Displaying all 3 publications

Abstract:
Sort:
  1. Foo CY, Bonsu KO, Nallamothu BK, Reid CM, Dhippayom T, Reidpath DD, et al.
    Heart, 2018 08;104(16):1362-1369.
    PMID: 29437704 DOI: 10.1136/heartjnl-2017-312517
    OBJECTIVE: This study aims to determine the relationship between door-to-balloon delay in primary percutaneous coronary intervention and ST-elevation myocardial infarction (MI) outcomes and examine for potential effect modifiers.

    METHODS: We conducted a systematic review and meta-analysis of prospective observational studies that have investigated the relationship of door-to-balloon delay and clinical outcomes. The main outcomes include mortality and heart failure.

    RESULTS: 32 studies involving 299 320 patients contained adequate data for quantitative reporting. Patients with ST-elevation MI who experienced longer (>90 min) door-to-balloon delay had a higher risk of short-term mortality (pooled OR 1.52, 95% CI 1.40 to 1.65) and medium-term to long-term mortality (pooled OR 1.53, 95% CI 1.13 to 2.06). A non-linear time-risk relation was observed (P=0.004 for non-linearity). The association between longer door-to-balloon delay and short-term mortality differed between those presented early and late after symptom onset (Cochran's Q 3.88, P value 0.049) with a stronger relationship among those with shorter prehospital delays.

    CONCLUSION: Longer door-to-balloon delay in primary percutaneous coronary intervention for ST-elevation MI is related to higher risk of adverse outcomes. Prehospital delays modified this effect. The non-linearity of the time-risk relation might explain the lack of population effect despite an improved door-to-balloon time in the USA.

    CLINICAL TRIAL REGISTRATION: PROSPERO (CRD42015026069).

    Matched MeSH terms: ST Elevation Myocardial Infarction/surgery*
  2. Ismail MD, Jalalonmuhali M, Azhari Z, Mariapun J, Lee ZV, Zainal Abidin I, et al.
    BMC Cardiovasc Disord, 2018 09 24;18(1):184.
    PMID: 30249197 DOI: 10.1186/s12872-018-0919-9
    BACKGROUND: Patients with renal impairment often left out from most major clinical trials assessing the optimal treatment for ST-elevation myocardial infarction (STEMI). Large body of evidence from various cardiovascular registries reflecting more 'real-world' experience might contribute to the knowledge on how best to treat this special cohort. We aim to analyze the outcomes of Malaysian STEMI patients with renal impairment treated with coronary angioplasty.

    METHODS: Utilizing the Malaysian National Cardiovascular Disease Database-Percutaneous Coronary Intervention (NCVD-PCI) registry data from 2007 to 2014, STEMI patients treated with percutaneous coronary intervention (PCI) were stratified into presence (GFR 

    Matched MeSH terms: ST Elevation Myocardial Infarction/surgery*
  3. Montefusco A, De Filippo O, Gili S, Mancone M, Calcagno S, Cirillo P, et al.
    Coron Artery Dis, 2020 01;31(1):27-34.
    PMID: 31658146 DOI: 10.1097/MCA.0000000000000790
    AIMS: To assess the long-term outcomes of patients treated with sirolimus-eluting Stentys stent in a real-life setting.

    BACKGROUND: Few data regarding the safety and effectiveness of self-apposing sirolimus-eluting Stentys stent are available.

    METHODS: 278 patients (30% stable coronary artery disease, 70% acute coronary syndromes, and 54% on unprotected left main) treated with sirolimus eluting Stentys stent were retrospectively included in the self-aPposing, bAlloon-delivered, siRolimus-eluting stent for the Treatment of the coronary Artery disease multicenter registry. Major adverse cardiovascular events (MACE, a composite of cardiac death, myocardial infarction, target lesion revascularization, stent thrombosis) were the primary end-point, single components of MACE were the secondary ones.

    RESULTS: After 13 months (interquartile range 5-32), MACE was 14%. Stent thrombosis occurred in 3.9% of the patients (2.5% definite stent thrombosis and 1.4% probable stent thrombosis), 66% of them presenting with ST-segment elevation myocardial infarction (STEMI) at admission. Cardiovascular death, target lesion revascularization and myocardial infarction was 4.7%, 8.3%, and 7.2%, respectively. At multivariate analysis, risk of MACE was increased by diabetes (hazard ratios 4.76; P = 0.002) but was not affected by the indication leading to sirolimus-eluting Stentys stent implantation (marked vessel tapering vs. coronary ecstasies, hazard ratios 0.74, P = 0.71).

    CONCLUSION: Sirolimus-eluting Stentys stent may represent a potential solution for specific coronary anatomies such as bifurcation, ectasic, or tapered vessels. Risk of stent thrombosis appears related to clinical presentation with STEMI and to anatomic features, stressing the importance of the use of intracoronary imaging for self-expandable stents implantation.

    Matched MeSH terms: ST Elevation Myocardial Infarction/surgery*
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links