Displaying publications 1 - 20 of 87 in total

Abstract:
Sort:
  1. Alavi SE, Soltanian MR, Amiri IS, Khalily M, Supa'at AS, Ahmad H
    Sci Rep, 2016 Jan 27;6:19891.
    PMID: 26814621 DOI: 10.1038/srep19891
    5G communications require a multi Gb/s data transmission in its small cells. For this purpose millimeter wave (mm-wave) RF signals are the best solutions to be utilized for high speed data transmission. Generation of these high frequency RF signals is challenging in electrical domain therefore photonic generation of these signals is more studied. In this work, a photonic based simple and robust method for generating millimeter waves applicable in 5G access fronthaul is presented. Besides generating of the mm-wave signal in the 60 GHz frequency band the radio over fiber (RoF) system for transmission of orthogonal frequency division multiplexing (OFDM) with 5 GHz bandwidth is presented. For the purpose of wireless transmission for 5G application the required antenna is designed and developed. The total system performance in one small cell was studied and the error vector magnitude (EVM) of the system was evaluated.
    Matched MeSH terms: Photons
  2. Tajudin SM, Namito Y, Sanami T, Hirayama H
    Radiat Prot Dosimetry, 2020 Jul 02;188(4):486-492.
    PMID: 31950186 DOI: 10.1093/rpd/ncz308
    As a reference photon field, several radionuclides have been used frequently, such as 241Am,137Cs and60 Co for calibration. These nuclides provide mono-energy photons for dosemeters covering few tens of keV-MeV. The main energy around 200 keV is important for both environmental and medical fields since the former should consider scattering photons and the later should measure photons from X-ray generator. In our previous work, a backscattered layout can provide a uniform photon field spectra and dose rate with an energy of 190 keV by using an affordable intensity 137 Cs gamma source. Several other quasi-monoenergetic photon fields in the range of 100-200 keV could be obtained by using several available gamma sources. Two calibrated environmental CsI(Tl) survey meters, Horiba PA-1000 and Mr. Gamma A2700, had been measured with the developed backscattered photon field to understand energy-dependent features in order to confirm dosemeter readings. Consequently, both scintillator instruments are sensitive for measurements of the relatively low dose rates at 190 keV.
    Matched MeSH terms: Photons*
  3. Fulsom BG, Pedlar TK, Adachi I, Aihara H, Al Said S, Asner DM, et al.
    Phys Rev Lett, 2018 Dec 07;121(23):232001.
    PMID: 30576207 DOI: 10.1103/PhysRevLett.121.232001
    We report the observation of ϒ(2S)→γη_{b}(1S) decay based on an analysis of the inclusive photon spectrum of 24.7  fb^{-1} of e^{+}e^{-} collisions at the ϒ(2S) center-of-mass energy collected with the Belle detector at the KEKB asymmetric-energy e^{+}e^{-} collider. We measure a branching fraction of B[ϒ(2S)→γη_{b}(1S)]=(6.1_{-0.7-0.6}^{+0.6+0.9})×10^{-4} and derive an η_{b}(1S) mass of 9394.8_{-3.1-2.7}^{+2.7+4.5}  MeV/c^{2}, where the uncertainties are statistical and systematic, respectively. The significance of our measurement is greater than 7 standard deviations, constituting the first observation of this decay mode.
    Matched MeSH terms: Photons
  4. Seong IS, Vahsen SE, Adachi I, Aihara H, Al Said S, Asner DM, et al.
    Phys Rev Lett, 2019 Jan 11;122(1):011801.
    PMID: 31012694 DOI: 10.1103/PhysRevLett.122.011801
    We report on the first Belle search for a light CP-odd Higgs boson, A^{0}, that decays into low mass dark matter, χ, in final states with a single photon and missing energy. We search for events produced via the dipion transition ϒ(2S)→ϒ(1S)π^{+}π^{-}, followed by the on-shell process ϒ(1S)→γA^{0} with A^{0}→χχ, or by the off-shell process ϒ(1S)→γχχ. Utilizing a data sample of 157.3×10^{6} ϒ(2S) decays, we find no evidence for a signal. We set limits on the branching fractions of such processes in the mass ranges M_{A^{0}}<8.97  GeV/c^{2} and M_{χ}<4.44  GeV/c^{2}. We then use the limits on the off-shell process to set competitive limits on WIMP-nucleon scattering in the WIMP mass range below 5  GeV/c^{2}.
    Matched MeSH terms: Photons
  5. Kamaruddin S, Shaari JS, Kolenderski P
    Sci Rep, 2020 Apr 03;10(1):5847.
    PMID: 32246055 DOI: 10.1038/s41598-020-62812-3
    We consider the counterfactual protocol proposed in Phys. Rev. Lett., 103, 230501 (2009) within a device independent framework and show how its security can easily be compromised. Capitalising on the fact that the protocol is based on the use of a single photon entanglement phenomenon, we propose an equivalent protocol. It can be made secure within such a pessimistic framework against a supra-quantum Eve limited only by the no-signalling principle. The equivalence the protocol demonstrates the possibility of device independent framework for counterfactual quantum cryptography.
    Matched MeSH terms: Photons
  6. Sirunyan AM, Tumasyan A, Adam W, Ambrogi F, Asilar E, Bergauer T, et al.
    Eur Phys J C Part Fields, 2019;79(11):969.
    PMID: 31886778 DOI: 10.1140/epjc/s10052-019-7451-7
    Measurements are presented of the triple-differential cross section for inclusive isolated-photon+jet events in

    p
    p

    collisions at


    s

    =
    8

    TeV as a function of photon transverse momentum (

    p

    T


    γ




    ), photon pseudorapidity (

    η

    γ




    ), and jet pseudorapidity (

    η
    jet

    ). The data correspond to an integrated luminosity of

    19.7



    fb

    -
    1




    that probe a broad range of the available phase space, for


    |


    η

    γ





    |
    <
    1.44


    and


    1.57
    <
    |


    η

    γ





    |
    <
    2.50


    ,


    |


    η
    jet


    |
    <
    2.5


    ,

    40
    <

    p

    T


    γ




    <
    1000




    GeV

    , and jet transverse momentum,

    p

    T

    jet

    , > 25


    GeV

    . The measurements are compared to next-to-leading order perturbative quantum chromodynamics calculations, which reproduce the data within uncertainties.
    Matched MeSH terms: Photons
  7. Wahabi JM, Ung NM, Mahdiraji GA, Wong JHD
    Radiat Prot Dosimetry, 2024 Mar 02;200(3):264-273.
    PMID: 38123475 DOI: 10.1093/rpd/ncad303
    The radioluminescent (RL) dosemeter is excellent for real-time radiation measurement and can be used in various applications. A plastic scintillator is often the choice sensor because of its size and tissue equivalency. This study aims to characterise a novel plastic scintillator irradiated with high-energy photon beams. An RL dosimetry system was developed using the plastic scintillator. The RL dosimetry system was irradiated using a linear accelerator to characterise the dose linearity, dose rate, energy dependency and depth dose. The developed system showed a linear response toward the dose and dose rate. An energy dependency factor of 1.06 was observed. Depth dose measurement showed a mean deviation of 1.21% from the treatment planning system. The response and characteristics of the plastic scintillator show that it may be used as an alternative in an RL dosimetry system.
    Matched MeSH terms: Photons
  8. Begum M, Rahman AKMM, Abdul-Rashid HA, Yusoff Z, Mat Nawi SN, Khandaker MU, et al.
    Appl Radiat Isot, 2021 Aug;174:109771.
    PMID: 34048992 DOI: 10.1016/j.apradiso.2021.109771
    Present study concerns the key thermoluminescence (TL) properties of photonic crystal fibres (PCFs), seeking development of alternatively structured TL materials that are able to offer a advantages over existing passive dosimeters. In terms of their internal structure and light guiding properties the PCFs, collapsed and structured, differ significantly from that of conventional optical fibres. To investigate the dosimetric parameters of the PCFs use was made of a linear accelerator producing a 6 MV photon beam, delivering doses ranging from 0.5 Gy to 8 Gy. The parameters studied included TL response, linearity index, glow curves, relative sensitivity and TL signal fading, the results being compared against those obtained using TLD-100 chips. At 4 Gy photon dose the Ge-doped collapsed PCFs were found to provide a response 27 × that of structured PCF, also giving a TL yield similar to that of standard TLD-100 chips. Over post-irradiation periods of 15 and 30 days collapsed PCF TL signal fading were 8% and 17% respectively, with corresponding values of 37% and 64% for the structured PCF. Trapping parameters including the order of kinetics (b), activation energy (E) and frequency factor (s-1) were assessed with Chen's peak shape method. Lifetime of trapping centre was found to be (2.36 E+03) s and (9.03 E +01) s regarding the collapsed and structured PCF respectively with 6 Gy of photon beam. For the Ge-doped collapsed PCF, the high TL yield, sensitivity and low fading provide the basis of a highly promising system of TLD for radiotherapy applications.
    Matched MeSH terms: Photons*
  9. Aminordin Sabri AH, Mohamad Tajudin S, Abdul Aziz MZ, Furuta T
    Radiol Phys Technol, 2023 Mar;16(1):109-117.
    PMID: 36729272 DOI: 10.1007/s12194-023-00703-8
    In a brachytherapy room irradiated with an Iridium-192 (192Ir) source, the spatial distributions of photon dose rates were measured and calculated for the dose distribution both inside and outside the room. The spatial distributions were measured using a thermoluminescent dosimeter (LiF-100) on the surfaces of the concrete walls and barriers of the irradiation room. The calculations were performed using the particle and heavy ion transport code system (PHITS) by considering the detailed model of the brachytherapy room and the radiation source used in the measurements. The measured and calculated doses exhibited a similar distribution pattern within and outside the brachytherapy room. To reduce the edge effect at the entrance door, the addition of a 3-mm thick lead layer on the surface of the concrete wall on the left doorstop is recommended. For the 60Co source, with the existing walls and lead door thickness, the dose at the control console and in front of the entrance maze increased by a factor of approximately 60.
    Matched MeSH terms: Photons/therapeutic use
  10. Samson DO, Aziz MZA, Shukri A, Mat Jafri MZ, Hashim R, Zuber SH, et al.
    Health Phys, 2023 Aug 01;125(2):77-91.
    PMID: 36826380 DOI: 10.1097/HP.0000000000001688
    The current study was undertaken to investigate the radiological and dosimetric parameters of natural product-based composite (SPI/NaOH/IA-PAE/ Rhizophora spp .) phantoms. The radiological properties of the phantoms were measured at different gamma energies from Compton scatter of photons through angles of 0, 30, 45, 60, 75, and 90 degrees. Ionization chamber (IC) and Gafchromic EBT3 film dosimeters were employed to evaluate the dosimetric characteristics for photons (6-10 MV) and electrons (6-15 MeV). Radiological property results of the composite phantoms were consistent with good quality compared to those of solid water phantoms and theoretical values of water. Photon beam quality index of the SPI15 phantom with p-values of 0.071 and 0.073 exhibited insignificant changes. In addition, good agreement was found between PDD curves measured with IC and Gafchromic EBT3 film for both photons and electrons. The computed therapeutic and half-value depth ranges matched within the limits and are similar to those of water and solid water phantoms. Therefore, the radiological and dosimetric parameters of the studied composite phantom permit its use in the selection of convenient tissue- and water-equivalent phantom material for medical applications.
    Matched MeSH terms: Photons*
  11. Sahini MH, Hossain I, Wagiran H, Saeed MA, Ali H
    Appl Radiat Isot, 2014 Sep;92:18-21.
    PMID: 24973463 DOI: 10.1016/j.apradiso.2014.05.024
    Characteristics of the thermoluminescence (TL) responses of Yb- and Yb-Tb-doped optical fibers irradiated with 6MV photons are reported. The concentration of Yb in the Yb-doped optical fiber was 0.26mol%; the concentrations of Yb and Tb in the Yb-Tb-doped optical fiber were 0.62 and 0.2mol%, respectively. The TL dose responses are linear in the dose range 0.5-4Gy. The radiation sensitivity of the Yb-Tb material is almost two orders of magnitude higher than the sensitivity of the material doped with Yb alone.
    Matched MeSH terms: Photons
  12. Bugge AN, Sauge S, Ghazali AM, Skaar J, Lydersen L, Makarov V
    Phys Rev Lett, 2014 Feb 21;112(7):070503.
    PMID: 24579579
    We propose a class of attacks on quantum key distribution (QKD) systems where an eavesdropper actively engineers new loopholes by using damaging laser illumination to permanently change properties of system components. This can turn a perfect QKD system into a completely insecure system. A proof-of-principle experiment performed on an avalanche photodiode-based detector shows that laser damage can be used to create loopholes. After ∼1  W illumination, the detectors' dark count rate reduces 2-5 times, permanently improving single-photon counting performance. After ∼1.5  W, the detectors switch permanently into the linear photodetection mode and become completely insecure for QKD applications.
    Matched MeSH terms: Photons
  13. Mohd Nasir MN, Yusoff Z, Al-Mansoori MH, Abdul Rashid HA, Choudhury PK
    Opt Express, 2009 Jul 20;17(15):12829-34.
    PMID: 19654689
    A widely tunable low stimulated Brillouin scattering (SBS) photonic crystal fiber (PCF) based multi-wavelength Brillouin-erbium fiber laser is presented. The fiber laser structure utilizes a pre-amplified Brillouin pump (BP) technique with 100 m of PCF and a tunable band-pass filter within a Fabry-Perot cavity. A total of 14 Brillouin Stokes lines can be tuned over 29 nm from 1540 nm to 1569 nm. The wide tunability was only limited by the bandwidth of the tunable band-pass filter. A constant channel spacing of 0.079 nm and signal to noise ratio (SNR) of more than 20 dB for each Brillouin Stokes lines were also observed.
    Matched MeSH terms: Photons
  14. Abdul Sani SF, Othman MHU, Alqahtani A, Almugren KS, Alkallas FH, Bradley DA
    PLoS One, 2020;15(12):e0241550.
    PMID: 33378398 DOI: 10.1371/journal.pone.0241550
    For x- and gamma- irradiations delivering entrance doses from 2- up to 1000 Gy to commercial 1.0 mm thick borosilicate glass microscope slides, study has been made of their thermoluminescence yield. With an effective atomic number of 10.6 (approximating bone equivalence), photon energy dependency is apparent in the low x-ray energy range, with interplay between the photoelectric effect and attenuation. As an example, over the examined dose range, at 120 kVp the photon sensitivity has been found to be some 5× that of 60Co gamma irradiations, also with repeatability to within ~1%. The glow-curves, taking the form of a single prominent broad peak, have been deconvolved yielding at best fit a total of five peaks, the associated activation energies and frequency factors also being obtained. The results indicate borosilicate glass slides to offer promising performance as a low-cost passive radiation dosimeter, with utility for both radiotherapy and industrial applications.
    Matched MeSH terms: Photons
  15. Mondal AK, Mohamed MA, Ping LK, Mohamad Taib MF, Samat MH, Mohammad Haniff MAS, et al.
    Materials (Basel), 2021 Jan 28;14(3).
    PMID: 33525586 DOI: 10.3390/ma14030604
    Gallium oxide (Ga2O3) is a promising wide-band-gap semiconductor material for UV optical detectors and high-power transistor applications. The fabrication of p-type Ga2O3 is a key problem that hinders its potential for realistic power applications. In this paper, pure α-Ga2O3 and Ca-doped α-Ga2O3 band structure, the density of states, charge density distribution, and optical properties were determined by a first-principles generalized gradient approximation plane-wave pseudopotential method based on density functional theory. It was found that calcium (Ca) doping decreases the bandgap by introducing deep acceptor energy levels as the intermediate band above the valence band maximum. This intermediate valence band mainly consists of Ca 3p and O 2p orbitals and is adequately high in energy to provide an opportunity for p-type conductivity. Moreover, Ca doping enhances the absorptivity and reflectivity become low in the visible region. Aside, transparency decreases compared to the pure material. The optical properties were studied and clarified by electrons-photons interband transitions along with the complex dielectric function's imaginary function.
    Matched MeSH terms: Photons
  16. Ma C, Yin P, Khan K, Tareen AK, Huang R, Du J, et al.
    Small, 2021 Jan 27.
    PMID: 33502109 DOI: 10.1002/smll.202006891
    In this paper, 2D borophene is synthesized through a liquid-phase exfoliation. The morphology and structure of as-prepared borophene are systemically analyzed, and the Z-scan is used to measure the nonlinear optical properties. It is found that the saturable absorber (SA) properties of borophene make it serve as an excellent broadband optical switch, which is strongly used for mode-locking in near- and mid-infrared laser systems. Ultrastable pulses with durations as short as 792 and 693 fs are successfully delivered at the central wavelengths of 1063 and 1560 nm, respectively. Furthermore, stable pulses at a wavelength of 1878 nm are demonstrated from a thulium mode-locked fiber laser based on the same borophene SA. This research reveals a significant potential for borophene used in lasers helping extending the frontiers of photonic technologies.
    Matched MeSH terms: Photons
  17. Reduan Abdullah, Ahmad Zakaria, Nur Iziana Mohsin, Nik Ruzman Nik Idris, Ahmad Lutfi Yusof, Mazurawati Mohamed
    MyJurnal
    The fi rst part of this study was about measurement of dosimetric parameters for small photon beams to be used as input
    data for treatment planning computer system (TPS) and to verify the dose calculated by TPS in Stereotactic Radiosurgery
    (SRS) procedure. The beam data required were percentage depth dose (PDD), off-axis ratio (OAR) and scattering factor.
    Small beams of 5 mm to 45 mm diameter from a circular cone collimator in SRS were used for beam data measurements.
    Measurements were made using pinpoint ionisation chamber (0.016cc). In the second part of this study, we reported
    the important of carrying out quality assurance (QA) procedures before SRS treatment which were found to infl uence the
    accuracy of dose delivery. These QA procedures consisted of measurements on the accuracy in target localization and
    treatment room laser alignment. The calculated TPS dose for treatment was verifi ed using pinpoint ionisation chamber
    and thermoluminescent detector (TLD) 100H. The deviation mean between measured and calculated dose was -3.28%.
    The measured dose obtained from pinpoint ionisation chamber is in good agreement with the calculated dose from TPS
    with deviation mean of 2.17%. In conclusion, pinpoint ionisation chamber gives a better accuracy in dose calculation
    compared to TLD 100H. The results are acceptable as recommended by International Commission on Radiation Units
    and Measurements (ICRU) Report No. 50 (1994) that dose delivered to the target volume must be within ± 5% error.
    Matched MeSH terms: Photons
  18. Pornsuwancharoen N, Youplao P, Amiri IS, Aziz MS, Tran QL, Ali J, et al.
    Microsc Res Tech, 2018 Aug;81(8):872-877.
    PMID: 29737596 DOI: 10.1002/jemt.23049
    A conventional Michelson interferometer is modified and used to form the various types of interferometers. The basic system consists of a conventional Michelson interferometer with silicon-graphene-gold embedded between layers on the ports. When light from the monochromatic source is input into the system via the input port (silicon waveguide), the change in optical path difference (OPD) of light traveling in the stacked layers introduces the change in the optical phase, which affects to the electron mean free path within the gold layer, induces the change in the overall electron mobility can be seen by the interferometer output visibility. Further plasmonic waves are introduced on the graphene thin film and the electron mobility occurred within the gold layer, in which the light-electron energy conversion in terms of the electron mobility can be observed, the gold layer length is 100 nm. The measurement resolution in terms of the OPD of

