Displaying all 13 publications

Abstract:
Sort:
  1. Puvan IS
    Med J Malaya, 1968 Sep;23(1):41-6.
    PMID: 4237555
    Matched MeSH terms: Extraction, Obstetrical*
  2. Achanna S, Monga D
    Singapore Med J, 1994 Dec;35(6):605-8.
    PMID: 7761886
    The outcome of 100 patients undergoing instrumental delivery with vacuum extractor is compared with that of 100 women delivered with the aid of obstetric forceps. Forceps deliveries were more commonly associated with maternal birth canal trauma (including episiotomy) whilst vacuum extractor carried higher odds of the neonate developing jaundice. Apart from these, there were no significant differences between these two groups in terms of maternal morbidity, neonatal trauma and morbidity and ultimate outcome (success with the type of instrument used). We conclude that with meticulous handling of the instrument and with an appropriate decision on the indication and the type of instrument used, the maternal and neonatal outcome could be equally good with the use of either instrument.
    Matched MeSH terms: Vacuum Extraction, Obstetrical/adverse effects*; Vacuum Extraction, Obstetrical/methods
  3. Lee HY, Subramaniam N, Nordin MM
    Singapore Med J, 1996 Feb;37(1):55-60.
    PMID: 8783915
    To compare the advantages and disadvantages of the New Bird metal cups and silicone cups in terms of maternal and foetal outcome. To study the adverse effects and factors associated with failed vacuum deliveries.
    Matched MeSH terms: Vacuum Extraction, Obstetrical/adverse effects; Vacuum Extraction, Obstetrical/methods*; Vacuum Extraction, Obstetrical/contraindications
  4. Boo NY
    Singapore Med J, 1990 Jun;31(3):207-10.
    PMID: 2392696
    In a 30-month prospective study, between January 1987 and June 1989, 101 of 64,424 Malaysian neonates (1.6 per 1000 livebirths) born in the Maternity Hospital, Kuala Lumpur were found to have subaponeurotic haemorrhage shortly after delivery. The incidence was highest in neonates weighting 4000 gm or more. There was no significant difference in incidence of this condition in neonates of different ethnic origins. Hypoprothrombinemia was present in only 5/101 (5.0%) of the affected neonates. Sixty seven (66.3%) of the neonates with subaponeurotic haemorrhage had history of trial of vacuum extraction. The incidence of subaponeurotic haemorrhage was significantly higher in neonates delivered by vacuum extraction than by other modes of delivery in this hospital (41.4 per 1000 livebirths in neonates delivered by vacuum extraction versus 1.0 per 1000 livebirths in neonates delivered by other modes). Those neonates who developed subaponeurotic haemorrhage without trial of vacuum extraction had a history of either prolonged labour or difficult delivery. Thirty-three (32.7%) of the neonates with subaponeurotic haemorrhage developed anaemia which required blood transfusion and 3/33 (9.1%) were in shock. Fifty seven (56.4%) of the neonates with subaponeurotic haemorrhage developed hyperbilirubinemia due to the haemorrhage. Four (7.0%) of them had severe unconjugated hyperbilirubinemia which required exchange transfusion. The results of this study suggest that subaponeurotic haemorrhage in Malaysian neonates was commonly associated with vacuum extraction and was not a benign condition.
    Matched MeSH terms: Extraction, Obstetrical/adverse effects*; Vacuum Extraction, Obstetrical/adverse effects*
  5. SAMBHI JS
    Med J Malaysia, 1963 Jun;17:292-301.
    PMID: 14060507
    Matched MeSH terms: Extraction, Obstetrical*
  6. Ismail NA, Saharan WS, Zaleha MA, Jaafar R, Muhammad JA, Razi ZR
    J Obstet Gynaecol Res, 2008 Jun;34(3):350-3.
    PMID: 18686348
    AIM: To compare the success, clinical outcomes, and maternal and neonatal complications between the Kiwi Omnicup and the Malmstrom metal cup in vacuum assisted delivery.

