Displaying publications 1 - 20 of 22 in total

Abstract:
Sort:
  1. Kamangar S, Kalimuthu G, Badruddin IA, Badarudin A, Ahmed NJ, Khan TM
    ScientificWorldJournal, 2014;2014:354946.
    PMID: 25258722 DOI: 10.1155/2014/354946
    The present study deals with the functional severity of a coronary artery stenosis assessed by the fractional flow reserve (FFR). The effects of different geometrical shapes of lesion on the diagnostic parameters are unknown. In this study, 3D computational simulation of blood flow in three different geometrical shapes of stenosis (triangular, elliptical, and trapezium) is considered in steady and transient conditions for 70% (moderate), 80% (intermediate), and 90% (severe) area stenosis (AS). For a given percentage AS, the variation of diagnostic parameters which are derived from pressure drop across the stenosis was found in three different geometrical shapes of stenosis and it was observed that FFR is higher in triangular shape and lower in trapezium shape. The pressure drop coefficient (CDP) was higher in trapezium shape and lower in triangular model whereas the LFC shows opposite trend. From the clinical perspective, the relationship between percentage AS and FFR is linear and inversely related in all the three models. A cut-off value of 0.75 for FFR was observed at 76.5% AS in trapezium model, 79.5% in elliptical model, and 82.7% AS for the triangular shaped model. The misinterpretation of the functional severity of the stenosis is in the region of 76.5%-82.7 % AS from different shapes of stenosis models.
    Matched MeSH terms: Coronary Stenosis/diagnosis; Coronary Stenosis/pathology*; Coronary Stenosis/physiopathology*
  2. Choo GH
    J Interv Cardiol, 2009 Apr;22(2):117-20.
    PMID: 19379469 DOI: 10.1111/j.1540-8183.2009.00443.x
    Percutaneous bifurcation intervention is usually sufficient with a single-stent strategy. When the double-stent strategy is employed, higher restenosis and target lesion revascularization (TLR) rates are observed, especially at the side-branch ostium. The results may be improved, however, with refinement in techniques, for example, final kissing balloon inflation and double kissing balloon inflation.
    Matched MeSH terms: Coronary Stenosis/therapy*
  3. Govindaraju K, Kamangar S, Badruddin IA, Viswanathan GN, Badarudin A, Salman Ahmed NJ
    Atherosclerosis, 2014 Apr;233(2):630-635.
    PMID: 24549189 DOI: 10.1016/j.atherosclerosis.2014.01.043
    Functional assessment of a coronary artery stenosis severity is generally assessed by fractional flow reserve (FFR), which is calculated from pressure measurements across the stenosis. The purpose of this study is to investigate the effect of porous media of the stenosed arterial wall on this diagnostic parameter. To understand the role of porous media on the diagnostic parameter FFR, a 3D computational simulations of the blood flow in rigid and porous stenotic artery wall models are carried out under steady state and transient conditions for three different percentage area stenoses (AS) corresponding to 70% (moderate), 80% (intermediate), and 90% (severe). Blood was modeled as a non Newtonian fluid. The variations of pressure drop across the stenosis and diagnostic parameter were studied in both models. The FFR decreased in proportion to the increase in the severity of the stenosis. The relationship between the percentage AS and the FFR was non linear and inversely related in both the models. The cut-off value of 0.75 for FFR was observed at 81.89% AS for the rigid artery model whereas 83.61% AS for the porous artery wall model. This study demonstrates that the porous media consideration on the stenotic arterial wall plays a substantial role in defining the cut-off value of FFR. We conclude that the effect of porous media on FFR, could lead to misinterpretation of the functional severity of the stenosis in the region of 81.89 %-83.61% AS.
    Matched MeSH terms: Coronary Stenosis/diagnosis; Coronary Stenosis/pathology*
  4. Govindaraju K, Viswanathan GN, Badruddin IA, Kamangar S, Salman Ahmed NJ, Al-Rashed AA
    Comput Methods Biomech Biomed Engin, 2016 Nov;19(14):1541-9.
    PMID: 27052093 DOI: 10.1080/10255842.2016.1170119
    This study aims to investigate the influence of artery wall curvature on the anatomical assessment of stenosis severity and to identify a region of misinterpretation in the assessment of per cent area stenosis (AS) for functionally significant stenosis using fractional flow reserve (FFR) as standard. Five artery models of different per cent AS severity (70, 75, 80, 85 and 90%) were considered. For each per cent AS severity, the angle of curvature of the arterial wall varied from straight to an increasingly curved model (0°, 30°, 60°, 90° and 120°). Computational fluid dynamics was performed under transient physiologic hyperemic flow conditions to investigate the influence of artery wall curvature on the pressure drop and the FFR. The findings in this study may be useful in in vitro anatomical assessment of functionally significant stenosis. The FFR decreased with increasing stenosis severity for a given curvature of the artery wall. Moreover, a significant decrease in FFR was found between straight and curved models discussed for a given severity condition. These findings indicate that the curvature effect was included in the FFR assessment in contrast to minimum lumen area (MLA) or per cent AS assessment. The MLA or per cent AS assessment may lead to underestimation of stenosis severity. From this numerical study, an uncertainty region could be evaluated using the clinical FFR cutoff value of 0.8. This value was observed at 81.98 and 79.10% AS for arteries with curvature angles of 0° and 120° respectively. In conclusion, the curvature of the artery should not be neglected in in vitro anatomical assessment.
