Displaying all 7 publications

Abstract:
Sort:
  1. Khandaker MU, Mat Nawi SN, Bradley DA, Lam SE, Abdul Sani SF, Sulieman A
    Appl Radiat Isot, 2021 Aug;174:109757.
    PMID: 33990033 DOI: 10.1016/j.apradiso.2021.109757
    This study analysed thermoluminescence (TL) glow curves of the polymer pencil lead graphite (PPLG) due to its potential applications in radiation dosimetry. The TL glow curves provide information on the physical parameters of the defects participating in luminescence process. The glow curves for different diameters PPLG samples were obtained with varying temperature from 50 to 300 °C, at a fixed heating rate of 10 °Cs-1. A number of methods (initial rise, peak shape and curve fitting) were used to fit the TL glow peaks of the PPLG samples obtained under photon dose of 200 Gy. From the fitted TL signals, the trap parameters such as the order of kinetics, the activation energy, the frequency factor, etc. for the individual peaks were numerically determined. The lifetimes of TL process were calculated assuming the first-order kinetics. The results are compared among the different methods adopted in this study. Implications about the possible results in glow curve deconvolution are discussed.
  2. Lam SE, Mat Nawi SN, Abdul Sani SF, Khandaker MU, Bradley DA
    Sci Rep, 2021 04 12;11(1):7939.
    PMID: 33846448 DOI: 10.1038/s41598-021-86942-4
    Preliminary study has been made of black human hair, carbon concentration of some 53%, a model in examining the potential of hair of the human head in retrospective and emergency biodosimetry applications, also offering effective atomic number near to that of water. The hair samples were exposed to [Formula: see text]Co gamma rays, delivering doses from 0 to 200 Gy. Structural alterations were observed, use being made of Raman and photoluminescence (PL) spectroscopy. Most prominent among the features observed in the first-order Raman spectra are the D and G peaks, appearing at 1370 [Formula: see text] and 1589 [Formula: see text] respectively, the intensity ratio [Formula: see text] indicating dose-dependent defects generation and annealing of structural alterations. The wavelengths of the PL absorption and emission peaks are found to be centred at [Formula: see text] nm and [Formula: see text] nm, respectively. The hair samples mean band gap energy ([Formula: see text]) post-irradiation was found to be [Formula: see text] eV, of the order of a semiconductor and approximately two times the [Formula: see text] of other carbon-rich materials reported via the same methodology.
  3. Lam SE, Noor NM, Bradley DA, Mahmud R, Pawanchek M, Abdul Rashid HA
    Biomed Phys Eng Express, 2020 Nov 05;6(6).
    PMID: 35042836 DOI: 10.1088/2057-1976/abc2a4
    This work investigates the suitability of locally fabricated 6 mol% Ge-doped optical fibres as dosimeters for small-field output ratio measurements. Two fabrications of fibre, cylindrical (CF) and flat (FF) fibres, were used to measure doses in small photon fields, from 4 to 15 mm. The findings were compared to those of commercial Ge-doped fibre (COMM), EBT3 film and an IBA CC01 ionization chamber. Irradiations were carried out using a 6 MV SRS photon beam operating at a dose rate of 1000 cGy min-1, delivering a dose of 16 Gy. To minimise the possibility of the fibres failing to be exposed to the intended dose in small fields, the fibres were accommodated in a custom-made Perspex phantom. For the 4 mm cone the CF and FF measured output ratios were found to be smaller than obtained with EBT3 film by 32% and 13% respectively. Conversely, while for the 6 to 15 mm cone fields the FF output ratios were consistently greater than those obtained using EBT3 film, the CF output ratios differed from those of EBT3 film by at most 3.2%, at 6 mm, otherwise essentially agreeing with EBT3 values at the other field sizes. For the 4 to 7.5 mm cones, all output ratios obtained from Ge-doped optical fibre measurements were greater than those of IBA CC01 ionization chamber. The measured FF and CF output ratios for the 7.5 to 15 mm cones agreed with published MC estimates to within 15% and 13%, respectively. Down to 6 mm cone field, present measurements point to the potential of CF as a small-field dosimeter, its use recommended to be complemented by the use of EBT3 film for small-field dosimetry.
