Displaying publications 1 - 20 of 49 in total

Abstract:
Sort:
  1. Zarina AL, Rahmah R, Bador KM, Ng SF, Wu LL
    Med J Malaysia, 2008 Oct;63(4):325-8.
    PMID: 19385494 MyJurnal
    Newborn screening for congenital hypothyroidism (CH) was implemented in Hospital UKM in December 2004 using cord blood sample. From the audit over a period of 25 months, a total of 13,875 newborn babies were screened with a coverage of 98.8%. From this cohort, the mean recall rate was 0.32%; unfortunately the mean percentage of recalled babies that came for retesting was only 79.5%. In addition, the mean sample rejection rate was high, i.e. 2.2%. Two babies were diagnosed to have CH. These findings implied that whilst the coverage of screening was good, there is a need for regular surveillance of performance of both clinical and laboratory personnel. In addition, a more concerted effort should be carried out to promote community awareness of such a programme.
    Matched MeSH terms: Neonatal Screening*
  2. Teow Kheng Leong K, Abu Kassim SNA, Sidhu JK, Zohari Z, Sivalingam T, Ramasamy S, et al.
    BMC Ophthalmol, 2021 Mar 09;21(1):128.
    PMID: 33750348 DOI: 10.1186/s12886-021-01882-x
    BACKGROUND: The current practice for new-born eye examination by an Ophthalmologist in Malaysian hospitals is limited to only preterm new-borns, syndromic or ill infants. Healthy term new-borns are usually discharged without a thorough eye examination. This study is aimed at determining the proportion and types of ocular abnormalities detected in purportedly healthy term new-borns.

    METHOD: This cross-sectional study is comprised of 203 participants, all purportedly healthy term new-born infants from the Obstetrics and Gynaecology ward at Hospital Kuala Lumpur over a 6 months period. The examination list includes external eye examination, red reflex test, and fundus imaging using a wide-field digital retinal imaging system (Phoenix Clinical ICON Paediatric Retinal Camera) by a trained Investigator. The pathologies detected were documented. The results were compared and correlated with similar studies published in the literature previously.

    RESULTS: Total ocular abnormalities were detected in 34% of the infants. The most common finding was retinal haemorrhage in 29.6% of the infants, of which 53.3% occurred bilaterally. Spontaneous vaginal delivery (SVD) remained the greatest risk factor which has nearly 3.5 times higher risk of new-borns developing retinal haemorrhage compared to Lower Segment Caesarean Section (LSCS). There was a 6% increased likelihood of developing retinal haemorrhage for every 1-min increment in the duration of 2nd stage of labour.

    CONCLUSION: Universal eye screening for all new-borns using a wide-field digital imaging system is realistically possible, safe, and useful in detecting posterior segment disorders. The most common abnormality detected is retinal haemorrhage.

    Matched MeSH terms: Neonatal Screening*
  3. Wong YA, Mazlan R, Abdul Wahab NA, Ja'afar R, Huda Bani N, Abdullah NA
    J Med Screen, 2021 09;28(3):238-243.
    PMID: 33202173 DOI: 10.1177/0969141320973060
    OBJECTIVE: To evaluate and discuss the outcomes of the universal newborn hearing screening program conducted at four public hospitals in Malaysia.

    METHOD: A retrospective analysis of the universal newborn hearing screening database from each hospital was performed. The database consisted of 28,432 and 30,340 screening results of babies born in 2015 and 2016, respectively. Quality indicators (coverage rate, referral rate, return for follow-up rate, and ages at screening and diagnosis) were calculated.

    RESULTS: Overall coverage rate across the four hospitals was 75% in 2015 and 87.4% in 2016. Over the two years, the referral rates for the first screening ranged from 2.7% to 33.93% with only one hospital achieving the recommended benchmark of <4% in both years. The return for follow-up rates for each participating hospital was generally below the recommended benchmark of ≥95%. The mean age at screening was 3.9 ± 1.2 days and 3.3 ± 0.4 days, respectively. The mean age at diagnosis for 70 infants diagnosed with permanent hearing loss was 4.7 ± 0.7 months in 2015 and 3.6 ± 0.9 months in 2016.

    CONCLUSIONS: Quality measures for the universal newborn hearing screening program in four public hospitals in Malaysia were lower than the required standards. Nevertheless, some quality indicators showed statistically significant improvements over the two years. Next steps involve identifying and implementing the best practice strategies to improve the outcome measures and thus the quality of the program.

