Displaying publications 21 - 34 of 34 in total

Abstract:
Sort:
  1. Sarmani S, Kuan LL, Bakar MA
    Biol Trace Elem Res, 1990 7 1;26-27:497-502.
    PMID: 1704755
    Kidney stone samples of the types calcium oxalate, uric acid, and xanthine were analyzed for their elemental contents by neutron activation analysis to study both the elemental correlation and influence of element on stone precipitation processes. Elements, such as Al, Au, Br, Ca, Cl, Co, Cr, Fe, Hg, I, K, Mg, Na, Sb, Se, Sr, and Zn, were determined quantitatively. Calcium oxalate stones contained higher concentration of all the elements analyzed compared to uric acid or xanthine stones. The concentrations of Cl, Fe, K, Na, Sr, and Zn were relatively higher than Au, Co, Cr, and Sb. A positive correlation exists between Ca and Zn, whereas a negative correlation exists between Sr and Ca. Zinc may play an important role in the formation of calcium oxalate stone.
    Matched MeSH terms: Neutron Activation Analysis/methods*
  2. Yeong CH, Blackshaw PE, Ng KH, Abdullah BJ, Blaauw M, Dansereau RJ, et al.
    Appl Radiat Isot, 2011 Sep;69(9):1181-4.
    PMID: 21550260 DOI: 10.1016/j.apradiso.2011.04.017
    Neutron activation of Sm-152 offers a method of radiolabeling for the in vivo study of oral dose formulations by gamma scintigraphy. Reproducibility measurements are needed to ensure the robustness of clinical studies. 204 enteric-coated guaifenesin core tablets (10mg of Sm(2)O(3)) were irradiated by thermal neutrons to achieve 1 MBq at 48 h. Administered activities were 0.86±0.03 MBq. Good reproducibility (CV=3.5%) was observed over 24 weeks ensuring that volunteer doses were within the dose reference level of 0.8 mSv.
    Matched MeSH terms: Neutron Activation Analysis
  3. Ng KH, Bradley DA, Looi LM, Mahmood CS, Wood AK
    Appl Radiat Isot, 1993 Mar;44(3):511-6.
    PMID: 8472024
    Multi-elemental quantitative analyses of 15 paired samples of normal and malignant human breast tissue by instrumental neutron activation analysis are reported. The elements, Al, Br, Ca, Cl, Co, Cs, Fe, K, Na, Rb, Zn were detected. Significantly elevated concentration levels were found for Al, Br, Ca, Cl, Cs, K, Na, Zn in malignant compared to normal tissue. Although the role of elemental composition in breast cancer is unclear, this finding may be of importance as another parameter for differentiating normal from malignant tissue.
    Matched MeSH terms: Neutron Activation Analysis
  4. Wee B, Ebihara M
    Sains Malaysiana, 2017;46:605-613.
    We report herewith the study of fingernail clippings obtained from the residents of Tokyo, Japan. A total of 18 participants with no health problems and occupational exposure to metals were recruited to provide fingernails samples for this study. Through the use of instrumental neutron activation analysis (INAA), 18 elements (Ag, Al, As, Ca, Cl, Co, Cu, Fe, Hg, K, Mg, Mn, Na, S, Sb, Se, V, and Zn) were determined. The results showed that the toxic elements in the fingernails are in the lower range when compared to literature values. There were no chronic exposures to toxic elements such as As and Hg found. The level of Hg found is lower than that reported 20 years ago, possibly due to the strict regulation control in Japan on the release of Hg to the environment. The elements Se and Zn are found to be rather uniformly distributed among participants and are in agreement with results from other countries. There were no significant differences in elemental concentrations due to genders and smoking habits. The overall data from this study showed similar concentrations to those of healthy participants from other countries. Thus, the current data could represent the background level of elemental concentrations in fingernails of residents in Tokyo, which could serve as reference values for future study.
    Matched MeSH terms: Neutron Activation Analysis
  5. Elias MS, Ibrahim S, Samuding K, Kantasamy N, Rahman SA, Hashim A
    Appl Radiat Isot, 2019 Sep;151:116-123.
    PMID: 31174051 DOI: 10.1016/j.apradiso.2019.05.038
    A study was carried out to determine the concentrations of rare earth elements (REEs) in Linggi river sediments collected from 113 sampling locations. The sediment analysis was performed by Neutron activation analysis (NAA) and Inductively coupled plasma - mass spectrometry (ICP-MS). The results of Linggi river sediment were normalized to "recent" reference shale values. The means of total concentrations of REEs (ΣREE), light REEs (ΣLREE) and heavy REEs (ΣHREE) in Linggi sediment were 241.2, 219.2, and 22.0 mg/kg, respectively, which indicates enrichment compared to ΣREE, ΣLREE and ΣHREE reference shale values. Results obtained from enrichment factors (EF) show no enrichment to moderate enrichment of Linggi sediments, indicating the sources of REEs pollution originated from natural and land-based activities. A similar pattern was observed by comparing the REEs values of Linggi sediments to other references shale values. Ce (δCe) and Eu (δEu) anomalies indicate Linggi sediments showed positive anomaly of Ce whilst negative anomaly of Eu.
