Displaying all 6 publications

Abstract:
Sort:
  1. Cheong SM, Totsu S, Nakanishi H, Uchiyama A, Kusuda S
    J Neonatal Perinatal Med, 2016;9(1):99-105.
    PMID: 27002262 DOI: 10.3233/NPM-16915054
    OBJECTIVE: In order to evaluate safety and usefulness of peripherally inserted double lumen central catheter (PIDLCC) in very low birth weight (VLBW) infants, outcomes of VLBW infants who had PIDLCC was studied.

    SUBJECTIVE: Thirty-nine VLBW infants who were admitted to our NICU in 2013 were retrospectively analyzed.

    RESULTS: Mean birth weight and gestational age was 1042.7 gram and 28.5 weeks, respectively. Total duration of indwelling PIDLCC was 1121 days (mean 28.5+18.2 days) with 85 PIDLCCs used. Dressing at the insertion site was done twice weekly with 10% povidone iodine. Four (10.3% with mean of 48 days) infants had catheter-related blood stream infection (CRBSI), with a 3.57 infection per 1000 catheter-day. The mean for days of PIDLCC in 35 infants without CRBSI was 26.5 days. Organisms isolated were Staphylococcus epidermidis, Staphylococcus aureus and Staphylococcus capitis ureolytic. Our study showed significant difference in the duration of indwelling catheter (p = 0.023) and intraventricular hemorrhage (p = 0.043) between the CRBSI group and non-CRBSI group. Five (12.8%) infants had abnormal thyroid function test, in which two infants required thyroxine supplementation upon discharge. However, duration of PIDLCC and abnormal thyroid function test was not statistically significant (p = 0.218). One (2.5%) infant died (death was not related to CRBSI). There was no serious adverse effects secondary to PIDLCC.

    CONCLUSION: It is concluded that the use and maintenance of PIDLCC is safe for VLBW infants, but close monitoring should be observed to detect early signs of infection.

    Matched MeSH terms: Catheter-Related Infections/epidemiology*
  2. Rosenthal VD, Bat-Erdene I, Gupta D, Rajhans P, Myatra SN, Muralidharan S, et al.
    J Vasc Access, 2021 Jan;22(1):34-41.
    PMID: 32406328 DOI: 10.1177/1129729820917259
    BACKGROUND: Short-term peripheral venous catheter-associated bloodstream infection rates have not been systematically studied in Asian countries, and data on peripheral venous catheter-associated bloodstream infections incidence by number of short-term peripheral venous catheter days are not available.

    METHODS: Prospective, surveillance study on peripheral venous catheter-associated bloodstream infections conducted from 1 September 2013 to 31 May 2019 in 262 intensive care units, members of the International Nosocomial Infection Control Consortium, from 78 hospitals in 32 cities of 8 countries in the South-East Asia Region: China, India, Malaysia, Mongolia, Nepal, Philippines, Thailand, and Vietnam. For this research, we applied definition and criteria of the CDC NHSN, methodology of the INICC, and software named INICC Surveillance Online System.

    RESULTS: We followed 83,295 intensive care unit patients for 369,371 bed-days and 376,492 peripheral venous catheter-days. We identified 999 peripheral venous catheter-associated bloodstream infections, amounting to a rate of 2.65/1000 peripheral venous catheter-days. Mortality in patients with peripheral venous catheter but without peripheral venous catheter-associated bloodstream infections was 4.53% and 12.21% in patients with peripheral venous catheter-associated bloodstream infections. The mean length of stay in patients with peripheral venous catheter but without peripheral venous catheter-associated bloodstream infections was 4.40 days and 7.11 days in patients with peripheral venous catheter and peripheral venous catheter-associated bloodstream infections. The microorganism profile showed 67.1% were Gram-negative bacteria: Escherichia coli (22.9%), Klebsiella spp (10.7%), Pseudomonas aeruginosa (5.3%), Enterobacter spp. (4.5%), and others (23.7%). The predominant Gram-positive bacteria were Staphylococcus aureus (11.4%).

    CONCLUSIONS: Infection prevention programs must be implemented to reduce the incidence of peripheral venous catheter-associated bloodstream infections.

