Displaying publications 61 - 80 of 356 in total

Abstract:
Sort:
  1. Pornsuwancharoen N, Youplao P, Amiri IS, Aziz MS, Tran QL, Ali J, et al.
    Microsc Res Tech, 2018 Aug;81(8):872-877.
    PMID: 29737596 DOI: 10.1002/jemt.23049
    A conventional Michelson interferometer is modified and used to form the various types of interferometers. The basic system consists of a conventional Michelson interferometer with silicon-graphene-gold embedded between layers on the ports. When light from the monochromatic source is input into the system via the input port (silicon waveguide), the change in optical path difference (OPD) of light traveling in the stacked layers introduces the change in the optical phase, which affects to the electron mean free path within the gold layer, induces the change in the overall electron mobility can be seen by the interferometer output visibility. Further plasmonic waves are introduced on the graphene thin film and the electron mobility occurred within the gold layer, in which the light-electron energy conversion in terms of the electron mobility can be observed, the gold layer length is 100 nm. The measurement resolution in terms of the OPD of

    50 nm is achieved. In applications, the outputs of the drop port device of the modified Michelson interferometer can be arranged by the different detectors, where the polarized light outputs, the photon outputs, the electron spin outputs can be obtained by the interference fringe visibility, mobility visibility and the spin up-down splitting output energies. The modified Michelson interferometer theory and the detection schemes are given in details.
    Matched MeSH terms: Graphite
  2. Wang P, Yang J, Li X, Liu M, Zhang X, Sun D, et al.
    Sci Rep, 2017 07 26;7(1):6615.
    PMID: 28747656 DOI: 10.1038/s41598-017-06007-3
    Uncovering energy absorption and surface effects of various penetrating velocities on laminar structures is essential for designing protective structures. In this study, both quasi-static and dynamic penetration tests were systematical conducted on the front surfaces of metal sheets coated with a graphene oxide (GO) solution and other media. The addition of a GO fluid film to the front impact surface aided in increasing the penetration strength, improving the failure extension and dissipating additional energy under a wide-range of indentation velocity, from 3.33 × 10-5 m/s to 4.42 m/s. The coated -surfaces improved the specific energy dissipation by approximately 15~40% relative to the dry-contact configuration for both single-layer and double-layer configurations, and specific energy dissipations of double-layer configurations were 20~30% higher than those of the single-layer configurations. This treatment provides a facile strategy in changing the contact state for improving the failure load and dissipate additional energy.
    Matched MeSH terms: Graphite
  3. Rafique S, Abdullah SM, Shahid MM, Ansari MO, Sulaiman K
    Sci Rep, 2017 01 13;7:39555.
    PMID: 28084304 DOI: 10.1038/srep39555
    This work demonstrates the high performance graphene oxide (GO)/PEDOT:PSS doubled decked hole transport layer (HTL) in the PCDTBT:PC71BM based bulk heterojunction organic photovoltaic device. The devices were tested on merits of their power conversion efficiency (PCE), reproducibility, stability and further compared with the devices with individual GO or PEDOT:PSS HTLs. Solar cells employing GO/PEDOT:PSS HTL yielded a PCE of 4.28% as compared to either of individual GO or PEDOT:PSS HTLs where they demonstrated PCEs of 2.77 and 3.57%, respectively. In case of single GO HTL, an inhomogeneous coating of ITO caused the poor performance whereas PEDOT:PSS is known to be hygroscopic and acidic which upon direct contact with ITO reduced the device performance. The improvement in the photovoltaic performance is mainly ascribed to the increased charge carriers mobility, short circuit current, open circuit voltage, fill factor, and decreased series resistance. The well matched work function of GO and PEDOT:PSS is likely to facilitate the charge transportation and an overall reduction in the series resistance. Moreover, GO could effectively block the electrons due to its large band-gap of ~3.6 eV, leading to an increased shunt resistance. In addition, we also observed the improvement in the reproducibility and stability.
    Matched MeSH terms: Graphite
  4. Noorhafanita Norhakim, Sahrim Ahmad, Chin HC, Nay MH
    Sains Malaysiana, 2014;43:603-609.