    Matched MeSH terms: Neonatal Screening*
  4. George E, Lai MI, Teh LK, Ramasamy R, Goh EH, Asokan K, et al.
    Med J Malaysia, 2011 Dec;66(5):429-34.
    PMID: 22390095 MyJurnal
    Detection and quantification of Hb subtypes of human blood is integral to presumptive identification of thalassaemias. It has been used in neonatal screening of thalassaemia and Hb variants. The use of discarded red blood cells following processing of the cord blood for stem cells provides readily available diagnostic material for thalassaemia screening. In this study, we determined the range of Hb subtypes in 195 consecutive cord blood samples collected for cord blood banking. The 'cord blood samples' analysed were those of the remaining red blood cells after the cord blood was processed for stem cell storage. Quantification of Hb subtypes by high performance liquid chromatography (HPLC) was done on BioRad Variant II Hb testing system. Only 73 (36.5%) of the samples could be analyzed neat without dilution. With a 1:300 dilution with wash solution the acceptable area as recommended by the manufacturer for reading of a C-gram within the 1 to 3 million ranges were achieved in all. Eighteen (9%) 12 showed classical Hb Barts (y4) prerun peaks were confirmed by Sebia Hydrasys automated Hb gel electrophoresis and quantified by Sebia Capillarys 2 capillary electrophoresis. Only 1 (0.5%) was presumptively identified with HbH disease. Due to the limited number of samples no beta-thalassaemia major, Hb E beta-thalassaemia and Hb Barts hydrops fetalis were found. The HPLC assay was possible at a cost US$ 5 per sample and a turnover time of 10 samples per hour without technical difficulties. This study reports an effective and valuable protocol for thalassaemia screening in red blood cells which would otherwise be discarded during cord blood processing. Cord blood with severe and intermediate forms of thalassaemia can be preselected and not stored.
    Matched MeSH terms: Neonatal Screening/instrumentation; Neonatal Screening/methods*
  5. Padilla CD, Therrell BL
    J Inherit Metab Dis, 2007 Aug;30(4):490-506.
    PMID: 17643195
    The success of blood spot newborn screening in the USA led to early screening efforts in parts of the Asia Pacific Region in the mid-1960s. While there were early screening leaders in the region, many of the countries with depressed and developing economies are only now beginning organized screening efforts. Four periods of screening growth in the Asia Pacific region were identified. Beginning in the 1960s, blood spot screening began in New Zealand and Australia, followed by Japan and a cord blood screening programme for G6PD deficiency in Singapore. In the 1980s, established programmes added congenital hypothyroidism and new programmes developed in Taiwan, Hong Kong, China (Shanghai), India and Malaysia. Programmes developing in the 1990s built on the experience of others developing more rapidly in Korea, Thailand and the Philippines. In the 2000s, with limited funding support from the International Atomic Energy Agency, there has been screening programme development around detection of congenital hypothyroidism in Indonesia, Mongolia, Sri Lanka, Myanmar and Pakistan. Palau has recently contracted with the Philippine newborn screening programme. There is little information available on newborn screening activities in Nepal, Cambodia, Laos and the other Pacific Island nations, with no organized screening efforts apparent. Since approximately half of the births in the world occur in the Asia Pacific Region, it is important to continue the ongoing implementation and expansion efforts so that these children can attain the same health status as children in more developed parts of the world and their full potential can be realized.
    Matched MeSH terms: Neonatal Screening/methods*; Neonatal Screening/trends*
  6. Chua BS, Song LH, Chang CT, Lim XJ, Nachiappan J
    J Paediatr Child Health, 2021 01;57(1):12-14.
    PMID: 33078471 DOI: 10.1111/jpc.15226
    The coronavirus disease 2019 (COVID-19) cases was on an increasing trend, including in Malaysia. The Malaysian Ministry of Health had implemented a range of measures, such as the use of masks and social distancing, to reduce the risk of transmission. Traditionally, newborns are evaluated for neonatal jaundice using visual assessment, a capillary heel prick and serum bilirubin (SB) sampling in primary health-care clinics. This approach requires the physical presence of both parents and their newborns in the primary health-care clinics, causing crowding and increasing the risk of COVID-19 infections. To alleviate crowding, we implemented the transcutaneous bilirubin drive-through (DT) service, which is an established, non-invasive, painless and rapid method to determine the bilirubin levels. Throughout the screening, both parents and baby will be confined to their car. A total of 1842 babies were screened in our DT setting from April to July 2020. Of the total babies, 298 (16.1%) required venesection for SB measurement and 85 required admission for phototherapy. None with severe jaundice were missed since the implementation of this service. The average test duration per neonate was less than 5 min, while conventional venous bilirubin laboratory testing required an average of 1.5 h per neonate. The cost of the SB laboratory test and consumables was approximately USD 5 per test, with an estimated cost savings of USD 7720. DT screening may be introduced in health-care settings to reduce crowding and eliminate the need of painful blood sampling in newborns.
    Matched MeSH terms: Neonatal Screening/methods*; Neonatal Screening/organization & administration
  7. Boo NY, Chang YF, Leong YX, Tok ZY, Hooi LC, Chee SC, et al.
    Pediatr Res, 2019 08;86(2):216-220.
    PMID: 30696987 DOI: 10.1038/s41390-019-0304-0
    BACKGROUND: This study aimed to determine the accuracy of a point-of-care Bilistick method for measuring total serum bilirubin (TSB) and its turn-around-time (TAT) against hospital laboratory methods.

