Elbow instability is a common feature after medial epicondyle fractures, displaced or not, even in the absence of dislocation. Undisplaced or minimally displaced fractures often have an underestimated degree of instability secondary to unrecognised capsuloligamentous and muscular injuries. The purpose of this retrospective study was to analyze and to assess objectively the results of the surgical treatment of these acute injuries.
Subclinical cerebral infarcts (SCI) have been increasingly shown to cause a significant clinical impact. However, there are limited data available on Asian patients. The objectives of this study were to determine the prevalence of SCI in ischaemic stroke patients seen in the Hospital Universiti Kebangsaan Malaysia (HUKM) and to identify its associated risk factors. We evaluated the brain computed tomography (CT) evidence of subclinical infarcts in ischaemic stroke patients. The patients were selected from those who were on regular follow up in the neurology clinic following an ischaemic stroke. The risk factors associated with subclinical infarct were documented. The brain CTs were done during acute admission and reviewed for SCI. Sixty-one patients were enrolled in this study. Twenty-two (36.1%) out of the 61 patients had SCI. The risk factors for SCI in our study were hypertension (OR 14.16 CI 2.04-97.89), diabetes mellitus (OR 12.48; CI 1.95-79.77) and leukoaraiosis (OR 28.39; CI 2.33-284.16). Subclinical cerebral infarcts were present in about one third of our ischaemic stroke patients. This finding is higher than in previous studies done on Caucasians. Hypertension, diabetes mellitus and leukoaraiosis independently predict SCI.
Study site: Pusat Perubatan Universiti Kebangsaan Malaysia (PPUKM)
We report a case of a young man who presented with proptosis as a delayed manifestation of a frontal extradural haematoma (EDH) following a minor head injury. A computed tomography (CT) of the brain done 72 hours after trauma revealed a large extradural haematoma in the right anterior cranial fossa with orbital roof fracture and subperiosteal clot extension into the orbital cavity. Right frontal craniotomy with evacuation of haematoma was done and the proptosis completely resolved after surgery. The clinical course, possible mechanism and management of the patient are discussed.
CT angiography (CTA) is a fast examination performed with a time-optimised contrast injection to enhance the cerebral arteries. Being a new imaging modality in our hospital, evaluation of the effectiveness of 64-row multislice CTA in detecting intracranial aneurysms in ruptured subarachnoid haemorrhage (SAH) cases is necessary. We conducted a descriptive prospective study by recruiting 30 consecutively operated SAH cases from May 2005 until November 2006. CTA findings were studied by radiologist and neurosurgeon and these were compared with operative findings. The sensitivity and specificity of CTA were 94.4% and 97.2% respectively. Approximately half of the patients were scanned within four hours and operated within 24 hours. In conclusion, CTA proves to be highly sensitive and specific in the diagnosis of intracranial aneurysms in our study.
KEY WORDS: Subarachnoid haemorrhage, Intracranial aneurysm, Computed tomography (CT), CT angiography (CTA), Sarawak
A 62-year old para 4 with a history of a radical hysterectomy followed by radiotherapy for endometrial carcinoma was seen shortly after insertion of a pessary for a total vault prolapse. On follow-up the pessary couldn't be retrieved. An abdominal X-ray revealed the pessary in the abdominal cavity and it had to be removed by means of a laparotomy. Fistula and defects have been reported both in longstanding pessary use and as long-term complication in radical surgery with radiotherapy. In view of potential - though rare - serious complications, adequate follow-up in pessary use is therefore mandatory. Adequate diagnostic investigations are essential in deciding on an appropriate approach for rare cases like these.
OBJECTIVE:
To assess the relationship between the HLA-DRB1 genes with disease severity as assessed by radiological erosions in Malaysian patients with rheumatoid arthritis (RA).
METHODS:
In this cross-sectional study, we studied 61 RA patients who fulfilled the ACR criteria for the diagnosis of RA. HLA-DRB1 genotyping was performed by sequence specific primer (SSP) - PCR. Radiological grading and erosive score of the hands and wrists was calculated according to the Larsen-Dale method. Demographic data and treatment given to the patients were obtained from their case records.
