Displaying all 8 publications

Abstract:
Sort:
  1. Konduk BA, Ucisik AH
    Med J Malaysia, 2004 May;59 Suppl B:53-4.
    PMID: 15468815
    The effect of hemodialysis on the mechanical behavior of a cellulosic Hemophane ME-IOH and one Polysulfone type hollow fibers was investigated. Mechanical tests showed that the deformation of polysulfone type of hollow fibers is entirely different than that of the other dialyser for the samples used and unused in hemodialysis. All the samples exposed to the dialysis showed decreased in ductility. Fracture surface studies proved that there was some alignment on the fracture surface. XRD and DSC experiments revealed structural changes had occurred.
    Matched MeSH terms: Renal Dialysis/instrumentation*
  2. Irfan M, Irfan M, Shah SM, Baig N, Saleh TA, Ahmed M, et al.
    Mater Sci Eng C Mater Biol Appl, 2019 Oct;103:109769.
    PMID: 31349444 DOI: 10.1016/j.msec.2019.109769
    Non-covalent electrostatic interaction between amide nitrogen and carbonyl carbon of shorter chain length of polyvinylpyrrolidone (PVP-k25) was developed with in-house carboxylic oxidized multiwall carbon nanotubes (O-MWCNT) and then blended with Polyethersulfone (PES) polymer. FTIR analysis was utilized to confirm bonding nature of nano-composites (NCs) of O-MWCNT/PVP-k25 and casting membranes. Non-solvent induces phase separation process developed regular finger-like channels in composite membranes whereas pristine PES exhibited spongy entities as studied by cross sectional analysis report of FESEM. Further, FESEM instrument was also utilized to observe the dispersion of O-MWCNT/PVP based nanocomposite (NCs) with PES and membranes leaching phenomena analysis. Contact angle experiments described 24% improvement of hydrophilic behaviour, leaching ratio of additives was reduced to 1.89%, whereas water flux enhanced up to 6 times. Bovine serum albumin (BSA) and lysozyme based antifouling analysis shown up to 25% improvement, whereas 84% of water flux was regained after protein fouling than pristine PES. Anticoagulant activity was reported by estimating prothrombin, thrombin, plasma re-calcification times and production of fibrinogen cluster with platelets-adhesions photographs and hemolysis experiments. Composite membranes exhibited 3.4 and 3 times better dialysis clearance ratios of urea and creatinine solutes as compared to the raw PES membrane.
    Matched MeSH terms: Renal Dialysis/instrumentation*
  3. Irfan M, Irfan M, Idris A, Baig N, Saleh TA, Nasiri R, et al.
    J Biomed Mater Res A, 2019 03;107(3):513-525.
    PMID: 30484939 DOI: 10.1002/jbm.a.36566
    This study focused to optimize the performance of polyethersulfone (PES) hemodialysis (HD) membrane using carboxylic functionalized multiwall carbon nanotubes (c-MWCNT) and lower molecular weight grade of polyvinylpyrrolidone (PVP-k30). Initially, MWCNT were chemically functionalized by acid treatment and nanocomposites (NCs) of PVP-k30 and c-MWCNT were formed and subsequently blended with PES polymer. The spectra of FTIR of the HD membranes revealed that NCs has strong hydrogen bonding and their addition to PES polymer improved the capillary system of membranes as confirmed by Field Emission Scanning Electron Microscope (FESEM) and leaching of the additive decreased to 2% and hydrophilicity improved to 22%. The pore size and porosity of NCs were also enhanced and rejection rate was achieved in the establish dialysis range (<60 kDa). The antifouling studies had shown that NCs membrane exhibited 30% less adhesion of protein with 80% flux recovery ratio. The blood compatibility assessment disclosed that NCs based membranes showed prolonged thrombin and prothrombin clotting times, lessened production of fibrinogen cluster, and greatly suppressed adhesion of blood plasma than a pristine PES membrane. The results also unveiled that PVP-k30/NCs improved the surface properties of the membrane and the urea and creatinine removal increased to 72% and 75% than pure PES membranes. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 107A: 513-525, 2019.
    Matched MeSH terms: Renal Dialysis/instrumentation*
  4. Zailani MZ, Ismail AF, Sheikh Abdul Kadir SH, Othman MH, Goh PS, Hasbullah H, et al.
    J Biomed Mater Res A, 2017 05;105(5):1510-1520.
    PMID: 28000366 DOI: 10.1002/jbm.a.35986
    In this study, poly (1,8-octanediol citrate) (POC) was used to modify polyethersulfone (PES)-based membrane to enhance its hemocompatibility. Different compositions of POC (0-3%) were added into the polyethersulfone (PES) dope solutions and polyvinylpyrrolidone (PVP) was used as pore forming agent. The hemocompatible POC modified PES membranes were fabricated through phase-inversion technique. The prepared membranes were characterized using attenuated total reflectance-Fourier transform infrared (ATR-FTIR), thermogravimetric analysis (TGA), scanning electron microscopy (SEM), Atomic-force microscopy (AFM), contact angle, Zeta-potential, membrane porosity and pore size and pure water flux (PWF) and BSA rejection. The hemocompatibility of the modified PES membranes was evaluated by human serum fibrinogen (FBG) protein adsorption, platelet adhesion, activated partial thromboplastin time (APTT) and prothrombin time (PT), and thrombin-antithrombin III (TAT), complement (C3a and C5a) activation and Ca2+ absorption on membrane. Results showed that by increasing POC concentration, FBG adsorption was reduced, less platelets adhesion, prolonged APTT and PT, lower TAT, C5a and C3a activation and absorb more Ca2+ ion. These results indicated that modification of PES with POC has rendered improved hemocompatibility properties for potential application in the field of blood purification, especially in hemodialysis. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 105A: 1510-1520, 2017.
    Matched MeSH terms: Renal Dialysis/instrumentation
  5. Ashraf MA, Islam A, Butt MA, Hussain T, Khan RU, Bashir S, et al.
    Int J Biol Macromol, 2021 Nov 30;191:872-880.
    PMID: 34571131 DOI: 10.1016/j.ijbiomac.2021.09.131
    Mixed matrix membranes (MMMs) of cellulose acetate/poly(vinylpyrrolidone) (CA/PVP) infused with acid functionalized multiwall carbon nanotubes (f-MWCNTs) were fabricated by an immersion phase separation technique for hemodialysis application. Membranes were characterized using FTIR, water uptake, contact angle, TGA, DMA and SEM analysis. The FTIR was used to confirm the bonding interaction between CA/PVP membrane matrix and f-MWCNTs. Upon addition of f-MWCNTs, TGA thermograms and glass transition temperature indicated improved thermal stability of MMMs. The surface morphological analysis demonstrated revealed uniform distribution of f-MWCNTs and asymmetric membrane structure. The water uptake and contact angle confirmed that hydrophilicity was increased after incorporation of f-MWCNTs. The membranes demonstrated enhancement in water permeate flux, bovine serum albumin (BSA) rejection with the infusion of f-MWCNTs; whereas BSA based anti-fouling analysis using flux recovery ratio test shown up to 8.4% improvement. The urea and creatinine clearance performance of MMMs were evaluated by dialysis experiment. It has been found that f-MWCNTs integrated membranes demonstrated the higher urea and creatinine clearance with increase of 12.6% and 10.5% in comparison to the neat CA/PVP membrane. Thus, the prepared CA/PVP membranes embedded with f-MWCNTs can be employed for wide range of dialysis applications.
    Matched MeSH terms: Renal Dialysis/instrumentation*
  6. Zaman SU, Saif-Ur-Rehman, Zaman MKU, Rafiq S, Arshad A, Khurram MS, et al.
    Artif Organs, 2021 Nov;45(11):1377-1390.