  4. Lam SE, Bradley DA, Mat Nawi SN, Khandaker MU, Abdul Sani SF
    Appl Radiat Isot, 2023 Sep;199:110920.
    PMID: 37419002 DOI: 10.1016/j.apradiso.2023.110920
    The present study continues research into the utilisation of carbonaceous media for medical radiation dosimetry, focusing on the effects of surface area-to-volume ratio and carbon content on structural interaction alterations and dosimetric properties in sheet- and bead-type graphitic materials (with the respective carbon content of ∼98 wt% and ∼90 wt%). Using 60Co gamma-rays and doses from 0.5 Gy to 20 Gy, the study has been made of the response of commercially available graphite in the form of 0.1 mm, 0.2 mm, 0.3 mm and 0.5 mm thick sheets, also of activated carbon beads. Confocal Raman and photoluminescence spectroscopy have been employed, examining radiation-induced structural interaction alterations. Dose-dependent variation in the Raman intensity ratio ID/IG relates to the varying dominance of defect generation and dose-driven defect annealing. Of the various thickness graphite sheets, the 0.1 mm thick medium possesses the greatest surface area-to-volume ratio. Perhaps unsurprisingly, it also exhibits the greatest thermoluminescence (TL) yield compared to that of the other carbonaceous sheet foils used herein. Moreover, the second greatest mass-normalised TL yield has been observed to be that of the porous beads, reflected in the greater defect density (ID/IG > 2) when compared to the other media, due in part to their inherent feature of large internal surface area. Considering the challenge posed in matching skin thickness with skin dose, the near tissue equivalent graphite sheets show particular promise as a skin dosimeter, sensitive as a function of depth.
  5. Khandaker MU, Nawi SNM, Lam SE, Sani SFA, Islam MA, Islam MA, et al.
    Appl Radiat Isot, 2023 Jun;196:110771.
    PMID: 36933313 DOI: 10.1016/j.apradiso.2023.110771
    Thermoluminescence (TL) materials have a broad variety of uses in various fields, such as clinical research, individual dosimetry, and environmental dosimetry, amongst others. However, the use of individual neutron dosimetry has been developing more aggressively lately. In this regard, present study establishes a relationship between the neutron dosage and the optical property changes of graphite-rich materials caused by high doses of neutron radiation. This has been done with the intention of developing a novel, graphite-based radiation dosimeter. Herein, the TL yield of commercially graphite-rich materials (i.e. graphite sheet, 2B and HB grade pencils) irradiated by neutron radiation with doses ranging from 250 Gy to 1500 Gy has been investigated. The samples were bombarded with thermal neutrons as well as a negligible amount of gamma rays, from the nuclear reactor TRIGA-II installed at the Bangladesh Atomic Energy Commission. The shape of the glow curves was observed to be independent of the given dosage, with the predominant TL dosimetric peak maintained within the region of 163 °C-168 °C for each sample. By studying the glow curves of the irradiated samples, some of the most well theoretical models and techniques were used to compute the kinetic parameters such as the order of kinetics (b), activation energy (E) or trap depth, frequency factor (s) or escape probability, and trap lifetime (τ). All of the samples were found to have a good linear response over the whole dosage range, with 2B grade of polymer pencil lead graphite (PPLGs) demonstrating a higher level of sensitivity than both HB grade and graphite sheet (GS) samples. Additionally, the level of sensitivity shown by each of them is highest at the lowest dosage that was given, and it decreases as the dose increases. Importantly, the phenomenon of dose-dependent structural modifications and internal annealing of defects has been observed by assessing the area of deconvoluted micro-Raman spectra of graphite-rich materials in high-frequency areas. This trend is consistent with the cyclical pattern reported in the intensity ratio of defect and graphite modes in previously investigated carbon-rich media. Such recurrent occurrences suggest the idea of employing Raman microspectroscopy as a radiation damage study tool for carbonaceous materials. The excellent responses of the key TL properties of the 2B grade pencil demonstrate its usefulness as a passive radiation dosimeter. As a consequence, the findings suggest that graphite-rich materials have the potential to be useful as a low-cost passive radiation dosimeter, with applications in radiotherapy and manufacturing.