    50 nm is achieved. In applications, the outputs of the drop port device of the modified Michelson interferometer can be arranged by the different detectors, where the polarized light outputs, the photon outputs, the electron spin outputs can be obtained by the interference fringe visibility, mobility visibility and the spin up-down splitting output energies. The modified Michelson interferometer theory and the detection schemes are given in details.
    Matched MeSH terms: Photons
  19. Liu H, Yang H, Qiao X, Wang Y, Liu X, Lee YS, et al.
    Sensors (Basel), 2017 Jul 27;17(8).
    PMID: 28749437 DOI: 10.3390/s17081725
    We have experimentally demonstrated an optical fiber Mach-Zehnder interferometer (MZI) structure formed by a few-mode photonic crystal fiber (PCF) for curvature measurement and inscribed a fiber Bragg grating (FBG) in the PCF for the purpose of simultaneously measuring temperature. The structure consists of a PCF sandwiched between two multi-mode fibers (MMFs). Bending experimental results show that the proposed sensor has a sensitivity of -1.03 nm/m-1at a curvature range from 10 m-1to 22.4 m-1, and the curvature sensitivity of the embedded FBG was -0.003 nm/m-1. Temperature response experimental results showed that the MZI's wavelength, λa, has a sensitivity of 60.3 pm/°C, and the FBG's Bragg wavelength, λb, has sensitivity of 9.2 pm/°C in the temperature range of 8 to 100 °C. As such, it can be used for simultaneous measurement of curvature and temperature over ranges of 10 m-1to 22.4 m-1and 8 °C to 100 °C, respectively. The results show that the embedded FBG can be a good indicator to compensate the varying ambient temperature during a curvature measurement.
    Matched MeSH terms: Photons
  20. Mohd Fahmi Mohd Yusof, Nur Amirah Nabila Ramli, Mohd Fahrizuan Md Yusop, Reduan Abdullah
    MyJurnal
    This study evaluates the ImageJ software as dosimetric tools for analyzing the film dosimeter in high energy photons and electrons. The percentage depth dose of photons of 6 and 10 MV and electrons of 6 and 9 MeV were measured using the Gafchromic EBT2 film dosimeter. The films were scanned and analyzed using the Verisoft software and ImageJ. The beam profiles at nominal photon and electron beam parameters were also evaluated using the two methods. The PDD measured in ImageJ at high energy photons were in good agreement within 1% percentage of discrepancy at all depths in comparison to the Verisoft software. The PDD measured in ImageJ at high energy electrons also showed good agreement to Verisoft software within 8% percentage of discrepancy at all depths. The measured flatness of beam profiles at Dmax, R50, R80 and R90 in ImageJ were also in good agreement to Verisoft software with flatness value between 4 and 8%. The results indicated the suitability of ImageJ software as dosimetric tool for analyzing EBT2 film dosimeter at high energy photon and electrons.
    Matched MeSH terms: Photons
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links