    Matched MeSH terms: Coronary Stenosis/pathology*; Coronary Stenosis/physiopathology*
  5. Moosavi Tayebi R, Wirza R, Sulaiman PS, Dimon MZ, Khalid F, Al-Surmi A, et al.
    J Cardiothorac Surg, 2015;10:58.
    PMID: 25896185 DOI: 10.1186/s13019-015-0249-2
    Computerized tomographic angiography (3D data representing the coronary arteries) and X-ray angiography (2D X-ray image sequences providing information about coronary arteries and their stenosis) are standard and popular assessment tools utilized for medical diagnosis of coronary artery diseases. At present, the results of both modalities are individually analyzed by specialists and it is difficult for them to mentally connect the details of these two techniques. The aim of this work is to assist medical diagnosis by providing specialists with the relationship between computerized tomographic angiography and X-ray angiography.
    Matched MeSH terms: Coronary Stenosis/diagnosis; Coronary Stenosis/radiography*
  6. Ahamad NA, Kamangar S, Badruddin IA
    Biomed Mater Eng, 2018;29(3):319-332.
    PMID: 29578467 DOI: 10.3233/BME-181734
    The current study investigates the curvature effect due to various angles of curvature on the blood flow in human artery. The stenosis is considered to have three sizes 70%, 80% and 90% blockage before the curve section of artery. Numerical study of four different angle of curvature was considered to understand the flow behavior of artery having various curvatures, on the hemodynamics factors that includes drop in arterial pressure, flow velocity as well as wall shear stress. It was found that, the augmentation of the flow resistance due to the curvature increases in presence of stenosis. It was also noted that the wall shear is higher at the outer wall as compared to the inside wall in four models considered. Results showed that both the curvature of artery and size of the stenosis have significant impact. These two factors should be considered by cardiologist to assess the complexity of stenosis.
    Matched MeSH terms: Coronary Stenosis/pathology; Coronary Stenosis/physiopathology*
  7. Leenders GE, Liew HB, Stella PR
    Cardiovasc Revasc Med, 2018 12;19(8S):58-59.
    PMID: 30115559 DOI: 10.1016/j.carrev.2018.03.016
    A 62-year old male underwent treatment of a bifurcation lesion in the left anterior descending coronary artery using provisional stenting with a jailed wire technique. Severe longitudinal stent deformation and unravelment of the stent part proximal of the bifurcation occurred when we tried to pull the jailed wire from the side branch. The described case poses a caution on the use of this specific stent(-design) in bifurcation lesions.
    Matched MeSH terms: Coronary Stenosis/diagnosis; Coronary Stenosis/surgery*
  8. Ngow H
    Kardiol Pol, 2009 Sep;67(9):1040-2 discussion 1043.
    PMID: 19838965
    Coronary artery stent dislodgement during angioplasty is a rare complication. Stent dislodgement was more frequent in the past when stents were manually crimped onto the balloon. Newer and improved balloon-mounted stents with better radio-opacity have reduced the incidence of stent dislodgement but do not completely eliminate it. We report a case of balloon-mounted stent dislodgement in the proximal left anterior descending (LAD) coronary artery prior to deployment. This patient however was successfully treated with re-wiring of the artery with two parallel wires and the stent's reposition prior to deployment with the help of a small balloon.
    Matched MeSH terms: Coronary Stenosis/etiology; Coronary Stenosis/therapy*
  9. Boo YL, Liam CCK, Lim SY, Look ML
    Hong Kong Med J, 2019 Feb;25(1):74-5.
    PMID: 30713145 DOI: 10.12809/hkmj176972
    Matched MeSH terms: Coronary Stenosis/chemically induced*; Coronary Stenosis/surgery
  10. Kaur M, Rahimi R, Razali F, Mohd Noor N, Omar E, Abdul Manaf Z, et al.
    Malays J Pathol, 2019 Aug;41(2):177-183.
    PMID: 31427553
    INTRODUCTION: Coronary artery disease (CAD) is a known cause of major cardiovascular events and calcium score (CS) has been developed as a marker of coronary atherosclerosis. Yet, the relationship between post mortem computed tomography (PMCT) CS with histologically observed calcification and the severity of coronary artery stenosis has not been widely explored and is still unclear. This study aims to determine the association between coronary artery PMCT CS with histologically observed calcification and degree of stenosis of coronary arteries in post-mortem cases.

