Displaying all 7 publications

Abstract:
Sort:
  1. Saw A, Chua YP, Hossain G, Sengupta S
    J Orthop Surg (Hong Kong), 2012 Aug;20(2):181-4.
    PMID: 22933675
    To assess the monthly rates of infection of individual pin sites in 7 patients during distraction osteogenesis.
    Matched MeSH terms: Bone Nails/adverse effects*
  2. Razak M, Basir T, Hyzan Y, Johari Z
    Med J Malaysia, 1998 Sep;53 Suppl A:1-5.
    PMID: 10968176
    This is a cross-sectional study on the use of halovest appliance in the Orthopaedic and Traumatology Department, Kuala Lumpur Hospital from June 1993 to September 1996. Fifty-three patients with cervical spine injuries were treated by halovest stabilization. Majority of cases was caused by motor-vehicle accident; others were fall from height at construction sites, fall at home, hit by falling object and assault. The injuries were Jefferson fracture of C1, odontoid fractures, hangman fractures, open spinous process fracture and fracture body of C2, and fracture, and fracture-dislocation of the lower cervical spines. Majority of patients had hospital stay less than 30 days. The use of the halovest ranges from 4 to 16 weeks and the healing rate was 96%. Two patients of lower cervical spine injury had redislocation and one of them was operated. There was one case of non-union of type II odontoid fracture and treated by posterior fusion. Other complications encountered during halovest treatment were minor. They were pin-site infection, pin-loosening, clamp loosening and neck pain or neck stiffness. This method of treatment enables patient to ambulate early and reduces hospital stay. We found that halovest is easy to apply, safe and tolerable to most of the patients.
    Matched MeSH terms: Bone Nails/adverse effects
  3. Selvakumar K, Saw KY, Fathima M
    Med J Malaysia, 2001 Dec;56 Suppl D:24-8.
    PMID: 14569762
    Intramedullary nailing is an accepted procedures for femoral fractures gives uniformly good results. Various methods of intramedullary fixation have been practiced in the past. Recently intramedullary fixation without reaming has come into vogue. Preservation of the endosteal blood supply, less blood loss and quicker union have been the alleged benefits of not reaming the medullary canal. This study is a prospective randomised study conducted to compare intramedullary nail fixation of closed femoral fractures with and without a reaming procedure to assess the validity of the above assumptions. One hundred and two consecutive cases of skeletally mature patients with closed fracture of femoral shaft were randomised into two groups, i.e. Reamed (52) and Unreamed (50). The average follow-up was 36 weeks (range 28-86 weeks). Average time taken for various stages of the operation and total operating time were longer in the reamed group (109.9 min vs 78.6 min) and the blood loss was also increased (320 mls vs. 190 mls). Bridging and callus formation were seen to occur earlier in the reamed group compared to the unreamed enabling the patients in the reamed group to return to normal functions earlier. Limb length discrepancy and rotational alignment measured clinically and with CT scan did not however show any significant difference between the two methods. Nails used in this study group were notably of a smaller diameter and of shorter length when compared to those used in the western population highlighting the difference in the femur in the Asian population. Complications were notably more in the unreamed group where these were screw breakage (3/50) delayed unions (9/50) and non-unions (4/50). In the reamed group however there were only delayed union (2/50) and all fractures eventually united without any implant failure. We conclude that closed, reamed, antegrade insertion of an intramedullary nail is the treatment of choice in femoral shaft fractures, especially those involving the distal 1/3. The unreamed procedure should be reserved for certain exceptions, such as in polytrauma, where a shorter operative time and less blood loss is desired.
    Matched MeSH terms: Bone Nails/adverse effects*
  4. Cheong ML, Chan CY, Saw LB, Kwan MK
    Eur Spine J, 2009 Jul;18 Suppl 2:269-71.
    PMID: 19390875 DOI: 10.1007/s00586-009-1004-y
    We present a case report of a patient with pneumocranium secondary to halo vest pin penetration and a review of literature. The objectives of this study are to report a rare complication of halo vest pin insertion and to discuss methods of prevention of this complication. Halo vest orthosis is a commonly used and well-tolerated upper cervical spinal stabilizing device. Reports of complications related to pin penetration is rare and from our review, there has been no reports of pneumocranium occurring from insertion of pins following standard anatomical landmarks. A 57-year-old male sustained a type 1 traumatic spondylolisthesis of C2/C3 following a motor vehicle accident. During application of the halo vest, penetration of the left anterior pin through the abnormally enlarged frontal sinus occurred. The patient developed headache, vomiting and CSF rhinorrhoea over his left nostril. He was treated with intravenous Ceftriaxone for 1 week. This resulted in resolution of his symptoms as well as the pneumocranium. In conclusion, complications of halo vest pin penetration are rare and need immediate recognition. Despite the use of anatomical landmarks, pin penetration is still possible due to aberrant anatomy. All patients should have a skull X-ray with a radio-opaque marker done prior to placement of the halo vest pins and halo vest pins have to be inserted by experienced personnel to enable early detection of pin penetration.
    Matched MeSH terms: Bone Nails/adverse effects*
  5. Rasit AH, Mohammad AW, Pan KL
    Med J Malaysia, 2006 Feb;61 Suppl A:79-82.
    PMID: 17042236
    Trend towards changing the face of management for pediatric femoral fractures tends to advocate operative treatment. This study was undertaken to review our current practice in the wake of recent progress in the management of pediatric femoral fractures. Fifty patients with femoral diaphyseal fracture treated in Sarawak General Hospital were reviewed retrospectively after an average follow-up of 2.6 years. There were 36 boys and 14 girls, with a mean age of 6.2 years (range five months to 14 years). Children under six years of age constituted the majority of the patients. Half of the fractures were caused by road traffic accident. Nine patients had associated injuries. The most common site of fracture was at the middle third (N=31). The treatment regimens were delayed hip spica (DHS) in 16, immediate hip spica (IHS) in 24, plate osteosynthesis (PO) in five, titanium elastic nailing (TEN) in five, and external fixation (EF) in one. The minimum hospital stay was two days, and the maximum 33 days (mean, 9.7 days). Malunion was the commonest complication. Conservative treatment is the preferred option for children under six years of age. It is cost-effective with minimal complication. The other treatment options are reserved for specific indication in older children. Diaphyseal fractures of the femur in children can be adequately managed non-operatively.
    Matched MeSH terms: Bone Nails/adverse effects
  6. Lee CK, Chua YP, Saw A
    Clin Orthop Relat Res, 2012 Feb;470(2):610-5.
    PMID: 21842299 DOI: 10.1007/s11999-011-1990-z
    Pin site infection is a common problem in external fixation. Plain gauze wetted with normal saline is commonly used for a pin site dressing owing to the simplicity and low cost. Evidence to support adding an antimicrobial agent in the dressing material is lacking.
    Matched MeSH terms: Bone Nails/adverse effects*
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links