Displaying publications 1 - 20 of 47 in total

Abstract:
Sort:
  1. Kuah KB
    Family Practitioner, 1974;1(4):10-13.
    Matched MeSH terms: Intrauterine Devices*
  2. Tan FEH
    Family Practitioner, 1984;7:60-63.
    Matched MeSH terms: Intrauterine Devices
  3. Goh TH, Tan CH, Lim SM, Chew SC, Hutapea H, Iskandar J
    Med J Malaysia, 1978 Jun;32(4):304-7.
    PMID: 732628
    Matched MeSH terms: Intrauterine Devices, Copper*
  4. Petta CA, Amatya R, Farr G, Chi I
    Contraception, 1994 Oct;50(4):339-47.
    PMID: 7813222
    The objective of this study was to evaluate possible factors associated with discontinuing use of TCu 380A IUDs due to personal reasons among 2748 users. Overall, a total of 88 subjects discontinued using the TCu 380A IUD within 12 months postinsertion for personal reasons. The most common reasons were planned pregnancy (32%) and husband or family opinion against IUD use (26%). The gross cumulative 12-month life table discontinuation rate for all personal reasons was 4.0 per 100 women. Having no education and/or living in a rural area were the sociodemographic characteristics associated with an increased risk of discontinuation for personal reasons. Effective and regular counseling about IUD use, especially among illiterate women, may help prevent IUD discontinuations related to personal reasons.
    Matched MeSH terms: Intrauterine Devices, Copper*
  5. Goh TH, Hariharan M, Tan CH
    Contraception, 1980 Oct;22(4):389-95.
    PMID: 7449387
    The increase in menstrual blood loss associated with copper-bearing IUDs may cause or aggravate pre-existing anaemia. In order to evaluate this risk, 84 Malaysian women wearing copper-IUDs were studied longitudinally by means of serial measurements of blood haemoglobin concentration (Hb), serum iron (S/Fe) and transferrin saturation (T/S). The initial Hb was under 12 gm% in 33.7% of patients. The mean Hb showed no significant change up to 12 months while S/Fe fell significantly at the end of this time; the T/S was significantly reduced as early as 6 months post-insertion. There is a significant risk of anaemia following copper-IUD insertion, particularly with long-term usage. Progestogen-releasing IUDs may offer the most feasible solution to this problem in our local context since oral medication with iron or drugs to reduce menstrual blood loss is not practicable.
    Matched MeSH terms: Intrauterine Devices, Copper*
  6. Sen CJ, Samad NHA, Huei TJ, Peng LE
    J Prim Health Care, 2021 Sep;13(3):283-286.
    PMID: 34588112 DOI: 10.1071/HC21084
    INTRODUCTION An intrauterine contraceptive device (IUCD) is a common contraception method used for family planning. IUCD erosion into adjacent organs is a rare but serious complication of IUCD use. CASE PRESENTATION A 41-year-old female presented to us with a leaking left ectopic pregnancy. Emergency laparotomy and left salpingectomy were performed. A copper ICUD was found intraperitoneally and part of it had completely eroded into the sigmoid colon. Sigmoid colotomy was performed and the IUCD was removed successfully. Further history revealed that the patient had her IUCD inserted 12 years previously but was forgotten. The patient was discharged well after 4 days of admission. DISCUSSION Erosion of an IUCD into the colon is uncommon and may be asymptomatic or present with bowel perforation and obstruction. There should be a high index of suspicion for pregnancy occurring among women post-IUCD insertion. A misplaced IUCD can cause chronic inflammation of the fallopian tube, which may alter tubal functionality and increase the risk of ectopic pregnancy. Family planning is commonly done in primary health care. Primary care education and counselling are essential to improve awareness of fertile women to prevent similar complications. Periodic examination of IUCD string either by users or primary health-care practitioners is crucial. Ultrasound can be advocated if there are difficulties with the insertion. An abdominal radiograph is useful and should be performed in the case of missing IUCDs.
    Matched MeSH terms: Intrauterine Devices*
  7. Goh TH, Hariharan M
    Contraception, 1983 Oct;28(4):329-36.