    In this study, graphene oxide (Go) filled epoxy nanocomposites were prepared using hot pressed method. The GO was produced using modified Hummers' method. The produced GO at different compositions (0.1, 0.3 and 0.5 wt%) were mixed with epoxy before the addition of hardener using ultra-sonication. The produced epoxy nanocomposites were characterized in terms of mechanical and thermal properties. The mechanical properties of the nanocomposites were significantly enhanced by the addition of GO. About 50% of increment in the flexural strength of the composite sample filled with 03 wt% of GO as compared to the neat epoxy sample. However, only slight improvement in the impact strength of the composite were obtained by adding 0.1 wt% of GO.
    Matched MeSH terms: Graphite
  5. Ahmad NF, Komatsu K, Iwasaki T, Watanabe K, Taniguchi T, Mizuta H, et al.
    Sci Rep, 2019 Feb 28;9(1):3031.
    PMID: 30816251 DOI: 10.1038/s41598-019-39909-5
    We report on the observation of quantum transport and interference in a graphene device that is attached with a pair of split gates to form an electrostatically-defined quantum point contact (QPC). In the low magnetic field regime, the resistance exhibited Fabry-Pérot (FP) resonances due to np'n(pn'p) cavities formed by the top gate. In the quantum Hall (QH) regime with a high magnetic field, the edge states governed the phenomena, presenting a unique condition where the edge channels of electrons and holes along a p-n junction acted as a solid-state analogue of a monochromatic light beam. We observed a crossover from the FP to QH regimes in ballistic graphene QPC under a magnetic field with varying temperatures. In particular, the collapse of the QH effect was elucidated as the magnetic field was decreased. Our high-mobility graphene device enabled observation of such quantum coherence effects up to several tens of kelvins. The presented device could serve as one of the key elements in future electronic quantum optic devices.
    Matched MeSH terms: Graphite
  6. Hosseingholi Pourasl A, Ariffin SHS, Ahmadi MT, Ismail R, Gharaei N
    Beilstein J Nanotechnol, 2019;10:644-653.
    PMID: 30931206 DOI: 10.3762/bjnano.10.64
    Nanomaterial-based sensors with high sensitivity, fast response and recovery time, large detection range, and high chemical stability are in immense demand for the detection of hazardous gas molecules. Graphene nanoribbons (GNRs) which have exceptional electrical, physical, and chemical properties can fulfil all of these requirements. The detection of gas molecules using gas sensors, particularly in medical diagnostics and safety applications, is receiving particularly high demand. GNRs exhibit remarkable changes in their electrical characteristics when exposed to different gases through molecular adsorption. In this paper, the adsorption effects of the target gas molecules (CO and NO) on the electrical properties of the armchair graphene nanoribbon (AGNR)-based sensor are analytically modelled. Thus, the energy dispersion relation of AGNR is developed considering the molecular adsorption effect using a tight binding (TB) method. The carrier velocity is calculated based on the density of states (DOS) and carrier concentration (n) to obtain I-V characteristics and to monitor its variation in the presence of the gas molecules. Furthermore, the I-V characteristics and energy band structure of the AGNR sensor are simulated using first principle calculations to investigate the gas adsorption effects on these properties. To ensure the accuracy of the proposed model, the I-V characteristics of the AGNR sensor that are simulated based both on the proposed model and first principles calculations are compared, and an acceptable agreement is achieved.
    Matched MeSH terms: Graphite
  7. Mohammad Sarwan Mohd Sanif, Amgad Ahmed Ali, Lee MW, Lee HW, Chia Sheng DB, Abdul Manaf Hashim
    Sains Malaysiana, 2017;46:1119-1924.
    The effects of the annealing temperatures and thicknesses on the shapes, sizes and arrangement of platinum (Pt) nanoparticles (NPs) on graphene and their sensing performance for hydrogen (H2) detection were investigated. It shows strong dependency of the annealing temperatures and thicknesses on the properties of NPs. It was found that the proposed technique is able to form the NPs with good size controllability and uniformity even for thick deposited layer, thus eliminating the requirement of very thin layer of below 5 nm for the direct NP synthesis by evaporation or sputtering. The transport properties of Pt NPs/graphene structure and its sensing performance on H2 at room temperature under various H2 concentration were evaluated. The results showed an acceptable sensing response, indicating an innovative approach to fabricate Pt NPs embedded graphene for gas sensing application.
    Matched MeSH terms: Graphite
  8. Muhammad Aniq Shazni, Lee MW, Lee HW
    Sains Malaysiana, 2017;46:1155-1161.