    Matched MeSH terms: Catheter-Related Infections/epidemiology*
  3. Rosenthal VD, Bat-Erdene I, Gupta D, Belkebir S, Rajhans P, Zand F, et al.
    Am J Infect Control, 2020 04;48(4):423-432.
    PMID: 31676155 DOI: 10.1016/j.ajic.2019.08.023
    BACKGROUND: We report the results of International Nosocomial Infection Control Consortium (INICC) surveillance study from January 2012 to December 2017 in 523 intensive care units (ICUs) in 45 countries from Latin America, Europe, Eastern Mediterranean, Southeast Asia, and Western Pacific.

    METHODS: During the 6-year study period, prospective data from 532,483 ICU patients hospitalized in 242 hospitals, for an aggregate of 2,197,304 patient days, were collected through the INICC Surveillance Online System (ISOS). The Centers for Disease Control and Prevention-National Healthcare Safety Network (CDC-NHSN) definitions for device-associated health care-associated infection (DA-HAI) were applied.

    RESULTS: Although device use in INICC ICUs was similar to that reported from CDC-NHSN ICUs, DA-HAI rates were higher in the INICC ICUs: in the medical-surgical ICUs, the pooled central line-associated bloodstream infection rate was higher (5.05 vs 0.8 per 1,000 central line-days); the ventilator-associated pneumonia rate was also higher (14.1 vs 0.9 per 1,000 ventilator-days,), as well as the rate of catheter-associated urinary tract infection (5.1 vs 1.7 per 1,000 catheter-days). From blood cultures samples, frequencies of resistance, such as of Pseudomonas aeruginosa to piperacillin-tazobactam (33.0% vs 18.3%), were also higher.

    CONCLUSIONS: Despite a significant trend toward the reduction in INICC ICUs, DA-HAI rates are still much higher compared with CDC-NHSN's ICUs representing the developed world. It is INICC's main goal to provide basic and cost-effective resources, through the INICC Surveillance Online System to tackle the burden of DA-HAIs effectively.

    Matched MeSH terms: Catheter-Related Infections/epidemiology*
  4. Shanmuganathan M, Goh BL, Lim CTS
    Am J Med Sci, 2018 11;356(5):476-480.
    PMID: 30384954 DOI: 10.1016/j.amjms.2018.08.004
    BACKGROUND: Noncuffed catheters (NCC) are often used for incident hemodialysis (HD) patients without a functional vascular access. This, unfortunately results in frequent catheter-related complications such as infection, malfunction, vessel stenosis, and obstruction, leading to loss of permanent central venous access with superior vena cava obstruction. It is important to preserve central vein patency by reducing the number of internal jugular catheter insertions for incident HD patients with a functional vascular access. We sought to achieve this by introducing in-patient intermittent peritoneal dialysis (IPD) as bridging therapy while awaiting establishment of long-term vascular access for HD patients.

    METHODS: Incident HD patients without permanent vascular access encountered from January to December 2014 were included in this study. Patients were divided into 2 groups: Group 1 were encountered within 6 months prior to introduction of in-patient IPD bridging therapy in substitution of noncuffed catheter (NCC) insertion while awaiting maturation of permanent vascular access. Group 2 were encountered within 6 months after the introduction of this policy. The number of NCC and peritoneal dialysiscatheter insertion, along with catheter-related infections were evaluated during this period.

    RESULTS: Approximately 450 patients were distributed in each group. We achieved 45% reduction in internal jugular catheter insertion from 322 to 180 catheters after policy change. This led to a significant drop in catheter-related blood stream infection (53%, P <0.001). On the other hand, 30% more peritoneal dialysiscatheter were inserted to accommodate our IPD bridging therapy.

    CONCLUSIONS: The introduction of IPD as bridging therapy while awaiting maturation of permanent vascular access significantly reduced the utilization of NCC in incident HD patients and catherter-related blodstream infection. With this, it is our hope that it will contribute to the preservation of central vein patency.

    Matched MeSH terms: Catheter-Related Infections/epidemiology*
  5. Rickard CM, Marsh NM, Larsen EN, McGrail MR, Graves N, Runnegar N, et al.
    Lancet, 2021 04 17;397(10283):1447-1458.
    PMID: 33865494 DOI: 10.1016/S0140-6736(21)00351-2
    BACKGROUND: The optimal duration of infusion set use to prevent life-threatening catheter-related bloodstream infection (CRBSI) is unclear. We aimed to compare the effectiveness and costs of 7-day (intervention) versus 4-day (control) infusion set replacement to prevent CRBSI in patients with central venous access devices (tunnelled cuffed, non-tunnelled, peripherally inserted, and totally implanted) and peripheral arterial catheters.