  6. Khandaker MU, Abuzaid MM, Mohamed IA, Yousef M, Jastaniah S, Alshammari QT, et al.
    Radiat Phys Chem Oxf Engl 1993, 2023 Sep;210:111023.
    PMID: 37206369 DOI: 10.1016/j.radphyschem.2023.111023
    Radiological staff, especially radiographers, work as front liners against the COVID-19 outbreak. This study aims to assess compliance with radiation protection and infection control practices during COVID-19 mobile radiography procedures. This cross-sectional study included 234 radiographers (females, 56%, n = 131; males, 44%, n = 103) who were asked to complete an online questionnaire consisting of demographic data, radiation protection and infection control practices during COVID-19 portable cases, and knowledge and awareness. After informed consent was completed, SPSS statistical software was used for the data analysis. The most common age group of participants ranged from 18 to 25 years old (30.3%, n = 71). Bachelor's degree holders were 74.4% (n = 174). Most radiographers (39.7%, n = 93) had a working experience of 1-5 years, followed by 27.8% (n = 65) with more than 16 years of experience. Most respondents (62.4%, n = 146) handled approximately 1-5 cases daily, the majority of them (56%, n = 131) stated affirmatively they had obtained special training to handle COVID-19, and when inquired if they had received any special allowances for handling COVID-19 suspected/confirmed cases most of them stated negative (73.9%, n = 173). Most participants stated that they always wear a TLD during portable cases (67.1%, n = 157) and a lead apron (51.7%, n = 121). Around 73% (n = 171) knew the latest information on COVID-19 and attended the COVID-19 awareness course. A significant association was found between the work experience of the radiographers and their responses to following the best practices (p = 0.018, α = 0.05). Radiographers who had COVID-19 training (μ = 48.78) tend to adhere more to best practices than those who have not (p = 0.04, α = 0.05). Further, respondents who handled more than 16/more COVID-19 suspected/confirmed cases followed the best practices more (μ = 50.38) than those who handled less (p = 0.04, α = 0.05). This study revealed detailed information on radiation protection and infection control practices during COVID-19 mobile radiography. It has been observed that the participants/radiographers have good knowledge and awareness of radiation protection and infection-control practices. The present results may be used to plan future requirements regarding resources and training to ensure patient safety.
  7. Muslima U, Khandaker MU, Lam SE, Mat Nawi SN, Abdul Sani SF, Ung NM, et al.
    Appl Radiat Isot, 2024 Oct;212:111457.
    PMID: 39068692 DOI: 10.1016/j.apradiso.2024.111457
    In clinical settings, standard dosimeters might miss radiation mishaps. Retrospective dosimeters could help to track personnel (such as patients and other staff who don't wear dosimeters) exceeding safe limits and assess long-term exposure trends. This study has investigated key thermoluminescence (TL) dosimetric characteristics, including the glow curve structure, dose-response, energy dependence, sensitivity and fading of various safety glasses that are used as screen protectors of smartphones subjected to photon irradiation. Among the studied glasses, the HD Anti-Peep safety glass for iPhone has been found to exhibit a linear dose-response with a regression coefficient of 99% within the dose range of 2-10 Gy. Moreover, all the safety glasses showed independence with respect to photon energy of 6 MV and 10 MV. The TL glow curves of the samples showed a broad glow peak between 125 °C and 325 °C at 10 Gy. The TL kinetic parameters of the safety glasses were also studied by analyzing the glow curves using the peak shape and initial rise method. The geometric factor (μg) is found to be within the range of 0.43-0.53, which indicates the suitability of applying Chen's general-order formula to calculate the kinetic parameters such as activation energy, frequency factor and trap lifetime. The activation energy (E) and frequency factor (s) are found in the range of 0.31-0.54 eV and 4.55 × 103 to 2.12 × 106 s-1 respectively obtained via the peak shape method. The relatively long trap lifetime and observed thermoluminescence features indicate that the HD Anti-Peep safety glass offers a better option to estimate dose retrospectively to ensure the safety of human health.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links