    MATERIALS & METHODS: This was a cross-sectional study involving 101 subjects recruited from the National Institute of Forensic Medicine (IPFN) Hospital Kuala Lumpur (HKL) over a period of 15 months, from December 2012 until April 2014. PMCT CS of the coronary arteries was calculated using Agatston-Janowitz score. Histological presence of calcification was observed and the degree of stenosis was calculated using an image analysis technique.

    RESULTS: PMCT CS increased with increasing severity of stenosis (p<0.001). PMCT CS showed a positive correlation with the presence of calcification (r=-0.82, p<0.001).

    CONCLUSION: Calcium score is strongly associated with coronary artery calcification and the degree of luminal stenosis in post mortem subjects. Thus, PMCT may be useful as a non-invasive tool in diagnosing CAD in the event that an autopsy is not possible.

    Matched MeSH terms: Coronary Stenosis
  11. Oteh M, Azarisman SM, Hanim NM, Noorfaizan S
    Singapore Med J, 2009 Feb;50(2):e76-8.
    PMID: 19296018
    Congenital coronary artery anomalies are rare, with an incidence of about 0.06-1.3 percent of all patients undergoing cardiac catheterisation. They are commonly asymptomatic, but potentially serious lesions may lead to myocardial ischaemia, infarction and/or sudden cardiac death. The occurrence of a concomitant stenotic lesion is exceedingly rare. We report an 80-year-old man who presented with acute anterior myocardial infarction. Coronary angiography revealed severe proximal left anterior descending (LAD) and arteriovenous malformation (AVM) from the first septal branch of the LAD. The LAD stenosis and the AVM were successfully treated with two Jomed covered stents.
    Matched MeSH terms: Coronary Stenosis/diagnosis*; Coronary Stenosis/pathology*; Coronary Stenosis/therapy
  12. Ong TK, Chin SP, Chan WL, Liew CK, Seyfarth MT, Liew HB, et al.
    Med J Malaysia, 2005 Dec;60(5):629-36.
    PMID: 16515115
    The accuracy of multi-detector computed tomographic (MDCI) coronary angiography (CTA) is dependant on image quality as well as the experience of the operator. Established centers have reported negative predictive values of over 95%. The aim of our study was to investigate the accuracy and feasibility of CTA for the assessment of haemodynamically significant coronary stenosis in a center with very early experience (<6 months) utilizing the improved spatial and temporal resolutions of the latest generation 64-row MDCI scanner. One hundred and twenty eight patients (93 male, 35 female; mean age 56.2 +/- 9.5 years) with suspected or known coronary artery disease underwent both CIA and conventional coronary angiographv (CCA). The sensitivity, specificity, positive (PPV) and negative (NPV) predictive values for stenoses > or =50% by CIA compared to CCA were 70%, 97%, 70% and 97% respectively. Evaluation of main and proximal segments in patients with good quality images (78% of patients) produced values of 94%, 95%, 74% and 99% respectively. The improved spatial and temporal resolutions of 64-row MJ) CT provided a high negative predictive value in assessing significant coronary artery stenosis even in a centre with very early experience. However, new centers embarking on CTA might not be able to reproduce the results reported by more experienced centers.
    Matched MeSH terms: Coronary Stenosis/radiography*
  13. Chee KH, Siaw FS, Chan CG, Chong WP, Imran ZA, Haizal HK, et al.
    Int J Clin Pract, 2005 Jun;59(6):628-31.
    PMID: 15924588