    METHODS: We did a randomised, controlled, assessor-masked trial at ten Australian hospitals. Our hypothesis was CRBSI equivalence for central venous access devices and non-inferiority for peripheral arterial catheters (both 2% margin). Adults and children with expected greater than 24 h central venous access device-peripheral arterial catheter use were randomly assigned (1:1; stratified by hospital, catheter type, and intensive care unit or ward) by a centralised, web-based service (concealed before allocation) to infusion set replacement every 7 days, or 4 days. This included crystalloids, non-lipid parenteral nutrition, and medication infusions. Patients and clinicians were not masked, but the primary outcome (CRBSI) was adjudicated by masked infectious diseases physicians. The analysis was modified intention to treat (mITT). This study is registered with the Australian New Zealand Clinical Trials Registry ACTRN12610000505000 and is complete.

    FINDINGS: Between May 30, 2011, and Dec, 9, 2016, from 6007 patients assessed, we assigned 2944 patients to 7-day (n=1463) or 4-day (n=1481) infusion set replacement, with 2941 in the mITT analysis. For central venous access devices, 20 (1·78%) of 1124 patients (7-day group) and 16 (1·46%) of 1097 patients (4-day group) had CRBSI (absolute risk difference [ARD] 0·32%, 95% CI -0·73 to 1·37). For peripheral arterial catheters, one (0·28%) of 357 patients in the 7-day group and none of 363 patients in the 4-day group had CRBSI (ARD 0·28%, -0·27% to 0·83%). There were no treatment-related adverse events.

    INTERPRETATION: Infusion set use can be safely extended to 7 days with resultant cost and workload reductions.

    FUNDING: Australian National Health and Medical Research Council.

    Matched MeSH terms: Catheter-Related Infections/epidemiology
  6. Mushahar L, Mei LW, Yusuf WS, Sivathasan S, Kamaruddin N, Idzham NJ
    Perit Dial Int, 2015 09 15;36(2):135-9.
    PMID: 26374836 DOI: 10.3747/pdi.2014.00195

    OBJECTIVE: Peritoneal dialysis (PD)-related infection is a common cause of catheter loss and the main reason for PD drop-out. Exit-site infection (ESI) is a pathway to developing tunnel infection and peritonitis, hence rigorous exit-site care has always been emphasized in PD therapy. The aim of this study was to evaluate the effect of exit-site dressing vs non-dressing on the rate of PD-related infection. ♦

    METHODS: A prospective randomized controlled study was conducted in prevalent PD patients at the Hospital Tuanku Jaafar Seremban, Negeri Sembilan, Malaysia, from April 2011 until April 2013. All patients were required to perform daily washing of the exit site with antibacterial soap during a shower. In the dressing group (n = 54), patients were required to clean their exit site using povidone-iodine after drying, followed by topical mupirocin antibiotic application to the exit site. The exit site was then covered with a sterile gauze dressing and the catheter immobilized with tape. In the non-dressing group (n = 54), patients were not required to do any further dressing after drying. They were only required to apply mupirocin cream to the exit site and then left the exit site uncovered. The catheter was immobilized with tape. The primary outcome was ESI. The secondary outcomes were evidence of tunnel infection or peritonitis. ♦

    RESULTS: A total of 97 patients completed the study. There were a total of 12 ESI episodes: 4 episodes in 4 patients in the dressing group vs 8 episodes in 4 patients in the non-dressing group. This corresponds to 1 episode per 241.3 patient-months vs 1 episode per 111.1 patient-months in the dressing and non-dressing groups respectively. Median time to first ESI episode was shorter in the non-dressing than in the dressing group, but not significant (p = 0.25). The incidence of gram-positive ESI in both groups was similar. There were no gram-negative ESI in the non-dressing group compared with 2 in the dressing group. The peritonitis rate was 1 per 37.1 patient-month in the dressing group and 1 per 44.4 patient-months in the non-dressing group. Median time to first peritonitis episode was significantly shorter in the dressing group compared to non-dressing (p = 0.03). There was no impact of dressing disruptions in the occurrence of major PD catheter-related infection. ♦

    CONCLUSION: Use of a non-dressing technique with only prophylactic topical mupirocin cream application is effective in preventing PD-related infection. The non-dressing technique is more cost-effective and convenient for PD patients, with fewer disposables.

    Matched MeSH terms: Catheter-Related Infections/epidemiology*