RESULTS:
Fifty-six females and five males were studied from three ethnic groups. In 57 patients with erosions, rheumatoid factor was detected in 80%, HLA-DR4 in 40%, HLA-DRB1*0405 in 24% and shared epitope (SE) in 31%. The median delay in starting DMARDs was 24 months. The presence of rheumatoid factor, HLA-DR4 and HLA-DRB1*0405 were not significantly associated with a worse erosive score. Patients who possessed the SE had a higher erosive scores, compared to those who did not (p = 0.05). Concurrently, a delay in starting DMARD was associated with a high erosive score (p = 0.023, r = 0.348). However, after adjustment for the delay in starting DMARD, SE was no longer significantly associated with the erosive score.
CONCLUSIONS:
In these patients, the delay in starting DMARDs had a greater influence on the erosive score than SE alone. Whilst we cannot discount the contribution of the SE presence, we would advocate early usage of DMARDs in every RA patient to reduce joint erosions and future disability.
Femoral neck fracture non-unions often present with significant difficult treatment decision as regards to surgical options and the risk of complication. We present three cases of femoral neck non-union treated with double screw stabilization technique using sliding compression hip screw and anti-rotational screw. The rationale for opting to these simple implants in our setting is discussed.
A 7-year-old boy, referred with lymphoma, presented with prolonged fever and intra-abdominal lymphadenopathy demonstrated on computed tomography (CT) of the abdomen. Blood culture isolated Penicillium marneffei. The patient was subsequently proven serologically to be positive for human immunodeficiency virus (HIV). Treatment with amphotericin B followed by itraconazole was successful. A high level of clinical suspicion and awareness is necessary for early diagnosis of penicilliosis, especially in an era of an increasing prevalence of HIV in this region.
The cervical pedicle diameter size differs between Asians and non-Asians. The authors studied the transverse pedicle diameter of the C2-C7 of the cervical spine in a Malaysian population using computerized tomography (CT) measurements. The transverse diameter of the pedicle is the determinant of the feasibility of this technique because the sagittal diameter of the pedicle has been wider than the transverse pedicle diameter.
We present a case of a foreign body which migrated to the maxillary ostia by mucociliary action from its initial location on the floor of the maxillary sinus where it was traumatically introduced. This report illustrates that a powerful mechanism of mucociliary action can cause relatively heavy objects within the maxillary sinus to migrate naturally to the sinus ostia against gravitational force.
The accuracy of multi-detector computed tomographic (MDCI) coronary angiography (CTA) is dependant on image quality as well as the experience of the operator. Established centers have reported negative predictive values of over 95%. The aim of our study was to investigate the accuracy and feasibility of CTA for the assessment of haemodynamically significant coronary stenosis in a center with very early experience (<6 months) utilizing the improved spatial and temporal resolutions of the latest generation 64-row MDCI scanner. One hundred and twenty eight patients (93 male, 35 female; mean age 56.2 +/- 9.5 years) with suspected or known coronary artery disease underwent both CIA and conventional coronary angiographv (CCA). The sensitivity, specificity, positive (PPV) and negative (NPV) predictive values for stenoses > or =50% by CIA compared to CCA were 70%, 97%, 70% and 97% respectively. Evaluation of main and proximal segments in patients with good quality images (78% of patients) produced values of 94%, 95%, 74% and 99% respectively. The improved spatial and temporal resolutions of 64-row MJ) CT provided a high negative predictive value in assessing significant coronary artery stenosis even in a centre with very early experience. However, new centers embarking on CTA might not be able to reproduce the results reported by more experienced centers.
We report on our early experiences with the Press Fit Condylar Rotating Platform (PFC-RP) total knee replacement prosthesis at University Malaya Medical Centre. This new prosthesis was introduced to Malaysia in 2001. It combines the rotating platform technology of Low Contact Stress (LCS) and the modularity of Press Fit Condylar (PFC) system. We performed 18 knee replacements using cruciate retaining prosthesis without patellar resurfacing in 10 patients and followed them up over a period of 16-month. A new operative strategy was developed to match the flexion and extension gaps. The pre- and post-operative assessments were made according to the American Knee Society Scores (AKSS). Post-operative pain relief, range of motion, knee score and functional score showed promising early results. The average knee rating improved from 28 to 91 (range 75-94). Average functional assessment improved from 26 to 82 (range 75-90). The radiographic assessments show correction of an average pre-operative varus of 140 to post-operative valgus of 50 (range 4-70). Early infection occurred in two knees. Both responded to aggressive debridement and antibiotics. Stiffness was encountered in one patient. There were no spinouts of the insert. We are satisfied that the implants are performing well at the one-year mark and will continue monitor this cohort.
