxide. Obstructive sleep apnea status, body mass index, sex, age, use of continuous positive airway pressure, apnea/hypopnea events per hour of sleep, and minimum nocturnal oxygen saturation measured by pulse oximetry in polysomnography were tested as covariates for remifentanil effect site concentration at half-maximal depression of minute ventilation (Ce50) and included in the model if a threshold of 6.63 (P < 0.01) in the reduction of objective function was reached and improved model fit.

    RESULTS: Our model described the observed minute ventilation with reasonable accuracy (22% median absolute error). We estimated a remifentanil Ce50 of 2.20 ng · ml (95% CI, 2.09 to 2.33). The estimated value for Ce50 was 2.1 ng · ml (95% CI, 1.9 to 2.3) in patients without obstructive sleep apnea and 2.3 ng · ml (95% CI, 2.2 to 2.5) in patients with obstructive sleep apnea, a statistically nonsignificant difference (P = 0.081). None of the tested covariates demonstrated a significant effect on Ce50. Likelihood profiling with the model including obstructive sleep apnea suggested that the effect of obstructive sleep apnea on remifentanil Ce50 was less than 5%.

    CONCLUSIONS: Obstructive sleep apnea status, apnea/hypopnea events per hour of sleep, or minimum nocturnal oxygen saturation measured by pulse oximetry did not influence the sensitivity to remifentanil-induced ventilatory depression in awake patients receiving a remifentanil infusion of 0.2 μg · kg of ideal body weight per minute.

    Matched MeSH terms: Oximetry
  18. Isa R, Wan Adnan WA, Ghazali G, Idris Z, Ghani AR, Sayuthi S, et al.
    Neurosurg Focus, 2003 Dec 15;15(6):E1.
    PMID: 15305837
    The determination of cerebral perfusion pressure (CPP) is regarded as vital in monitoring patients with severe traumatic brain injury. Besides indicating the status of cerebral blood flow (CBF), it also reveals the status of intracranial pressure (ICP). The abnormal or suboptimal level of CPP is commonly correlated with high values of ICP and therefore with poor patient outcomes. Eighty-two patients were divided into three groups of patients receiving treatment based on CPP and CBF, ICP alone, and conservative methods during two different observation periods. The characteristics of these three groups were compared based on age, sex, time between injury and hospital arrival, Glasgow Coma Scale score, pupillary reaction to light, surgical intervention, and computerized tomography scanning findings according to the Marshall classification system. Only time between injury and arrival (p = 0.001) was statistically significant. There was a statistically significant difference in the proportions of good outcomes between the multimodality group compared with the group of patients that underwent a single intracranial-based monitoring method and the group that received no monitoring (p = 0.003) based on a disability rating scale after a follow up of 12 months. Death was the focus of outcome in this study in which the multimodality approach to monitoring had superior results.
    Matched MeSH terms: Oximetry
Related Terms
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links