Displaying publications 1 - 20 of 119 in total

Abstract:
Sort:
  1. Noriah Jamal, Ng, Kwan-Hoong, McLean, Donald
    MyJurnal
    The objective of this study is to compare low-contrast detectability of computed radiography (CR) and screen/film (SF) mammography systems. The Nijimegen contrast detail test object (CDMAM type 3.4) was imaged at 28 kV, in automatic exposure control mode separately. Six medical imaging physicists read each CDMAM phantom image. Contrast detail curves were plotted to compare lowcontrast detectability of CR (soft copy and hard copy) and SF mammography systems. Effect of varying exposure parameters, namely kV, object position inside the breast phantom, and entrance surface exposure (ESE) on the contrast detail curve were also investigated using soft copy CR. The significance of the difference in contrast between CR and SF, and for each exposure parameter, was tested using non-parametric Kruskal-Wallis test. The low- contrast detectability of the CR (soft copy and hard copy) system was found to be not significantly different to that of the SF system (p>0.05, Kruskal-Wallis test). For CR soft copy, no significant relationship (p>0.05, Kruskal-Wallis test) was seen for variation of kV, object position inside the breast phantom and ESE. This indicates that CR is comparable with SF for useful detection and visualization of low-contrast objects such as small lowcontrast areas corresponding to breast pathology.
    Matched MeSH terms: Phantoms, Imaging
  2. Anam C, Naufal A, Sutanto H, Arifin Z, Hidayanto E, Tan LK, et al.
    Biomed Phys Eng Express, 2023 May 30;9(4).
    PMID: 37216929 DOI: 10.1088/2057-1976/acd785
    Objective. To develop an algorithm to measure slice thickness running on three types of Catphan phantoms with the ability to adapt to any misalignment and rotation of the phantoms.Method. Images of Catphan 500, 504, and 604 phantoms were examined. In addition, images with various slice thicknesses ranging from 1.5 to 10.0 mm, distance to the iso-center and phantom rotations were also examined. The automatic slice thickness algorithm was carried out by processing only objects within a circle having a diameter of half the diameter of the phantom. A segmentation was performed within an inner circle with dynamic thresholds to produce binary images with wire and bead objects within it. Region properties were used to distinguish wire ramps and bead objects. At each identified wire ramp, the angle was detected using the Hough transform. Profile lines were then placed on each ramp based on the centroid coordinates and detected angles, and the full-width at half maximum (FWHM) was determined for the average profile. The slice thickness was obtained by multiplying the FWHM by the tangent of the ramp angle (23°).Results. Automatic measurements work well and have only a small difference (<0.5 mm) from manual measurements. For slice thickness variation, automatic measurement successfully performs segmentation and correctly locates the profile line on all wire ramps. The results show measured slice thicknesses that are close (<3 mm) to the nominal thickness at thin slices, but slightly deviated for thicker slices. There is a strong correlation (R2= 0.873) between automatic and manual measurements. Testing the algorithm at various distances from the iso-center and phantom rotation angle also produced accurate results.Conclusion. An automated algorithm for measuring slice thickness on three types of Catphan CT phantom images has been developed. The algorithm works well on various thicknesses, distances from the iso-center, and phantom rotations.
    Matched MeSH terms: Phantoms, Imaging
  3. Islam MT, Samsuzzaman M, Islam MT, Kibria S
    Sensors (Basel), 2018 Dec 14;18(12).
