Displaying all 18 publications

Abstract:
Sort:
  1. Taniselass S, Arshad MKM, Gopinath SCB, Ramli MM
    J Colloid Interface Sci, 2020 Oct 01;577:345-354.
    PMID: 32485416 DOI: 10.1016/j.jcis.2020.05.070
    Reduced graphene oxide (rGO) is widely utilised to develop various types of biosensors; however, producing self-assembled rGO nanoflake networks through single-droplet drop-casting remains inconsistent. In the present work, we systematically used three different methods to prepare rGO suspensions in order to produce large scale self-assembled rGO nanoflake networks through single-droplet drop-casting. The rGO suspensions were prepared using only deionised water with no added any chemicals/organic solvents, which we considered to be a low-cost method. Subsequently, the most effective preparation method was used to deposit rGO nanoflakes onto commercial gold interdigitated microelectrodes (Au-IDE) to examine their electrical performance. Assessment of the yields, developed methods, surface morphologies, spectroscopy and structural analyses of the as-prepared rGO nanoflakes were conducted. The results revealed that method-3 (involving sonication, centrifugation and post-sonication) produced large self-assembled rGO nanoflake networks with strong adhesion to glass substrates. Furthermore, the as-prepared rGO/Au-IDE modified sensors showed excellent electron mobility where the electrical conductivity was enhanced approximately ~ 1000 fold compared to the bare devices. The present work provided new insights for depositing large self-assembled interconnected rGO nanoflake networks through single-droplet drop-casting which will be beneficial for biosensor development and other downstream applications.
    Matched MeSH terms: Microelectrodes
  2. Zurina Zainal Abidin, Zalini Yunus, Markx, Gerard H.
    MyJurnal
    The dielectrophoretic (DEP) separation of cell, using microelectrodes structure, has been limited to small scale due to size of the substrate. This work was carried out to extend the capability of microelectrodes system by orientating the microelectrodes in three dimensions (3-D) for larger scale dielectrophoretic separation of microorganism. The designed 3-D separation chamber consists of microelectrodes on two opposing walls. Based on the FEMLAB simulation, the electric field was seen to be generated across the chamber, rather than between adjacent electrodes in the same plane like in the small scale system. This configuration led to a stronger electric field in the bulk medium. The experimental results showed that the 3-D microelectrodes chamber behaved similar to the system with microelectrodes on one wall. The effects of the main parameters such as voltage, frequency and flow rates were similar to that of the systems with all the electrodes on one wall, but on the overall, capture more cells. A gap size between 250 – 500 μm resulted in an electric field which is strong enough to hold cells while giving a reasonable cross sectional area at the same time. Although there is some improvement achieved by 3-D system, it is still not very much, as compared to the small scale system.
    Matched MeSH terms: Microelectrodes
  3. Buyong MR, Larki F, Faiz MS, Hamzah AA, Yunas J, Majlis BY
    Sensors (Basel), 2015;15(5):10973-90.
    PMID: 25970255 DOI: 10.3390/s150510973
    In this work, the dielectrophoretic force (F(DEP)) response of Aluminium Microelectrode Arrays with tapered profile is investigated through experimental measurements and numerical simulations. A standard CMOS processing technique with a step for the formation of a tapered profile resist is implemented in the fabrication of Tapered Aluminium Microelectrode Arrays (TAMA). The F(DEP) is investigated through analysis of the Clausius-Mossotti factor (CMF) and cross-over frequency (f(xo)). The performance of TAMA with various side wall angles is compared to that of microelectrodes with a straight cut sidewall profile over a wide range of frequencies through FEM numerical simulations. Additionally, electric field measurement (EFM) is performed through scanning probe microscopy (SPM) in order to obtain the region of force focus in both platforms. Results showed that the tapered profile microelectrodes with angles between 60° and 70° produce the highest electric field gradient on the particles. Also, the region of the strongest electric field in TAMA is located at the bottom and top edge of microelectrode while the strongest electric field in microelectrodes with straight cut profile is found at the top corner of the microelectrode. The latter property of microelectrodes improves the probability of capturing/repelling the particles at the microelectrode's side wall.
    Matched MeSH terms: Microelectrodes
  4. Rashid NFA, Deivasigamani R, Wee MFMR, Hamzah AA, Buyong MR
    Sensors (Basel), 2021 Jul 21;21(15).