    In this work, graphene has been utilized as the sensing material for the development of a highly-sensitive flexible pressure sensor platform. It has been demonstrated that a graphene-based pressure sensor platform that is able to measure pressure change of up to 3 psi with a sensitivity of 0.042 psi-1 and a non-linearity of less than 1% has been accomplished. The developed device, which resides on a flexible platform, will be applicable for integration in continuous wearables health-care monitoring system for the measurement of blood pressure.
    Matched MeSH terms: Graphite
  9. Ong WJ, Putri LK, Mohamed AR
    Chemistry, 2020 Aug 06;26(44):9710-9748.
    PMID: 32511824 DOI: 10.1002/chem.202000708
    Photocatalytic CO2 reduction is a revolutionary approach to solve imminent energy and environmental issues by replicating the ingenuity of nature. The past decade has witnessed an impetus in the rise of two-dimensional (2D) structure materials as advanced nanomaterials to boost photocatalytic activities. In particular, the use of 2D carbon-based materials is deemed as highly favorable, not only as a green material choice, but also due to their exceptional physicochemical and electrical properties. This Review article presents a diverse range of alterations and compositions derived from 2D carbon-based nanomaterials, mainly graphene and graphitic carbon nitride (g-C3 N4 ), which have remarkably ameliorated the photocatalytic CO2 performance. Herein, the rational design of the photocatalyst systems with consideration of the aspect of dimensionality and the resultant heterostructures at the interface are systematically analyzed to elucidate an insightful perspective on this pacey subject. Finally, a conclusion and outlook on the limitations and prospects of the cutting-edge research field are highlighted.
    Matched MeSH terms: Graphite
  10. Mohamad FS, Mat Zaid MH, Abdullah J, Zawawi RM, Lim HN, Sulaiman Y, et al.
    Sensors (Basel), 2017 Dec 02;17(12).
    PMID: 29207463 DOI: 10.3390/s17122789
    This article describes chemically modified polyaniline and graphene (PANI/GP) composite nanofibers prepared by self-assembly process using oxidative polymerization of aniline monomer and graphene in the presence of a solution containing poly(methyl vinyl ether-alt-maleic acid) (PMVEA). Characterization of the composite nanofibers was carried out by Fourier transform infrared (FTIR) and Raman spectroscopy, transmission electron microscopy (TEM) and scanning electron microscopy (SEM). SEM images revealed the size of the PANI nanofibers ranged from 90 to 360 nm in diameter and was greatly influenced by the proportion of PMVEA and graphene. The composite nanofibers with an immobilized DNA probe were used for the detection of Mycobacterium tuberculosis by using an electrochemical technique. A photochemical indicator, methylene blue (MB) was used to monitor the hybridization of target DNA by using differential pulse voltammetry (DPV) method. The detection range of DNA biosensor was obtained from of 10-6-10-9 M with the detection limit of 7.853 × 10-7 M under optimum conditions. The results show that the composite nanofibers have a great potential in a range of applications for DNA sensors.
    Matched MeSH terms: Graphite
  11. Chiam SL, Lim HN, Hafiz SM, Pandikumar A, Huang NM
    Sci Rep, 2018 02 15;8(1):3093.
    PMID: 29449631 DOI: 10.1038/s41598-018-21572-x
    The energy density of conventional supercapacitors is in the range of 6-10 Wh kg-1, which has restricted them from many applications that require devices with long durations. Herein, we report a method for enhancing the energy density of a device through the parallel stacking of five copper foils coated on each side with graphene nanoplatelets. Microporous papers immersed in 2 M aqueous sodium sulphate were used as separators. With a low contact resistance of 0.05 Ω, the supercapacitor yielded an optimum specific energy density and a specific power density of 24.64 Wh kg-1 and 402 W kg-1 at 0.8 V, respectively. The working potential was increased to 2.4 V when three of the supercapacitors were connected in series, forming a tandem device. Its potential for real applications was manifested by the ability to light up a light-emitting diode for 40 s after charging for 60 s.
    Matched MeSH terms: Graphite
  12. Peik-See T, Pandikumar A, Nay-Ming H, Hong-Ngee L, Sulaiman Y
    Sensors (Basel), 2014;14(8):15227-43.