    METHODS: This prospective study was carried out on 561 term-gestation jaundiced neonates in two Malaysian hospitals. Venous blood sample was collected from each neonate for contemporary measurement of TSB by hospital laboratories and Bilistick. TAT was the time interval between specimen collection and TSB result reported by each method.

    RESULTS: The mean laboratory-measured TSB was 194.85 (±2.844) µmol/L and Bilistick TSB was 169.37 (±2.706) µmol/L. Pearson's correlation coefficient was: r = 0.901 (p 

    Matched MeSH terms: Neonatal Screening/instrumentation*; Neonatal Screening/methods
  8. Ainoon O, Alawiyah A, Yu YH, Cheong SK, Hamidah NH, Boo NY, et al.
    PMID: 12971572
    Neonatal screening for G6PD deficiency has long been established in many countries. The aim of the study was to determine whether the routine semiquantitative fluorescent spot test could detect all cases of G6PD deficiency, including those cases with partial deficiency (residual red cell G6PD activity between 20-60% of normal). We compared the results of G6PD screening by the semiquantitative fluorescent spot test and quantitative G6PD activity assay on a group of 976 neonates and 67 known female heterozygotes. The values for mean G6PD activity of G6PD-normal neonates and 293 healthy adult females were determined. There was no significant difference in the mean normal G6PD activity between the two racial groups in the neonates (669 Malays, 307 Chinese) and in the 293 healthy adult females (150 Malays, 143 Chinese) group. The values for the upper limits of total deficiency (20% of normal residual activity) for neonates and adult females were 2.92 U/gHb and 1.54 U/gHb, respectively. The upper limits of partial deficiency (60% of normal residual activity) were 8.7 U/gHb and 4.6 U/gHb respectively. The prevalence of G6PD deficiency among the male neonates was 5.1% (26) by both the fluorescent spot test and the enzyme assay method. The G6PD activity levels of all 26 cases of G6PD-deficient male neonates were < 20% normal (severe enzyme deficiency). In the female neonate group, the frequency of G6PD deficiency was 1.3% (6 of 472) by the fluorescent spot test and 9.35% (44 of 472) by enzyme assay. The 6 cases diagnosed as deficient by the fluorescent spot test showed severe enzyme deficiency (< 2.92 U/gHb). The remaining 38 female neonates had partial enzyme deficiency and all were misdiagnosed as normal by the fluorescent spot test. In the female heterozygote group, G6PD deficiency was diagnosed in 53% (35 of 67) by enzyme assay and in 7.5% (4 of 67) of cases by the fluorescent spot test. The 4 cases detected by fluorescent spot test had severe enzyme deficiency (<1.6 U/gHb). The remaining 31 (46.3%) cases, diagnosed as normal by fluorescent spot test, showed partial G6PD deficiency. In conclusion, we found that the semiquantitative fluorescent spot test could only diagnose cases of total G6PD deficiency and misclassified the partially-deficient cases as normal. In this study, the overall prevalence of G6PD deficiency was 3.28% by the semiquantitative fluorescent spot test and 7.17% by enzyme assay. This means that 3.9% of G6PD-deficient neonates were missed by the routine fluorescent spot test and they were found to be exclusively females. This study demonstrates a need to use a method that can correctly classify female heterozygotes with partial G6PD deficiency. The clinical implication is that these individuals may be at risk of the hemolytic complication of G6PD deficiency.
    Matched MeSH terms: Neonatal Screening/methods; Neonatal Screening/standards*
  9. Kazemi T, Firgau E, Bunch D, Kahwash SB
    Malays J Pathol, 2022 Dec;44(3):523-526.
    PMID: 36591720
    Medium-chain acyl CoA dehydrogenase deficiency (MCADD) and other inborn errors of metabolism are common causes of Sudden Unexpected Deaths in Infancy (SUDI). If identified early or before metabolic decompensation, MCADD is manageable. In the US and other countries, identification of MCADD has improved through the routine use of newborn screening (NBS), which is able to identify most cases. This case study presented here occurred before NBS was implemented in Ohio for MCADD and outlines the typical clinical presentation, pathological features, and relevant biochemical and molecular markers for identifying MCADD. Genetic counselling should be sought for the family if MCADD is identified.
    Matched MeSH terms: Neonatal Screening
  10. Al-Herz W, Ziyab AH, Adeli M, Al Farsi T, Al-Hammadi S, Al Kuwaiti AA, et al.
    Clin Immunol, 2023 Sep;254:109696.
    PMID: 37481010 DOI: 10.1016/j.clim.2023.109696
    AIMS: To understand the characteristics of combined immunodeficiency disorders that affect cellular and humoral immunity (CID) in the Arabian Peninsula.

