OBJECTIVE: This study aims to review the typical and relatively atypical CXR manifestations of COVID-19 pneumonia in a tertiary care hospital.
METHODS: The CXRs of 136 COVID-19 patients confirmed through real-time RT-PCR from March to May 2020 were reviewed. A literature search was performed using PubMed.
RESULTS: A total of 54 patients had abnormal CXR whilst the others were normal. Typical CXR findings included pulmonary consolidation or ground-glass opacities in a multifocal, bilateral peripheral, or lower zone distribution, whereas atypical CXR features comprised cavitation and pleural effusion.
CONCLUSION: Typical findings of COVID-19 infection in chest computed tomography studies can also be seen in CXR. The presence of atypical features associated with worse disease outcome. Recognition of these features on CXR will improve the accuracy and speed of diagnosing COVID-19 patients.
MATERIALS AND METHODS: A total of 2306 subjects were selected from the patient archives of a large dental hospital and the chronological age for each subject was recorded. This age was assigned to each specific stage of dental development for each tooth to create a RDS. To validate this RDS, a further 484 subjects were randomly chosen from the patient archives and their dental age was assessed based on the scores from the RDS. Dental age was estimated using meta-analysis command corresponding to random effects statistical model. Chronological age (CA) and Dental Age (DA) were compared using the paired t-test.
RESULTS: The overall difference between the chronological and dental age (CA-DA) was 0.05 years (2.6 weeks) for males and 0.03 years (1.6 weeks) for females. The paired t-test indicated that there was no statistically significant difference between the chronological and dental age (p > 0.05).
CONCLUSION: The validated southern Chinese reference dataset based on dental maturation accurately estimated the chronological age.
METHODS: It was a retrospective study carried out in a Level 1 arthroplasty and trauma centre. 23 patients (17 males, 6 females) with average age of 50.1 years (range, 36-68 years) with displaced acetabular fracture treated with combined incisions and plate-cable systems were included. There were 3 elementary and 18 associated fractures according to Letournel classification. Average follow-up was 23.5 months (range, 12-38.7 months). Mean operation time was 160min (range: 75-320min). Functional scores were evaluated using Harris Hip Score (HHS) whilst reduction was assessed by Matta criteria. Any displacement of reduction, osteoarthritis, heterotopic ossification, and other complications was recorded.
RESULT: 65.2% (15/23) of the patients obtained excellent HHS and 21.7% (5/23) had good HHS. There were 12 anatomical, 6 imperfect, and 5 poor reductions. No displacement was recorded in final follow-up. Complications documented: three lateral femoral cutaneous nerve injuries, two conversions to total hip arthroplasty, three Brooker stage 1 heterotrophic ossification, one pulmonary embolism and one screw irritation. No incidence of wound breakdown, infection and radiological osteoarthritis was reported.
CONCLUSIONS: Imperfect reduction of the anterior column provided clinical outcomes that are as good as total anatomical reduction. This approach minimizes soft tissue damage and reduces perioperative morbidities.
METHODS: In this study a novel system named Ceph-X is developed to computerize the manual tasks of orthodontics during cephalometric measurements. Ceph-X is developed by using image processing techniques with three main models: enhancements X-ray image model, locating landmark model, and computation model. Ceph-X was then evaluated by using X-ray images of 30 subjects (male and female) obtained from University of Malaya hospital. Three orthodontics specialists were involved in the evaluation of accuracy to avoid intra examiner error, and performance for Ceph-X, and 20 orthodontics specialists were involved in the evaluation of the usability, and user satisfaction for Ceph-X by using the SUS approach.
RESULTS: Statistical analysis for the comparison between the manual and automatic cephalometric approaches showed that Ceph-X achieved a great accuracy approximately 96.6%, with an acceptable errors variation approximately less than 0.5 mm, and 1°. Results showed that Ceph-X increased the specialist performance, and minimized the processing time to obtain cephalometric measurements of human skull. Furthermore, SUS analysis approach showed that Ceph-X has an excellent usability user's feedback.
CONCLUSIONS: The Ceph-X has proved its reliability, performance, and usability to be used by orthodontists for the analysis, diagnosis, and treatment of cephalometric.
METHODS: Patients diagnosed with a single lumbar herniated intervertebral disc (HIVD) refractory to conservative management but not willing for immediate surgery were selected for a prospective nonrandomized comparative study. An SNRB was administered as a therapeutic alternative using the AP subpedicular approach in one group (n = 25; mean age, 45 ± 5.4 years) and the oblique Scotty dog subpedicular approach in the other group (n = 22; mean age, 43.8 ± 4.7 years). Results were compared in terms of the duration of the procedure, the number of C-arm exposures, accuracy, pain relief, functional outcome and the duration of relief.
RESULTS: Our results suggest that the oblique Scotty dog subpedicular approach took a significantly longer duration (p = 0.02) and a greater number of C-arm exposures (p = 0.001). But, its accuracy of needle placement was 95.5% compared to only 72% using the AP subpedicular approach (p = 0.03). There was no significant difference in terms of clinical outcomes between these approaches.
CONCLUSIONS: The AP subpedicular approach was simple and facile, but the oblique Scotty dog subpedicular approach was more accurate. However, a brief window period of pain relief was achieved irrespective of the approaching technique used.