    PMID: 25195850 DOI: 10.3390/s140815227
    The fabrication of an electrochemical sensor based on an iron oxide/graphene modified glassy carbon electrode (Fe3O4/rGO/GCE) and its simultaneous detection of dopamine (DA) and ascorbic acid (AA) is described here. The Fe3O4/rGO nanocomposite was synthesized via a simple, one step in-situ wet chemical method and characterized by different techniques. The presence of Fe3O4 nanoparticles on the surface of rGO sheets was confirmed by FESEM and TEM images. The electrochemical behavior of Fe3O4/rGO/GCE towards electrocatalytic oxidation of DA was investigated by cyclic voltammetry (CV) and differential pulse voltammetry (DPV) analysis. The electrochemical studies revealed that the Fe3O4/rGO/GCE dramatically increased the current response against the DA, due to the synergistic effect emerged between Fe3O4 and rGO. This implies that Fe3O4/rGO/GCE could exhibit excellent electrocatalytic activity and remarkable electron transfer kinetics towards the oxidation of DA. Moreover, the modified sensor electrode portrayed sensitivity and selectivity for simultaneous determination of AA and DA. The observed DPVs response linearly depends on AA and DA concentration in the range of 1-9 mM and 0.5-100 µM, with correlation coefficients of 0.995 and 0.996, respectively. The detection limit of (S/N = 3) was found to be 0.42 and 0.12 µM for AA and DA, respectively.
    Matched MeSH terms: Graphite/chemistry*
  13. Sobhanzadeh E, Abu Bakar NK, Bin Abas MR, Nemati K
    J Hazard Mater, 2011 Feb 28;186(2-3):1308-13.
    PMID: 21177032 DOI: 10.1016/j.jhazmat.2010.12.001
    A simple and effective multiresidue method based on precipitation at low temperature followed by matrix solid-phase dispersion-sonication was developed and validated to determine dimethoate, malathion, carbaryl, simazine, terbuthylazine, atrazine and diuron in palm oil using liquid chromatography time-of-flight mass spectrometry (LC-TOF-MS). Liquid-liquid extraction (LLE) followed by low temperature method were optimized by studying the effect of type and volume of organic solvent (acetonitrile, acetonitrile:n-hexane (3:2 v/v) and acetone) and time of freezing to obtain high recovery yield and low co-extract fat residue in the final extract. The optimal conditions for matrix solid-phase dispersion (MSPD) were obtained using 5 g of palm oil, 2 g of primary secondary amine (PSA) as dispersing sorbent, 1 g of graphitized carbon black (GCB) as clean-up sorbent and 15 mL of acetonitrile as eluting solvent under conditions of 15 min ultrasonication at room temperature. Method validation was performed in order to study sensitivity, linearity, precision, and accuracy. Average recoveries at three concentration levels (25, 50 and 100 μg kg(-1)) were found in the range of 72.6-91.3% with relative standard deviations between 5.3% and 14.2%. Detection and quantification limits ranged from 1.5 to 5 μg kg(-1) and from 2.5 to 9 μg kg(-1), respectively.
    Matched MeSH terms: Graphite/chemistry
  14. Rifat AA, Mahdiraji GA, Chow DM, Shee YG, Ahmed R, Adikan FR
    Sensors (Basel), 2015;15(5):11499-510.
    PMID: 25996510 DOI: 10.3390/s150511499
    We propose a surface plasmon resonance (SPR) sensor based on photonic crystal fiber (PCF) with selectively filled analyte channels. Silver is used as the plasmonic material to accurately detect the analytes and is coated with a thin graphene layer to prevent oxidation. The liquid-filled cores are placed near to the metallic channel for easy excitation of free electrons to produce surface plasmon waves (SPWs). Surface plasmons along the metal surface are excited with a leaky Gaussian-like core guided mode. Numerical investigations of the fiber's properties and sensing performance are performed using the finite element method (FEM). The proposed sensor shows maximum amplitude sensitivity of 418 Refractive Index Units (RIU-1) with resolution as high as 2.4 × 10(-5) RIU. Using the wavelength interrogation method, a maximum refractive index (RI) sensitivity of 3000 nm/RIU in the sensing range of 1.46-1.49 is achieved. The proposed sensor is suitable for detecting various high RI chemicals, biochemical and organic chemical analytes. Additionally, the effects of fiber structural parameters on the properties of plasmonic excitation are investigated and optimized for sensing performance as well as reducing the sensor's footprint.
