Displaying all 9 publications

Abstract:
Sort:
  1. Tan KL
    Acta Paediatr Scand, 1982 Jul;71(4):593-6.
    PMID: 7136674
    Matched MeSH terms: Jaundice, Neonatal/blood*
  2. Lie-Injo LE, Randhawa ZI, Ganesan J, Kane J, Peterson D
    Hemoglobin, 1977;1(8):747-57.
    PMID: 604313
    The trait condition for hemoglobin Tak, was found in a 4-day old newborn Malay who suffered from severe neonatal jaundice. The beta chain of the abnormal hemoglobin was elongated by 11 residues at the C-terminus and had the same structure as reported for Hb Tak. The mother was heterozygous for this abnormal hemoglobin, the father was normal. The mother and child, 4 years later, did not show clinical or hematological symptoms except definitely increased resistance of their erythrocytes to hypotonic saline solutions and slight anisopoikilocytosis. The abnormal gene in the two reported Thai families and in our Malay family may have the same origin.
    Matched MeSH terms: Jaundice, Neonatal/blood
  3. Boo NY, Lee HT
    J Paediatr Child Health, 2002 Apr;38(2):151-5.
    PMID: 12030996
    OBJECTIVE: To compare the rates of decrease in serum bilirubin levels in severely jaundiced healthy term infants given oral or intravenous fluid supplementation during phototherapy.

    METHODS: A randomized controlled study was carried out in the neonatal intensive care unit (NICU) of Hospital Universiti Kebangsaan Malaysia over a 12-month period. Fifty-four healthy term infants with severe hyperbilirubinemia were randomized to receive either solely enteral feeds (n = 27) or both enteral and intravenous (n = 27) fluid during phototherapy.

    RESULTS: There were no significant differences in the mean birthweight, mean gestational age, ethnic distribution, gender distribution, modes of delivery and types of feeding between the two groups. Similarly, there was no significant difference in the mean indirect serum bilirubin (iSB) level at the time of admission to the NICU between the enteral (359 +/- 69 micromol/L [mean +/- SD]) and intravenous group (372 +/- 59 micromol/L; P = 0.4). The mean rates of decrease in iSB during the first 4 h of phototherapy were also not significantly different between the enteral group (10.4 +/- 4.9 micromol/L per h) and intravenous group (11.2 +/- 7.4 micromol/L per h; P = 0.6). There was no significant difference in the proportion of infants requiring exchange transfusion (P = 0.3) nor in the median duration of hospitalization (P = 0.7) between the two groups. No infant developed vomiting or abdominal distension during the study period.

    CONCLUSION: Severely jaundiced healthy term infants had similar rates of decrease in iSB levels during the first 4 h of intensive phototherapy, irrespective of whether they received oral or intravenous fluid supplementation. However, using the oral route avoided the need for intravenous cannulae and their attendant complications.

