Displaying all 18 publications

Abstract:
Sort:
  1. Mahat M, Abdullah WZ, Hussin CM
    J Immunol Res, 2014;2014:850810.
    PMID: 25759835 DOI: 10.1155/2014/850810
    Measurement of von Willebrand factor antigen (VWF : Ag) levels is usually performed in a specialised laboratory which limits its application in routine clinical practice. So far, no commercial rapid test kit is available for VWF : Ag estimation. This paper discusses the technical aspect of latex agglutination method which was established to suit the purpose of estimating von Willebrand factor (VWF) levels in the plasma sample. The latex agglutination test can be performed qualitatively and semiquantitatively. Reproducibility, stability, linearity, limit of detection, interference, and method comparison studies were conducted to evaluate the performance of this test. Semiquantitative latex agglutination test was strongly correlated with the reference immunoturbidimetric assay (Spearman's rho = 0.946, P < 0.001, n = 132). A substantial agreement (κ = 0.77) was found between qualitative latex agglutination test and the reference assay. Using the scoring system for the rapid latex test, no agglutination is with 0% VWF : Ag (control negative), 1+ reaction is equivalent to <20% VWF : Ag, and 4+ reaction indicates >150% VWF : Ag (when comparing with immunoturbidimetric assay). The findings from evaluation studies suggest that latex agglutination method is suitable to be used as a rapid test kit for the estimation of VWF : Ag levels in various clinical conditions associated with high levels and low levels of VWF : Ag.
    Matched MeSH terms: Nephelometry and Turbidimetry/methods
  2. Tan C, Seet G, Sluzek A, Wang X, Yuen CT, Fam CY, et al.
    Opt Express, 2010 Sep 27;18(20):21147-54.
    PMID: 20941011 DOI: 10.1364/OE.18.021147
    The range-gated imaging systems are reliable underwater imaging system with the capability to minimize backscattering effect from turbid media. The tail-gating technique has been developed to fine tune the signal to backscattering ratio and hence improve the gated image quality. However, the tail-gating technique has limited image quality enhancement in high turbidity levels. In this paper, we developed a numerical model of range-gated underwater imaging system for near target in turbid medium. The simulation results matched the experimental work favorably. Further investigation using this numerical model shows that the multiple scattering components of the backscattering noise dominate for propagation length larger than 4.2 Attenuation Length (AL). This has limited the enhancement of tail-gating technique in high turbidity conditions.
    Matched MeSH terms: Nephelometry and Turbidimetry/methods*
  3. Zainal-Abideen M, Aris A, Yusof F, Abdul-Majid Z, Selamat A, Omar SI
    Water Sci Technol, 2012;65(3):496-503.
    PMID: 22258681 DOI: 10.2166/wst.2012.561
    In this study of coagulation operation, a comparison was made between the optimum jar test values for pH, coagulant and coagulant aid obtained from traditional methods (an adjusted one-factor-at-a-time (OFAT) method) and with central composite design (the standard design of response surface methodology (RSM)). Alum (coagulant) and polymer (coagulant aid) were used to treat a water source with very low pH and high aluminium concentration at Sri-Gading water treatment plant (WTP) Malaysia. The optimum conditions for these factors were chosen when the final turbidity, pH after coagulation and residual aluminium were within 0-5 NTU, 6.5-7.5 and 0-0.20 mg/l respectively. Traditional and RSM jar tests were conducted to find their respective optimum coagulation conditions. It was observed that the optimum dose for alum obtained through the traditional method was 12 mg/l, while the value for polymer was set constant at 0.020 mg/l. Through RSM optimization, the optimum dose for alum was 7 mg/l and for polymer was 0.004 mg/l. Optimum pH for the coagulation operation obtained through traditional methods and RSM was 7.6. The final turbidity, pH after coagulation and residual aluminium recorded were all within acceptable limits. The RSM method was demonstrated to be an appropriate approach for the optimization and was validated by a further test.