    METHODS: This was a prospective randomized comparative trial. Women who required vacuum assisted vaginal delivery were randomized into the Kiwi Omnicup (KO) group and the Malmstrom metal cup (MM) group. The vacuum assisted deliveries were conducted according to hospital protocol. Details of the procedure and delivery outcomes including success and complications were analyzed.

    RESULTS: One hundred and sixty-four women were recruited - 85 were assigned to vacuum assisted delivery using the KO and 79 the MM. One hundred percent delivery success was achieved with no significant differences between the two instruments in terms of maternal morbidity (P = 0.66). Six women in the MM group sustained post delivery complications in comparison to five in the KO group. Three babies were diagnosed with birth asphyxia in each group. More babies in the MM group were admitted to the Neonatal Intensive Care Unit (NICU) (10 babies versus 5 babies) and suffered complications (14 versus 12 babies), compared to the KO group, although the difference was not statistically significant. There were no intrapartum or neonatal deaths and of those admitted to the NICU, all were discharged within a week without any serious consequences.

    CONCLUSION: Kiwi Omnicup is an effective alternative to the currently available Malmstrom metal cup for vacuum assisted delivery with no increase in maternal or neonatal morbidity or mortality.

    Matched MeSH terms: Vacuum Extraction, Obstetrical/adverse effects; Vacuum Extraction, Obstetrical/instrumentation*
  7. Ghani AR, Prakash RG, Abdullah J
    Med J Malaysia, 2006 Mar;61(1):100-2.
    PMID: 16708744 MyJurnal
    We report one case of posterior fossa intracranial haemorrhage in a full-term Malay baby boy following vacuum assisted delivery. The patient, a term baby boy was delivered by a vacuum extraction and later developed signs of increased intracranial pressure 72 hours after birth. Computed tomography (CT) of the brain showed a posterior fossa intracranial haemorrhage with acute obstructive hydrocephalus. He was initially treated with isolated ventricular shunting which later caused an upward cerebellar herniation. An immediate suboccipital craniectomy for evacuation of cerebellar haematoma was performed which resulted in a gradual recovery.
    Matched MeSH terms: Vacuum Extraction, Obstetrical/adverse effects*; Vacuum Extraction, Obstetrical/instrumentation
  8. Trutnovsky G, Kamisan Atan I, Martin A, Dietz HP
    BJOG, 2016 Aug;123(9):1551-6.
    PMID: 26435045 DOI: 10.1111/1471-0528.13692
    OBJECTIVE: To analyse the associations between delivery mode and symptoms and signs of pelvic organ prolapse (POP) in a cohort of symptomatic women.

    DESIGN: Retrospective observational study.

    POPULATION: A total of 1258 consecutive women attending a tertiary urogynaecological unit for the investigation of lower urinary tract or pelvic floor disorders between January 2012 and December 2014.

    METHODS: Obstetric history and clinical examination data were obtained from the unit database. Prolapse quantification on imaging was performed using stored four-dimensional translabial ultrasound volume data sets. Women were grouped into four groups according to the most traumatic delivery reported. The presence of symptoms and signs of POP were compared between delivery groups while controlling for potential confounders.

    MAIN OUTCOME MEASURES: Prolapse symptoms, visual analogue score for prolapse bother, International Continence Society Prolapse Quantification System findings and ultrasound findings of anterior, central and posterior compartment descent.

    RESULTS: Nulliparae showed the lowest prevalence of most measures of POP, followed by women exclusively delivered by caesarean section. Highest prevalences were consistently found in women delivered at least once by forceps, although the differences between this group and women delivered by normal vaginal delivery and/or vacuum extraction were significant in three out of eight measures only. Compared with women in the caesarean section group, the adjusted odds ratios for reporting symptoms of prolapse were 2.4 (95% CI 1.30-4.59) and 3.2 (95% CI 1.65-6.12) in the normal vaginal delivery/vacuum extraction group and forceps group, respectively.

    CONCLUSIONS: There is a clear link between vaginal delivery and symptoms and signs of pelvic organ prolapse in urogynaecological patients.

    TWEETABLE ABSTRACT: Compared with caesarean section a history of vaginal delivery more than doubles the risk for POP.