    This single centre study was designed to demonstrate feasibility, safety and efficacy of the Vivant Z stent (PFM AG, Cologne, Germany). Patients with de novo lesion were recruited. Coronary angioplasty was performed with either direct stenting or after balloon predilatation. Repeated angiogram was performed 6 months later or earlier if clinically indicated. Between January to June 2003, a total of 50 patients were recruited (mean age 55.8 +/- 9 years). A total of 52 lesions were stented successfully. Mean reference diameter was 2.77 mm (+/-0.59 SD, range 2.05-4.39 mm) with mean target lesion stenosis of 65.5% (+/-11.6 SD, range 50.1-93.3%). Forty-six lesions (88.5%) were American College of Cardiologist/American Heart Association class B/C types. Direct stenting was performed in 18 (34.6%) lesions. Mean stent diameter was 3.18 mm (+/-0.41 SD, range 2.5-4 mm), and mean stent length was 14.86 mm (+/-2.72 SD, range 9-18 mm). The procedure was complicated in only one case which involved the loss of side branch with no clinical sequelae. All treated lesions achieved Thrombolysis In Myocardial Infarction 3 flow. Mean residual diameter stenosis was 12.2% (+/-7.55 SD, range 0-22.6%) with acute gain of 1.72 mm (+/-0.50 SD, range 0.5-2.8). At 6 months, there was no major adverse cardiovascular event. Repeated angiography after 6 months showed a restenosis rate of 17% (defined as >50% diameter restenosis). Mean late loss was 0.96 mm (+/-0.48 SD) with loss index of 0.61 (+/-0.38 SD). The restenosis rate of those lesions less than 3.0 mm in diameter was 22.2% compared with 6.25% in those lesions more than 3.0 mm in diameter. The Vivant Z stent was shown to be safe and efficacious with low restenosis rate in de novo coronary artery lesion.
    Matched MeSH terms: Coronary Stenosis/surgery*
  14. Kamangar S, Badruddin IA, Ameer Ahamad N, Soudagar MEM, Govindaraju K, Nik-Ghazali N, et al.
    Biomed Mater Eng, 2017;28(3):257-266.
    PMID: 28527189 DOI: 10.3233/BME-171672
    The current study investigates the effect of multi stenosis on the hemodynamic parameters such as wall pressure, velocity and wall shear stress in the realistic left coronary artery. Patients CT scan image data of normal and diseased left coronary artery was chosen for the reconstruction of 3D coronary artery models. The diseased 3D model of left coronary artery shows a narrowing of more than 70% and 80% of area stenosis (AS) at the left main stem (LMS) and left circumflex (LCX) respectively. The results show that the decrease in pressure was found downstream to the stenosis as compared to the coronary artery without stenosis. The maximum pressure drop was noted across the 80% AS at the left circumflex branch. The recirculation zone was also observed immediate to the stenosis and highest wall shear stress was found across the 80% area stenosis. Our analysis provides an insight into the distribution of wall shear stress and pressure drop, thus improving our understanding on the hemodynamics in realistic coronary artery.
    Matched MeSH terms: Coronary Stenosis/pathology*
  15. Chainchel Singh MK, Abdul Rashid SN, Abdul Hamid S, Mahmood MS, Feng SS, Mohd Nawawi H, et al.
    Forensic Sci Int, 2020 Mar;308:110171.
    PMID: 32032870 DOI: 10.1016/j.forsciint.2020.110171
    BACKGROUND: Post-mortem Computed Tomography (PMCT) allows non-invasive or minimally invasive detection of findings that may or may not be visible during conventional autopsy, however, it does not allow the investigator to draw any conclusions regarding patency of the vessel's lumen. To address this deficiency, Post-mortem Computed Tomography Angiography (PMCTA) utilizing different contrast media and techniques have been introduced with various studies looking at the correlation between PMCTA, autopsy (gross) findings and coronary artery histology in diagnosing coronary artery disease.

    OBJECTIVES: The aim of this study is to investigate the sensitivity and specificity of PMCTA in diagnosing coronary artery stenosis using water-based contrast media introduced though the vessels of the neck, compared to the gold standard of diagnosis i.e. gross and histological evaluation of the coronary artery.

    METHOD: This was a cross sectional study of 158 arterial sections involving 37 subjects recruited from the National Institute of Forensic Medicine (IPFN), Hospital Kuala Lumpur (HKL). An unenhanced PMCT was performed followed by PMCTA using water-based contrast media introduced though the vessels of the neck. Coronary artery stenosis was determined using multiplanar reconstructionD while the degree of stenosis was determined by calculating the percentage of luminal diameter divided by the diameter of the vessel internal elastic.

