Affiliations 

  • 1 Department of Civil and Structural Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor, Malaysia
  • 2 Department of Civil and Structural Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor, Malaysia. Electronic address: [email protected]
  • 3 Envirosource Sdn Bhd, No. 13A, Jalan Jernang Jaya 1, Taman Jernang Jaya, 43650 Bandar Baru Bangi, Selangor, Malaysia
Bioresour Technol, 2018 Jul;260:213-220.
PMID: 29626780 DOI: 10.1016/j.biortech.2018.03.131

Abstract

The anaerobic treatment of leachate from a municipal waste transfer station in Malaysia was tested using a pilot scale anaerobic biofilm digester system that was operated under HRT sequence of 30-day, 25-day, 20-day and 10-day for 163 days under mesophilic conditions. Despite the leachate's complex characteristics, the system showed great performance given its maximum COD, BOD5 and total phosphorus removal efficiencies of 98 ± 1%, 99 ± 1% and 92 ± 9% respectively. The system was stable throughout its operation and showed optimal average values for the monitored parameters such as pH (7.53 ± 0.14), total VFA (79 ± 66 mg HOAc/L), alkalinity (10,919 ± 1556 mg CaCO3/L) and a non-toxic value for accumulated ammonia (960 ± 106 mg NH3-N/L). Measurement of the average daily biogas production yielded a value of 25 ± 1 m3/day throughout the system's operation with a composition of 57 ± 12% methane and 26 ± 6% carbon dioxide.

* Title and MeSH Headings from MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine.