Displaying all 10 publications

Abstract:
Sort:
  1. Allinjawi K, Sharanjeet-Kaur SK, Akhir SM, Mutalib HA
    F1000Res, 2016;5:2742.
    PMID: 28163898 DOI: 10.12688/f1000research.9971.1
    Aim: The purpose of this study was to compare the changes in relative peripheral refractive error produced by two different designs of progressive soft contact lenses in myopic schoolchildren. Methods: Twenty-seven myopic schoolchildren age between 13 to 15 years were included in this study. The measurements of central and peripheral refraction were made using a Grand-Seiko WR-5100K open-field autorefractometer without correction (baseline), and two different designs of progressive contact lenses (PCLs) (Multistage from SEED & Proclear from Cooper Vision) with an addition power of +1.50 D. Refractive power was measured at center and at eccentricities between 35º temporal to 35º nasal visual field (in 5º steps). Results: Both PCLs showed a reduction in hyperopic defocus at periphery. However, this reduction was only significant for the Multistage PCL (p= 0.015), (Proclear PCL p= 0.830).  Conclusion: Multistage PCLs showed greater reduction in peripheral retinal hyperopic defocus among myopic schoolchildren in comparison to Proclear PCLs.
    Matched MeSH terms: Contact Lenses, Hydrophilic
  2. Bariah Mohd Ali, Goh, E.H.
    MyJurnal
    The objective of this study was to determine the efficiency of UV blocking monomers in contact lenses in providing eye protection from UV radiation. The spectral transmission of 8 contact lenses (7 soft contact lenses: Precision UV, Acuvue 2, Surevue, Omega, Encore UV, Durasoft 3 and Lunelle UV and 1 rigid gas permeable contact lens: Boston 7) was evaluated by using a dual beam spectrophotometer. Durasoft 3, a non UV absorbent contact lens was used as the control. The results showed that Precision UV contact lens absorbed UV light up to wavelength of 380 nm, whereas Acuvue 2 and Surevue absorbed up to 360 nm only. Omega, Encore UV and Lunelle UV lenses absorbed UV light up to 335 nm with spectral transmission of Lunelle UV being the highest among all soft contact lenses tested, which was 17%. Boston 7 could absorb UV light up to 385 nm, but the amount of UV light transmitted was higher than soft lenses, which was 30%. Durasoft 3 only blocked UV light at 200-245 nm. Precision UV lens had better UV blocker characteristics than the other contact lenses tested. UV blocking soft contact lenses could be an alternative for spectacles in protecting internal ocular structures from UV radiation.
    Matched MeSH terms: Contact Lenses, Hydrophilic
  3. Price H, Allen PM, Radhakrishnan H, Calver R, Rae S, Theagarayan B, et al.
    Optom Vis Sci, 2013 Nov;90(11):1274-83.
    PMID: 24100478 DOI: 10.1097/OPX.0000000000000067
    To identify variables associated with myopia progression and to identify any interaction between accommodative function, myopia progression, age, and treatment effect in the Cambridge Anti-Myopia Study.
    Matched MeSH terms: Contact Lenses, Hydrophilic*
  4. Goh PP, Shamala R, Chandamalar S, Tai XY, National Eye Database Study Group
    Med J Malaysia, 2010 Jun;65 Suppl A:120-3.
    PMID: 21488471
    To create a national registry of contact-lens related corneal ulcers (CLRCU) patients in Malaysia with the aim of detecting outbreaks, identifying pattern of causative organisms, determining patient demography, risk factors, wearing patterns and monitoring outcome of treatment. The CLRCU registry is an ongoing patient registry established in 2007 as a surveillance tool used by Malaysian Ministry of Health ophthalmology departments. Notification of patients clinically suspected of CLRCU was performed online through the National Eye Database (NED). Data collected included patient demography, contact lens type, causative organism and treatment outcome. During 2007-2008, a total of 202 patients were notified to the CLRCU registry with a mean age of 26.7 years (71.8% female). All registered patients wore soft contact lens and monthly disposable lenses were the most popular (83.5%). The majority of patients had bacterial CLRCU and the most common causative organism was Pseudomonas (79.7% of bacterial cases). No epidemics were identified during the period of data examination. Use of contact lenses, which is increasing during modern times, may lead to CLRCU as a severe complication. The CLRCU registry is an effective tool which uses a web-based notification system that allows quick and up to date reports of CLRCU cases. This provides the ability to monitor outbreaks of disease and identify important causative and associated factors of the disease which may be used to reduce future incidence.
    Matched MeSH terms: Contact Lenses, Hydrophilic/adverse effects*
  5. Nura Syahiera Ibrahim, Firdaus Yusuf @ Alias, Norsham Ahmad
    MyJurnal
    Introduction: Unequal retinal image size (RIS) or aniseikonia is usually related with anisometropia. Higher dif- ferences of RIS may manifest symptoms such as dizziness, headache or disorientation. In worst case might cause suppression that leads to amblyopia. Current study aims to evaluate the consistency of aniseikonia measurement in Smart Optometry smartphone application among myopic, hyperopic, and astigmatic simulated anisometropia and real anisometropia groups. Methods: Fifteen real anisometropes (refractive error; -0.50 until -6.00 diopters; D) and fifteen emmetropes (refractive error: -0.25 until +0.50D) were recruited. Real anisometropes wore their habitual spectacle correction while each emmetropes were fitted using soft contact lenses of +4.00DS, -4.00DS and -4.00DC with base curve 8.6 and total diameter 14.2mm in random order to mimic myopic-, hyperopic- and astigmat- ic-anisometropia before testing. Participants with any ocular disease and binocular vision problem were excluded. The consistency of aniseikonia measurement was determined in two visits, separated by at least 24-hour interval. Three repetitive measurements were taken in each visit. Results: Independent t-test and paired t-test showed that real and simulated anisometropia gave insignificant aniseikonia percentage, p>0.05. ICC findings revealed moder- ate-to-good agreement for all simulated and real groups. Bland Altman analysis between two visits exhibited good agreement among all simulated group; myopic (mean difference 0.2047; 95%CI:-1.1386-1.549), hyperopic (mean difference 0.2200; 95%CI:-0.9286-1.3686) and astigmatic (mean difference 0.2533; 95%CI:-0.7114-1.2180). Real anisometropes demonstrated good agreement with bias value of 0.2247(95%CI:-0.9162-1.3656) using Bland Altman plot. Conclusion: Smart Optometry application provides consistent measurement of aniseikonia regardless any types of anisometropia.

