Affiliations 

  • 1 Hospital Sultanah Aminah
Medical Journal of Malaysia, 2007;62(5):370-374.
MyJurnal

Abstract

Six hundred and fifty five central venous catheters (CVC) in 496 patients in the intensive care unit of Hospital Sultanah Aminah were studied to determine the incidence and risk factors for central venous catheter-related blood stream infection (CR-BSI). CR-BSI was diagnosed in 38 catheters, giving an incidence of 9.43 CR-BSI per 1,000 catheter days. The mean duration in situ was 8.4 ± 4.9 days for infected CVCs and 6.0 ± 3.8 days for non infected CVCs (p = 0.001). CVCs inserted in ICU had the highest infection rate (9.4%) compared to those inserted in the operating theatre (1.4%) and ward (2.8%) (p = 0.001). The highest rate of CR-BSI occurred with 4-lumen catheters (usually inserted when patients needed total parenteral nutrition) with a percentage of 15.8%. The majority of the CVCs (97.9%) were inserted via the subclavian or the internal jugular routes and there was no statistical difference in CR-BSI between them (p = 0.83). Number of attempts more than one had a higher rate of CR-BSI compared to single attempt with percentage of 7.0% vs. 4.8% (p = 0.22). The top two organisms were Klebseilla pneumoniae and Pseudomonas aeruginosa. In conclusion, the incidence of CR-BSI in our ICU was 9.43 CR-BSI per 1,000 catheter days. The risk factors were duration of CVC in situ, venue of insertion and use of 4 lumen catheter for total parenteral nutrition. The site of insertion, number of lumen up to 3 lumens and the number of attempts were not risk factors.