  1. Zainab K, Adlina S
    Med J Malaysia, 2004 Aug;59(3):395-401.
    PMID: 15727387 MyJurnal
    A comparative pilot study was conducted to determine the difference in the reduction of total serum bilirubin in a group of infants who had phototherapy at home compared to an in-patient group on hospital phototherapy. Eighteen infants with unconjugated hyperbilirubinaemia who fitted the selection criteria were put under the mobile home unit (Bluelite Portable Light) placed in the home. A control group of 18 infants with the same matching characteristics had intense phototherapy in the hospital using a unit with top and bottom light sources. The infants were matched for race, starting total serum bilirubin level, birth weight (up to 250 grams) and age of baby at initiation of phototherapy (up to one-day difference). It was observed that the mean daily decrease in serum bilirubin concentration was significantly more in the home group as compared to the hospital group (t=2.95, df=17, P<0.05). The mean duration of treatment was significantly less for the home group as compared to the hospital group (t=2.84, df=17, P<0.05). None of the infants who had home phototherapy were re-hospitalized. Phototherapy related complications were mild and comparable in both groups. The result suggests that home phototherapy is safe and effective in bringing down the concentration of serum bilirubin for term babies with uncomplicated hyperbilirubinaemia.
    Matched MeSH terms: Bilirubin/blood
  2. Yadav H
    Med J Malaysia, 1985 Jun;40(2):143-4.
    PMID: 3834287
    Matched MeSH terms: Bilirubin/blood*
  3. Tan KL
    Acta Paediatr Scand, 1982 Jul;71(4):593-6.
    PMID: 7136674
    Matched MeSH terms: Bilirubin/blood*
  4. Sinniah D, Nagalingam I, Chua CP, Khoo KP, Dugdale AE
    Clin Pediatr (Phila), 1974 Sep;13(9):765-6.
    PMID: 4429633 DOI: 10.1177/000992287401300913
    Matched MeSH terms: Bilirubin/blood*
  5. Boo NY, Ishak S
    J Paediatr Child Health, 2007 Apr;43(4):297-302.
    PMID: 17444833
    To determine the sensitivity and specificity of different levels of bilirubin measured by the transcutaneous bilirubinometer Bilicheck on forehead and sternum for predicting severe hyperbilirubinaemia of total serum bilirubin (TSB)>or=300 micromol/L in Malay, Chinese and Indian infants.
    Matched MeSH terms: Bilirubin/blood
  6. Djokomuljanto S, Quah BS, Surini Y, Noraida R, Ismail NZ, Hansen TW, et al.
    Arch. Dis. Child. Fetal Neonatal Ed., 2006 Nov;91(6):F439-42.
    PMID: 16877479
    To determine whether the addition of low-cost reflecting curtains to a standard phototherapy unit could increase effectiveness of phototherapy for neonatal jaundice.
    Matched MeSH terms: Bilirubin/blood
  7. Jalloh S, Van Rostenberghe H, Yusoff NM, Ghazali S, Nik Ismail NZ, Matsuo M, et al.
    Pediatr Int, 2005 Jun;47(3):258-61.
    PMID: 15910447
    The role of hemolysis in the pathophysiology of neonatal jaundice (NNJ) in patients with glucose 6-phosphate dehydrogenase (G6PD) deficiency has been questioned recently. The aim of the present study was to determine the contribution of hemolysis to the pathophysiology of jaundice in Malay neonates with G6PD deficiency and NNJ.
    Matched MeSH terms: Bilirubin/blood
  8. Boo NY, Lee HT
    J Paediatr Child Health, 2002 Apr;38(2):151-5.
    PMID: 12030996
    OBJECTIVE: To compare the rates of decrease in serum bilirubin levels in severely jaundiced healthy term infants given oral or intravenous fluid supplementation during phototherapy.

    METHODS: A randomized controlled study was carried out in the neonatal intensive care unit (NICU) of Hospital Universiti Kebangsaan Malaysia over a 12-month period. Fifty-four healthy term infants with severe hyperbilirubinemia were randomized to receive either solely enteral feeds (n = 27) or both enteral and intravenous (n = 27) fluid during phototherapy.

    RESULTS: There were no significant differences in the mean birthweight, mean gestational age, ethnic distribution, gender distribution, modes of delivery and types of feeding between the two groups. Similarly, there was no significant difference in the mean indirect serum bilirubin (iSB) level at the time of admission to the NICU between the enteral (359 +/- 69 micromol/L [mean +/- SD]) and intravenous group (372 +/- 59 micromol/L; P = 0.4). The mean rates of decrease in iSB during the first 4 h of phototherapy were also not significantly different between the enteral group (10.4 +/- 4.9 micromol/L per h) and intravenous group (11.2 +/- 7.4 micromol/L per h; P = 0.6). There was no significant difference in the proportion of infants requiring exchange transfusion (P = 0.3) nor in the median duration of hospitalization (P = 0.7) between the two groups. No infant developed vomiting or abdominal distension during the study period.

    CONCLUSION: Severely jaundiced healthy term infants had similar rates of decrease in iSB levels during the first 4 h of intensive phototherapy, irrespective of whether they received oral or intravenous fluid supplementation. However, using the oral route avoided the need for intravenous cannulae and their attendant complications.

    Matched MeSH terms: Bilirubin/blood
  9. Boo NY, Abu Bakar A
    Med J Malaysia, 1984 Mar;39(1):35-7.
    PMID: 6513837
    The transcutaneous (Tc) bilirubinometer was evaluated in 105 jaundiced neonates, comprising 38 Malays, 37 Chinese and 30 Indians, who had not been treated with phototherapy or exchange transfusion. Tc bilirubin index and serum bilirubin concentration correlated at statistically significant levels in all the three racial groups. Unlike the Chinese and Malay babies, the action levels, using Tc bilirubin index, in the Indian babies are not reliable due to the wide variation of skin pigmentation. Neonatal jaundice is conventionally monitored by estimation of serum bilirubin level. This involves blood sampling. The transcutaneous (Tc) bilirubinometer, however, is non-invasive, small and portable. In this study, the use of the Tc bilirubinometer in the management of neonatal jaundice' in the three racial groups was evaluated.
    Matched MeSH terms: Bilirubin/blood*
  10. Tan KL
    J Singapore Paediatr Soc, 1977 Dec;19(4):238-40.
    PMID: 616476
    Matched MeSH terms: Bilirubin/blood*
  11. Sinniah D, Tay LK, Dugdale AE
    Arch Dis Child, 1971 Oct;46(249):712-5.
    PMID: 5118063
    Matched MeSH terms: Bilirubin/blood
  12. Noor HZ, Noor HZ, Makhmudi A, Gunadi
    Med J Malaysia, 2020 05;75(Suppl 1):1-4.
    PMID: 32483103
    BACKGROUND: Many prognostic factors have been reported for the outcomes of biliary atresia (BA) patients after Kasai procedure, however, it still shows a conflicting result. Our study was to determine the impact of total bilirubin postoperative day-7 and pre-operative ratio (TB7/TB0), gammaglutamyl transferase post-operative day-7 and pre-operative ratio (GGT7/GGT0), and alanine transaminase post-operative day-7 and pre-operative ratio (ALT7/ALT0) on the survival of BA patients following Kasai surgery.

    METHODS: We reviewed the medical records of BA patients who underwent Kasai procedure at the Dr. Sardjito Hospital, Indonesia from August 2012 to December 2018. The cut-off values of TB7/TB0, GGT7/GGT0, and ALT7/ALT0 for prediction of patients' survival were determined by receiver operating characteristics (ROC) curves. Log-rank tests were utilised to test the association between cut-off values and overall survival.

    RESULTS: In all 46 BA patients (23 males and 23 females) after Kasai procedure were included, consisting of one type 1, 17 type 2A, seven type 2B, and 21 type 3. The cut-off values of TB7/TB0, ALT7/ALT0 and GGT7/GGT0 for overall survival was 0.455 (sensitivity 87.5%, specificity 22.7%, area under curve (AUC) 0.59; 95% Confidence Interval (95%CI): 0.42, 0.75), 0.481 (sensitivity 87.5%, specificity 18.2%, AUC 0.49; 95%CI: 0.31, 0.65), and and 0.31 (sensitivity 79.2%, specificity 9.1%, AUC 0.34; 95%CI: 0.18, 0.50), respectively. However, these cut-off values were not significantly associated with overall survival, with p-values of 0.18, 0.49, and 0.56, respectively.

    CONCLUSION: The TB7/TB0, ALT7/ALT0, and GGT7/GGT0 might not predict the overall survival of BA patients after Kasai procedure. Further multicentre studies with a larger sample size is needed to clarify our findings.

    Matched MeSH terms: Bilirubin/blood*
  13. Van Rostenberghe H, Ho JJ, Lim CH, Abd Hamid IJ
    Cochrane Database Syst Rev, 2020 07 01;7:CD012011.
    PMID: 32609375 DOI: 10.1002/14651858.CD012011.pub2
    BACKGROUND: Phototherapy is a well-established effective therapy for treating babies with significant neonatal jaundice. Studies have shown that increasing light intensity will increase its efficiency. A potentially inexpensive and easy way of increasing the intensity of light on the body of the infant may be to hang reflective materials from the sides of phototherapy units.

    OBJECTIVES: To assess the effects of reflective materials in combination with phototherapy compared with phototherapy alone for unconjugated hyperbilirubinaemia in neonates.

    SEARCH METHODS: We used the standard search strategy of Cochrane Neonatal to search the Cochrane Central Register of Controlled Trials (CENTRAL; 2019, Issue 11), in the Cochrane Library; Ovid MEDLINE(R) and Epub Ahead of Print, In-Process & Other Non-Indexed Citations, Daily and Versions(R); and the Cumulative Index of Nursing and Allied Health Literature (CINAHL), on 1 November 2019. We also searched clinical trials databases and the reference lists of retrieved articles for randomised controlled trials and quasi-randomised trials.

    SELECTION CRITERIA: We included randomised and quasi-randomised controlled trials if the participants, who were term or preterm infants, received phototherapy with curtains made of reflective materials of any type in the treatment arm, and if those in the comparison arm received similar phototherapy without curtains or other intensified phototherapy, such as a double bank of lights.

    DATA COLLECTION AND ANALYSIS: We used standard methodological procedures expected by Cochrane. We used the GRADE approach to assess the certainty of evidence.

    MAIN RESULTS: Of 15 studies identified, we included 12 (1288 babies) in the review - 11 comparing phototherapy with reflective materials and phototherapy alone, and one comparing a single phototherapy light bank with reflective materials with double phototherapy. All reflective materials consisted of curtains on three or four sides of the cot and were made of white plastic (five studies), white linen (two studies), or aluminium (three studies); materials were not specified in two studies. Only 11 studies (10 comparing reflective materials versus none and one comparing reflective curtains and a single bank of lights with a double (above and below) phototherapy unit) provided sufficient data to be included in the meta-analysis. Two excluded studies used the reflective materials in a way that did not meet our inclusion criteria, and we excluded one study because it compared four different phototherapy interventions not including reflective materials. The risk of bias of included studies was generally low, but all studies had high risk of performance bias due to lack of blinding of the intervention. Three studies (281 participants) reported a decline in serum bilirubin (SB) (μmol/L) at four to eight hours (mean difference (MD) -14.61, 95% confidence interval (CI) -19.80 to -9.42; I² = 57%; moderate-certainty evidence). Nine studies (893 participants) reported a decline in SB over 24 hours and showed a faster decline in SB in the intervention group, but heterogeneity (I² = 97%) was too substantial to permit a meaningful estimate of the actual effect size (very low-certainty evidence). Subgroup analysis by type of reflective material used did not explain the heterogeneity. Exchange transfusion was reported by two studies; both reported none in either group. Four studies (466 participants) reported the mean duration of phototherapy, and in each of these studies, it was reduced in the intervention group but there was substantial heterogeneity (I² = 88%), precluding meaningful meta-analysis of data. The only two studies that reported the mean duration of hospital stay in hours showed a meaningful reduction (MD -41.08, 95% CI -45.92 to -36.25; I² = 0; moderate-certainty evidence). No studies reported costs of the intervention, parental or medical staff satisfaction, breastfeeding outcomes, or neurodevelopmental follow-up. The only study that compared use of curtains with double phototherapy reported similar results for both groups. Studies that monitored adverse events did not report increased adverse events related to the use of curtains, including acute life-threatening events, but other rarer side effects could not be excluded.