    PMID: 30558191 DOI: 10.3390/s18124427
    An experimental system for early screening of a breast tumor is presented in this article. The proposed microwave imaging (MI) system consists of a moveable array of nine improved negative-index metamaterial (MTM)-loaded ultrawideband (UWB) antenna sensor with incorporation of a corresponding SRR (split-ring resonator) and CLS (capacitively loaded strip) structure, in a circular array, the stepper motor-based array-mounting stand, the adjustable phantom hanging platform, an RF switching system to control the receivers, and a personal computer-based signal processing and image reconstruction unit using MATLAB. The improved antenna comprises of four-unit cells along one axis, where an individual unit cell integrates a balancing SRR and CLS pair, which makes the antenna radiation omnidirectional over the operating frequencies. The electrical dimensions of this proposed antenna are 0.28λ × 0.20λ × 0.016λ, measured at the lowest operating frequency of 2.97 GHz as the operating bandwidth of this is in between 2.97⁻15 GHz (134.82% bandwidth), with stable directional radiation pattern. SP8T 8 port switch is used to enable the eight receiver antennas to sequentially send a 3⁻8.0 GHz microwave signal to capture the backscattered signal by MATLAB software. A low-cost realistic homogeneous breast phantom with tumor material is developed and measured to test the capability of the imaging system to detect the breast tumors. A post-processing delay-multiply-and-sum (DMAS) algorithm is used to process the recorded backscatter signal to get an image of the breast phantom, and to accurately identify the existence and located area of multiple breast tumor tissues.
    Matched MeSH terms: Phantoms, Imaging*
  4. Islam MS, Islam MT, Almutairi AF
    Sci Rep, 2021 11 10;11(1):22015.
    PMID: 34759284 DOI: 10.1038/s41598-021-01486-x
    This paper presents the preparation and measurement of tissue-mimicking head phantom and its validation with the iteratively corrected coherence factor delay-multiply-and-sum (IC-CF-DMAS) algorithm for brain stroke detection. The phantom elements are fabricated by using different chemical mixtures that imitate the electrical properties of real head tissues (CSF, dura, gray matter, white matter, and blood/stroke) over the frequency band of 1-4 GHz. The electrical properties are measured using the open-ended dielectric coaxial probe connected to a vector network analyzer. Individual phantom elements are placed step by step in a three-dimensional skull. The IC-CF-DMAS image reconstruction algorithm is later applied to the phantom to evaluate the effectiveness of detecting stroke. The phantom elements are preserved and measured multiple times in a week to validate the overall performance over time. The electrical properties of the developed phantom emulate the similar properties of real head tissue. Moreover, the system can also effectively detect the stroke from the developed phantom. The experimental results demonstrate that the developed tissue-mimicking head phantom is time-stable, and it shows a good agreement with the theoretical results in detecting and reconstructing the stroke images that could be used in investigating as a supplement to the real head tissue.
    Matched MeSH terms: Phantoms, Imaging*
  5. Hairenanorashikin Sharip, Rafidah Supar
    MyJurnal
    This experimental study investigated the significant different in image quality and dose between different
    automatic exposure of exposure parameter (AOP) mode in full field digital mammography (FFDM) system.
    CIRS012A and PMMA breast phantom (4cm, 5cm and 6 cm thickness) were used as subject using
    Senographe Essential FFDM system. TLD chip was used as dose measurement tool. Exposures were taken
    in cranio-caudal projection. 2 radiographers with more than 10 years of working experience in performing
    mammography scored the image independently. Kappa finds a good agreement between raters (kappa
    value=0.9, p0.05). DOSE mode is the preferred selection in optimizing between dose and image quality.
    Matched MeSH terms: Phantoms, Imaging
  6. Marashdeh MW, Bauk S, Tajuddin AA, Hashim R
    Appl Radiat Isot, 2012 Apr;70(4):656-62.
    PMID: 22304963 DOI: 10.1016/j.apradiso.2012.01.008
    The mass attenuation coefficients of Rhizophora spp. binderless particleboard with four different particle sizes (samples A, B, C and D) and natural raw Rhizophora spp. wood (sample E) were determined using single-beam photon transmission in the energy range between 16.59 and 25.26 keV. This was done by determining the attenuation of K(α1) X-ray fluorescent (XRF) photons from niobium, molybdenum, palladium, silver and tin targets. The results were compared with theoretical values of young-age breast (Breast 1) and water calculated using a XCOM computer program. It was found that the mass attenuation coefficient of Rhizophora spp. binderless particleboards to be close to the calculated XCOM values in water than natural Rhizophora spp. wood. Computed tomography (CT) scans were then used to determine the density profile of the samples. The CT scan results showed that the Rhizophora spp. binderless particleboard has uniform density compared to natural Rhizophora spp. wood. In general, the differences in the variability of the profile density decrease as the particle size of the pellet samples decreases.
