Materials and methods: The sealers were evaluated before mixing, and after setting using X-ray diffraction (XRD), Energy Dispersive Analysis (EDX) and Scanning Electron Microscope (SEM) techniques. Twenty four extracted teeth were prepared and assigned to four groups according to the moisture conditions: (1) dry: using ethanol as final irrigation, (2) normal: using paper points until the last one appeared dry, (3) moist: using a Luer adapter for 5 s followed by 1 paper point, and (4) wet: the canals remained totally flooded. The roots were filled with MTA Fillapex® and Endosequence® BC and kept in phosphate buffer solution at 37 °C for 10 days. Each root was sectioned transversally and longitudinally. The sealers harvested from longitudinal sections were analysed using XRD. Whilst the transverse sections were analysed using SEM/EDX.
Results: The XRD analysis showed MTA Fillapex composed of Bismuth trioxide, calcium silicate and tricalcium aluminate. The intensity of peaks in the wet condition was reduced. Endosequence BC contained mainly calcium silicate, calcium silicate hydrate, zirconia and calcium hydroxide. The wet condition showed a small increase in hydrated calcium silicate. The EDX analysis showed changes in the elemental concentrations with different moisture conditions. The surface morphology differed with different moisture conditions.
Conclusion: Tested sealers have different constitution that not affected by the degree of moisture. However, it changed their relative quantity.
MATERIALS AND METHODS: The powder form of experimental Bio-G sealer consisted of synthesised BG 58S particle, calcium silicate, zirconia dioxide, calcium carbonate and alginic acid powder as binder. The liquid composed of 5% calcium chloride solution. Five standardised disc specimens were prepared for each sealer group according to the manufacturer's instructions. Subsequently, sealer disc-specimens were placed in an incubator at 37 °C, 95% relative humidity for 72 h to allow setting prior to testing under scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS), Fourier transformed infrared spectroscopy (FTIR) and X-ray diffraction (XRD).
RESULTS: Experimental Bio-G sealer revealed irregular micro-sized particles ranging from 0.5 μm to 105 μm aggregated in clusters comparable to those of BioRoot RCS and iRoot SP. EDS microanalysis showed that Bio-G had high content of oxygen, silicon, and calcium, with the presence of aluminium and chloride similar to BioRoot RCS. Meanwhile, the FTIR and XRD findings suggested that all sealers predominantly contained calcium silicate hydrate, calcium carbonate, and zirconium dioxide, while calcium aluminium silicate oxide was detected in Bio-G.
CONCLUSION: The present novel Bio-G sealer demonstrated desirable particle size distribution and acceptable degree of purity. Future studies are warranted to explore its properties and clinical application.