Revision surgery following failed open reduction for developmental dysplasia of the hip (DDH) is technically demanding. We reviewed 12 patients in our institution that required a revision surgery between January 1994 and December 2003. The aims of this study are to identify the causes of redislocation after the primary open reduction and to determine the clinical and radiological outcome after the revision surgery. The mean age at presentation for DDH was 31 months (range 1-84) and the mean age at primary open reduction surgery was 38 months (range 15-84) and the mean age at revision surgery was 69 months (range 21-180). The mean follow-up period after revision surgery was 20 months (range 3-84). All the revision surgery was performed via an anterior Smith Peterson approach. The most common cause for redislocation was inadequate exposure and failure to release the obstructing soft tissues around the hip. The bony factors for redislocation included failure to perform a femoral shortening and excessive derotation of an anteverted femoral head combined with a Salter osteotomy. Three cases with posterior acetabular wall deficiency needed immobilization of the hip in extension as the hip tended to dislocate in flexion. Six patients had limb length discrepancy ranging from 1 cm to 4 cm and 50% developed avascular necrosis. Only 2 patients were asymptomatic and the majority had a limp and limitation of motion. All were pain free except one. In view of the technically demanding surgery and poor results after revision, the surgeon should recognize the pathology and ensure that the primary procedure achieves a stable and concentric reduction.
Matched MeSH terms: Hip Dislocation, Congenital/radiography
We studied the factors influencing the mid-term outcomes of tibial plateau fractures treated conservatively (n=21) and surgically (n=27) from December 1994 to December 1997. Joint stability was an important prognostic determinant. In the surgical group, the most important factor was good anatomical reduction. Functional outcomes were comparable between the conservative and surgical groups. We concluded that conservative treatment is a valid option for fractures with minimal displacement and surgical treatment is justified for severely displaced or depressed fractures. Attention must be paid to the recognition and restoration of joint stability and articular surface congruency for a satisfactory outcome.
Femoral interlocking nailing requires fluoroscopic assistance for insertion of the nail and distal screws. In this study, scattered radiation to the eye and hand of the operating surgeon was measured during the procedure. Thermo-luminescent dosimeter (TLD) was used to quantify the dose received by the surgeon. The mean radiation exposure time during the procedure was 3.89 minutes. The mean scattered radiation doses to the hand and eye were 0.27 mSv and 0.09 mSv per procedure respectively. These very low doses have made a surgeon very unlikely to receive more than the recommended annual dose limit set by the National Council on Radiological Protection.
The Fitmore titanium mesh cementless acetabular component in 115 hip arthroplasties was reviewed at an average of 33 months of follow-up. None were revised nor had infection. One hip dislocated 4 years postoperatively. Two femoral components were revised. The average Harris Hip Score at the last follow-up was 90 points. In the 96 sets of radiographs available, there was no loosening or new radiolucency. One hip had nonprogressive osteolysis adjacent to a screw. This press-fit cup has its polar region flattened and is rim loading. Noncontact (gaps) at the acetabular floor is expected and is not critical for fixation. In all but 6 hips, these gaps filled. In 5 hips, a minimal gap (
This is a retrospective study to evaluate our early experience of using selective microcoil embolization in patients who had gastrointestinal (GI) haemorrhage. From December 2002 to December 2003, six patients with GI haemorrhage (upper GI, n = 1; lower GI, n = 5) underwent superselective microcoil embolization. Microcatheters were used to carry out embolizations in branches of the superior mesenteric artery. Microcoils were used in five patients and a combination of microcoils and embolospheres was used in one patient. Technical success (bleeding target devascularization) was achieved in all patients who showed active bleeding at the time of angiography. Two patients had recurrent bleeding within 24 h of embolization, of which one (16.7%) died. The other patient did not require active intervention as bleeding was minimal and resolved with conservative management. Satisfactory clinical success (no rebleeding after 30 days) was achieved in five patients. No clinical signs and symptoms of bowel ischaemia occurred in these patients. Follow-up colonoscopy carried out in two patients did not show any signs of ischaemia in the affected bowel segments. Superselective microcoil embolization is an effective and safe method of controlling and arresting bleeding in GI haemorrhage.