    Matched MeSH terms: Phantoms, Imaging/standards*
  7. Banjade DP, Ng BS, Zakir M, Tajuddin AA, Shukri A
    Br J Radiol, 2002 Oct;75(898):812-8.
    PMID: 12381690
    A study of dose mapping techniques to investigate the dose distribution throughout a planned target volume (PTV) in a humanoid breast phantom exposed to a 6 MV photon beam similar to that of treatment conditions is described. For tangential breast irradiation using a 6 MV accelerator beam, the dose is mapped at various locations within the PTV using thermoluminescent dosemeters (TLDs) and radiographic films. An average size perspex breast phantom with the ability to hold the dosemeters was made. TLDs were exposed after packing them in various locations in a particular slice, as planned by the treatment planning system (TPS). To map the dose relative to the isocenter, films were exposed after tightly packing them in between phantom slices, parallel to the central axis of the beam. The dose received at every location was compared with the given dose as generated by the TPS. The mapped dose in each location in the isocentric slice from superficial to deep region was found to be in close agreement with the TPS generated dose to within +/-2%. Doses at greater depths and distant medial and lateral ends, however, were found to be lower by as much as 9.4% at some points. The mapped dose towards the superior region and closest inferior region from the isocenter was found to agree with those for TPS. Conversely, results for the farthest inferior region were found to be significantly different with a variance as much as 17.4% at some points, which is believed to be owing to the variation in size and shape of the contour. Results obtained from films confirmed this, showing similar trends in dose mapping. Considering the importance of accurate doses in radiotherapy, evaluating dose distribution using this technique and tool was found to be useful. This provides the opportunity to choose a technique and plan to provide optimum dose delivery for radiotherapy to the breast.
    Matched MeSH terms: Phantoms, Imaging*
  8. Banjade DP, Tajuddin AA, Shukri A
    Appl Radiat Isot, 2001 Sep;55(3):297-302.
    PMID: 11515650
    Previous scattering and depth-dose investigations involving use of the Malaysian hardwood Rhizophora spp have shown this medium to produce good agreement with measurements made in water. Present study extends the comparison, now including measurements of percentage depth-dose made for photons at 6MV and 5 and 12MeV electron beams. For the 6 MV photon and 5 MeV electron beams, discrepancies between percentage depth-dose for Rhizophora spp and water, at all depths, are found to be within 2.6 and 2.4% respectively. At 12 MeV electron energies, measured percentage depth-doses in Rhizophora spp beyond 3.5cm depth are found to be in significant discord with those for water. The absorbed dose in water measured in Rhizophora spp at d(max) for all three beams produces discrepancies of no more than 1.1% when compared with measurements made in water.
    Matched MeSH terms: Phantoms, Imaging*
  9. Moey, Soo-Foon, Nur Farah Hani Muhd Jaafar, Nursyahirah Saidin
    MyJurnal
    Introduction: Various medium and high tube potentials were utilized to conduct chest x-rays. There
    are advantages and disadvantages with regards to image quality and radiation dose when using
    medium and high kilovoltage (kVp) technique. However, radiographers have misconstrued
    understanding pertaining to the choice of tube potential as well as grid usage when performing chest radiography. Methods: The experimental study was conducted using the PBU-50 phantom by exposing it with medium kVp utilizing grid and non-grid as well as high kVp with grid. All images obtained were evaluated using the modified evaluation criteria for PA chest established by the Commission of European Communities, 1996 whilst the dose area product (DAP) was determined using the Dose Area Product (DAP) meter. The value obtained from the DAP meter was converted to entrance surface dose (ESD) usingCALDOSE_X5.0 software and mathematical formula. Results: The Wilcoxon Signed-Rank Test indicated a significant difference in ESD when using medium and high kVp; Z= -2.666, p
    Matched MeSH terms: Phantoms, Imaging
  10. Siti Nur Masturah Abdul Malek, Sayed Inayatullah Shah
    MyJurnal
    In ultrasound imaging there is compromise between the penetration of signal at certain depths into the object and image resolution as the ultrasound probe only can transmit single frequency signals in one transmission. Using curvilinear ultrasound probe with 2 to 5 MHz frequency bandwidth, this study investigated the use of multi-frequency imaging to enhance the quality of phantom images.
    Methods: Siemen Acuson X150 with curvilinear ultrasound transducer was used to scan the organs of interest (kidney, gallbladder and pancreas) of the ultrasound abdominal phantom. Different images at the different selected frequencies (2.5, 3.6 and 5.0 MHz) were created by fixing the position and the orientation of the transducer in each of the scanning process. Different-frequency images were generated and combined to produce composite (multi-frequency) image. Results: In this study, the quality of the composite image was evaluated based on signal-to noise ratio (SNR) and the obtained results were compared with the single frequency images. Besides, the comparison was also made in terms of overall image quality (noise and sharpness of organ outline) through perceived image quality analysis. Based on calculated SNR, the composite image of the kidney, gallbladder and pancreas recorded higher SNR value as compared to the single frequency images. However, through perceived image quality, most of the observers viewed that the quality of the composite image of the kidney, gallbladder and pancreas is poor as compared to the single frequency image. Conclusions: Image quality of ultrasound imaging is improved by combining multiple ultrasound frequency images into a single composite image. This is achieved as high SNR is obtained in the composite image. However, through perceived image quality, the overall image quality of the composite image was poor.
    Matched MeSH terms: Phantoms, Imaging
  11. Husaini Salleh, Supian Samat, Mohd Khalid Matori, Muhammad Jamal Md Isa, Mohd Ramli Arshad, Shahrul Azlan Azizan, et al.
    MyJurnal
    Heel Effect is the well known phenomena in x-ray production. It contributes the effect to image
    formation and as well as scattered radiation. But there is paucity in the study related to heel effect.
    This study is for mapping and profiling the dose on the surface of water phantom by using mobile
    C-arm unit Toshiba SXT-1000A. Based on the result the dose profile is increasing up to at least
    about 57% from anode to cathode bound of the irradiated area. This result and information can be
    used as a guide to manipulate this phenomenon for better image quality and radiation safety for
    this specific and dedicated fluoroscopy unit.
    Matched MeSH terms: Phantoms, Imaging
  12. Chelliah, Kanaga Kumari, Ang, Wee Chin, Abd Aziz Tajuddin, Arasaratnam, Shantini A., Suraya Aziz, Laila Suryani Elias
    MyJurnal
    Digital mammography has been progressively introduced in screening centers and the concern is to achieve an image of diagnostic value which would be able to detect early changes in the breast tissue. The aim of this study was to evaluate the image quality of mammograms using quantitative and qualitative methods of two FFDM systems with variations in breast thickness and anode/filter combination. This study was done from January to April 2008 with two FFDM systems; Siemens Mammomat NovationDR at Diagnostic Imaging Department, Hospital Kuala Lumpur and Hologic Lorad Selenia at Breast Clinic, National Cancer Society. A CIRS012A tissue equivalent breast phantom (4, 5 and 6 cm) thickness was used to obtain images in the craniocaudal plane with 26-32 kVp and a combination of molybdenum/molybdenum (Mo/Mo) and molybdenum/rhodium (Mo/Rh) anode/filter. For the qualitative evaluation, two independent radiologist with a minimum of five years experience was used to score the images. Wilcoxon Sign Rank Test showed that there are no significant differences (p > 0.05) in image quality between both the FFDM systems. Kappa analysis had a poor agreement between the scores given by the two radiologists. The quantitative analysis using Mann-Whitney test showed that there are significant differences (p < 0.05) between the SNR values of both FFDM systems. Although the qualitative evaluation was similar, the study showed that Lorad Selenia had a significantly superior SNR value, hence would be a better tool to detect early changes in the breast tissue. This study also demonstrated that a lower kVp is more suitable with molybdenum filter and as the breast thickness is increased rhodium filter with higher kVp displayed better quality images.
    Matched MeSH terms: Phantoms, Imaging
  13. Rosli Darmawan
    MyJurnal
    The study on the possibility of using DMU Kinematics module in CAE tools for dose exposure work planning was carried out. A case scenario was created using 3D CAD software and transferred to DMU Kinematics module in a CAE software. The work plan created using DMU Kinematics module was animated to simulate a real time scenario. Data on the phantom position against the radioactive source was collected by activating positioning sensors in the module. The data collected was used to calculate the estimated dose rate exposure for the phantom. The results can be used to plan the safest and optimum procedures in carrying out the radiation related task.
    Matched MeSH terms: Phantoms, Imaging
  14. Langarizadeh, Mostafa, Rozi Mahmud, Abd. Rahman Ramli, Suhaimi Napis, Mohammad Reza Beikzadeh, Wan Eny Zarina Wan Abdul Rahman
    MyJurnal
    Breast cancer is one of the most important diseases among females. According to the Malaysian Oncological Society (Wahid, 2007), about 4% of women who are 40 years old and above are suffering from breast cancer. Masses and microcalcifications are two important signs for breast cancer diagnosis on mammography. In this research, the effects of different image processing techniques which include enhancement, restoration, segmentation, and hybrid methods on phantom images were studied. Three different phantom images, which were obtained at 25kv (63.2 MAS), 28kv (29.8 MAS) and 35kv (9.5 MAS), were manipulated using image processing methods. The images were scored by two expert radiologists and the results were compared to explore any significant improvements. Meanwhile, the Wilcoxen Rank test was used to compare the quality of the manipulated images with the original one (alpha=0.05). Each image processing method was found to be effective on some particular criteria for image quality. Some methods were effective on just one criterion while some others were effective on a few criteria. The statistical test showed that there was an average improvement of 41 percent when the images were manipulated using the histogram modification methods. It could be concluded that different image processing methods have different effects on phantom images which generally improve radiologists’ visualization. The results confirm that the histogram stretching and histogram equation methods lead to higher improvement in image quality as compared to the original image (p < 0.05).
    Matched MeSH terms: Phantoms, Imaging
  15. Islam MT, Samsuzzaman M, Islam MT, Kibria S, Singh MJ
    Sensors (Basel), 2018 Sep 05;18(9).
    PMID: 30189684 DOI: 10.3390/s18092962
    Microwave breast imaging has been reported as having the most potential to become an alternative or additional tool to the existing X-ray mammography technique for detecting breast tumors. Microwave antenna sensor performance plays a significant role in microwave imaging system applications because the image quality is mostly affected by the microwave antenna sensor array properties like the number of antenna sensors in the array and the size of the antenna sensors. In this paper, a new system for successful early detection of a breast tumor using a balanced slotted antipodal Vivaldi Antenna (BSAVA) sensor is presented. The designed antenna sensor has an overall dimension of 0.401λ × 0.401λ × 0.016λ at the first resonant frequency and operates between 3.01 to 11 GHz under 10 dB. The radiating fins are modified by etching three slots on both fins which increases the operating bandwidth, directionality of radiation pattern, gain and efficiency. The antenna sensor performance of both the frequency domain and time domain scenarios and high-fidelity factor with NFD is also investigated. The antenna sensor can send and receive short electromagnetic pulses in the near field with low loss, little distortion and highly directionality. A realistic homogenous breast phantom is fabricated, and a breast phantom measurement system is developed where a two antennas sensor is placed on the breast model rotated by a mechanical scanner. The tumor response was investigated by analyzing the backscattering signals and successful image construction proves that the proposed microwave antenna sensor can be a suitable candidate for a high-resolution microwave breast imaging system.