    RESULTS: The analysis of PMCTA and histopathology examinations revealed a sensitivity of 61.5%, specificity of 91.7%; positive predictive value (PPV) of 40.0% and negative predictive value (NPV) of 96.4%.

    CONCLUSION: PMCTA utilizing water-based contrast introduced though the vessels of the neck yielded similar results as other methods and techniques of PMCTA. We would therefore conclude that PMCTA utilizing this technique could be used to assess the degree of calcification and the presence of significant stenosis.

    Matched MeSH terms: Coronary Stenosis/diagnosis*
  16. Kamangar S, Badruddin IA, Badarudin A, Nik-Ghazali N, Govindaraju K, Salman Ahmed NJ, et al.
    Comput Methods Biomech Biomed Engin, 2017 Mar;20(4):365-372.
    PMID: 27612619 DOI: 10.1080/10255842.2016.1233402
    The current study investigates the hyperemic flow effects on heamodynamics parameters such as velocity, wall shear stress in 3D coronary artery models with and without stenosis. The hyperemic flow is used to evaluate the functional significance of stenosis in the current era. Patients CT scan data of having healthy and coronary artery disease was chosen for the reconstruction of 3D coronary artery models. The diseased 3D models of coronary artery shows a narrowing of >50% lumen area. Computational fluid dynamics was performed to simulate the hyperemic flow condition. The results showed that the recirculation zone was observed immediate to the stenosis and highest wall shear stress was observed across the stenosis. The decrease in pressure was found downstream to the stenosis as compared to the coronary artery without stenosis. Our analysis provides an insight into the distribution of wall shear stress and pressure drop, thus improving our understanding of hyperemic flow effect under both conditions.
    Matched MeSH terms: Coronary Stenosis/physiopathology*
  17. Borhanuddin BK, Abdul Latiff H, Mohamed Yusof AK
    Cardiol Young, 2022 Dec;32(12):1994-1998.
    PMID: 35707919 DOI: 10.1017/S1047951122000154
    BACKGROUND: CT is an accepted non-invasive imaging tool to assess the coronary arteries in adults; however, its utilisation in children is limited by high heart rate and lack of standardised protocol. We sought to assess diagnostic quality and factors that affect image quality of CT in assessing coronary artery lesions in Kawasaki patients less than 18 years of age.

    METHODOLOGY: CT coronary angiography was performed on patients with Kawasaki disease diagnosed with coronary aneurysm or suspected to have coronary stenosis. Studies were performed using electrocardiogram-gated protocols. General anaesthesia was used in patients who were not cooperative for breathing control. Heart rate, image quality, and effective radiation dose were documented.

    RESULTS: Fifty-two Kawasaki patients underwent CT coronary angiography to assess coronary artery lesions. Median heart rate was 88 beats per minute (range 50-165 beats/minute). Image quality was graded as excellent in 34 (65%) patients, good in 17 (32%), satisfactory in 1, and poor in 1 patient. Coronary artery aneurysm was found in 25 (bilateral = 6, unilateral = 19, multiple = 11). Thrombus was found in 11 patients resulting in partial and total occlusion in 8 and 3 patients, respectively. Coronary stenosis was noted in 2 patients. The effective radiation dose was 1.296 millisievert (median 0.81 millisievert). Better diagnostic imaging quality was significantly related to lower heart rate (p = 0.007).

    CONCLUSION: Electrocardiogram-triggered CT coronary angiography provides a good diagnostic assessment of coronary artery lesions in children with Kawasaki disease.

    Matched MeSH terms: Coronary Stenosis*
  18. Al-Muhaidb SM, Aljebreen AMM, AlZamel ZA, Fathala A
    Coron Artery Dis, 2021 May 01;32(3):179-183.
    PMID: 32769402 DOI: 10.1097/MCA.0000000000000937
    OBJECTIVES: A higher coronary artery calcium score (CACS) is associated with increased coronary artery plaque burden resulting in increased cardiovascular risk. Conversely, the absence of calcium indicates a low risk of cardiovascular events. However, coronary plaque calcification is a late manifestation of atherosclerosis; earlier stages of atherosclerosis present noncalcified plaques (NCPs) A recent study demonstrated that the absence of coronary artery calcification deposit does not preclude obstructive stenosis or the need for revascularization in patients with a high suspicion of coronary artery disease (CAD). Our study aimed to investigate the prevalence of NCP and the severity of coronary artery stenosis in symptomatic patients in our local population who were referred for coronary artery computed tomography angiogram (CCTA) with 0 CACS.