    METHODS: Retrospective study of 236 patients with CID from the region were enrolled from 2004 to 2022.

    RESULTS: 236 patients were included with a majority being profound CID. Among patients with a family history of CID, the ages at onset and diagnosis, and the delay in diagnosis were lower compared to those with no family history of CID, but this did not affect time to transplant. HSCT was performed for 51.27% of the patients with median time from diagnosis to HSCT of 6.36 months. On multivariate analysis, patients who underwent early transplant had increased odds of having CD3 count ≤1000 cell/μl, diagnosed by screening or erythroderma.

    CONCLUSION: There is a delay in diagnosis and treatment of CID in our region. Establishing newborn screening programs and HSCT units in our region are the urgent need.

    Matched MeSH terms: Neonatal Screening
  11. Mazlan R, Ting TL, Mukari SZ, Abdullah A
    Int J Pediatr Otorhinolaryngol, 2014 Feb;78(2):348-53.
    PMID: 24380662 DOI: 10.1016/j.ijporl.2013.12.014
    The present study aimed to determine levels of parents' satisfaction associated with the universal newborn hearing screening process in a university hospital setting in Kuala Lumpur, Malaysia.
    Matched MeSH terms: Neonatal Screening/methods*
  12. Abdul Wahid SN, Md Daud MK, Sidek D, Abd Rahman N, Mansor S, Zakaria MN
    Int J Pediatr Otorhinolaryngol, 2012 Sep;76(9):1366-9.
    PMID: 22770594 DOI: 10.1016/j.ijporl.2012.06.008
    OBJECTIVE: To identify the outcomes of hearing screening using different protocols of both Distortion Product Otoacoustic Emissions (DPOAE) and Automated Auditory Brainstem Response (AABR) tests in the same ear of the babies in a neonatal unit population.
    METHODS: A cross-sectional study was carried out on babies who were admitted into a neonatal unit. By using a formula of single proportion and considering 20% drop out, the number of sample required was 114. The subjects were chosen by using a systematic random sampling. The infants selected were subjected to DPOAE followed by AABR tests screening at the same setting before discharge.
    RESULTS: There were 73 newborns (61.6% male and 38.4% female) participated in this study with a total of 146 ears screened. Ototoxic medication was the most common risk factor followed by hyperbilirubinaemia and low birth weight. AABR had higher passing rate (82.9%) as compared to DPOAE (77.4%). The highest passing rate was achieved if the protocol of either passed DPOAE or AABR was used (90.4%). The rate was lower when auditory neuropathy spectrum disorder (ANSD) has been considered (82.9%). Hyperbilirubinaemia, prematurity, craniofacial malformation and ototoxic drugs seem to be the high risk factors for auditory neuropathy.
    CONCLUSION: AABR has a higher passing rate as compared to DPOAE. However, the use of both instruments in the screening process especially in NICU will be useful to determine the infants with ANSD who may need different approach to management. Therefore, a protocol in which newborns are tested with AABR first and then followed by DPOAE on those who fail the AABR is recommended.
    Matched MeSH terms: Neonatal Screening/methods*
  13. Asma A, Wan Fazlina WH, Almyzan A, Han YS, Jamilah AG, Roslin S, et al.
    Med J Malaysia, 2008 Oct;63(4):293-7.
    PMID: 19385487 MyJurnal
