Displaying all 4 publications

Abstract:
Sort:
  1. Yap KL
    Malays J Pathol, 1994 Jun;16(1):49-56.
    PMID: 16329576
    The aim of this study was to optimize the conditions for the passive adsorption of polyclonal antibody onto plain surface polystyrene latex particles and its performance in a slide latex agglutination test for rotavirus antigen detection. Cleaning of latex particles by washing through repetitive centrifuging, decanting and resuspending in distilled water was adequate in removing surfactants from the particles' surfaces to enable coating. A study of antibody concentration, incubation temperature and buffer pH revealed that optimum coating was achieved with a 3-fold excess of antibody to the calculated total particle surface capacity for the antibody in a glycine-saline buffer of pH 9.2 at 40 degrees C for 4 hours. The ionic strength and pH of the latex suspending buffer and the sample buffer were critical factors determining the sensitivity of the test and the appearance of non-specific agglutination. Ultrasonication, addition of glycerol and Tween 20, either individually or in combination, were able to suppress non-specific agglutination in some batches of latex reagents. Polyethylene glycol 6000 enhanced the quality of agglutination as well as reduced the time of its appearance, especially in reagents that produced poor agglutination.
    Matched MeSH terms: Rotavirus/immunology
  2. Rasool NB, Green KY, Kapikian AZ
    J Clin Microbiol, 1993 Jul;31(7):1815-9.
    PMID: 8394376
    The distribution of rotavirus G (VP7) serotypes circulating in four locations in Malaysia, representing three geographical areas, was evaluated in 341 RNA-positive stool specimens obtained discontinuously between 1977 and 1988 from infants and young children under the age of five years who were hospitalized with acute gastroenteritis. A total of 306 specimens (256 stool suspensions and 50 that were adapted to growth in tissue culture) that were rotavirus positive by the confirmatory enzyme-linked immunosorbent assay (ELISA) were examined for serotype by ELISA utilizing monoclonal antibodies to rotavirus G serotype 1, 2, 3, 4, or 9. One hundred eighty (59%) of the 306 specimens could be serotyped; of these 180 specimens, 71% were serotype 4, 15% were serotype 1, 4% were serotype 2, and 4% were serotype 3. Serotype 9 rotavirus was not detected. Most (71%) of the specimens tested were obtained in 1988, when serotype 4 predominated in three locations in West Malaysia; no single serotype was predominant in a limited number of specimens from East Malaysia.
    Matched MeSH terms: Rotavirus/immunology
  3. Leong YK, Awang A
    Microbiol. Immunol., 1990;34(2):153-62.
    PMID: 2161071
    Rotaviral infections in cynomolgus monkeys (Macaca fasicularis) were studied to ascertain its suitability as a model of infection and diarrhea caused by group A human rotaviruses. Formula-fed monkeys were used as they could be observed closely. Experimental rotaviral infection of cynomolgus monkeys was age-dependent; only young monkeys were readily infected. Formula-fed newborns were readily infected with cell-culture-adapted human (WA) and simian (SA11) viruses and with a rotavirus from a human fecal specimen. However, diarrhea was detected only in very young animals. A number of rotaviral shedding patterns as a function of time were observed. Although there was no typical viral shedding pattern which represented exclusive association of viral infection with diarrhea, the initial level of viral excretion and the maximum level of viral shedding attained were much higher in animals with diarrhea. Seroconversion occurred in less than half of the inoculated animals. The presence of maternal rotaviral antibodies did not prevent infection or diarrhea.
    Matched MeSH terms: Rotavirus/immunology
  4. Kirnpal-Kaur BS, Yap KL, Tan SC
    Malays J Pathol, 1997 Dec;19(2):133-6.
    PMID: 10879254
    A blocking test was incorporated into the commercial IDEIA Adenovirus test (DAKO Diagnostics Ltd., Cambridgeshire, UK) to detect false positive results when faecal specimens were tested for adenovirus antigen. Immune rabbit serum raised against pooled adenovirus particles from human faecal specimens, together with the pre-immune serum, was used. Assessment of positive showed that false positives were produced under two different conditions: when results were based on visual determination instead of a cut-off value determined from photometric reading, and when absorbance values were not immediately read at the end of the test. Under the optimum condition for reading and assessment of test results (immediate reading and photometric determination), 11% of 65 adenovirus-positive samples were checked by the blocking ELISA as false positives. The rest of the specimens showed blocking of positive absorbance values by 70 to 98%. ELISA was found to be more sensitive than immune electron microscopy on samples with lower antigen concentration.
    Matched MeSH terms: Rotavirus/immunology
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links