    PMID: 34152645 DOI: 10.1111/aor.14020
    In the current study, a phase inversion scheme was employed to fabricate hydroxyapatite (HA)/polysulfone (PSF)-based asymmetric membranes using a film applicator with water as a solvent and nonsolvent exchanging medium. Fourier Transform Infrared (FTIR) and X-ray diffraction (XRD) spectroscopic studies were conducted to confirm the bonding chemistry and purity of filler. The inherent thick nature of PSF generated sponge-like shape while the instantaneous demixing process produced finger-like pore networks in HA/PSF-based asymmetric membranes as exhibited by scanning electron microscope (SEM) micrographs. The FTIR spectra confirmed noncovalent weak attractions toward the polymer surface. The leaching ratio was evaluated to observe the dispersion behavior of HA filler in membrane composition. Hydrophilicity, pore profile, pure water permeation (PWP) flux, and molecular weight cutoff (MWCO) values of all formulated membranes were also calculated. Antifouling results revealed that HA modified PSF membranes exhibited 43% less adhesion of bovine serum albumin (BSA) together with >86% recovery of flux. Membrane composition showed 74% total resistance, out of which 60% was reversible resistance. Biocompatibility evaluation revealed that the modified membranes exhibited prothrombin time (PT), and thrombin time (TT) comparable with typical blood plasma, whereas proliferation of living cells over membrane surface proved its nontoxic behavior toward biomedical application. The urea and creatinine showed effective adsorption aptitude toward HA loaded PSF membranes.
    Matched MeSH terms: Renal Dialysis/instrumentation
  7. Koh KH, Tan HH
    Med J Malaysia, 2006 Mar;61(1):109-11.
    PMID: 16708747 MyJurnal
    Acute severe intoxication with carbamazepine is associated with seizures, coma and respiratory depression. Traditionally, charcoal haemoperfusion is used to remove the drug. We present a case of carbamazepine intoxication, successfully treated with three hours of high-flux haemodialysis. Thus, haemodialysis using high-flux membranes is a feasible and effective therapeutic option for carbamazepine intoxication.
    Matched MeSH terms: Renal Dialysis/instrumentation
  8. Zare-Zardini H, Amiri A, Shanbedi M, Taheri-Kafrani A, Kazi SN, Chew BT, et al.
    J Biomed Mater Res A, 2015 Sep;103(9):2959-65.
    PMID: 25690431 DOI: 10.1002/jbm.a.35425
    One of the novel applications of the nanostructures is the modification and development of membranes for hemocompatibility of hemodialysis. The toxicity and hemocompatibility of Ag nanoparticles and arginine-treated multiwalled carbon nanotubes (MWNT-Arg) and possibility of their application in membrane technology are investigated here. MWNT-Arg is prepared by amidation reactions, followed by characterization by FTIR spectroscopy, Raman spectroscopy, and thermogravimetric analysis. The results showed a good hemocompatibility and the hemolytic rates in the presence of both MWNT-Arg and Ag nanoparticles. The hemolytic rate of Ag nanoparticles was lower than that of MWNT-Arg. In vivo study revealed that Ag nanoparticle and MWNT-Arg decreased Hematocrit and mean number of red blood cells (RBC) statistically at concentration of 100 µg mL(-1) . The mean decrease of RBC and Hematocrit for Ag nanoparticles (18% for Hematocrit and 5.8 × 1,000,000/µL) was more than MWNT-Arg (20% for Hematocrit and 6 × 1000000/µL). In addition, MWNT-Arg and Ag nanoparticles had a direct influence on the White Blood Cell (WBC) drop. Regarding both nanostructures, although the number of WBC increased in initial concentration, it decreased significantly at the concentration of 100 µg mL(-1) . It is worth mentioning that the toxicity of Ag nanoparticle on WBC was higher than that of MWNT-Arg. Because of potent antimicrobial activity and relative hemocompatibility, MWNT-Arg could be considered as a new candidate for biomedical applications in the future especially for hemodialysis membranes.
    Matched MeSH terms: Renal Dialysis/instrumentation
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links