    Matched MeSH terms: Nephelometry and Turbidimetry
  4. Yeap PK, Lim KO, Chong CS, Teng TT
    Chem Phys Lipids, 2008 Jan;151(1):1-9.
    PMID: 17963698
    As the packing structure of lipid molecules in the liposomes will vary in the presence of ions, it is expected that the density of lipid and the effective volume of lipid molecules in the dispersions will also vary, albeit minutely. Density measurements of lipid-water dispersions with the addition of Ca(2+) ions were determined accurately. The effect of Ca(2+) ions on the molecular packing structure of the liposomes was elucidated from the results obtained. The results for the density of the lecithin in the dispersions with and without the addition of Ca(2+) ions are, respectively, 1.0782 and 1.0579 g cm(-3) at 25 degrees C; and 1.0048 and 0.9961 g cm(-3) at 50 degrees C. The average values of the effective molecular volume of lecithin in the dispersions with and without the addition of Ca(2+) ions are, respectively, 1.131E-21 and 1.152E-21 cm(3) at 25 degrees C; and 1.213E-21 and 1.224E-21 cm(3) at 50 degrees C.
    Matched MeSH terms: Nephelometry and Turbidimetry
  5. Wong SS, Teng TT, Ahmad AL, Zuhairi A, Najafpour G
    J Hazard Mater, 2006 Jul 31;135(1-3):378-88.
    PMID: 16431022
    The flocculation performances of nine cationic and anionic polyacrylamides with different molecular weights and different charge densities in the treatment of pulp and paper mill wastewater have been studied. The experiments were carried out in jar tests with the polyacrylamide dosages range of 0.5-15 mg l(-1), rapid mixing at 200 rpm for 2 min, followed by slow mixing at 40 rpm for 15 min and settling time of 30 min. The effectiveness of the polyacrylamides was measured based on the reduction of turbidity, the removal of total suspended solids (TSS) and the reduction of chemical oxygen demand (COD). Cationic polyacrlyamide Organopol 5415 with very high molecular weight and low charge density is found to give the highest flocculation efficiency in the treatment of the paper mill wastewater. It can achieve 95% of turbidity reduction, 98% of TSS removal, 93% of COD reduction and sludge volume index (SVI) of 14 ml g(-1) at the optimum dosage of 5 mg l(-1). SVI values of less than 70 m lg(-1) are found for all polyacrylamide at their respective optimum dosage. Based on the cost evaluation, the use of the polyacrylamides is economically feasible to treat the pulp and paper mill wastewaters. This result suggests that single-polymer system can be used alone in the coagulation-flocculation process due to the efficiency of the polyacrylamide. Sedimentation of the sludge by gravity thickening with settling time of 30 min is possible based on the settling characteristics of the sludge produced by Organopol 5415 that can achieve 91% water recovery and 99% TSS removal after 30 min settling.
    Matched MeSH terms: Nephelometry and Turbidimetry
  6. Mannan S, Fakhru'l-Razi A, Alam MZ
    Water Res, 2005 Aug;39(13):2935-43.
    PMID: 16000208
    The present study was designed to evaluate the potential of microbial adaptation and its affinity to biodegradation as well as bioconversion of soluble/insoluble (organic) substances of domestic wastewater treatment plant (DWTP) sludge (activated domestic sludge) under natural/non-sterilized conditions. The two filamentous fungi, Penicillium corylophilum (WWZP1003) and Aspergillus niger (SCahmA103) were used to achieve the objectives. It was observed that P. corylophilum (WWZP1003) was the better strain compared to A. niger (SCahmA103) for the bioconversion of domestic activated sludge through adaptation. The visual observation in plate culture showed that about 95-98% of cultured microbes (P. corylophilum and A. niger) dominated in treated sludge after 2 days of treatment. In this study, it was also found that the P. corylophilum was capable of removing 94.40% of COD and 98.95% of turbidity of filtrate with minimum dose of inoculum of 10% v/v in DWTP sludge (1% w/w). The pH level was lower (acidic condition) in the fungal treatment and maximum reduction of COD and turbidity was observed (at lower pH). The results for specific resistance to filtration (SRF) showed that the fungi played a great role in enhancing the dewaterability and filterability. In particular, the strain Penicillium had a more significant capability (than A. niger) of reducing 93.20% of SRF compared to the uninoculated sample. Effective results were observed by using fungal inoculum after 2 days of treatment. The developed LSB process is a new biotechnological approach for sludge management strategy.
    Matched MeSH terms: Nephelometry and Turbidimetry
  7. Karami N, Mohammadi P, Zinatizadeh A, Falahi F, Aghamohammadi N
    Ultrason Sonochem, 2018 Sep;46:89-98.
    PMID: 29739516 DOI: 10.1016/j.ultsonch.2018.04.009
    The biomass concentration of conventional activated sludge (CAS) process due to low sludge sedimentation in clarifiers is limited to 3000 mg/L. In this study, high-frequency ultrasound wave (1.8 MHz) was applied to enhance the CAS process performance using high Mixed Liquor Suspended Solid (MLSS) concentration. The study conducted using a pilot scale CAS bioreactor (with and without ultrasound) and their performance for treating a hospital wastewater were compared. Experimental conditions were designed based on a Central Composite Design (CCD). The sets of data analyzed, modeled and optimized using Response Surface Methodology (RSM). The effect of MLSS concentration 3000-8000 mg/L and hydraulic retention time (HRT) 2-8 h are considered as operating variables to investigate on process responses. The obtained results showed that high-frequency ultrasound was significantly decreased the sludge volume index (SVI) 50% and effluent turbidity about 88.5% at high MLSS. Also, observed that COD removal of both systems was nearly similar, as the maximum COD removal for sonicated and non-sonicated systems were 92 and 92.5% respectively. However, this study demonstrates that the ultrasound irradiation has not had any negative effect on the microbial activity.
    Matched MeSH terms: Nephelometry and Turbidimetry
  8. Katayon S, Noor MJ, Asma M, Ghani LA, Thamer AM, Azni I, et al.
    Bioresour Technol, 2006 Sep;97(13):1455-60.
    PMID: 16213137
    Moringa oleifera is a plant whose seeds have coagulation properties for treating water and wastewater. In this study the coagulation efficiency of Moringa oleifera kept in different storage conditions were studied. The Moringa oleifera seeds were stored at different conditions and durations; open container and closed container at room temperature (28 degrees C) and refrigerator (3 degrees C) for durations of 1, 3 and 5 months. Comparison between turbidity removal efficiency of Moringa oleifera kept in refrigerator and room temperature revealed that there was no significant difference between them. The Moringa oleifera kept in refrigerator and room temperature for one month showed higher turbidity removal efficiency, compared to those kept for 3 and 5 months, at both containers. The coagulation efficiency of Moringa oleifera was found to be dependent on initial turbidity of water samples. Highest turbidity removals were obtained for water with very high initial turbidity. In summary coagulation efficiency of Moringa oleifera was found independent of storage temperature and container, however coagulation efficiency of Moringa oleifera decreased as storage duration increased. In addition, Moringa oleifera can be used as a potential coagulant especially for very high turbidity water.
    Matched MeSH terms: Nephelometry and Turbidimetry/methods*
  9. Golestanbagh M, Ahamad IS, Idris A, Yunus R
    J Water Health, 2011 Sep;9(3):597-602.
    PMID: 21976206 DOI: 10.2166/wh.2011.035
    Moringa oleifera is an indigenous plant to Malaysia whose seeds are used for water purification. Many studies on Moringa oleifera have shown that it is highly effective as a natural coagulant for turbidity removal. In this study, two different methods for extraction of Moringa's active ingredient were investigated. Results of sodium chloride (NaCl) and distilled water extraction of Moringa oleifera seeds showed that salt solution extraction was more efficient than distilled water in extracting Moringa's active coagulant ingredient. The optimum dosage of shelled Moringa oleifera seeds extracted by the NaCl solution was comparable with that of the conventional chemical coagulant alum. Moreover, the turbidity removal efficiency was investigated for shelled Moringa oleifera seeds before drying in the oven under different storage conditions (i.e. open and closed containers at room temperature, 27 °C) and durations (fresh, and storage for 2, 4, 6 and 8 weeks from the time the seeds were picked from the trees). Our results indicate that there are no significant differences in coagulation efficiencies and, accordingly, turbidity removals between the examined storage conditions and periods.
    Matched MeSH terms: Nephelometry and Turbidimetry
  10. Bashir MJ, Aziz HA, Yusoff MS, Huqe AA, Mohajeri S
    Water Sci Technol, 2010;61(3):641-9.
    PMID: 20150700 DOI: 10.2166/wst.2010.867
    Landfill leachate is one of the major contamination sources. In this study, the ability of synthetic ion exchange resins which carry different mobile ion for removing color, chemical oxygen demand (COD), and ammonia nitrogen (NH(3)-N) from stabilized leachate was investigated. The synthetic resin INDION 225 Na as a cationic exchanger and INDION FFIP MB as an anionic exchanger were used in this study. INDION 225 Na was used in hydrogen form (H(+)) and in sodium form (Na(+)), while INDION FFIP MB resin was used in hydroxide form (OH(-)) and in calcium form (Cl(-)) form. The results indicated better removal of color, COD and NH(3)-N by using INDION 225 Na in H(+) as compared with Na(+) form, while no performance differences were observed by using INDION FFIP MB in OH(-) or Cl(-) form. Applying cationic resin followed by anionic resin achieved 97, 88 and 94, percent removal of color, COD and NH(3)-N. The residual amounts were 160 Pt-Co, 290 mg/L and 110 mg/L of color, COD and NH(3)-N respectively.
    Matched MeSH terms: Nephelometry and Turbidimetry
  11. Ho YC, Norli I, Alkarkhi AF, Morad N
    Water Sci Technol, 2009;60(3):771-81.
    PMID: 19657173 DOI: 10.2166/wst.2009.303
    The performance of pectin in turbidity reduction and the optimum condition were determined using Response Surface Methodology (RSM). The effect of pH, cation's concentration, and pectin's dosage on flocculating activity and turbidity reduction was investigated at three levels and optimized by using Box-Behnken Design (BBD). Coagulation and flocculation process were assessed with a standard jar test procedure with rapid and slow mixing of a kaolin suspension (aluminium silicate), at 150 rpm and 30 rpm, respectively, in which a cation e.g. Al(3+), acts as coagulant, and pectin acts as the flocculant. In this research, all factors exhibited significant effect on flocculating activity and turbidity reduction. The experimental data and model predictions well agreed. From the 3D response surface graph, maximum flocculating activity and turbidity reduction are in the region of pH greater than 3, cation concentration greater than 0.5 mM, and pectin dosage greater than 20 mg/L, using synthetic turbid wastewater within the range. The flocculating activity for pectin and turbidity reduction in wastewater is at 99%.
    Matched MeSH terms: Nephelometry and Turbidimetry
  12. Siti Farizwana MR, Mazrura S, Zurahanim Fasha A, Ahmad Rohi G
    J Environ Public Health, 2010;2010:615176.
