Affiliations 

  • 1 Department of Civil Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, 43600 UKM, Bangi, Selangor, Malaysia
  • 2 Institute of Tropical Biodiversity and Sustainable Development, Universiti Malaysia Terengganu, 21030, Kuala Nerus, Terengganu, Malaysia
  • 3 Department of Chemical and Process Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, 43600 UKM, Bangi, Selangor, Malaysia
  • 4 Department of Chemical and Biological Engineering, The University of Sheffield, Western Bank, Sheffield, S10 2TN, UK
  • 5 Functional Omics and Bioprocess Development Laboratory, Institute of Biological Sciences, Faculty of Science, Universiti Malaya, 50603, Kuala Lumpur, Wilayah Persekutuan Kuala Lumpur, Malaysia
  • 6 Department of Civil Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, 43600 UKM, Bangi, Selangor, Malaysia. [email protected]
PMID: 33624249 DOI: 10.1007/s11356-021-12686-3

Abstract

The fungi-based technology, wild-Serbian Ganoderma lucidum (WSGL) as myco-alternative to existing conventional microbial-based wastewater treatment is introduced in this study as a potential alternative treatment. The mycoremediation is highly persistent for its capability to oxidatively breakdown pollutant substrates and widely researched for its medicinal properties. Utilizing the nonhazardous properties and high degradation performance of WSGL, this research aims to optimize mycoremediation treatment design for chemical oxygen demand (COD) and ammonia nitrogen (AN) removal in domestic wastewater based on proposed Model 1 (temperature and treatment time) and Model 2 (volume of pellet and treatment time) via response surface methodology (RSM). Combined process variables were temperature (0C) (Model 1) and the volume of mycelial pellets (%) (Model 2) against treatment time (hour). Response variables for these two sets of central composite design (CCD) were the removal efficiencies of COD (%) and AN (%). The regression line fitted well with the data with R2 values of 0.9840 (Model 1-COD), 0.9477 (Model 1-AN), 0.9988 (Model 2-COD), and 0.9990 (Model 2-AN). The lack of fit test gives the highest value of sum of squares equal to 9494.91 (Model 1-COD), 9701.68 (Model 1-AN), 23786.55 (Model 2-COD), and 13357.02 (Model 2-AN), with probability F values less than 0.05 showing significant models. The optimized temperature for Model 1 was at 25 °C within 24 h of treatment time with 95.1% COD and 96.3% AN removals. The optimized condition (temperature) in Model 1 was further studied in Model 2. The optimized volume of pellet for Model 2 was 0.25% in 24-h treatment time with 76.0% COD and 78.4% AN removals. Overall, the ascended sequence of high volume of pellet considered in Model 2 will slow down the degradation process. The best fit volume of pellet with maximum degradation of COD and AN is equivalent to 0.1% at 25 °C in 24 h. The high performance achieved demonstrates that the mycoremediation of G. lucidum is highly potential as part of the wastewater treatment system in treating domestic wastewater of high organic loadings.

* Title and MeSH Headings from MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine.