Displaying all 5 publications

Abstract:
Sort:
  1. Abhishek A, Curran DJ, Bilwani F, Jones AC, Towler MR, Doherty M
    Rheumatology (Oxford), 2016 Feb;55(2):379-80.
    PMID: 26342227 DOI: 10.1093/rheumatology/kev339
    Study done in England
    Matched MeSH terms: Uric Acid/analysis*
  2. Abdul Aziz SFN, Hui OS, Salleh AB, Normi YM, Yusof NA, Ashari SE, et al.
    Anal Bioanal Chem, 2024 Jan;416(1):227-241.
    PMID: 37938411 DOI: 10.1007/s00216-023-05011-z
    This study aims to investigate the influence of copper(II) ions as a cofactor on the electrochemical performance of a biocomposite consisting of a mini protein mimicking uricase (mp20) and zeolitic immidazolate framework-8 (ZIF-8) for the detection of uric acid. A central composite design (CCD) was utilized to optimize the independent investigation, including pH, deposition potential, and deposition time, while the current response resulting from the electrocatalytic oxidation of uric acid was used as the response. The statistical analysis of variance (ANOVA) showed a good correlation between the experimental and predicted data, with a residual standard error percentage (RSE%) of less than 2% for predicting optimal conditions. The synergistic effect of the nanoporous ZIF-8 host, Cu(II)-activated mp20, and reduced graphene oxide (rGO) layer resulted in a highly sensitive biosensor with a limit of detection (LOD) of 0.21 μM and a reproducibility of the response (RSD = 0.63%). The Cu(II)-activated mp20@ZIF-8/rGO/SPCE was highly selective in the presence of common interferents, and the fabricated layer exhibited remarkable stability with signal changes below 4.15% after 60 days. The biosensor's reliable performance was confirmed through real sample analyses of human serum and urine, with comparable recovery values to conventional HPLC.
    Matched MeSH terms: Uric Acid/analysis
  3. Sarmani S, Kuan LL, Bakar MA
    Biol Trace Elem Res, 1990 7 1;26-27:497-502.
    PMID: 1704755
    Kidney stone samples of the types calcium oxalate, uric acid, and xanthine were analyzed for their elemental contents by neutron activation analysis to study both the elemental correlation and influence of element on stone precipitation processes. Elements, such as Al, Au, Br, Ca, Cl, Co, Cr, Fe, Hg, I, K, Mg, Na, Sb, Se, Sr, and Zn, were determined quantitatively. Calcium oxalate stones contained higher concentration of all the elements analyzed compared to uric acid or xanthine stones. The concentrations of Cl, Fe, K, Na, Sr, and Zn were relatively higher than Au, Co, Cr, and Sb. A positive correlation exists between Ca and Zn, whereas a negative correlation exists between Sr and Ca. Zinc may play an important role in the formation of calcium oxalate stone.
    Matched MeSH terms: Uric Acid/analysis
  4. Omar MN, Salleh AB, Lim HN, Ahmad Tajudin A
    Anal Biochem, 2016 09 15;509:135-141.
    PMID: 27402177 DOI: 10.1016/j.ab.2016.06.030
    Measurement of the uric acid level in the body can be improved by biosensing with respect to the accuracy, sensitivity and time consumption. This study has reported the immobilization of uricase onto graphene oxide (GO) and its function for electrochemical detection of uric acid. Through chemical modification of GO using 1-ethyl-3-(dimethylaminopropyl) carbodiimide (EDC) and N-hydroxysulfosuccinimide (NHS) as cross-linking reagents, the enzyme activity of the immobilized uricase was much comparable to the free enzyme with 88% of the activity retained. The modified GO-uricase (GOU) was then subjected to electrocatalytic detection of uric acid (UA) via cyclic voltammetry (CV). For that reason, a glassy carbon electrode (GCE) was modified by adhering the GO along with the immobilized uricase to facilitate the redox reaction between the enzyme and the substrate. The modified GOU/GCE outperformed a bare electrode through the electrocatalytic activity with an amplified electrical signal for the detection of UA. The electrocatalytic response showed a linear dependence on the UA concentration ranging from 0.02 to 0.49 mM with a detection limit of 3.45 μM at 3σ/m. The resulting biosensor also exhibited a high selectivity towards UA in the presence of other interference as well as good reproducibility.
    Matched MeSH terms: Uric Acid/analysis*