    AUTHORS' CONCLUSIONS: Moderate-certainty evidence shows that the use of reflective curtains during phototherapy may result in greater decline in SB. Very low-certainty evidence suggests that the duration of phototherapy is reduced, and moderate-certainty evidence shows that the duration of hospital stay is also reduced. Available evidence does not show any increase in adverse events, but further studies are needed.

    Matched MeSH terms: Bilirubin/blood
  14. Shwe S, Boo NY, Ong HK, Chee SC, Maslina M, Ling MMM, et al.
    Malays J Pathol, 2020 Aug;42(2):253-257.
    PMID: 32860378
    INTRODUCTION: Haemoglobin Constant Spring (Hb CoSp) and Haemoglobin Adana (Hb Adana), are two non-deletion type of α-thalassemia reported in Malaysia. Owing to their structural instability, they cause hemolysis and hyperbilirubinemia. This observational study was part of a large study investigating multiple factors associated with severe neonatal jaundice. In this part we aimed to determine the prevalence of Hb CoSp and Hb Adana and their association with clinically significant neonatal hyperbilirubinemia (SigNH, total serum bilirubin (TSB>290µmol/L)) among jaundiced Malaysian term neonates.

    MATERIALS AND METHODS: The inclusion criteria were normal term-gestation neonates admitted consecutively for phototherapy. PCR-restriction fragment length polymorphism method was applied on DNA extracted from dry blood spot specimens of each neonate to detect for Hb CoSp and Hb Adana gene. Positive samples were verified by gene sequencing.

    RESULTS: Of the 1121 neonates recruited (719 SigNH and 402 no-SigNH), heterozygous Hb CoSp gene was detected in only two (0.27%) neonates. Both were SigNH neonates (0.3% or 2/719). No neonate had Hb Adana variant.

    CONCLUSION: Hb CoSp was not common but could be a risk factor associated with SigNH. No Hb Adana was detected.