    Matched MeSH terms: Neutron Activation Analysis
  6. Shamsiah A. Rahman, Mohd Suhaimi Hamzah, Abdul Khalik Wood, Md Suhaimi Elias, Nazaratul Ashifa Abdullah Salim, Ezwiza Sanuri
    MyJurnal
    Chemical composition of fine (PM2.5) aerosol samples collected for the 5 years period (2001- 2005) using Gent Stacked filter unit sampler at Klang Valley (3 o 10 ’ 30 ’’ N, 101 o 43 ’ 24 ’’ E) were analysed using Neutron Activation Analysis (NAA) and Proton Induced X-ray Emission (PIXE). Results of the study show that the major component of the fine aerosol was black carbon and sulfur with the mass concentration ranged from 4.4 - 6.7µg m -3 and 1.2 - 1.9µg m -3 , respectively. The total fine aerosol mass concentration were in the ranged of 25 - 31µg m -3 with the reconstructed mass was about 50% as relative to the gravimetric mass. Statistical method, factor analysis with varimax approach has been applied to the aerosol composition data for the fingerprint identification. The analysis produces five identified fingerprint represent soil, industry, motor vehicles/biomass burning and Pb and Zn sources. There is also an unidentified source that could be related to unknown industrial activities.
    Matched MeSH terms: Neutron Activation Analysis
  7. Muhamat Omar, Zalina Laili, Mohd Suhaimi Hamzah
    MyJurnal
    Qualitative and quantitative analysis of samples require good judgment from the analysts. These two aspects in gamma spectrometric analysis of Proficiency Test and solid radioactive waste samples for the determination of radionuclides are discussed. It is vital to judge and decide what energy peaks belong to which radionuclides prior to the creation of customized radionuclide library for the analysis of specific samples. Corrections due to radionuclide decay and growth, and the half-life assigned to a particular radionuclide in the uranium and thorium series are also discussed. Discussion on judgment to confirm the presence of thorium in food samples based on gamma spectrometry and neutron activation analysis is also provided.
    Matched MeSH terms: Neutron Activation Analysis
  8. Siong, Wee Boon, Ebihara, Mitsuru
    MyJurnal
    Prompt gamma-ray analysis (PGA) and instrumental neutron activation analysis (INAA) are essential for the study of rare samples such as meteorites because of non-destructivity and relatively being free from contaminations. The objective of this research is to utilize PGA and INAA techniques for comparative study and apply them to meteorite analyses. In this study, 11 meteorite samples received from the Meteorite Working Group of NASA were analyzed. The Allende meteorite powder was included as quality control material. Results from PGA and INAA for Allende showed in good agreement with literature values, signifying the reliabilities of these two methods. Elements Al, Ca, Mg, Mn, Na and Ti were determined by both methods and their results are compared. Comparison of PGA and INAA data using linear regression analysis showed correlations coefficients r2 > 0.90 for Al, Ca, Mn and Ti, 0.85 for Mg, and 0.38 for Na. The PGA results for Na using 472 keV were less accurate due to the interference from the broad B peak. Therefore, Na results from INAA method are preferred. For other elements (Al, Ca, Mg, Mn and Ti), PGA and INAA results can be used as cross-reference for consistency. The PGA and INAA techniques have been applied to meteorite samples and results are comparable to literature values compiled from previously analyzed meteorites. In summary, both PGA and INAA methods give reasonably good agreement and are indispensable in the study of meteorites.
    Matched MeSH terms: Neutron Activation Analysis
  9. Muneer Saleh, Ahmad Suhaimi
    MyJurnal
    An instrumental neutron activation analytical (INAA) technique is used for the determination of thirty elements in five coal samples collected from Kapar power station, imported from Indonesia and Australia. Analyses of the samples are being associated with standards. All irradiations were performed in the nuclear reactor of Malaysia Nuclear Agency (MNA). Samples were counted by Hyper Pure Germanium (HPGe) detector for short period irradiations at MNA, while for the long period irradiations the samples were counted at Universiti Kebangsaan Malaysia (UKM). The concentrations of thirty elements have been determined: The major components are Cl, Ca, Mg, K, Fe, Ti and Na with the mean concentrations in the range between 70±69 ppm- 6100±1639 ppm; and the trace elements are Zr, V, Mn , Sc, Cr, Co, As ,Br ,Rb ,Sb ,Ba , La, Ce, Nd, Sm, Eu, Tb, Yb, Lu, Hf, Th, U and Ta with the mean concentrations in the range between 0.1381±0.0202 - 69.0±2.8 ppm. The results have been compared to the reported data of eight coal samples from the United States and the reported data of Australian bituminous coal.
