Displaying publications 1 - 20 of 136 in total

Abstract:
Sort:
  1. Teoh YX, Othmani A, Lai KW, Goh SL, Usman J
    Comput Methods Programs Biomed, 2023 Dec;242:107807.
    PMID: 37778138 DOI: 10.1016/j.cmpb.2023.107807
    BACKGROUND AND OBJECTIVE: Knee osteoarthritis (OA) is a debilitating musculoskeletal disorder that causes functional disability. Automatic knee OA diagnosis has great potential of enabling timely and early intervention, that can potentially reverse the degenerative process of knee OA. Yet, it is a tedious task, concerning the heterogeneity of the disorder. Most of the proposed techniques demonstrated single OA diagnostic task widely based on Kellgren Lawrence (KL) standard, a composite score of only a few imaging features (i.e. osteophytes, joint space narrowing and subchondral bone changes). However, only one key disease pattern was tackled. The KL standard fails to represent disease pattern of individual OA features, particularly osteophytes, joint-space narrowing, and pain intensity that play a fundamental role in OA manifestation. In this study, we aim to develop a multitask model using convolutional neural network (CNN) feature extractors and machine learning classifiers to detect nine important OA features: KL grade, knee osteophytes (both knee, medial fibular: OSFM, medial tibial: OSTM, lateral fibular: OSFL, and lateral tibial: OSTL), joint-space narrowing (medial: JSM, and lateral: JSL), and patient-reported pain intensity from plain radiography.

    METHODS: We proposed a new feature extraction method by replacing fully-connected layer with global average pooling (GAP) layer. A comparative analysis was conducted to compare the efficacy of 16 different convolutional neural network (CNN) feature extractors and three machine learning classifiers.

    RESULTS: Experimental results revealed the potential of CNN feature extractors in conducting multitask diagnosis. Optimal model consisted of VGG16-GAP feature extractor and KNN classifier. This model not only outperformed the other tested models, it also outperformed the state-of-art methods with higher balanced accuracy, higher Cohen's kappa, higher F1, and lower mean squared error (MSE) in seven OA features prediction.

    CONCLUSIONS: The proposed model demonstrates pain prediction on plain radiographs, as well as eight OA-related bony features. Future work should focus on exploring additional potential radiological manifestations of OA and their relation to therapeutic interventions.

    Matched MeSH terms: Tibia
  2. Katchy AU, Agu AU, Ikele IT, Esom E, Nto NJ
    Niger J Clin Pract, 2019 Oct;22(10):1423-1429.
    PMID: 31607734 DOI: 10.4103/njcp.njcp_93_19
    Background: The morphological parameters of the proximal tibia play a major role in total knee replacement and there are ethnic and gender variations to these parameters.

    Aim: To evaluate parameters of the proximal tibia geometry amongst the Igbos of South Eastern Nigeria and discuss the clinical implications in total knee replacement.

    Methods: The proximal tibia parameters of 558 adult tibiae bones, 300 right-sided and 258 left-sided, collected from the osteological unit of the department of anatomy University of Nigeria Enugu campus were measured using a Venier calipers.

    Results: The values of the determined parameters are as follows: anterior posterior dimension (APD): 5.50 cm, medial lateral dimension (MLD):7.53 ± 5.56 cm, proximal length (PL): 7.32 ± 0.67 cm, proximal width (PW) CM: 4.10 ± 0.30 cm, medial tibia posterior slope (MTPS):11.36 ± 4.15° and lateral tibia posterior slope (LTPS):5.65 ± 2.72°. The correlation test between these parameters of the proximal tibia shows a strong significant correlation between LPTS and MPTS (r =0.814, P < .001). The comparison of the means of the MPTS of both sides using independent samples t test shows a mean difference that is not significant (p =0.628). A comparison of the values with other populations shows significant mean difference for MLD with that of Chinese and American populations (p < .05). The mean difference between the APD of this study and the Chinese is significant (p =0.007). A comparison of MPTS and LPTS for Malaysian, Chinese, and white Americans shows a significance difference for all the three populations (p tibia surface coverage in total knee replacement amongst the Igbo population.

    Matched MeSH terms: Tibia/anatomy & histology*; Tibia/surgery
  3. Ismail TB, Mahmoud MM, Ahmed OE, Bola AH, Bahaa ZH
    Med J Malaysia, 2023 Mar;78(2):163-170.
    PMID: 36988525
    INTRODUCTION: Benign bone tumours occur most commonly during the first through third decades of life and often weaken the bones, which may predispose them to pathological fractures. Great diversity and debate in the management of primary bone tumours are based on the tumour extent. There has been an increasing trend toward the intra-operative filling of these lesions. We hypothesised that in some benign bone tumours, filling the resulting cavity after curettage was unnecessary. This study was carried out to determine whether it is necessary to fill the resultant cavity after the curettage of benign bone tumours and to represent various fillers.

    MATERIALS AND METHODS: A retrospective study of patients diagnosed as benign bone tumours according to the Enneking classification who underwent simple or extended curettage at Menoufia university-Orthopedic Oncology Division (with or without grafting or filling) during the surgical treatment (Jan 2015 to Feb 2020). A review of the medical records was done. Lesions' size (length, width and depth) was measured on plain radiographs using the image j program. When applicable, degrees of filling of the resultant cavity were classified into four categories, according to Modified Neer's classification. Functional evaluation using the musculoskeletal tumour society (MSTS) score was reviewed.

    RESULTS: Overall, 88 patients diagnosed with a primary bone tumour and who received the surgical intervention were included in the study. The mean age of the patients was 22.61+13.497 (3-58) years. There were 48 males and 40 females (54 right and 34 left). The mean follow-up period was 28.09+16.13 months. The most common location was the distal femur in 15 patients, the proximal femur in 10 patients and the proximal tibia in 12 patients. The most common diagnosis was giant cell tumour in 20 patients, followed by UBC in 19 patients, ABC in 15 patients and enchondroma in 13 patients. Twenty-three patients had simple curettage, while 65 patients had extended curettage. Mean MSTS was 28.78±1.68. Fifty-five lesions were classified according to modified Neer's classification.Thirtty-two patients were classified as type 1 with complete healing,22 patient was classified as type 2 with partial healing, and only one was classified as a recurrent lesion. Seven patients (7.9%) developed local recurrences.

    CONCLUSION: Filling the resulting cavity after the removal of the pathological tissues is usually necessary but not always required. This is determined by the type of lesion and the size of the resulting cavity following curettage. Individualised surgery is required; additional fixation should be considered.

    Matched MeSH terms: Tibia/pathology; Tibia/surgery
  4. Lloyd S, Rashid AH, Das S, Ibrahim S
    Anat Sci Int, 2014 Mar;89(2):122-5.
    PMID: 24158808 DOI: 10.1007/s12565-013-0211-0
    Tibial hemimelia is a rare anomaly of unknown etiology. This condition can occur sporadically or may have a familial inheritance. It is characterized by deficiency of the tibia with a relatively intact fibula. The anomaly may be unilateral or bilateral. We report a case of a 2-year-old girl who presented with right lower limb deformity since birth. She was diagnosed with proximal femur focal deficiency with absence of the ipsilateral tibia. She presented with a shorter right lower limb and a deformed foot. She was treated with a through-knee amputation. Anatomical dissection of the amputated limb was carried out to verify the anomalies. The dissection showed that the distal phalanx of the great toe was trifid. The anatomical and clinical significance of this interesting case is discussed.
    Matched MeSH terms: Tibia/abnormalities*
  5. CHIA M
    Med J Malaya, 1957 Mar;11(3):247-9.
    PMID: 13477003
    Matched MeSH terms: Tibia*
  6. Lee OS, Ahn S, Ahn JH, Teo SH, Lee YS
    Arch Orthop Trauma Surg, 2018 Feb;138(2):227-236.
    PMID: 29143167 DOI: 10.1007/s00402-017-2826-4
    INTRODUCTION: The purpose of this systematic review and meta-analysis was to evaluate the efficacy of concurrent cartilage procedures during high tibial osteotomy (HTO) for medial compartment osteoarthritis (OA) by comparing the outcomes of studies that directly compared the use of HTO plus concurrent cartilage procedures versus HTO alone.

    MATERIALS AND METHODS: Results that are possible to be compared in more than two articles were presented as forest plots. A 95% confidence interval was calculated for each effect size, and we calculated the I 2 statistic, which presents the percentage of total variation attributable to the heterogeneity among studies. The random effects model was used to calculate the effect size.

    RESULTS: Seven articles were included to the final analysis. Case groups were composed of HTO without concurrent procedures and control groups were composed of HTO with concurrent procedures such as marrow stimulation procedure, mesenchymal stem cell transplantation, and injection. The case group showed a higher hospital for special surgery score and mean difference was 4.10 [I 2 80.8%, 95% confidence interval (CI) - 9.02 to 4.82]. Mean difference of the mechanical femorotibial angle in five studies was 0.08° (I 2 0%, 95% CI - 0.26 to 0.43). However, improved arthroscopic, histologic, and MRI results were reported in the control group.

    CONCLUSION: Our analysis support that concurrent procedures during HTO for medial compartment OA have little beneficial effect regarding clinical and radiological outcomes. However, they might have some beneficial effects in terms of arthroscopic, histologic, and MRI findings even though the quality of healed cartilage is not good as that of original cartilage. Therefore, until now, concurrent procedures for medial compartment OA have been considered optional. Nevertheless, no conclusions can be drawn for younger patients with focal cartilage defects and concomitant varus deformity. This question needs to be addressed separately.

    Matched MeSH terms: Tibia/surgery*
  7. Anuar-Ramdhan IM, Azahari IM, Med Orth M
    Malays Orthop J, 2014 Nov;8(3):33-6.
    PMID: 26401234 MyJurnal DOI: 10.5704/MOJ.1411.008
    The diaphyseal tibia fracture is best treated with intramedullary nail but in some cases where the nail is not applicable, plate fixation will be the next option of fixation. The extensile anterior approach is normally used for conventional compression plate fixation in tibia shaft fractures. The extensive surgical dissection may devitalizes the bony fragments and interfere with the fracture union as well as soft tissue healing. Minimally Invasive Plate Osteosynthesis (MIPO) provides good preservation of blood supply and fracture hematoma at the fracture site thus promotes biological bone healing. The use of indirect reduction techniques and small skin incisions to introduce the plate is technically demanding and requires fluoroscopy exposures throughout the surgery, being some of its drawbacks. We recommend MIPO for conventional compression plate fixation in tibial shaft fractures in view of the reduced surgical trauma to the surrounding soft tissue and good functional outcome.
    Matched MeSH terms: Tibia; Tibial Fractures
  8. Ramlee MH, Gan HS, Daud SA, Abdul Wahab A, Abdul Kadir MR
    J Foot Ankle Surg, 2020 7 1;59(4):664-672.
    PMID: 32600559 DOI: 10.1053/j.jfas.2019.09.006
    Osteoporosis and osteoarthritis are common pathological problems of the human bone tissue. There are some cases of pilon fractures associated with these 2 pathological conditions. In terms of treatment, for a normal and healthy bone with pilon fracture, the use of the Delta external fixator is a favorable option because it can allow early mobilization for patients and provide stability for the healing process. However, the stability of the external fixator differs when there is low bone stiffness, which has not been previously investigated. Therefore, this study was conducted to determine the stability of the external fixator to treat pilon fracture associated with osteoporosis and osteoarthritis, particularly to differentiate the stress distribution and micromovement of fracture fragment. Three-dimensional finite element models of the ankle and foot bones were reconstructed based on the computed tomography datasets. The bones consisted of 5 metatarsal, 3 cuneiform, and 1 each of cuboid, navicular, calcaneus, talus, fibula, and tibia bones. They were assigned with linear isotropic behavior. The ankle joint consisted of ligament and cartilage, and they were assigned with the use of linear links and the Mooney-Rivlin model, respectively. During simulation of the gait cycle, 70 N and 350 N were applied axially to the tibia bone to represent the swing and stance phases, respectively. The metatarsal and calcaneus bones were fixed to prevent any movement of the rigid body. The study found that the greatest von Mises stress value was observed at the pin-bone interface for the osteoporosis (108 MPa) model, followed by the osteoarthritis (87 MPa) and normal (44 MPa) models, during the stance phase. For micromovement, the osteoporosis model had the largest value at 0.26 mm, followed by the osteoarthritis (0.09 mm) and normal (0.03 mm) models. In conclusion, the greatest magnitudes of stress and micromovement were observed for the osteoporosis bone and extra care should be taken to treat pilon fracture associated with this pathological condition.
    Matched MeSH terms: Tibia
  9. Chee, E.K., Ewe, T.W.
    Malays Orthop J, 2010;4(2):0-0.
    MyJurnal
    In total knee arthroplasty, mechanical alignment guides have improved the accuracy of implant alignment, but errors are not uncommon. In the present study, an image-free computer-assisted navigation system was used to analyse the accuracy of an extramedullary (tibial) alignment system, which is based on predetermined, fixed anatomical landmarks. Comparisons were made between two surgeons, with different levels of competency in order to determine if experience affected the accuracy of extramedullary tibial jig placement, in either the coronal and sagittal planes or both planes. The results showed that the accuracy of the extramedullary tibial alignment system, in the coronal plane (in up to 80-87% of cases) was much better than for posterior slope, and sagittal plane. Surgeon experience was not a significant factor.
    Matched MeSH terms: Tibia
  10. Nazri Mohd Yusof
    MyJurnal
    Gastrocnemius flap is the workhorse for wound coverage in the proximal
    tibia. It can be perform by general orthopaedic surgeon because it is done without the
    need of microscopic instrumentation. Its coverage can be extended to cover the knee
    and midshaft of tibia when skin overlying it is included in the flap. (Copied from article).
    Matched MeSH terms: Tibia
  11. Kamarul Izham Kamarudin, Nur Dini Mohd Yusof, Suresh Chopra
    MyJurnal
    Open reduction and internal fixation using
    conventional lateral distal femur locking plate is a
    standard operative method for distal femur fracture.
    This case series describes medial plating of distal
    femur fracture using proximal tibia locking plate that
    is anatomically fit to the medial aspect of distal femur,
    by the minimally invasive plate osteosynthesis (MIPO)
    technique which gives a stable construct with good
    outcome.
    Matched MeSH terms: Tibia
  12. Thong FY, Mansor A, Ramalingam S, Yusof N
    Cell Tissue Bank, 2020 Mar;21(1):107-117.
    PMID: 31894432 DOI: 10.1007/s10561-019-09804-4
    Bone allografts donated by other individuals offer a viable alternative to autograft. Risks of disease transmission are overcome by sterilizing the bone; unfortunately sterilization methods generally affect bone functional properties including osteogenic potential and biomechanical integrity. This study aimed to determine any enhancement effect when gamma sterilised allografts was impregnated with autologous bone marrow in improving the rate and quality of integration in metaphyseal-tibial defects of rabbits. Almost all subjects showed 50% of the defect being covered by new bones by the third week and smaller residual defect size in the treated group at the fifth week. Hounsfield units at the defect site showed increasing healing in all samples, with the treated group having an apparent advantage although insignificant (p > 0.05). In the histopathological score evaluating healing over cortical and cancellous bone at the fracture site showed only slight variations between the groups (p > 0.05). Therefore no enhanced healing by the autologous bone marrow was observed when added to the bone allografts in treating the unicortical defects.
    Matched MeSH terms: Tibia/injuries*; Tibia/pathology; Tibia/surgery; Tibial Fractures/pathology; Tibial Fractures/physiopathology; Tibial Fractures/therapy*
  13. Ramlee MH, Kadir MR, Murali MR, Kamarul T
    Med Eng Phys, 2014 Oct;36(10):1322-30.
    PMID: 25127377 DOI: 10.1016/j.medengphy.2014.05.015
    Pilon fractures are commonly caused by high energy trauma and can result in long-term immobilization of patients. The use of an external fixator i.e. the (1) Delta, (2) Mitkovic or (3) Unilateral frame for treating type III pilon fractures is generally recommended by many experts owing to the stability provided by these constructs. This allows this type of fracture to heal quickly whilst permitting early mobilization. However, the stability of one fixator over the other has not been previously demonstrated. This study was conducted to determine the biomechanical stability of these external fixators in type III pilon fractures using finite element modelling. Three-dimensional models of the tibia, fibula, talus, calcaneus, navicular, cuboid, three cuneiforms and five metatarsal bones were reconstructed from previously obtained CT datasets. Bones were assigned with isotropic material properties, while the cartilage was assigned as hyperelastic springs with Mooney-Rivlin properties. Axial loads of 350 N and 70 N were applied at the tibia to simulate the stance and the swing phase of a gait cycle. To prevent rigid body motion, the calcaneus and metatarsals were fixed distally in all degrees of freedom. The results indicate that the model with the Delta frame produced the lowest relative micromovement (0.03 mm) compared to the Mitkovic (0.05 mm) and Unilateral (0.42 mm) fixators during the stance phase. The highest stress concentrations were found at the pin of the Unilateral external fixator (509.2 MPa) compared to the Mitkovic (286.0 MPa) and the Delta (266.7 MPa) frames. In conclusion, the Delta external fixator was found to be the most stable external fixator for treating type III pilon fractures.
    Matched MeSH terms: Tibia/physiology; Tibia/radiography; Tibia/surgery; Tibial Fractures/physiopathology; Tibial Fractures/radiography; Tibial Fractures/surgery*
  14. Pirouzi G, Abu Osman NA, Oshkour AA, Ali S, Gholizadeh H, Abas WA
    Sensors (Basel), 2014;14(9):16754-65.
    PMID: 25207872 DOI: 10.3390/s140916754
    The suspension system and socket fitting of artificial limbs have major roles and vital effects on the comfort, mobility, and satisfaction of amputees. This paper introduces a new pneumatic suspension system that overcomes the drawbacks of current suspension systems in donning and doffing, change in volume during daily activities, and pressure distribution in the socket-stump interface. An air pneumatic suspension system (APSS) for total-contact sockets was designed and developed. Pistoning and pressure distribution in the socket-stump interface were tested for the new APSS. More than 95% of the area between each prosthetic socket and liner was measured using a Tekscan F-Scan pressure measurement which has developed matrix-based pressure sensing systems. The variance in pressure around the stump was 8.76 kPa. APSS exhibits less pressure concentration around the stump, improved pressure distribution, easy donning and doffing, adjustability to remain fitted to the socket during daily activities, and more adaptability to the changes in stump volume. The volume changes were adjusted by utility of air pressure sensor. The vertical displacement point and reliability of suspension were assessed using a photographic method. The optimum pressure in every level of loading weight was 55 kPa, and the maximum displacement was 6 mm when 90 N of weight was loaded.
    Matched MeSH terms: Tibia*
  15. Ali S, Abu Osman NA, Naqshbandi MM, Eshraghi A, Kamyab M, Gholizadeh H
    Arch Phys Med Rehabil, 2012 Nov;93(11):1919-23.