    Matched MeSH terms: Extraction, Obstetrical/statistics & numerical data*; Vacuum Extraction, Obstetrical/statistics & numerical data
  9. Kamisan Atan I, Lai SK, Langer S, Caudwell-Hall J, Dietz HP
    Int Urogynecol J, 2019 06;30(6):917-923.
    PMID: 30741317 DOI: 10.1007/s00192-019-03887-z
    INTRODUCTION AND HYPOTHESIS: Forceps delivery and length of second stage are risk factors of maternal birth trauma, i.e., levator ani muscle (LAM) avulsion and anal sphincter trauma. The cesarean section (CS) rate has recently become the key performance indicator because of its increase worldwide. Attempts to reduce CS rates seem to have led to an increase in forceps deliveries and longer second stages. This study aimed to determine the association between variations in obstetric practice (between hospitals) and maternal birth trauma.

    METHODS: This was a retrospective ancillary analysis involving 660 nulliparous women carrying an uncomplicated singleton term pregnancy in a prospective perinatal intervention trial at two Australian tertiary obstetric units. They had been seen antenatally and at 3-6 months postpartum for a standardized clinical assessment between 2007 and 2014. Primary outcome measures were sonographically diagnosed LAM and external anal sphincter (EAS) trauma.

    RESULTS: The incidence of LAM avulsion (11.5% vs. 21.3%, P = 0.01) and composite trauma, i.e., LAM avulsion ± EAS injury (29.2% vs. 39.7%, P = 0.03) were higher in one of the two hospitals, where the forceps delivery rate was also higher (10.9% vs. 2.6%, P 

    Matched MeSH terms: Extraction, Obstetrical/instrumentation; Extraction, Obstetrical/statistics & numerical data*
  10. Siti Hayati Mohd Nahwari, Bahiyah Abdullah, Suzanna Daud, Norhana Mohd Kasim, Norhana Mohd Kasim
    MyJurnal
    This case series highlights the outcome of four pregnancies complicated with COVID-19, as
    the pandemic of coronavirus disease 2019 (COVID-19) poses a lot of uncertainties due to lack
    of scientific evidence in guiding the management of pregnancy with COVID-19. The women
    were between 25 and 31 years of age and of 35 - 39 weeks of gestation with no underlying
    medical problems. Three women were delivered via caesarean section and one woman was
    delivered via ventouse delivery due to poor progress during the second stage of labour. Two
    women were in stage 4 of the disease (having breathing difficulties and requiring oxygen
    support) at presentations. One of them was treated with hydroxychloroquine (HC) only while
    another one was treated with both HC and antiviral medications; none required assisted
    ventilation during their hospitalizations. There is no vertical transmission of COVID-19 disease
    observed in this case series.
    Matched MeSH terms: Vacuum Extraction, Obstetrical
  11. Boo NY, Foong KW, Mahdy ZA, Yong SC, Jaafar R
    BJOG, 2005 Nov;112(11):1516-21.
    PMID: 16225572
    To determine obstetric and neonatal risk factors associated with subaponeurotic haemorrhage (SAH) in infants exposed to vacuum extraction.
    Matched MeSH terms: Vacuum Extraction, Obstetrical/adverse effects*
  12. Lee SH, Cheah DS, Poopalarachagan S, Sivanesaratnam V
    Aust N Z J Obstet Gynaecol, 1991 Nov;31(4):372-5.
    PMID: 1799358
    Major perineal injuries following obstetrical complications represent difficult problems of reconstruction. We describe 2 such patients with perineal injuries simulating infantile cloacas. Surgical repair using an abdominoperineal pullthrough procedure in 1 patient, and a Bricker loop type of repair in another resulted in successful restoration of function in both. The operative details and basis for the reconstruction are described.
    Matched MeSH terms: Extraction, Obstetrical/adverse effects
  13. Thompson B, Baird D
    J Obstet Gynaecol Br Commonw, 1967 Aug;74(4):510-22.
    PMID: 6033271
    Matched MeSH terms: Extraction, Obstetrical
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links