    Matched MeSH terms: Contact Lenses, Hydrophilic
  6. Ang, Wen-Jeat, Embong Zunaina, Raja Omar Raja Norliza, Abdul Jalil Fadzillah
    MyJurnal
    We describe the first clinical case of contact lens related corneal ulcer caused by Elizabethkingia meningosepticaregistered in Southeast Asia. A 20-year-old female student who wasa regular soft contact lens wearer, presented with pain, photophobia and blurring of vision of the right eye for 3 days. On slit lamp examination, there was a small paracentral anterior stromal infiltrate with an overlying epithelial defect. Microbiological cultures from corneal scrapings, contact lens and its casing were positive for E.meningoseptica. Due to high likelihood of contact lens contamination causing keratitis, topical fortified gentamicin0.9% and ceftazidime 5% were administered empirically. Topical vancomycin 5% was later added tailoring to the culture and sensitivity of the organism. After 8 weeks of treatment, the keratitis subsided and corneal epithelial defect completely healed with residual corneal opacity. Even though uncommon, contact lens related E.meningosepticakeratitis can occur in healthy immunocompetent individuals with no ocular comorbidities.
    Matched MeSH terms: Contact Lenses, Hydrophilic
  7. Wolffsohn JS, Calossi A, Cho P, Gifford K, Jones L, Jones D, et al.
    Cont Lens Anterior Eye, 2020 02;43(1):9-17.
    PMID: 31761738 DOI: 10.1016/j.clae.2019.11.002
    PURPOSE: A survey in 2015 identified a high level of eye care practitioner concern about myopia with a reported moderately high level of activity, but the vast majority still prescribed single vision interventions to young myopes. This research aimed to update these findings 4 years later.

    METHODS: A self-administrated, internet-based questionnaire was distributed in eight languages, through professional bodies to eye care practitioners globally. The questions examined: awareness of increasing myopia prevalence, perceived efficacy of available strategies and adoption levels of such strategies, and reasons for not adopting specific strategies.

    RESULTS: Of the 1336 respondents, concern was highest (9.0 ± 1.6; p contact lenses (p contact lenses as the primary mode of correction for myopic patients (63.6 ± 21.8 %). The main justifications for their reluctance to prescribe alternatives to single vision refractive corrections were increased cost (20.6 %) and inadequate information (17.6 %).

    CONCLUSIONS: While practitioner concern about myopia and the reported level of activity have increased over the last 4 years, the vast majority of eye care clinicians still prescribe single vision interventions to young myopes. With recent global consensus evidence-based guidelines having been published, it is hoped that this will inform the practice of myopia management in future.