    PMID: 6667621
    Blood haemoglobin and serum ferritin levels were measured at the initial visit and 12 months following sterilization and IUD insertion. Ferritin levels were unaltered in Progestasert users after 12 months but haemoglobin values increased though not significantly. Ferritin levels fell in Multiload Cu 250 users and in sterilized women; haemoglobin levels were also observed to fall but significantly only in the latter group. Iron-deficiency anaemia was prevalent at initial contact and there appeared to be an increased risk subsequently in Multiload Cu 250 users and in those who were sterilized. Screening and monitoring for anaemia is indicated. From the viewpoint of iron status, the Progestasert is preferable to the Multiload Cu 250 but it suffers the major disadvantages of needing frequent replacement and of causing menstrual disturbances which might compromise its acceptability. Menstrual blood loss studies may help explain why anaemia develops after sterilization.
    Matched MeSH terms: Intrauterine Devices, Copper*; Intrauterine Devices, Medicated*
  8. Raman S, Sivanesaratnam V, Sinnathuray TA
    Med J Malaysia, 1981 Sep;36(3):151-4.
    PMID: 7199110
    Matched MeSH terms: Intrauterine Devices/adverse effects*; Intrauterine Devices, Copper/adverse effects
  9. Harun R, Nayar S, Thum Yin Lai
    Malays J Reprod Health, 1989 Dec;7(2):131-7.
    PMID: 12283073
    PIP: Previous studies have shown the users of intrauterine devices have a 4.4 times greater risk of pelvic inflammatory disease. This present study intends to categorize the distribution of microbes in cultures from different types of extracted copper intrauterine devices (IUCDs). Bacteriological studies of aerobic and anaerobic organisms were performed on the extracted IUCDs of 522 IUCD users; 480 wearing a Multiload Cu 250, 15 wearing a Copper T, 22 Lippes Loop and 5 a Copper 7. Cultures were negative in 46 (8.8%) IUCD cultures where 43 were Multiloads, Copper T (1) and Lippes Loop (2). 91.2% yielded bacterial growth and the commonest organisms isolated were Staphylococcus species, (23%), E.coli (9.6%) and Staphylococcus aureus (4.0%. Candida albicans, E.coli and Staphylococcus sp. were commonly isolated from Multiload, Copper T, Lippes Loop and Copper 7. Beta-hemolytic streptococci, Staphylococcus aureus and Candida sp. were frequently recovered from Multiload, Copper T and Lippes Loop. Only Multiload cultures yielded Bacillus, Streptococcus viridans, Klebsiella, Proteus, Enterobacter, Citrobacter diversus, Citrobacter freundii, Moraxella, Pseudomonas and Acinetobacter. One woman with complaint of PID yielded E.coli in her IUCD culture.
    Matched MeSH terms: Intrauterine Devices*; Intrauterine Devices, Copper*
  10. Wong CY
    Br J Fam Plann, 2000 Apr;26(2):117.
    PMID: 10896464
    Matched MeSH terms: Intrauterine Devices, Medicated*
  11. Glew S, Singh A
    Adv Contracept, 1989 Mar;5(1):51-3.
    PMID: 2782134
    A case is described of profuse uterine bleeding with a dislodged Multiload Cu 250 intrauterine device (IUD). Multiple blood transfusions were necessary, and ultimately, an emergency hysterectomy was performed.
    Matched MeSH terms: Intrauterine Devices, Copper/adverse effects*
  12. Raman S, Sivanesaratnam V
    Med J Malaysia, 1982 Mar;37(1):76-7.
    PMID: 6889674
    A case of perforation of the uterus by the Multiload CU250 Device is described. To date no perforation of the uterus by this device has been reported. The device was successfully removed under laparoscopic control.
    Matched MeSH terms: Intrauterine Devices, Copper/adverse effects*
  13. McCarthy T, Ramachandran L, Ratnam SS
    Adv Contracept, 1987 Dec;3(4):323-6.
    PMID: 3445800
    Eight-hundred patients recruited between September 1981 and December 1984 were admitted to a randomized prospective trial of the Nova T (NTCu200Ag) and Multiload 250 (MLCu250) IUDs. At the cut off date, 31 December 1986, 206 patients had completed the 4-year trial period, 379 had terminated before completion and 215 were in the fourth year of use. For the third and fourth years, the MLCu250 had a significantly lower accidental pregnancy rate (p less than 0.05).
    Matched MeSH terms: Intrauterine Devices, Copper/adverse effects*
  14. Heng GT
    Med J Malaysia, 1979 Jun;33(4):352-4.
