Displaying all 3 publications

Abstract:
Sort:
  1. Ideris SS, Che Hassan MR, Abdul Rahman MR, Ooi JS
    Ann Card Anaesth, 2017 Jan-Mar;20(1):28-32.
    PMID: 28074791 DOI: 10.4103/0971-9784.197824
    CONTEXT: Selecting an appropriate size double-lumen tube (DLT) for one-lung ventilation has always been a challenge as most choose it based on experience or using the existing guidelines based on gender and height.

    AIMS: The aim of this study was to determine if the appropriate choice of this tube could be based on the patients' height, weight, tracheal diameter (TD), or the left main stem bronchus diameter (LMBD) and also to determine the relationship between height and depth of insertion among Asians.

    SUBJECTS AND METHODS: This was a retrospective review of 179 patients who were intubated with a left-sided DLT and also had a posterior-anterior view of a digital chest radiograph for tracheal and left main bronchus diameter measurements. Additional data collected included patients' demographics and DLT size used.

    RESULTS: There were 123 (68.7%) males and 56 (31.3%) females with an overall mean age of 33.3 ± 16.3 years. Majority of the males (48.8%) used a size 39 Fr while females (46.4%) used a 35 Fr. There were weak correlations between DLT size with height (male: R2 = 0.222; female: R2 = 0.193), DLT size with weight (male: R2 = 0.109; female: R2 = 0.211), DLT size with TD (male: R2 = 0.027); female: R2 = 0.016), and DLT size with LMBD (male: R2 = 0.222; female: R2 = 0.193). There was a good correlation between depth of DLT inserted with patient's height for both genders.

    CONCLUSION: The appropriate size of the left-sided DLT could not be predicted based on patients' height, weight, tracheal or left main bronchus diameter alone in Asians; however, the depth of insertion of the tube was dependent on the height in both genders.
    Matched MeSH terms: One-Lung Ventilation/instrumentation*
  2. Mohd Esa NY, Faisal M, Vengadesa Pilla S, Abdul Rahaman JA
    BMJ Case Rep, 2020 Dec 22;13(12).
    PMID: 33370965 DOI: 10.1136/bcr-2020-236414
    Tracheal tear after endotracheal intubation is extremely rare. The role of silicone Y-stent in the management of tracheal injury has been documented in the previous studies. However, none of the studies have mentioned the deployment of silicone Y-stent via rigid bronchoscope with the patient solely supported by extracorporeal membrane oxygenation (ECMO) without general anaesthesia delivered via the side port of the rigid bronchoscope. We report a patient who had a tracheal tear due to endotracheal tube migration following a routine video-assisted thoracoscopic surgery sympathectomy, which was successfully managed with silicone Y-stent insertion. Procedure was done while she was undergoing ECMO; hence, no ventilator connection to the side port of the rigid scope was required. This was our first experience in performing Y-stent insertion fully under ECMO, and the patient had a successful recovery.
    Matched MeSH terms: One-Lung Ventilation/instrumentation
  3. Teah MK, Yap KY, Ismail AJ, Yeap TB
    BMJ Case Rep, 2021 Feb 17;14(2).
    PMID: 33597165 DOI: 10.1136/bcr-2020-241148
    Placement of a double-lumen tube to achieve one lung ventilation is an aerosol-generating procedure. Performing it on a patient with COVID-19 will put healthcare workers at high risk of contracting the disease. We herein report a case of its use in a patient with traumatic diaphragmatic rupture, who was also suspected to have COVID-19. This article aims to highlight the issues, it presented and ways to address them as well as the perioperative impact of personal protective equipment.
    Matched MeSH terms: One-Lung Ventilation/instrumentation
Related Terms
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links