    METHODS: A total of 299 patients who had undergone CACS and CCTA, and had scored zero for coronary artery calcium. Patients included had clinically appropriate indications, mainly chest pain with variable severity with no history of CAD. The presence of CAD risk factors, such as diabetes, hypertension, and smoking, was obtained from reviewing patient charts. The CCTA analysis was performed to evaluate for coronary artery stenosis and the presence of NCP. The severity of stenosis was quantified by visual estimation and divided into 0% stenosis, 1-25% stenosis, 26-50% stenosis, and more than 50% stenosis.

    RESULTS: The prevalence of NCP was 6.4% (19 of the 299). Among the 19 patients with NCP, 52.6% had no identified coronary artery stenosis, 26.3% had less than 25%, and 21% had stenosis between 25 and 50%. None had stenosis greater than 50%. There was a strong association between male sex (P = 0.001), smoking (P = 0.0.004), hypertension, and NCP (P = 0.042), but no association was found between NCP and age or diabetes.

    CONCLUSIONS: In patients with a high clinical suspicion of CAD, the absence of coronary artery calcification does not rule out CAD; up to 6.4% of these patients have early CAD as evidenced by NCP detected by CCTA, and none have more than 50% stenosis, However, future prognostic and long-term follow-up studies are needed to determine prognostic value of NCP in patients with 0 CACS.

    Matched MeSH terms: Coronary Stenosis/epidemiology*
  19. Chin K
    EuroIntervention, 2011 May;7 Suppl K:K43-6.
    PMID: 22027726 DOI: 10.4244/EIJV7SKA7
    In-stent restenosis remains an important issue even in the drug-eluting stent (DES) era today. In recent years, drug-eluting balloons (DEB) have emerged as a potential alternative to the treatment of in-stent restenosis. Paclitaxel was identified as the primary drug for DEB because of its rapid uptake and prolonged retention. Non-stent-based local drug delivery using DEB maintains the antiproliferation properties of DES, but without the limitations of DES such as subacute stent thrombosis, stent fractures, prolonged antiplatelet therapy and more importantly, avoiding a "stent-in-a-stent" approach. The first major impact of drug-eluting balloon (DEB) in the management of bare metal instent restenosis was the "PACCOCATH ISR I" randomised trial, comparing the efficacy of drug-eluting balloon versus uncoated balloon. The six months angiographic results showed a binary restenosis of 5% and 4% MACE in the drug-eluting balloon group, compared with 43% binary restenosis and 31% MACE, in the uncoated balloon group (p=0.002 and 0.02). The second major DEB trial is the "PEPCAD II Trial", comparing the efficacy of the SeQuent Please DEB with the Taxus drug-eluting stent in the treatment of bare-metal stent instent restenosis. At 6-month follow-up, in-segment late lumen loss was 0.38 ± 0.61 mm in the DES group versus 0.17 ± 0.42 mm (p=0.03) in the DEB group, resulting in a binary restenosis rate of 12/59 (20%) versus 4/57 (7%; p=0.06). At 12 months, MACE rates were 22% in the Taxus group and 9% in the DEB group (P=0.08). The TLR at 12 months was 15% in the Taxus group and 6% in the DEB group (p=0.15). Based on these two pivotal trials, the European Society of Cardiology Guidelines for Percutaneous Coronary Intervention (2010) recommended that DEB should be considered for the treatment of in-stent restenosis after prior bare-metal stent. This was accorded a class 2 IIa indication, with a level B evidence.
    Matched MeSH terms: Coronary Stenosis/etiology; Coronary Stenosis/prevention & control*
  20. Ali RM, Degenhardt R, Zambahari R, Tresukosol D, Ahmad WA, Kamar Hb, et al.
    EuroIntervention, 2011 May;7 Suppl K:K83-92.
    PMID: 22027736 DOI: 10.4244/EIJV7SKA15
    Coronary lesions in diabetics (DM) are associated with a high recurrence following percutaneous coronary intervention (PCI), even after drug-eluting stent (DES) deployment. Encouraging clinical data of the drug-eluting balloon catheter (DEB) SeQuent Please warrant its investigation in these patients.
    Matched MeSH terms: Coronary Stenosis/mortality; Coronary Stenosis/radiography; Coronary Stenosis/therapy*