Displaying all 2 publications

Abstract:
Sort:
  1. Hilmi MR, Che Azemin MZ, Mohd Kamal K, Mohd Tamrin MI, Abdul Gaffur N, Tengku Sembok TM
    Curr Eye Res, 2017 Jun;42(6):852-856.
    PMID: 28118054 DOI: 10.1080/02713683.2016.1250277
    PURPOSE: The goal of this study was to predict visual acuity (VA) and contrast sensitivity function (CSF) with tissue redness grading after pterygium surgery.

    MATERIALS AND METHODS: A total of 67 primary pterygium participants were selected from patients who visited an ophthalmology clinic. We developed a semi-automated computer program to measure the pterygium fibrovascular redness from digital pterygium images. The final outcome of this software is a continuous scale grading of 1 (minimum redness) to 3 (maximum redness). The region of interest (ROI) was selected manually using the software. Reliability was determined by repeat grading of all 67 images, and its association with CSF and VA was examined.

    RESULTS: The mean and standard deviation of redness of the pterygium fibrovascular images was 1.88 ± 0.55. Intra-grader and inter-grader reliability estimates were high with intraclass correlation ranging from 0.97 to 0.98. The new grading was positively associated with CSF (p < 0.01) and VA (p < 0.01). The redness grading was able to predict 25% and 23% of the variance in the CSF and the VA, respectively.

    CONCLUSIONS: The new grading of pterygium fibrovascular redness can be reliably measured from digital images and showed a good correlation with CSF and VA. The redness grading can be used in addition to the existing pterygium grading.
    Matched MeSH terms: Pterygium/physiopathology
  2. Nadarajah G, Ratnalingam VH, Mohd Isa H
    Cornea, 2017 Apr;36(4):452-456.
    PMID: 27941383 DOI: 10.1097/ICO.0000000000001106
    PURPOSE: To evaluate graft stability and recurrence rate between fibrin glue and autologous blood in pterygium conjunctival autograft surgery.

    METHODS: A prospective, randomized, single-blinded clinical trial to assess the efficacy of autologous blood in place of fibrin glue in pterygium surgery. A total of 120 eyes of 111 patients were randomized according to pterygium morphology, to undergo pterygium surgery with autografting using either autologous blood or fibrin glue. All patients were operated by a single surgeon; 58 eyes were operated using fibrin glue and 62 eyes had a conjunctival autograft with autologous blood. Patients were seen on postoperative day 1, 1 week, 1 month, 6 months, and 1 year after surgery. Graft stability and pterygium recurrence were graded by an independent observer who was masked to the method of treatment.

    RESULTS: All 120 eyes completed the 1-year follow-up. Graft loss was seen only in the autologous blood group. Of the 62 eyes in this group, a total of 15 (24.2%) grafts dislodged. Recurrence was calculated after excluding grafts that were dislodged. Of the 105 patients, there were a total of 7 recurrences, 2 (3.4%) from the fibrin adhesive method and 5 (10.6%) from the autologous blood method. This was not statistically significant (P = 0.238).

    CONCLUSIONS: Autologous blood does not exhibit similar graft stability seen with fibrin glue. Although the recurrence rate may not be significant, careful patient selection and a standard method needs to be laid out before the use of this method is widely accepted.

    Matched MeSH terms: Pterygium/physiopathology