    Matched MeSH terms: Graphite/chemistry*
  15. Taniselass S, Md Arshad MK, Gopinath SCB
    Mater Sci Eng C Mater Biol Appl, 2019 Mar;96:904-914.
    PMID: 30606604 DOI: 10.1016/j.msec.2018.11.062
    Reduction of graphene oxide becomes an alternative way to produce a scalable graphene and the resulting nanomaterial namely reduced graphene oxide (rGO) has been utilized in a wide range of potential applications. In this article, the level of green reduction strategies, especially the solution-based reduction methods are overviewed based on recent progression, to get insights towards biomedical applications. The degrees of gaining tips with the solution-based green reduction methods, conditions, complexity and the resulting rGO characteristics have been elucidated comparatively. Moreover, the application of greenly produced rGO in electrochemical biosensors has been elucidated as well as their electrical performance in term of linear range and limit of detections for various healthcare biological analytes. In addition, the characterization scheme for graphene-based materials and the analyses on the reduction especially for the solution-based green reduction methods are outlined for the future endeavours.
    Matched MeSH terms: Graphite/chemistry*
  16. Karthikeyan C, Jenita Rani G, Ng FL, Periasamy V, Pappathi M, Jothi Rajan M, et al.
    Appl Biochem Biotechnol, 2020 Nov;192(3):751-769.
    PMID: 32557232 DOI: 10.1007/s12010-020-03352-4
    A facile chemical reduction approach is adopted for the synthesis of iron tungstate (FeWO4)/ceria (CeO2)-decorated reduced graphene oxide (rGO) nanocomposite. Surface morphological studies of rGO/FeWO4/CeO2 composite reveal the formation of hierarchical FeWO4 flower-like microstructures on rGO sheets, in which the CeO2 nanoparticles are decorated over the FeWO4 microstructures. The distinct anodic peaks observed for the cyclic voltammograms of studied electrodes under light/dark regimes validate the electroactive proteins present in the microalgae. With the cumulative endeavors of three-dimensional FeWO4 microstructures, phase effect between rGO sheet and FeWO4/CeO2, highly exposed surface area, and light harvesting property of CeO2 nanoparticles, the relevant rGO/FeWO4/CeO2 nanocomposite demonstrates high power and stable biophotovoltaic energy generation compared with those of previous reports. Thus, these findings construct a distinct horizon to tailor a ternary nanocomposite with high electrochemical activity for the construction of cost-efficient and environmentally benign fuel cells.
    Matched MeSH terms: Graphite/chemistry*
  17. Siew QY, Pang EL, Loh HS, Tan MTT
    Biosens Bioelectron, 2021 Mar 15;176:112895.
    PMID: 33358432 DOI: 10.1016/j.bios.2020.112895
    This study reports on the development of a novel impedimetric immunosensor design using plant-derived antigenic glycoprotein for the detection of dengue virus (DENV) IgG antibodies. The electrochemical immunosensor platform was constructed using screen-printed carbon electrode (SPCE) modified with graphene/titanium dioxide (G/TiO2) nanocomposite to improve the electrode in terms electrochemical performance and specific surface area. A plant-derived dengue envelope domain III (EDIII) protein was used as the antigenic probe protein in this immunosensing strategy. Under optimised sensing conditions, the immunosensor demonstrated high sensitivity towards DENV IgG in a wide linear working range (62.5-2000 ng/mL), with a limit of detection of 2.81 ng/mL. The immunosensor showed high specificity for discriminating DENV IgG against antibodies of other infectious disease, including the closely related Zika virus (ZIKV). The reliability of the immunosensor in serological diagnosis was verified by challenging the immunosensor against serum samples, compared to conventional enzyme-linked immunosorbent assay (ELISA). As shown by its remarkable performance throughout the study, the devised immunosensor is proposed as a reliable and practical diagnostic tool for the serological detection of dengue in realistic applications.
    Matched MeSH terms: Graphite*
  18. Rashid JIA, Kannan V, Ahmad MH, Mon AA, Taufik S, Miskon A, et al.
    Mater Sci Eng C Mater Biol Appl, 2021 Jan;120:111625.