    Matched MeSH terms: Phantoms, Imaging
  16. Ullah MA, Islam MT, Alam T, Ashraf FB
    Sensors (Basel), 2018 Dec 01;18(12).
    PMID: 30513719 DOI: 10.3390/s18124214
    This paper demonstrates the performance of a potential design of a paper substrate-based flexible antenna for intrabody telemedicine systems in the 2.4 GHz industrial, scientific, and medical radio (ISM) bands. The antenna was fabricated using 0.54 mm thick flexible photo paper and 0.03 mm copper strips as radiating elements. Design and performance analyses of the antenna were performed using Computer Simulation Technology (CST) Microwave Studio software. The antenna performances were investigated based on the reflection coefficient in normal and bent conditions. The total dimensions of the proposed antenna are 40 × 35 × 0.6 mm³. The antenna operates at 2.33⁻2.53 GHz in the normal condition. More than an 8% fractional bandwidth is expressed by the antenna. Computational analysis was performed at different flexible curvatures by bending the antenna. The minimum fractional bandwidth deviation is 5.04% and the maximum is 24.97%. Moreover, it was mounted on a homogeneous phantom muscle and a four-layer human tissue phantom. Up to a 70% radiation efficiency with a 2 dB gain was achieved by the antenna. Finally, the performance of the antenna with a homogeneous phantom muscle was measured and found reliable for wearable telemedicine applications.
    Matched MeSH terms: Phantoms, Imaging
  17. Hariyanto AP, Budiarti NT, Suprijanto, Ng KH, Haryanto F, Endarko
    Phys Eng Sci Med, 2023 Sep;46(3):1175-1185.
    PMID: 37253939 DOI: 10.1007/s13246-023-01283-y
    TMP is gradually becoming a fundamental element for quality assurance and control in ionizing and non-ionizing radiation imaging modalities as well as in the development of different techniques. This study aimed to evaluate and obtain polyvinyl chloride tissue mimicking material for dual-modality breast phantoms in mammography and ultrasound. Breast tissue equivalence was evaluated based on X-ray attenuation properties, speed of sound, attenuation, and acoustic impedance. There are six samples of PVC-plasticizer material with variations of PVC concentration and additives. The evaluation of X-ray attenuation was carried out using mammography from 23 to 35 kV, while the acoustic properties were assessed with mode A ultrasound and a transducer frequency of 5 MHz. A breast phantom was created from TMP material with tissue equivalence and was then evaluated using mammography as well as ultrasound to analyze its image quality. The results showed that samples A (PVC 5%, DOP 95%), B (PVC 7%, DOP 93%), C (PVC 10%, DOP 90%), E (PVC 7%, DOP 90%, graphite 3%), and F (PVC 7%, DOP 90%, silicone oil 3%) have the closest equivalent to the ACR breast phantom material with a different range of 0.01-1.39 in the 23-35 kV range. Based on the evaluation of the acoustic properties of ultrasound, A had high similarity to fat tissue with a difference of 0.03 (dB cm- 1 MHz- 1) and 0.07 (106 kg m- 2 s- 1), while B was close to the glandular tissue with a difference of 9.2 m s- 1. Multilayer breast phantom images' results showed gray levels in mammography and ultrasound modalities. Therefore, this study succeeded in establishing TMP material for mammography and ultrasound. It can also be used for simple quality assurance and control programs.
    Matched MeSH terms: Phantoms, Imaging
  18. Darmini, Prastanti AD, Daryati S, Kartikasari Y, Sulistiyadi AH, Setiawan DA
    Med J Malaysia, 2023 Dec;78(7):865-869.
