Patent ductus arteriosus (PDA) stenting has gained acceptance for palliation in cyanotic congenital heart disease. The PDA in tetralogy of Fallot with pulmonary atresia (ToF-PA) arises, in the left aortic arch, from underneath the arch and connects to the proximal left pulmonary artery, often resulting in stenosis. The PDA is usually elongated and tortuous, making stent implantation challenging. Shorter duration of palliation, aggravation of branch pulmonary artery stenosis resulting in poor growth and difficulty at surgery makes ductal stenting controversial. Access via the carotid and axillary artery reduces complexity of the procedure and improves success, with recent data demonstrating good pulmonary artery growth. Advances in bioresorbable stents offer future promise and will likely resolve some controversies surrounding PDA stenting in ToF-PA.
We compared the result of radiofrequency (RF)-assisted valvotomy and balloon dilation with closed surgical valvotomy and Blalock Taussig (BT) shunt as primary treatment in selected patients with pulmonary atresia and intact ventricular septum (PA-IVS).
An inverted left atrial appendage is a rare phenomenon post cardiac surgery. The lesion presents as an additional mass in the left atrium, which would trigger unnecessary concerns and frequently, a battery of tests. The lesion can be easily diagnosed using echocardiography. We report a case of inverted left atrial appendage in a patient post repair of common arterial trunk. Echocardiographic pictures and features which help to identify this lesion as well as to differentiate it from other possible left atrial mass are described. This article aimed to improve the awareness of sonographers toward this rare but possible post operative lesion.
This study reviewed the short-term outcome of transcatheter closure of the defects within the oval fossa using an Amplatzer Septal Occluder. From January 1997 to December 2000, 210 patients with defects within the oval fossa underwent successful transcatheter closure. We reviewed a total of 190 patients with left-to-right shunts, assessing the patients for possible complications and the presence of residual shunts using transthoracic echocardiogram at 24 h, 1 month, 3 months and one year. Their median age was 10 years, with a range from 2 to 64 years, and their median weight was 23.9 kg, with a range from 8.9 to 79 kg. In 5 patients, a patent arterial duct was closed, and in 2 pulmonary balloon valvoplasty performed, at the same sitting. The median size of the Amplatzer device used was 20 mm, with a range from 9 to 36 mm. The median times for the procedure and fluoroscopy were 95 min, with a range from 30 to 210 min, and 18.4 min, with a range from 5 to 144 min, respectively. Mean follow-up was 20.8 +/- 12.4 months. Complete occlusion was obtained in 168 of 190 (88%) patients at 24 h, 128 of 133 (96.2%) at 3 months, and 103 of 104 (99%) at one year. Complications occurred in 4 (2.1%) patients. In one, the device became detached, in the second the device embolized into the right ventricular outflow tract, the lower end of the device straddled in the third, and the final patient had significant bleeding from the site of venupuncture. There were no major complications noted on follow-up. We conclude that transcatheter closure of defects within the oval fossa using the Amplatzer Septal Occluder is safe and effective. Long-term follow-up is required, nonetheless, before it is recommended as a standard procedure.