    PMID: 22579945 DOI: 10.1016/j.apmr.2012.04.024
    To investigate the effects of 3 dissimilar suspension systems on participants' satisfaction and perceived problems with their prostheses.
    Matched MeSH terms: Tibia*
  16. Pan KL, Mourougayah V, Jayamalar T
    Med J Malaysia, 2003 Dec;58(5):783-5.
    PMID: 15190672
    We present an elderly patient with a squamous cell carcinoma over the subcutaneous aspect of the leg involving the tibia. En bloc resection of the tumour together with a 10 centimetre segment of the tibia was done. The resected bone was autoclaved, replaced in its original position and stabilized with bone cement and a locked nail. This allowed early ambulation with minimal cost.
    Matched MeSH terms: Tibia/surgery*
  17. Merican AM, Iranpour F, Amis AA
    J Orthop Res, 2009 Mar;27(3):335-9.
    PMID: 18925647 DOI: 10.1002/jor.20756
    This study investigated the effect of loading the iliotibial band (ITB) on the stability of the patellofemoral joint. We measured the restraining force required to displace the patella 10 mm medially and laterally (defined as medial and lateral stability, respectively) in 14 fresh-frozen knees from 0 to 90 degrees knee flexion. The testing rig allowed the patella to rotate and translate freely during this displacement. The quadriceps was separated into five components and loaded with 175 N total tension. Testing was performed at 0 to 90 N ITB tension. With no ITB tension, the lateral restraining force ranged from 82 to 101 N across 0 to 90 degrees flexion. Increasing ITB tension caused progressive reduction of the lateral restraining force. The maximum reduction was 25% at 60 degrees flexion and 90 N ITB tension. Medial restraining force increased progressively with increasing knee flexion and increasing ITB loads; it ranged from 74 N at 0 degrees knee flexion and 0 N ITB tension to 211 N at 90 degrees knee flexion and 90 N ITB tension. The maximum effect was an increase of medial restraining force of 50% at 90 degrees flexion and 90 N ITB tension.
    Matched MeSH terms: Tibia/physiology*
  18. Zainal Abidin NA, Abdul Wahab AH, Abdul Rahim RA, Abdul Kadir MR, Ramlee MH
    Med Biol Eng Comput, 2021 Sep;59(9):1945-1960.
    PMID: 34392448 DOI: 10.1007/s11517-021-02419-6
    Complication rates of anterior cruciate ligament reconstruction (ACL-R) were reported to be around 15% although it is a common arthroscopic procedure with good outcomes. Breakage and migration of fixators are still possible even months after surgery. A fixator with optimum stability can minimise those two complications. Factors that affect the stability of a fixator are its configuration, material, and design. Thus, this paper aims to analyse the biomechanical effects of different types of fixators (cross-pin, interference screw, and cortical button) towards the stability of the knee joint after ACL-R. In this study, finite element modelling and analyses of a knee joint attached with double semitendinosus graft and fixators were carried out. Mimics and 3-Matic softwares were used in the development of the knee joint models. Meanwhile, the graft and fixators were designed by using SolidWorks software. Once the meshes of all models were finished in 3-Matic, simulation of the configurations was done using MSC Marc Mentat software. A 100-N anterior tibial load was applied onto the tibia to simulate the anterior drawer test. Based on the findings, cross-pin was found to have optimum stability in terms of stress and strain at the femoral fixation site for better treatment of ACL-R.
    Matched MeSH terms: Tibia/surgery
  19. Ajit Singh V, Nasirudin N, Bernatt M
    Asia Pac J Clin Oncol, 2013 Jun;9(2):182-9.
    PMID: 22897856 DOI: 10.1111/j.1743-7563.2012.01553.x
    Custom-made endoprosthetic reconstruction for distal tibia tumors is a viable option of treatment in carefully selected patients. It maintains satisfactory function and provides good pain relief. We report four cases of giant cell tumors of the distal tibia successfully treated by endoprosthetic reconstruction. This is a feasible option in cases of this nature and offers a better function than the other available options.
    Matched MeSH terms: Tibia/pathology; Tibia/radiography; Tibia/surgery*
  20. Takaoka H, Srisuka W, Saeung A
    J Med Entomol, 2017 Jul 01;54(4):945-948.
    PMID: 28399286 DOI: 10.1093/jme/tjx064
    Simulium (Simulium) umphangense, a new human-biting species of black fly, is described based on females captured while attacking humans in western and central Thailand. The female of this new species is similar to those of S. (S.) indicum Becher, S. (S.) nigrogilvum Summers, and S. (S.) vanellum Huang et al. in the Simulium griseifrons species-group of the subgenus Simulium Latreille in having the frons densely covered with golden-yellow short hairs, a character rarely found in the subgenus Simulium. This new species is readily distinguished from the three related species by having a darkened fore tibia, a bare subcosta (or rarely with a few hairs), and an ovipositor valve not protruded posteriorly. Additional diagnostic characters of this new species are noted. This is the seventh human-biting species of black fly in Thailand.
    Matched MeSH terms: Tibia
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links