Displaying all 13 publications

Abstract:
Sort:
  1. Lau MN, Sivarajan S, Kamarudin Y, Othman SA, Wan Hassan WN, Soh EX, et al.
    J Dent Educ, 2022 Nov;86(11):1477-1487.
    PMID: 35650663 DOI: 10.1002/jdd.12954
    OBJECTIVE: This study aimed to explore students' perceptions of flipped classroom (FC) compared to live demonstration (LD) in transferring skills of fabricating orthodontic wire components for orthodontic removable appliances.

    METHODS: Forty third-year undergraduate dental students were randomly assigned to two groups: FC (n = 20) and LD (n = 20). Students in group FC attended FC, while students in group LD attended LD. Both groups underwent a series of standardized teaching sessions to acquire skills in fabricating six types of orthodontic wire components. Eight students (four high achievers and four low achievers) from each group were randomly selected to attend separate focus group discussion (FGD) sessions. Students' perceptions on the strengths, weaknesses, and suggestions for improvement on each teaching method were explored. Audio and video recordings of FGD were transcribed and thematically analyzed using NVivo version 12 software.

    RESULTS: Promoting personalized learning, improvement in teaching efficacy, inaccuracy of three-dimensional demonstration from online video, and lack of standardization among instructors and video demonstration were among the themes identified. Similarly, lack of standardization among instructors was one of the themes identified for LD, in addition to other themes such as enabling immediate clarification and vantage point affected by seating arrangement and class size.

    CONCLUSIONS: In conclusion, FC outperformed LD in fostering personalized learning and improving the efficacy of physical class time. LD was more advantageous than FC in allowing immediate question and answer. However, seating arrangement and class size affected LD in contrast to FC.

    Matched MeSH terms: Orthodontic Wires*
  2. Ahmad S, Badshah S, Ul Haq I, Abdullah Malik S, Amjad M, Nasir Tamin M
    Materials (Basel), 2019 Oct 23;12(21).
    PMID: 31652687 DOI: 10.3390/ma12213463
    Wire ropes undergo a fretting fatigue condition when subjected to axial and bending loads. The fretting behavior of wires are classified as line contact and trellis point of contact. The experimental study on the fatigue of wire ropes indicates that most of the failure occurs due to high localized stresses at trellis point of contact. A continuum damage mechanics approach was previously proposed to estimate the fatigue life estimation of wire ropes. The approach majorly depends on the high value of localized stresses as well as the micro-slippage occurs at the contact region. Finite element approach has been used to study radial and axial distribution of stresses and displacement in order to clearly understand the evolution of stresses and existence of relative displacements between neighboring wires under various loading and frictional conditions. The relative movements of contacting wires are more when friction is not considered. In the presence of friction, the relative movement occurs at the boundaries of the contact region. The location of microslip in the presence of friction is backed by the experimental observation stating the crack is initiated at or the outer boundary of the contact spot. The existence of slip is due to different displacement of outer and central wires.
    Matched MeSH terms: Orthodontic Wires
  3. Lau MN, Kamarudin Y, Zakaria NN, Sivarajan S, Mohd Tahir NNZ, Bahar AD, et al.
    PLoS One, 2021;16(7):e0254478.
    PMID: 34243187 DOI: 10.1371/journal.pone.0254478
    Flipped classroom may overcome weaknesses of live demonstration in teaching orthodontic wire-bending. This study aims to compare the effectiveness between flipped classroom and live demonstration in transferring skills for fabricating Adams clasp. Forty third-year undergraduate dental students were assigned to two groups. The students in group LD (n = 20) attended a live demonstration while students in group FC (n = 20) attended a flipped classroom. Both groups were taught on skills to fabricate Adams clasp in a standardised way. Each student from both groups were asked to submit an Adams clasp for a blinded quality assessment by two trained and calibrated assessors using a 18-item rubric, followed by validated students' satisfaction questionnaires to evaluate their perceived satisfaction on the teaching method received. A crossover study was then conducted three weeks later where LD attended a flipped classroom while FC attended a live demonstration. Students' satisfaction questionnaires were again collected from each student for blinded analysis. Mean scores for the quality of Adams clasp were 9.775 and 9.125 for LD and FC, respectively. No significant difference was detected between the two groups. Statistically significant association was found for one statement on the questionnaire, "I found the classroom arrangements conducive for the wire-bending activity" (p = 0.010). No significant differences were found between the two groups for other statements (p > 0.05). In conclusion, within the limitations of the study, flipped classroom is equally effective as conventional live demonstration in transferring orthodontic wire-bending skills for fabrication of Adams clasp. However, students perceived the classroom arrangements during the flipped classroom significantly more conducive for teaching orthodontic wire-bending.
    Matched MeSH terms: Orthodontic Wires*
  4. Hassanin Abdulkhabeer Ali Alyassiri, Anis Farhan Kamaruddin, Khoirulzariah Ismail, Noor Ayuni Ahmad Shafiai, Norma Ab Rahman, Wan Muhamad Amir W Ahmad
    MyJurnal
    Introduction: Coated archwires improve aesthetics during orthodontic treatment. However, little is known regarding
    their clinical benefit. This randomised controlled trial (RCT) compared the tooth alignment (TA), coating loss (CL),
    colour change (∆E*), and patient perception of coated archwires with their controls. Details of ∆E* and perception were reported in the second part of the articles. Methods: This RCT was done at three centres. Participants
    were randomised to receive one of four treatment interventions using 0.014” superelastic coated nickel-titanium
    archwires from Orthocare, RMO, G&H, and conventional uncoated 3M Unitek® archwires. These archwires were
    ligated during bonding and collected after eighth week and questionnaires were distributed to participants in the
    experimental groups only. After removal, TA and CL were measured using Little’s Irregularity Index and Autodesk®
    AutoCAD® software, respectively. At the time of this preliminary reporting, 84 participants had completed the trial. Two archwires fractured and were excluded. Therefore, 166 archwires (n = 166) were analysed. Results: Only
    non-extraction cases showed statistically significant differences in TA change between all groups (p = 0.005) and
    RMO showed significantly lowest mean of TA (1.5 mm). RMO and Orthocare showed significant TA change in the
    upper and lower arches (p = 0.037, 0.048). CL was found to be insignificant for both extraction and non-extraction
    cases (p >0.05). Comparison between upper and lower arches revealed no significant difference in TA and CL in all
    groups (p >0.05). Conclusion: From this preliminary analysis, Orthocare provides better TA in non-extraction cases
    despite highest percentage of coating loss.
    Matched MeSH terms: Orthodontic Wires
  5. Sivarajan S, Soh EX, Zakaria NN, Kamarudin Y, Lau MN, Bahar AD, et al.
    BMC Med Educ, 2021 Jun 07;21(1):326.
    PMID: 34098931 DOI: 10.1186/s12909-021-02717-5
    BACKGROUND: Wire-bending skills is commonly taught through live demonstrations (LD) though flipped classroom (FC) method has gained popularity. Continuous formative assessment promotes personalised learning via closely monitored progress, with the identification of students' strengths and weaknesses. This study aims to evaluate the effects of LD and FC teaching methods, supplemented with continuous formative assessment, on dental students' learning of wire-bending skills for six types of removable orthodontic appliance components. A deeper understanding of the relative effectiveness between LD and FC teaching methods can help identify the most appropriate method to achieve student learning objectives, which is especially important given the current Covid-19 pandemic.

    METHODS: Forty third-year undergraduate dental students were randomly assigned into FC (n = 20) or LD (n = 20) cohort. Each student attended six teaching sessions, each to teach students' competency in fabricating one type of wire component, for a total competency in fabricating six wire components over the course of six teaching sessions. Either LD or FC teaching methods were used. After each session, wire assignments had to be submitted. Wire assignments were then evaluated using a blinded wire-bending assessment protocol. As part of their formative assessment, the assessment results were distributed to students, lecturers, and technicians before the next session. After the first session (T0) and at the end of all six sessions (T1), students completed a self-reported questionnaire.

    RESULTS: The mean wire-bending scores for FC were significantly higher than LD for two of the six assignments, namely the Adams clasp (p 

    Matched MeSH terms: Orthodontic Wires
  6. Mathew, Thomas
    Malaysian Dental Journal, 2011;32(1):28-40.
    MyJurnal
    It is the aim of all clinicians to accomplish biological tooth movement, which implies the use of low, continuous force. Constant unrelented search for a better wire, which can deliver optimal orthodontic force, has led to the invention of a lot of orthodontic wires such as Stainless steel, Beta Titanium, Nickel Titanium and multi stranded wires. In this study, the loading and unloading properties of 0.016 inch, 0.016x0.022 inch and 0.017x0.025 inch dimensions of stainless steel, conventional NiTi, Super elastic NiTi, and TMA arch wires were determined by means of a modified three point bending test for two inter bracket widths of 5 mm and 6.5 mm for deflection of 1 to 3 mm. The applied forces dependence on cross-sectional size differs from the linear-elastic prediction in super elastic NiTi wires. The stainless steel wires had the highest force values on all the three dimensions and cross section. On loading and unloading, TMA wires had force values in-between stainless steel, conventional NiTi and super elastic NiTi. The conventional NiTi had much lower force values compared to stainless steel and TMA and were linearly progressing compared to Super elastic NiTi. On loading and unloading the super elastic NiTi had force values in the range of conventional NiTi and had constant forces on higher deflection. The studies showed that the force value was comparatively higher in 5 mm inter bracket width than the 6.5 mm inter bracket width for all the cross section and dimension of wires.
    Matched MeSH terms: Orthodontic Wires
  7. Norman NH, Worthington H, Chadwick SM
    J Orthod, 2016 Sep;43(3):176-85.
    PMID: 26836747 DOI: 10.1080/14653125.2015.1122260
    OBJECTIVE: To compare the clinical performance of nickel titanium (NiTi) versus stainless steel (SS) springs during orthodontic space closure.
    DESIGN: Two-centre parallel group randomized clinical trial.
    SETTING: Orthodontic Department University of Manchester Dental Hospital and Orthodontic Department Countess of Chester Hospital, United Kingdom.
    SUBJECTS AND METHODS: Forty orthodontic patients requiring fixed appliance treatment were enrolled, each being randomly allocated into either NiTi (n = 19) or SS groups (n = 21). Study models were constructed at the start of the space closure phase (T0) and following the completion of space closure (T1). The rate of space closure achieved for each patient was calculated by taking an average measurement from the tip of the canine to the mesiobuccal groove on the first permanent molar of each quadrant.
    RESULTS: The study was terminated early due to time constraints. Only 30 patients completed, 15 in each study group. There was no statistically significant difference between the amounts of space closed (mean difference 0.17 mm (95%CI -0.99 to 1.34; P = 0.76)). The mean rate of space closure for NiTi coil springs was 0.58 mm/4 weeks (SD 0.24) and 0.85 mm/4 weeks (SD 0.36) for the stainless steel springs. There was a statistically significant difference between the two groups (P = 0.024), in favour of the stainless steel springs, when the mean values per patient were compared.
    CONCLUSIONS: Our study shows that stainless steel springs are clinically effective; these springs produce as much space closure as their more expensive rivals, the NiTi springs.
    Matched MeSH terms: Orthodontic Wires*
  8. Razali MF, Mahmud AS, Mokhtar N
    J Mech Behav Biomed Mater, 2018 Jan;77:234-241.
    PMID: 28954242 DOI: 10.1016/j.jmbbm.2017.09.021
    NiTi arch wires are used widely in orthodontic treatment due to its superelastic and biocompatibility properties. In brackets configuration, the force released from the arch wire is influenced by the sliding resistances developed on the arch wire-bracket contact. This study investigated the evolution of the forces released by a rectangular NiTi arch wire towards possible intraoral temperature and deflection changes. A three dimensional finite element model was developed to measure the force-deflection behavior of superelastic arch wire. Finite element analysis was used to distinguish the martensite fraction and phase state of arch wire microstructure in relation to the magnitude of wire deflection. The predicted tensile and bending results from the numerical model showed a good agreement with the experimental results. As contact developed between the wire and bracket, binding influenced the force-deflection curve by changing the martensitic transformation plateau into a slope. The arch wire recovered from greater magnitude of deflection released lower force than one recovered from smaller deflection. In contrast, it was observed that the plateau slope increased from 0.66N/mm to 1.1N/mm when the temperature was increased from 26°C to 46°C.
    Matched MeSH terms: Orthodontic Wires*
  9. Ulhaq A, Esmail Z, Kamaruddin A, Meadows S, Daus J, Vitale M, et al.
    Am J Orthod Dentofacial Orthop, 2017 Dec;152(6):744-752.
    PMID: 29173854 DOI: 10.1016/j.ajodo.2017.07.014
    INTRODUCTION: The objective of this 4-arm parallel study was to evaluate the alignment efficiency and esthetic performance of 4 coated nickel-titanium archwires over an 8-week period.

    METHODS: Patients in the permanent dentition requiring maxillary and mandibular fixed orthodontic treatment with a preadjusted edgewise appliance were eligible for inclusion. Patients attending 4 hospital departments (United Kingdom and Italy) were randomly allocated to 1 of 4 treatment interventions: (1) BioCosmetic (Forestadent, Pforzheim, Germany), 0.017 in; (2) Titanol (Forestadent), 0.016 in; (3) TP Aesthetic (TP Orthodontics, La Porte, Ind), 0.014 in; and (4) Tooth Tone (Ortho Organizers, Calsbad, Calif) 0.016 in. Block randomization with block sizes of 4 and 8 was used to ensure an allocation ratio of 1:1:1:1. The primary outcome was alignment efficiency determined by the reduction in Little's irregularity index (mm). Secondary outcomes were color change using the Commission Internationale de L'Eclairage L*a*b* system and percentage of coating loss. Blinding was only applicable to outcome assessment of alignment efficiency. Regression models with Sidak's multiple comparison of means were used to analyze the data.

    RESULTS: One hundred fifty patients (300 dental arches) were allocated to the treatment interventions, including 61 male and 89 female subjects with a mean age of 16.60 years. The average duration of follow-up was 63.65 days. Baseline characteristics for the archwire groups were similar. One patient was lost to follow-up. Five percent (n = 15) of the archwires fractured: BioCosmetic, 5.3% (n = 4); Titanol, 6.8% (n = 5); TP Aesthetic, 5.3% (n = 4); and Tooth Tone, 2.7% (n = 2). We analyzed 283 dental arches for alignment efficiency. There was no statistically significant difference for mean reduction in irregularity between the archwire groups (P = 0.627): BioCosmetic (n = 71), 3.86 mm (95% CI, 3.31-4.41); Titanol (n = 69), 4.51 mm (95% CI, 4.00-5.02); TP Aesthetic (n = 71), 4.13 mm (95% CI, 3.49-4.78); and Tooth Tone (n = 72), 4.21 mm (95% CI, 3.89-4.46). There was a statistically significant difference between archwire groups for color change (P = 0.001) and percentage of coating loss (P = 0.001), with BioCosmetic performing best in both parameters.

    CONCLUSIONS: There was no difference between the archwires for alignment efficiency. BioCosmetic performed statistically significantly better than did the other groups for both color change and coating loss.

    REGISTRATION: This trial was registered with the East Midlands NHS Research Ethics Committee (12/EM/0190).

    PROTOCOL: The protocol was not published before trial commencement.

    Matched MeSH terms: Orthodontic Wires*
  10. Sockalingam SNMP, Zakaria ASI, Khan KAM, Azmi FM, Noor NM
    Case Rep Dent, 2020;2020:6972196.
    PMID: 32695527 DOI: 10.1155/2020/6972196
    The correction of rotated malpositioned tooth/teeth into the dental arch alignment in the mixed-dentition is often a challenging task for paediatric dentists. Failure in addressing this issue can bring about detrimental effect to the developing dentition and increases the probability of a complex orthodontic treatment in later years. Factors such as severity of the malpositioned teeth, patient's treatment compliance, limitation in specific functions of the selected appliance, availability of bone and space may dictate the success of the treatment. The combined use of a simple sectional orthodontic wire appliance and a 2 × 4 orthodontic appliance has been shown to produce a positive effect. The appliances resulted in derotation of the rotated malpositioned teeth and bringing them into arch alignment in two cases. This treatment option had eliminated the detrimental effects to the developing dentition and helped patients to enhance their smile and dental aesthetics.
    Matched MeSH terms: Orthodontic Wires
  11. Patil P, Hazarey V, Chaudhari R, Nimbalkar-Patil S
    Asian Pac J Cancer Prev, 2016;17(3):1255-9.
    PMID: 27039756
    BACKGROUND: Oral physiotherapy or mouth exercise is considered to be an adjunct but mandatory treatment modality for oral submucous fibrosis (OSMF). This study planned to evaluate the clinical efficacy of a newly designed mouth exercising device (MED) in OSMF patients receiving local ointment, intra-lesional drugs and surgical treatment.

    MATERIALS AND METHODS: A total of 231 OSMF patients were selected and treated with basic regime including topical corticosteroids, oral antioxidants and the icecream-stick exercise regime and allotted randomly to two equal groups A and B. Group-A patients were additionally given MED. Subgroups A1 and B1 patients with an inter-incisal distance (IID) 20-35mm were not given any additional therapy; subgroup A2 and B2 patients (IID 20-35mm) were treated additionally with intra-lesional injections. Subgroups A3 and B3 with IID<20mm were managed surgically. IID was measured at baseline and at 6 months recall. The change in IID measurements was calculated and statistically analyzed using 2-way ANOVA and Tukeys multiple post hoc analysis.

    RESULTS: Average improvement in IID after six months of recall visits was observed to be 8.4 mm in subgroup-A1 (n-53) compared to 5.5 mm in B1(n-50) (p<0.01). The IID improvement in subgroup-A2 was found to be 9.3mm (n-46) compared to 5.1 mm in B2 (n-48) (p<0.01). In the surgery group, mouth opening improvement was observed to be 9.6 mm in subgroup A3 (n-18) compared to 4.8 mm for B3 (n-16) (p<0.01).

    CONCLUSIONS: Use of the MED appears to be effective for increasing oral opening in OMSF patients in conjunction with local, injection and/or surgical treatment.

    Matched MeSH terms: Orthodontic Wires/statistics & numerical data*
  12. Sia S, Shibazaki T, Koga Y, Yoshida N
    Am J Orthod Dentofacial Orthop, 2009 Jan;135(1):36-41.
    PMID: 19121498 DOI: 10.1016/j.ajodo.2007.01.034
    This study was designed to determine the optimum vertical height of the retraction force on the power arm that is required for efficient anterior tooth retraction during space closure with sliding mechanics.
    Matched MeSH terms: Orthodontic Wires
  13. Wan Hassan WN, Stephenson PA, Waddington RJ, Sloan AJ
    J Dent, 2012 May;40(5):406-15.
    PMID: 22342686 DOI: 10.1016/j.jdent.2012.02.002
    Root resorption is a ubiquitous although undesirable sequela to orthodontic treatment. Current methods to investigate the pathophysiology have certain limitations. In pursuit to understand and develop treatment modalities for orthodontically induced root resorption, the ability to manipulate cells within their natural extracellular matrix in a three dimensional organotypic model is invaluable. The study aimed to develop a laboratory-based organotypic model to investigate the effect of orthodontic forces on the periodontium.
    Matched MeSH terms: Orthodontic Wires
Related Terms
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links