    Matched MeSH terms: Jaundice, Neonatal/blood
  4. Boo NY, Abu Bakar A
    Med J Malaysia, 1984 Mar;39(1):35-7.
    PMID: 6513837
    The transcutaneous (Tc) bilirubinometer was evaluated in 105 jaundiced neonates, comprising 38 Malays, 37 Chinese and 30 Indians, who had not been treated with phototherapy or exchange transfusion. Tc bilirubin index and serum bilirubin concentration correlated at statistically significant levels in all the three racial groups. Unlike the Chinese and Malay babies, the action levels, using Tc bilirubin index, in the Indian babies are not reliable due to the wide variation of skin pigmentation. Neonatal jaundice is conventionally monitored by estimation of serum bilirubin level. This involves blood sampling. The transcutaneous (Tc) bilirubinometer, however, is non-invasive, small and portable. In this study, the use of the Tc bilirubinometer in the management of neonatal jaundice' in the three racial groups was evaluated.
    Matched MeSH terms: Jaundice, Neonatal/blood*
  5. Tan KL
    J Singapore Paediatr Soc, 1977 Dec;19(4):238-40.
    PMID: 616476
    Matched MeSH terms: Jaundice, Neonatal/blood*
  6. Chua BS, Song LH, Chang CT, Lim XJ, Nachiappan J
    J Paediatr Child Health, 2021 01;57(1):12-14.
    PMID: 33078471 DOI: 10.1111/jpc.15226
    The coronavirus disease 2019 (COVID-19) cases was on an increasing trend, including in Malaysia. The Malaysian Ministry of Health had implemented a range of measures, such as the use of masks and social distancing, to reduce the risk of transmission. Traditionally, newborns are evaluated for neonatal jaundice using visual assessment, a capillary heel prick and serum bilirubin (SB) sampling in primary health-care clinics. This approach requires the physical presence of both parents and their newborns in the primary health-care clinics, causing crowding and increasing the risk of COVID-19 infections. To alleviate crowding, we implemented the transcutaneous bilirubin drive-through (DT) service, which is an established, non-invasive, painless and rapid method to determine the bilirubin levels. Throughout the screening, both parents and baby will be confined to their car. A total of 1842 babies were screened in our DT setting from April to July 2020. Of the total babies, 298 (16.1%) required venesection for SB measurement and 85 required admission for phototherapy. None with severe jaundice were missed since the implementation of this service. The average test duration per neonate was less than 5 min, while conventional venous bilirubin laboratory testing required an average of 1.5 h per neonate. The cost of the SB laboratory test and consumables was approximately USD 5 per test, with an estimated cost savings of USD 7720. DT screening may be introduced in health-care settings to reduce crowding and eliminate the need of painful blood sampling in newborns.
    Matched MeSH terms: Jaundice, Neonatal/blood
  7. Lie-Injo LE, Virik HK, Lim PW, Lie AK, Ganesan J
    Acta Haematol., 1977;58(3):152-60.
    PMID: 409030 DOI: 10.1159/000207822
    A study was carried out of 332 babies suffering from severe neonatal jaundice who were admitted to the General Hospital, Kuala Lumpar, Malaysia. Of the 332 neonates, 51 were premature and 281 were full-term babies, 178 (110 Chinese, 58 Malay, 9 Indian and 1 European-Pakistani) had bilirubin levels of 20 mg% or higher, requiring exchange blood transfusion. Of the Chinese neonates, 23 (20.9%) had G6PD deficiency, 9 (8.2%) had Hb Bart's and 2 (1.8%) had an abnormal haemoglobin, one Hb Q and one fetal variant. Among the Malay infants, 10 (17.2%) had G6PD deficiency, 7 (12.1%) had Hb Bart's and 10 (17.2%) had abnormal haemoglobins (four had Hb E trait, one had Hb K and Bart's in addition to Hb E, three had Hb CoSp with Hb Bart's, one had Hb Q and one Hb Tak). One of the nine Indian neonates had G6PD deficiency and one had Hb S trait. The one European-Pakistani baby was a carrier of Hb D Punjab. In addition to G6PD deficiency, abnormal haemoglobins seem to have contributed to the high incidence of severe neonatal jaundice in Malaysia. The mean activities of GP, GR and GR after stimulation with FAD were higher, while the mean activity of PK and mean level of reduced glutathione were lower than in normal cord bloods. The percent increase of GR after FAD stimulation was significantly lower; fewer in this group had increases above 20% than in normal cord blood. The possible significance of the findings is discussed.
    Matched MeSH terms: Jaundice, Neonatal/blood*
  8. Boo NY, Chang YF, Leong YX, Tok ZY, Hooi LC, Chee SC, et al.
    Pediatr Res, 2019 08;86(2):216-220.
    PMID: 30696987 DOI: 10.1038/s41390-019-0304-0
    BACKGROUND: This study aimed to determine the accuracy of a point-of-care Bilistick method for measuring total serum bilirubin (TSB) and its turn-around-time (TAT) against hospital laboratory methods.

    METHODS: This prospective study was carried out on 561 term-gestation jaundiced neonates in two Malaysian hospitals. Venous blood sample was collected from each neonate for contemporary measurement of TSB by hospital laboratories and Bilistick. TAT was the time interval between specimen collection and TSB result reported by each method.

    RESULTS: The mean laboratory-measured TSB was 194.85 (±2.844) µmol/L and Bilistick TSB was 169.37 (±2.706) µmol/L. Pearson's correlation coefficient was: r = 0.901 (p 

    Matched MeSH terms: Jaundice, Neonatal/blood*
  9. Ainoon O, Boo NY, Yu YH, Cheong SK, Hamidah HN, Lim JH
    Malays J Pathol, 2004 Dec;26(2):89-98.
    PMID: 16329560
    We performed DNA analysis on cord blood samples of 128 Chinese male neonates diagnosed as G6PD deficiency in Hospital Universiti Kebangsaan Malaysia by a combination PCR-restriction enzyme digest technique, Single Stranded Conformation Polymorphism analysis and DNA sequencing. We found 10 different G6PD-deficient mutations exist. The two commonest alleles were G6PD Canton 1376 G>T (42.3%) and Kaiping 1388 G>A (39.4%) followed by G6PD Gaohe 592 G>A (7.0%), Chinese-5 1024 C>T, Nankang 517 T>C (1.5%), Mahidol 487 G>A (1.6%), Chatham 1003 G>T (0.8%), Union 1360 C>T (0.8%), Viangchan 871 G>A (0.8%) and Quing Yang 392 G>T (0.8%). Sixty eight percent (88/125) neonates in this study had neonatal jaundice and 29.7% developed hyperbilirubinemia >250 micromol/l. The incidence of hyperbilirubinemia >250 micromol/l was higher in G6PD Kaiping (43.8%) than G6PD Canton (22%) (p< 0.05). There was no significant difference in the incidence of neonatal jaundice, mean serum bilirubin, mean age for peak serum bilirubin, percentage of babies requiring phototherapy and mean duration of phototherapy between the two major variants. None of the 88 neonates required exchange transfusion. In conclusion we have completely characterized the molecular defects of a group of Chinese G6PD deficiency in Malaysia. The mutation distribution reflects the original genetic pool and limited ethnic admixture with indigenous Malays.
    Matched MeSH terms: Jaundice, Neonatal/blood
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links