    PMID: 38159919
    INTRODUCTION: There are two data acquisition methods for computed tomography (CT) scans, namely sequence and helical. Each of them has two ways of measuring the volume of bleeding in a head CT scan, namely by manual and automatic methods. So, it is necessary to have an analysis for measurement accuracy with these two methods in two data acquisitions. The purpose of this study was to compare and evaluate bleeding volumetric measurement accuracy of sequence and helical on head CT acquisition using manual and automatic methods.

    MATERIALS AND METHODS: This is quantitative research with a true experimental approach. Actual bleeding volume was simulated by an acrylic phantom containing Iodine contrast media (5 ml, 10 ml, 15 ml, and 20 ml). The phantom was scanned using routine CT protocol using the helical and sequence technique. Bleeding volume from each technique was measured manually using the Broderick formula and automatic software (ROI based). Accuracy was assessed by comparing the volume measurement result to the actual bleeding volume. Data was analysed using the Friedman test and by Wilcoxon.

    RESULTS: The standard deviation of measured bleeding volume from the manual and automatic measurements compared to the actual bleeding volume were (0.220; 0.236; 0.351; 0.057) and (0.139; 0.270; 0.315; 0.329) in helical technique, and (0.333; 0.376; 0.447; 0.476) and (0.139; 0.242; 0.288; 0,376) in sequence technique. There are differences in the measurement results from the helical and sequence techniques (p <0.05) and using manual and automatic methods (p <0.05).

    CONCLUSION: The measurement of bleeding volume that has a standard deviation value compared to the actual volume is more accurate in the helical technique using the automatic method, while the sequence technique is the manual method.

    Matched MeSH terms: Phantoms, Imaging
  19. Dolah MT, Samat SB, Kadni T
    Malays J Med Sci, 2000 Jan;7(1):47-53.
    PMID: 22844215
    Absorbed dose to water was measured with ionisation chambers NE 2561 (#267), NE 2581 (#334), NE 2571 (#1028), using the IAEA standard water phantom. The ionisation chamber was inserted in the water phantom at a reference depth dependent on the type of the radiation quality used. Three radiation qualities were used namely 1.25 MeV gamma ray, 6 MV x-rays and 10 MV x-rays. The values of the absorbed dose to water were determined by the N(K)- and N(X)- based methods, i.e with the use of IAEA, HPA, NACP, AAPM, NCRP and ICRU protocols. The aim of this study was to make an intercomparison of the results, by taking the IAEA protocol as a standard. The largest deviation contributed by any of these protocols was recorded for each quality. It was found that AAPM, NCRP and ICRU protocols contributed 0.94% for 1.25 MeV gamma ray, NACP contributed 2.12% for the 6 MV x-rays, and NACP contributed 2.35% for 10 MV x-rays. Since the acceptable limit of deviation set by the IAEA for this absorbed dose work is ± 3%, it is clear that the overall deviations obtained were all satisfactory.
    Matched MeSH terms: Phantoms, Imaging
  20. Dabbagh A, Abdullah BJ, Ramasindarum C, Abu Kasim NH
    Ultrason Imaging, 2014 Oct;36(4):291-316.
    PMID: 24626566 DOI: 10.1177/0161734614526372
    Tissue-mimicking phantoms that are currently available for routine biomedical applications may not be suitable for high-temperature experiments or calibration of thermal modalities. Therefore, design and fabrication of customized thermal phantoms with tailored properties are necessary for thermal therapy studies. A multitude of thermal phantoms have been developed in liquid, solid, and gel forms to simulate biological tissues in thermal therapy experiments. This article is an attempt to outline the various materials and techniques used to prepare thermal phantoms in the gel state. The relevant thermal, electrical, acoustic, and optical properties of these phantoms are presented in detail and the benefits and shortcomings of each type are discussed. This review could assist the researchers in the selection of appropriate phantom recipes for their in vitro study of thermal modalities and highlight the limitations of current phantom recipes that remain to be addressed in further studies.
    Matched MeSH terms: Phantoms, Imaging*