Displaying all 3 publications

Abstract:
Sort:
  1. Sivalingam N, Teng YH, Chong XY, Low CH, Manocha SK, Intan Sabreena MS
    Med J Malaysia, 2018 06;73(3):147-153.
    PMID: 29962498 MyJurnal
    INTRODUCTION: The aim of this systematic review is to compare the vaginal erosion rates in different synthetic materials used in suburethral slings in Tension Free Vaginal Tape (TVT-O /TOT) procedures in management of female stress urinary incontinence.

    METHODS: PRISMA 2009 framework was adopted for study design. Scholarly literature search was done using MEDLINE, EMBASE, the Cochrane Library and Clinical Trials.gov using selected keywords. Five articles fulfilled the inclusion and exclusion criteria. Our main outcome of interest is to review the ideal properties of the suburethral sling, procedure of insertion and post-surgical complication following the sling insertion primarily vaginal erosion. Results were compared using one way-ANOVA test and independent T- test.

    RESULTS: Total of 1725 subjects were available for analysis in the five studies. Monofilament polypropylene constituted 92.5% of the total sample size from one study alone. Polyester (n= 16/51) causes higher incidence rate of vaginal erosion compared to monofilament polypropylene (31.4 vs., 4.7; p = 0.01). There was no difference in the vaginal erosion rate between monofilament polypropylene and multifilament polypropylene (4.7 vs, 14.1; p=0.055) as well as between multifilament polypropylene and polyester (14.1 vs, 31.4; p=0.068). Although there was a marginally lower rate of vaginal erosion in TVT-O over TVT, the difference was not significant. (5.6 vs., 6.4, p=0.468). Common presentations of vaginal erosion were vaginal discharge, perineal pain and dyspareunia.

    CONCLUSION: Given the limited sample size, polyester sling material appears to cause higher rates of vaginal erosion. No difference in erosion rate was seen between TVT and TVT-O.

    Matched MeSH terms: Suburethral Slings/adverse effects*
  2. Rajendra M, Han HC, Lee LC, Tseng LA, Wong HF
    Int Urogynecol J, 2012 Mar;23(3):327-34.
    PMID: 21892684 DOI: 10.1007/s00192-011-1552-7
    INTRODUCTION AND HYPOTHESIS: We aim to report the 3-year outcome and complications of the tension-free vaginal tape obturator (TVT-O) in treating female stress urinary incontinence (SUI).

    METHODS: Retrospective analysis for complications and outcome of surgery was performed in 419 women undergoing the TVT-O from 2004 to 2006.

    RESULTS: Three patients (0.8%) with an isolated TVT-O had a blood loss of more than 200 ml. Two patients (0.5%) had bladder perforation. Out of 11 readmitted patients (2.6%), 10 were due to voiding difficulty. Six patients (1.4%) required tape loosening or division. Persistent pain occurred in 3.6% and erosion in 2.4% of patients. One hundred eighty-five patients (44.2%) came for follow-up at 3 years. The actual subjective and objective success rates were 89.7% and 99.9% at 3 years follow-up, respectively. With imputation, the 3-year subjective and objective success rates were 86.9% and 97.4%, respectively.

    CONCLUSIONS: The TVT-O is effective in treating female SUI with minimal complications.

    Matched MeSH terms: Suburethral Slings/adverse effects*
  3. Lo TS, Tan YL, Wu PY, Cortes EF, Pue LB, Al-Kharabsheh A
    PMID: 25265496 DOI: 10.1016/j.ejogrb.2014.09.015
    To evaluate the ultrasound morphology and its clinical outcome among women who had undergone Miniarc™ vs Monarc™ in the treatment of stress urinary incontinence (SUI).
    Matched MeSH terms: Suburethral Slings/adverse effects*
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links