    PMID: 21461348 DOI: 10.1155/2010/615176
    The study was to determine the concentration of aluminium (Al) and study the physicochemical parameters (pH, total dissolved solids (TDS), turbidity, and residual chlorine) in drinking water supply in selected palm oil estates in Kota Tinggi, Johor. Water samples were collected from the estates with the private and the public water supplies. The sampling points were at the water source (S), the treatment plant outlet (TPO), and at the nearest houses (H1) and the furthest houses (H2) from the TPO. All estates with private water supply failed to meet the NSDWQ for Al with mean concentration of 0.99 ± 1.52 mg/L. However, Al concentrations in all public water supply estates were well within the limit except for one estate. The pH for all samples complied with the NSDWQ except from the private estates for the drinking water supply with an acidic pH (5.50 ± 0.90). The private water supply showed violated turbidity value in the drinking water samples (14.2 ± 24.1 NTU). Insufficient amount of chlorination was observed in the private water supply estates (0.09 ± 0.30 mg/L). Private water supplies with inefficient water treatment served unsatisfactory drinking water quality to the community which may lead to major health problems.
    Matched MeSH terms: Nephelometry and Turbidimetry
  13. Alam MZ, Muyibi SA, Jamal P
    PMID: 17849310
    Biological treatment of sewage treatment plant (STP) sludge by potential pure bacterial culture (Bacillus sp.) with optimum process conditions for effective biodegradation and bioseparation was carried out in the laboratory. The effective and efficient bioconversion was evaluated with the treatment of pure bacterial culture and existing microbes (uninnoculated) in sludge. The optimum process conditions i.e., temperature, 40 degrees C; pH, 6; inoculum, 5% (v/v); aeration, 1 vvm; agitation speed, 50 rpm obtained from the previous studies with chemical oxygen demand COD at 30 mgL(-1) were applied for the biological treatment of sludge. The results indicated that pure bacterial culture (Bacillus sp.) showed higher degradation and separation of treated sludge compared to treatment with the existing mixed microbes in a stirred tank bioreactor. The treated STP sludge by potential pure bacterial culture and existing microbes gave 30% and 11%; 91.2% and 59.1; 88.5% and 52.3%; 98.4% and 51.3%; 96.1% and 75.2%; 99.4% and 72.8% reduction of total suspended solids (TSS, biosolids), COD, soluble protein, turbidity, total dissolved solids (TDS) and specific resistance to filtration (SRF), respectively within 7 days of treatment. The pH was observed at 6.5 and 4 during the treatment of sludge by pure culture and existing microbes, respectively.
    Matched MeSH terms: Nephelometry and Turbidimetry
  14. Ahmad AL, Ismail S, Bhatia S
    Environ Sci Technol, 2005 Apr 15;39(8):2828-34.
    PMID: 15884382
    The coagulation-flocculation process incorporated with membrane separation technology will become a new approach for palm oil mill effluent (POME) treatment as well as water reclamation and reuse. In our current research, a membrane pilot plant has been used for POME treatment where the coagulation-flocculation process plays an important role as a pretreatment process for the mitigation of membrane fouling problems. The pretreated POME with low turbidity values and high water recovery are the main objectives to be achieved through the coagulation-flocculation process. Therefore, treatment optimization to serve these purposes was performed using jar tests and applying a response surface methodology (RSM) to the results. A 2(3) full-factorial central composite design (CCD) was chosen to explain the effect and interaction of three factors: coagulant dosage, flocculent dosage, and pH. The CCD is successfully demonstrated to efficiently determine the optimized parameters, where 78% of water recovery with a 20 NTU turbidity value can be obtained at the optimum value of coagulant dosage, flocculent dosage, and pH at 15 000 mg/L, 300 mg/L, and 6, respectively.
    Matched MeSH terms: Nephelometry and Turbidimetry
  15. Ho YC, Norli I, Alkarkhi AF, Morad N
    J Water Health, 2015 Jun;13(2):489-99.
