Affiliations 

  • 1 University of Malaya
Neurology Asia, 2015;20(2):161-165.
MyJurnal

Abstract

Objective: To delineate and differentiate between late subacute hemorrhage and intracranial lipomas in clinically available conventional and advanced MR sequences. Methods: Two cases of late subacute hemorrhage and two cases of intracranial lipoma were reviewed with CT scans and 3.0T scanner MRI. The sequences evaluated in MRI were T1-weighted (T1W) fast spin echo (FSE), T2-weighted (T2W) FSE, gradient echo T2*-weighted (GRE T2*W) images, diffusion weighted (DWI), apparent diffusion coefficient (ADC) and multivoxel spectroscopy. Results: Late subacute hemorrhage and intracranial lipoma have similar imaging features on T1W, T2W FSE with blooming artefact at the margins on GRE T2*W. However on GRE T2*W sequence, the central area of lipoma demonstrates low signal; while hemorrhage demonstrates high signal. In DWI, late subacute hemorrhage shows hyperintensity; while in lipoma there is loss of signal.
Conclusion: Awareness of the potential pitfalls in standard sequence are important, as these entities appear to have similar T1W/ T2W characteristic with blooming artefact on T2*W. Knowing the distinctive central signal intensity pattern on GRE T2W* and DWI is therefore essential to differentiate between these lesions as there are differences to their clinical management.