    PMID: 522748
    Matched MeSH terms: Intrauterine Devices, Copper/utilization*
  15. Ng, Beng Kwang, Lim, PS, Shahizon AMM, Ng, YL, Shafiee MN, Omar MH
    MyJurnal
    We report a case of dislodged Levornogestrel-intrauterine system (LNG-IUS, Mirena®) without evidence of uterine perforation. A 37-year-old Para 4+1presented with 3 months history of lower abdominal pain. Examination and imaging showed that the device was not present in the uterine cavity. She underwent laparoscopic retrieval of Mirena®. There was no evidence of uterine perforation intra-operatively. This case illustrated the rare possibility of dislodged Mirena®intra-abdominally without evidence of uterine perforation. The management for missing IUS was reviewed.
    Matched MeSH terms: Intrauterine Devices, Medicated
  16. Arumugam K, Tai FM
    Med Sci Res, 1991 Mar;19(6):183.
    PMID: 12343753
    Matched MeSH terms: Intrauterine Devices; Intrauterine Devices, Copper*
  17. Kumarappan AL, Karthikeyan M, Gunaseelan D, Ros'aini P
    Med J Malaysia, 2015 Oct;70(5):312-3.
    PMID: 26556122 MyJurnal
    Intrauterine contraceptive device (IUCD) is common choice for contraception. Migration of IUCD is one of the complications that are encountered. Here we report a case of IUCD migration to the sigmoid colon. A 39-year-old Malay lady carrying a copper T type of IUCD presented with missing thread then underwent examination under anaesthesia, proceeded to hysteroscopy but failed removal. Abdominal ultrasound detected it in the left lower quadrant of abdomen. She then underwent diagnostic laparoscopy where the device was found to be embedded in the sigmoid colon. Technical difficulty necessitated conversion to mini laparotomy and sigmoidotomy to remove the IUCD and the bowel closed primarily. IUCD is a relatively simple and safe contraceptive procedure but possible complications are bleeding and pain that usually co-exist, pelvic infection, expulsion and perforation. Investigations should be based on clinical suspicion and migrated IUCD in symptomatic patients should be surgically removed whereas, asymptomatic patients can be managed conservatively under certain circumstances. However in the presence of a concurrent pathology that requires exploration then retrieval of the migrated IUCD should be undertaken.
    Matched MeSH terms: Intrauterine Devices
  18. Goh TH, Ang ES, Yip YC
    J Obstet Gynaecol (Lahore), 1983 Oct;4(2):127-8.
    PMID: 12279948
    Matched MeSH terms: Intrauterine Devices*; Intrauterine Devices, Copper*
  19. Wong CY
    J Fam Plann Reprod Health Care, 2001 Jan;27(1):56.
    PMID: 12457552 DOI: 10.1783/147118901101194976
    Hysterectomy and tubal sterilisation are two commonly performed gynaecological procedures in Malaysia. Little has been published about the psychological impact on sexuality of such operations in the Far East. Many Malaysian patients believe that surgery to the pelvic organs may be detrimental to the sexual health and needs of women. There is a widespread belief that the uterus is essential for the libido and sexual wellbeing of women. It is also believed that tubal sterilisation may result in the loss of libido and thus of sexual desire for her husband. Despite counselling to dispel these misconceptions, patients frequently refuse surgical management for fear of losing their libido and sexuality. Inability to satisfy and consummate marriage is a valid reason for the partner to find another wife (Muslims in Malaysia are legally allowed to have four wives). This fear of ultimately losing the husband to another woman due to lack of libido and loss of sexuality often causes women to refuse appropriate surgery. The recent availability of the levonorgestrel intra-uterine system (IUS) in Malaysia provides a suitable medical alternative to surgery in managing some of these patients. There is good evidence to suggest the effectiveness of the levonorgestrel IUS in the treatment of menorrhagia. The use of the levonorgestrel IUS in women whose cultural beliefs/misconceptions are not amenable to counselling, may help in the psychological preservation of their libido and sexuality.
    Matched MeSH terms: Intrauterine Devices, Medicated/utilization*
  20. Pillay B, Gregory AR, Subbiah M
    Med J Malaysia, 1994 Mar;49(1):74-7.
    PMID: 8057995
    Cervico-vaginal smears from 350 IUCD users were analysed to ascertain the range of abnormalities induced in the genital tract of these women. Alteration of the microbial environment, inflammatory, degenerative, reparative and proplastic epithelial changes were the salient cytological findings. The clinical implications of these are briefly discussed.
    Matched MeSH terms: Intrauterine Devices/adverse effects*
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links