    Matched MeSH terms: Neutron Activation Analysis
  10. Nashriyah Mat, Shamsiah Abdul Rahman, Ismail Che Haron, Mazleha Maskin, Mohd. Razi Ismail
    MyJurnal
    A study to determine the influence of soil water status on the physiology of rice plant Oryza sativa var. MR220 after panicle initiation stage was carried out at Ladang Merdeka Mulong Lating in the Kemubu Agricultural Development Authority (KADA) area, Kelantan. Five water management treatments imposed on direct seeded rice were; T1. Continuous flooding, T2. Early flooding up to panicle initiation stage followed by saturated (F55-saturated), T3. Early flooding for the first month followed by saturated (F-30 saturated), T4. Continuous saturated, and T5. Continuous field capacity condition throughout the growth stage. The treatments were arranged in Randomized Complete Block Design (RCBD) with four replicates. In-situ stomatal conductance measurement was carried out at 68 DAS (days after seeding) and the elemental analysis of soil and plant samples was carried out using the Instrumental Neutron Activation Analysis (INAA). Results from this study showed significant differences between treatments for soil moisture content and plant moisture content, but no significance different in leaf stomatal conductance. Rice plant moisture, soil moisture and leaf stomatal conductance showed no interaction. Early flooding up to panicle initiation stage followed by saturated (T2: F55-saturated) resulted in higher plant moisture content. Soil plant transfer coefficient was highest in continuous saturated (T4) for nitrogen, early flooding for the first month followed by saturated (T3: F-30 saturated) for potassium, continuous field capacity condition throughout the growth stage (T5) for magnesium, and continuous flooding (T1) for sodium.
    Matched MeSH terms: Neutron Activation Analysis
  11. Ng KH, Ong SH, Bradley DA, Looi LM
    Appl Radiat Isot, 1997 Jan;48(1):105-9.
    PMID: 9022216
    Discriminant analysis of six trace element concentrations measured by instrumental neutron activation analysis (INAA) in 26 paired-samples of malignant and histologically normal human breast tissues shows the technique to be a potentially valuable clinical tool for making malignant-normal classification. Nonparametric discriminant analysis is performed for the data obtained. Linear and quadratic discriminant analyses are also carried out for comparison. For this data set a formal analysis shows that the elements which may be useful in distinguishing between malignant and normal tissues are Ca, Rb and Br, providing correct classification for 24 out of 26 normal samples and 22 out of 26 malignant samples.
    Matched MeSH terms: Neutron Activation Analysis/statistics & numerical data
  12. Yusof AM, Rahman NA, Wood AK
    Biol Trace Elem Res, 1994;43-45:239-49.
    PMID: 7710833
    Trace elements, such as As, Co, Cr, Hg, Sb, and Zn, were determined by neutron activation analysis (NAA), whereas Cd, Cu, and Pb were determined by graphite furnace atomic absorption spectroscopy (GFAAS) in clam, crab, prawn, swamp cerith, and mussel samples after digestion by microwave heating under controlled conditions before eluting the solutions through a column of a chelating resin, Chelex-100. The standard used in the determination of percentage volatile elements retained by microwave digestion and also in the activation process was Lobster Hepatopancreas TORT-1, whereas known mixed standards were prepared from nitrate salts to determine the efficiency of the separation procedure at a controlled pH. Mercury and lead detected in crabs exceeded the maximum permissible level. Some species also showed a high affinity toward certain elements, and their levels of accumulation in the tissues of these species corresponded with the concentration of these elements in sediments, especially at sites in the vicinity of an industrial zone.
    Matched MeSH terms: Neutron Activation Analysis
  13. Ariffin AF, Yusof N, Mohd S, Rahman SA, Ramalingam S, Mansor A, et al.
    Cell Tissue Bank, 2019 Dec;20(4):527-534.
    PMID: 31456097 DOI: 10.1007/s10561-019-09785-4
    Calcium contents of demineralised human cortical bone determined by titrimetric assay and atomic absorption spectrophotometry technique were verified by comparing to neutron activation analysis which has high recovery of more than 90%. Conversion factors determined from the comparison is necessary to correct the calcium content for each technique. Femurs from cadaveric donors were cut into cortical rings and demineralised in 0.5 M hydrochloric acid for varying immersion times. Initial calcium content in the cortical bone measured by titration was 4.57%, only 21% of the measurement by neutron activation analysis; while measured by atomic absorption spectrophotometer was 13.4%, only 61% of neutron activation analysis. By comparing more readings with the measurements by neutron activation analysis with 93% recovery, a conversion factor of 4.83 was verified and applied for the readings by titration and 1.45 for atomic absorption spectrophotometer in calculating the correct calcium contents. The residual calcium content started to reduce after the cortical bone was demineralised in hydrochloric acid for 8 h and reduced to 13% after 24 h. Using the linear relationship, the residual calcium content could be reduced to less than 8% after immersion in hydrochloric acid for 40 h. Atomic absorption spectrophotometry technique is the method of choice for calcium content determination as it is more reliable compared to titrimetric assay.
    Matched MeSH terms: Neutron Activation Analysis
  14. Alani AH, Toh CG
    Oper Dent, 1997 Jul-Aug;22(4):173-85.
    PMID: 9484158
    Matched MeSH terms: Neutron Activation Analysis
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links