    The importance of universal newborn hearing screening (UNHS) in identifying hearing-impaired infants as early as possible is already well recognized. Transient evoked otoacoustic emissions (TEOAE) have been established as a reliable method for UNHS in full term infants. This is a cross sectional study between April 2003--December 2005. Thirteen thousand five hundred and ninety eight (13,598) newborns were screened for hearing loss with portable otoacoustic emission (OAE) before discharge. The initial coverage rate during the 3 years study period was 85.9% (13,598) with 89.2% (3762), 79.0% (4480) and 90.3% (5356) for 2003, 2004 and 2005 respectively. The mean age when hearing loss was diagnosed using ABR were 3.56 months old, 3.08 months old, and 2.25 months old and 3.01 months old for 2003, 2004, 2005 respectively and it was statistically significant. The defaulter rate at the third stage during the 3 years study period was 35% (21), 15.2% (7) and 18.2% (2) for 2003, 2004 and 2005 respectively. This study showed significant improvement in initial referral rate, coverage rate and age of diagnosis. However, we need to improve on high defaulter rates.
    Matched MeSH terms: Neonatal Screening*
  14. Abdullah A, Long CW, Saim L, Mukari SZM
    Med J Malaysia, 2005 Mar;60(1):21-7.
    PMID: 16250276 MyJurnal
    Early identification and management of hearing impairment is very valuable. The goal standard measurement of hearing loss is by brainstem evoked response (BSER). This prospective study was conducted in Hospital University Kebangsaan Malaysia (HUKM) to determine the sensitivity and specificity of transient evoked otoacoustic emission (TEOAE) as a screening tool for hearing impairment from February 1999 to February 2000. One hundred and thirty-three newborns from postnatal ward and seventy-eight newborns from neonatal intensive care unit (NICU) were screened for possible hearing loss using portable TEOAE. This study showed that TEOAE is a very sensitive but moderately specific screening tool.
    Matched MeSH terms: Neonatal Screening*
  15. Khairi MD, Din S, Shahid H, Normastura AR
    J Laryngol Otol, 2005 Sep;119(9):678-83.
    PMID: 16156907
    The objective of this prospective study was to report on the prevalence of hearing impairment in the neonatal unit population. From 15 February 2000 to 15 March 2000 and from 15 February 2001 to 15 May 2001, 401 neonates were screened using transient evoked otoacoustic emissions (TEOAE) followed by second-stage screening of those infants who failed the initial test. Eight (2 per cent) infants failed one ear and 23 (5.74 per cent) infants failed both ears, adding up to 7.74 per cent planned for second-stage screening. Five out of 22 infants who came for the follow up failed the screening, resulting in a prevalence of hearing impairment of 1 per cent (95 per cent confidence interval [95% CI]: 0.0-2.0). Craniofacial malformations, very low birth weight, ototoxic medication, stigmata/syndromes associated with hearing loss and hyperbilirubinaemia at the level of exchange tranfusion were identified to be independent significant risk factors for hearing impairment, while poor Apgar scores and mechanical ventilation of more than five days were not. In conclusion, hearing screening in high-risk neonates revealed a total of 1 per cent with hearing loss. The changes in the risk profile indicate improved perinatal handling in a neonatal population at risk for hearing disorders.
    Matched MeSH terms: Neonatal Screening/methods*
  16. Jawin V, Ang HL, Omar A, Thong MK
    PLoS One, 2015;10(9):e0137580.
    PMID: 26360420 DOI: 10.1371/journal.pone.0137580
    Studies on pulse oximetry screening for neonatal sepsis and respiratory disease in a middle-income country are lacking. Newborn screening for critical congenital heart disease (CCHD) using pulse oximetry is an effective and life-saving strategy in developed countries. While most studies have reported false-positive results during CCHD screening, they have not elaborated on the detected disease types. We studied the effectiveness and outcomes of pulse oximetry newborn screening for non-cardiac hypoxemic diseases such as neonatal sepsis, respiratory diseases, and CCHD in a middle-income country.
    Matched MeSH terms: Neonatal Screening*