    Matched MeSH terms: Contact Lenses, Hydrophilic
  8. Ali NA, Reddy SC
    Eye Contact Lens, 2007 Nov;33(6 Pt 1):338-40.
    PMID: 17993833
    PURPOSE: To report an unusual case of bilateral simultaneous hypopyon corneal ulcer in a contact lens wearer caused by polymicrobial infection with rare organisms.
    METHODS: A case report of a 21-year-old soft contact lens wearer, who visited the emergency department with a 3-day history of pain, redness, decreased vision, photophobia, and tearing in both eyes. Examination showed a central corneal ulcer with hypopyon in both eyes. The cultures from corneal scrapings of both eyes, the contact lenses, and the contact lens solution showed heavy growth of Pseudomonas aeruginosa, Alkaligenes species, and Flavobacterium meningosepticum.
    RESULTS: The corneal ulcers healed completely with aggressive antibiotic treatment for 4 weeks. The best-corrected visual acuity after 6 months of follow-up was 20/400 in the right eye and 20/60 in the left eye.
    CONCLUSIONS: The possibility of infectious keratitis should be kept in mind for an acute red eye in contact lens wearers, and appropriate initial management is essential for a successful outcome. It is believed that this is the first report of Flavobacterium meningosepticum as a causative organism in contact lens-related keratitis.
    Matched MeSH terms: Contact Lenses, Hydrophilic/adverse effects*
  9. Bastion ML, Mohamad MH
    Eye Contact Lens, 2006 Sep;32(5):223-7.
    PMID: 16974154
    PURPOSE: To investigate factors associated with the presence of microdot deposits or white dots (WDs) on confocal microscopy in regular soft contact lens (SCL) users.
    METHODS: This cross-sectional observational study investigated changes in the cornea in regular SCL users by using an in vivo slit-scanning microscope (ConfoScan 3). Images were analyzed by noting the presence of highly reflective WDs. Factors associated with WDs were analyzed by using an unpaired t test with Welch correction.
    RESULTS: There were 56 SCL wearers. Of these, a group of 10 had WDs (GWD) in various parts of the cornea. They had worn SCLs for 7 to 20 years and had a mean total duration of SCL wear of 13.6 +/- 4.4 years. Their mean age was 35.8 +/- 10.4 years. They were compared with a group of SCL wearers with no evidence of WDs (GNWD). The mean age of GNWD was 29.1 +/- 7.2 years, with a mean duration of SCL use of 8.17 +/- 5.1 years. The two groups were compared in terms of age, total duration of SCL wear (years), duration in hours per week, SCL water content (%), mean cell density in the endothelium and stroma, endothelial cell coefficient of cell size variation, and percentage of hexagonal cells. Only the duration of SCL wear was significantly associated with the presence of WDs (p=0.0042). WDs were most commonly found in the posterior stroma (n = 9). Two patients had WDs in the epithelium, with one of these having WDs in the endothelium. All patients except one with a hazy left eye scan had WDs bilaterally and symmetrically.
    CONCLUSIONS: Confocal microscopy allows visualization of WDs in the corneas of Asian regular SCL users. Patients with WDs have a longer history of SCL wear. WDs may represent an early stage of corneal disease or degeneration associated with alterations in cell behavior.
    Matched MeSH terms: Contact Lenses, Hydrophilic/adverse effects*
  10. Mohd-Ali B, Chen LY
    Cont Lens Anterior Eye, 2021 02;44(1):72-75.
    PMID: 32624364 DOI: 10.1016/j.clae.2020.06.007
    PURPOSE: To analyse and compare the alterations in corneal endothelium morphology induced by different materials and durations of wearing soft contact lenses (CL) among young adults living in Kuala Lumpur.

    METHODS: Healthy soft CL wearers were invited to participate in this study. Visual acuity (VA) was measured using the Snellen chart, and subjective refraction was performed using cross-cylinder technique. Standard ocular assessments were conducted using a slit lamp biomicroscope and morphology of corneal endothelial cells (endothelial cell density, ECD, coefficient variation, COV, hexagonality, HEX and central corneal thickness, CCT) were evaluated using a non-contact specular microscope. Statistical analysis was conducted using ANOVA and data from the right eye only is included.

    RESULTS: A total of 72 subjects (32 SiHy and 40 HCL wearers) and 24 non-CL wearers (control) participated in this study. The gender distribution for study subjects was 13 males and 59 females, with a mean age 22.15 ± 1.84 years old. The mean refraction was -1.86 ± 1.25DS. The duration of wearing CL ranged from 1 to 9 years. Subjects were later divided into 2 groups following duration of CL wear: Group 1 (<5 years) and Group 2 (≥5 years) for analysis purposes. Statistical analysis showed significant alterations in ECD, COV and HEX of CL wearers (p Contact lens material and duration of CL wear (in years) are factors that affect the alterations. Optometrists are recommended to regularly evaluate the morphology of corneal endothelial cells in CL wearers and provide necessary intervention when required.

    Matched MeSH terms: Contact Lenses, Hydrophilic/adverse effects*
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links