    Matched MeSH terms: Bilirubin/blood
  15. Lee KH, Hui KP, Tan WC, Lim TK
    Singapore Med J, 1993 Oct;34(5):385-7.
    PMID: 8153680
    Noninvasive oximetry provides continuous monitoring of arterial oxygen saturation and hence, early detection of hypoxia. This has proved to be a useful adjunct to patients' safety, and is considered indispensable in certain settings. However, errors may be present in the pulse oximeter estimation (SpO2) of arterial oxygen saturation (SaO2), which may be due to various parameters. We have studied a multi-ethnic population where the skin pigmentation is different, and also under different conditions comparing SpO2 with SaO2. Our results showed that SpO2 estimation of SaO2 amongst the three racial groups (Chinese, Malays, and Indians) varied significantly (ANOVA, p < 0.05). The over-estimation was more pronounced by hypoxic conditions and jaundice. Haemoglobin and systolic blood pressure did not affect the difference between SpO2 and SaO2.
    Matched MeSH terms: Bilirubin/blood
  16. Tarmalinggam Y, Prakash ES
    Adv Physiol Educ, 2007 Dec;31(4):370-1.
    PMID: 18057413
    Matched MeSH terms: Bilirubin/blood
  17. Joishy SK, Hassan K, Lopes M, Lie-Injo LE
    Trans R Soc Trop Med Hyg, 1988;82(4):515-9.
    PMID: 3076706
    Clinical studies were carried out on mild Indian sickle cell anaemia in Malaysia, and genetic and fertility studies were carried out on 101 families with and without sickle-cell haemoglobin (Hb S). The Indian sickle cell anaemia patients reached adulthood, and pregnancies and deliveries were uneventful without blood transfusion. There was no foetal wastage and the number of children produced was not significantly different from that in families without Hb S. 28 Indian patients hospitalized with Plasmodium falciparum malaria infection were also examined for their beta S genotype. P. falciparum malaria infection occurred much more frequently in individuals without Hb S than in Hb S carriers.
    Matched MeSH terms: Bilirubin/blood
  18. Choong MF, Mak JW
    Trop. Med. Parasitol., 1991 Mar;42(1):71-2.
    PMID: 1675809
    The Presbytis cristata--Brugia malayi model, now established as a reliable non-human primate model for the experimental screening of potential filaricides, was monitored at monthly intervals for changes in the liver and renal function tests and also for alkaline phosphatase levels during infection. Animals infected with 200-400 infective larvae became patient at 50-90 days post-infection and geometric mean microfilarial counts were above 1000 per ml from the fourth month onwards. There were no significant changes in the biochemical parameters monitored throughout the period of observation. This is an important observation as any changes seen in these parameters during experimental drug studies can be attributed to drug reaction or toxicity and this will be invaluable in decision making as to drug safety.
    Matched MeSH terms: Bilirubin/blood
  19. Chua BS, Song LH, Chang CT, Lim XJ, Nachiappan J
    J Paediatr Child Health, 2021 01;57(1):12-14.
    PMID: 33078471 DOI: 10.1111/jpc.15226
    The coronavirus disease 2019 (COVID-19) cases was on an increasing trend, including in Malaysia. The Malaysian Ministry of Health had implemented a range of measures, such as the use of masks and social distancing, to reduce the risk of transmission. Traditionally, newborns are evaluated for neonatal jaundice using visual assessment, a capillary heel prick and serum bilirubin (SB) sampling in primary health-care clinics. This approach requires the physical presence of both parents and their newborns in the primary health-care clinics, causing crowding and increasing the risk of COVID-19 infections. To alleviate crowding, we implemented the transcutaneous bilirubin drive-through (DT) service, which is an established, non-invasive, painless and rapid method to determine the bilirubin levels. Throughout the screening, both parents and baby will be confined to their car. A total of 1842 babies were screened in our DT setting from April to July 2020. Of the total babies, 298 (16.1%) required venesection for SB measurement and 85 required admission for phototherapy. None with severe jaundice were missed since the implementation of this service. The average test duration per neonate was less than 5 min, while conventional venous bilirubin laboratory testing required an average of 1.5 h per neonate. The cost of the SB laboratory test and consumables was approximately USD 5 per test, with an estimated cost savings of USD 7720. DT screening may be introduced in health-care settings to reduce crowding and eliminate the need of painful blood sampling in newborns.
    Matched MeSH terms: Bilirubin/blood*
  20. Boo NY, Chang YF, Leong YX, Tok ZY, Hooi LC, Chee SC, et al.
    Pediatr Res, 2019 08;86(2):216-220.
    PMID: 30696987 DOI: 10.1038/s41390-019-0304-0
    BACKGROUND: This study aimed to determine the accuracy of a point-of-care Bilistick method for measuring total serum bilirubin (TSB) and its turn-around-time (TAT) against hospital laboratory methods.

    METHODS: This prospective study was carried out on 561 term-gestation jaundiced neonates in two Malaysian hospitals. Venous blood sample was collected from each neonate for contemporary measurement of TSB by hospital laboratories and Bilistick. TAT was the time interval between specimen collection and TSB result reported by each method.

    RESULTS: The mean laboratory-measured TSB was 194.85 (±2.844) µmol/L and Bilistick TSB was 169.37 (±2.706) µmol/L. Pearson's correlation coefficient was: r = 0.901 (p 

    Matched MeSH terms: Bilirubin/blood*