    PMID: 26042980 DOI: 10.2166/wh.2014.100
    In view of green developments in water treatment, plant-based flocculants have become the focus due to their safety, degradation and renewable properties. In addition, cost and energy-saving processes are preferable. In this study, malva nut gum (MNG), a new plant-based flocculant, and its composite with Fe in water treatment using single mode mixing are demonstrated. The result presents a simplified extraction of the MNG process. MNG has a high molecular weight of 2.3 × 10⁵ kDa and a high negative charge of -58.7 mV. From the results, it is a strong anionic flocculant. Moreover, it is observed to have a branch-like surface structure. Therefore, it conforms to the surface of particles well and exhibits good performance in water treatment. In water treatment, the Fe-MNG composite treats water at pH 3.01 and requires a low concentration of Fe and MNG of 0.08 and 0.06 mg/L, respectively, when added to the system. It is concluded that for a single-stage flocculation process, physico-chemical properties such as molecular weight, charge of polymer, surface morphology, pH, concentration of cation and concentration of biopolymeric flocculant affect the flocculating performance.
    Matched MeSH terms: Nephelometry and Turbidimetry
  16. Alam MZ, Fakhru'l-Razi A, Idris A, Abd-Aziz S
    PMID: 12227649
    The bioconversion of domestic wastewater sludge by immobilized mixed culture of filamentous fungi was investigated in a laboratory. The potential mixed culture of Penicillium corylophilum WWZA1003 and Aspergillus niger SCahmA103 was isolated from its local habitats (wastewater and sludge cake) and optimized on the basis of biodegradability and dewaterability of treated sludge. The observed results in this study showed that the sludge treatment was highly influenced by the effect of immobilized mixed fungi using liquid state bioconversion (LSB) process. The maximum production of dry filter cake (DFC) was enriched with fungal biomass to about 20.05 g/kg containing 23.47 g/kg of soluble protein after 4 days of fungal treatment. The reduction of COD, TSS, turbidity (optical density against distilled water, 660 nm), reducing sugar and protein in supernatant and filtration rate of treated sludge were influenced by the fungal mixed culture as compared to control (uninnoculated). After these processes, 99.4% of TSS, 98.05% of turbidity, 76.2% of soluble protein, 98% of reducing sugar and 92.4% of COD in supernatant of treated sludge were removed. Filtration time was decreased tremendously by the microbial treatment after 2 days of incubation. The effect of fungal strain on pH was also studied and presented. Effective bioconversion was observed after 4 days of fungal treatment.
    Matched MeSH terms: Nephelometry and Turbidimetry
  17. Lasekan O, Salva JT, Abbas K
    J Sci Food Agric, 2010 Apr 15;90(5):850-60.
    PMID: 20355122 DOI: 10.1002/jsfa.3895
    Considering the importance of malting and roasting on the quality of 'acha' beverages, a study was conducted to find optimum conditions for malting and the production of a high-quality roasted extract that could be used for an 'acha' beverage.
    Matched MeSH terms: Nephelometry and Turbidimetry
  18. Abd Wahid MA, Megat Mohd Noor MJ, Goto M, Sugiura N, Othman N, Zakaria Z, et al.
    Biosci Biotechnol Biochem, 2017 Aug;81(8):1642-1649.
    PMID: 28585494 DOI: 10.1080/09168451.2017.1329617
    The natural coagulant Moringa oleifera lectin (MoL) as cationic protein is a promising candidate in coagulation process of water treatment plant. Introducing the gene encoding MoL into a host, Pichia pastoris, to secrete soluble recombinant protein is assessed in this study. Initial screening using PCR confirmed the insertion of MoL gene, and SDS-PAGE analysis detected the MoL protein at 8 kDa. Cultured optimization showed the highest MoL protein at 520 mg/L was observed at 28 °C for 144 h of culturing by induction in 1% methanol. Approximately, 0.40 mg/mL of recombinant MoL protein showed 95 ± 2% turbidity removal of 1% kaolin suspension. In 0.1% kaolin suspension, the concentration of MoL at 10 μg/mL exhibits the highest turbidity reduction at 68 ± 1%. Thus, recombinant MoL protein from P. pastoris is an effective coagulant for water treatment.
    Matched MeSH terms: Nephelometry and Turbidimetry
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links