    PMID: 33545813 DOI: 10.1016/j.msec.2020.111625
    Multidrug resistant Pseudomonas aeruginosa (P. aeruginosa) is known to be a problematic bacterium for being a major cause of opportunistic and nosocomial infections. In this study, reduced graphene oxide decorated with gold nanoparticles (AuNPs/rGO) was utilized as a new sensing material for a fast and direct electrochemical detection of pyocyanin as a biomarker of P. aeruginosa infections. Under optimal condition, the developed electrochemical pyocyanin sensor exhibited a good linear range for the determination of pyocyanin in phosphate-buffered saline (PBS), human saliva and urine at a clinically relevant concentration range of 1-100 μM, achieving a detection limit of 0.27 μM, 1.34 μM, and 2.3 μM, respectively. Our developed sensor demonstrated good selectivity towards pyocyanin in the presence of interfering molecule such as ascorbic acid, uric acid, NADH, glucose, and acetylsalicylic acid, which are commonly found in human fluids. Furthermore, the developed sensor was able to discriminate the signal with and without the presence of pyocyanin directly in P. aeruginosa culture. This proposed technique demonstrates its potential application in monitoring the presence of P. aeruginosa infection in patients.
    Matched MeSH terms: Graphite*
  19. Gul K, Sohni S, Waqar M, Ahmad F, Norulaini NAN, A K MO
    Carbohydr Polym, 2016 Nov 05;152:520-531.
    PMID: 27516300 DOI: 10.1016/j.carbpol.2016.06.045
    In the present study, we decorated chitosan (©) with Fe3O4 nanoparticles followed by cross-linking with GO to prepare Fe3O4 supported chitosan-graphene oxide composite (Fe3O4©-GO). Different properties of synthesized material were investigated by SEM, XRD, FTIR, TGA and EDX. Batch adsorption experiments were performed to remove toxic cationic and anionic dyes from industrial wastewater. To maximize removal efficiency of composite material, effect of pH (4-12), time (0-80min), Fe3O4©-GO dosage (2-10mg), initial dye concentration (2-30μgmL̄ (1)) and temperature (303, 313, and 323K) were studied. The uptake of dyes presented relatively fast adsorption kinetics with pseudo-second-order equation as the best fitting model. To understand the interaction of dye with adsorbent, Langmuir and Freundlich isotherm were applied. Thermodynamic studies were conducted to calculate the changes in free energy (ΔG(0)), enthalpy (ΔH(0)) and entropy (ΔS(0)). In view of practical application, the influence of ionic strength, recycling as well as investigations based on percent recoveries from spiked real water samples were also taken into account.
    Matched MeSH terms: Graphite/chemistry*
  20. Hiew BYZ, Lee LY, Lai KC, Gan S, Thangalazhy-Gopakumar S, Pan GT, et al.
    Environ Res, 2019 01;168:241-253.
    PMID: 30321737 DOI: 10.1016/j.envres.2018.09.030
    Pharmaceutical residues are emerging pollutants in the aquatic environment and their removal by conventional wastewater treatment methods has proven to be ineffective. This research aimed to develop a three-dimensional reduced graphene oxide aerogel (rGOA) for the removal of diclofenac in aqueous solution. The preparation of rGOA involved facile self-assembly of graphene oxide under a reductive environment of L-ascorbic acid. Characterisation of rGOA was performed by Fourier transform infrared, scanning electron microscope, transmission electron microscopy, nitrogen adsorption-desorption, Raman spectroscopy and X-ray diffraction. The developed rGOA had a measured density of 20.39 ± 5.28 mg/cm3, specific surface area of 132.19 m2/g, cumulative pore volume of 0.5388 cm3/g and point of zero charge of 6.3. A study on the simultaneous interactions of independent factors by response surface methodology suggested dosage and initial concentration as the dominant parameters influencing the adsorption of diclofenac. The highest diclofenac adsorption capacity (596.71 mg/g) was achieved at the optimum conditions of 0.25 g/L dosage, 325 mg/L initial concentration, 200 rpm shaking speed and 30 °C temperature. The adsorption equilibrium data were best fitted to the Freundlich model with correlation coefficient (R2) varying from 0.9500 to 0.9802. The adsorption kinetic data were best correlated to the pseudo-first-order model with R2 ranging from 0.8467 to 0.9621. Thermodynamic analysis showed that the process was spontaneous (∆G = - 7.19 to - 0.48 kJ/mol) and exothermic (∆H = - 12.82 to - 2.17 kJ/mol). This research concluded that rGOA is a very promising adsorbent for the remediation of water polluted by diclofenac.
    Matched MeSH terms: Graphite/chemistry*
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links