    PMID: 34372193 DOI: 10.3390/s21154957
    We present the integration of a flow focusing microfluidic device in a dielectrophoretic application that based on a tapered aluminum microelectrode array (TAMA). The characterization and optimization method of microfluidic geometry performs the hydrodynamic flow focusing on the channel. The sample fluids are hydrodynamically focused into the region of interest (ROI) where the dielectrophoresis force (FDEP) is dominant. The device geometry is designed using 3D CAD software and fabricated using the micro-milling process combined with soft lithography using PDMS. The flow simulation is achieved using COMSOL Multiphysics 5.5 to study the effect of the flow rate ratio between the sample fluids (Q1) and the sheath fluids (Q2) toward the width of flow focusing. Five different flow rate ratios (Q1/Q2) are recorded in this experiment, which are 0.2, 0.4, 0.6, 0.8 and 1.0. The width of flow focusing is increased linearly with the flow rate ratio (Q1/Q2) for both the simulation and the experiment. At the highest flow rate ratio (Q1/Q2 = 1), the width of flow focusing is obtained at 638.66 µm and at the lowest flow rate ratio (Q1/Q2 = 0.2), the width of flow focusing is obtained at 226.03 µm. As a result, the flow focusing effect is able to reduce the dispersion of the particles in the microelectrode from 2000 µm to 226.03 µm toward the ROI. The significance of flow focusing on the separation of particles is studied using 10 and 1 µm polystyrene beads by applying a non-uniform electrical field to the TAMA at 10 VPP, 150 kHz. Ultimately, we are able to manipulate the trajectories of two different types of particles in the channel. For further validation, the focusing of 3.2 µm polystyrene beads within the dominant FDEP results in an enhanced manipulation efficiency from 20% to 80% in the ROI.
    Matched MeSH terms: Microelectrodes
  5. Ibau C, Md Arshad MK, Gopinath SCB, Nuzaihan M N M, M Fathil MF, Estrela P
    Biosens Bioelectron, 2019 Jul 01;136:118-127.
    PMID: 31054519 DOI: 10.1016/j.bios.2019.04.048
    A simple, single-masked gold interdigitated triple-microelectrodes biosensor is presented by taking the advantage of an effective self-assembled monolayer (SAM) using an amino-silanization technique for the early detection of a prostate cancer's biomarker, the prostate-specific antigen (PSA). Unlike most interdigitated electrode biosensors, biorecognition happens in between the interdigitated electrodes, which enhances the sensitivity and limit of detection of the sensor. Using the Faradaic mode electrochemical impedance spectroscopy (EIS) technique to quantify the PSA antigen, the developed sensing platform demonstrates a logarithmic detection of PSA ranging from 0.5 ng/ml to 5000 ng/ml, an estimated LOD down to 0.51 ng/ml in the serum, and a good sensor's reproducibility. The sensor's detection range covers the clinical threshold value at 4 ng/ml and the crucial diagnosis 'grey zone' of 4-10 ng/ml of PSA in serum for an accurate cancer diagnosis. The selectivity test revealed an excellent discrimination of other competing proteins, with a recorded detection signals at 5 ng/ml PSA as high as 7-fold increase versus the human serum albumin (HSA) and 8-fold increase versus the human glandular kallikrein 2 (hK2). The stability test showed an acceptable stability of the aptasensor recorded at six (6) days before the detection signal started degrading below 10% of the peak detection value. The developed sensing scheme is proven to exhibit a great potential as a portable prostate cancer biosensor, also as a universal platform for bio-molecular sensing with the versatility to implement nanoparticles and other surface chemistry for various applications.
    Matched MeSH terms: Microelectrodes*
  6. Yafouz B, Kadri NA, Ibrahim F
    Sensors (Basel), 2013 Jul 12;13(7):9029-46.
    PMID: 23857266 DOI: 10.3390/s130709029
    During the last three decades; dielectrophoresis (DEP) has become a vital tool for cell manipulation and characterization due to its non-invasiveness. It is very useful in the trend towards point-of-care systems. Currently, most efforts are focused on using DEP in biomedical applications, such as the spatial manipulation of cells, the selective separation or enrichment of target cells, high-throughput molecular screening, biosensors and immunoassays. A significant amount of research on DEP has produced a wide range of microelectrode configurations. In this paper; we describe the microarray dot electrode, a promising electrode geometry to characterize and manipulate cells via DEP. The advantages offered by this type of microelectrode are also reviewed. The protocol for fabricating planar microelectrodes using photolithography is documented to demonstrate the fast and cost-effective fabrication process. Additionally; different state-of-the-art Lab-on-a-Chip (LOC) devices that have been proposed for DEP applications in the literature are reviewed. We also present our recently designed LOC device, which uses an improved microarray dot electrode configuration to address the challenges facing other devices. This type of LOC system has the capability to boost the implementation of DEP technology in practical settings such as clinical cell sorting, infection diagnosis, and enrichment of particle populations for drug development.
    Matched MeSH terms: Microelectrodes*
  7. Yunus, N.A.M., Jaafar, H., Halin, I.A., Green, N.G.
    ASM Science Journal, 2014;8(1):29-35.
    MyJurnal
    This paper presents a suitable and unique system for observing dielectrophoretic particle separation in a microfluidic device. Details presented on the experimental setup used will enable real time examination, monitoring and analysis of carboxylate-modified latex sphere particles in a colloidal mixture. Observations of the particles were made possible through an optical setup that illuminates the particles that went through the microelectrode array in the microchannel that was controlled by two analog signal generators. Through the setup, it was easily observed that the latex sphere particles move at a flow rate of 0.2 μl/s without colliding or overlapping on each other and successfully separated in two bands left and right. The new separation of one finest particles size for finest purification with respect to frequency was also observed, obtained and analysed.
    Matched MeSH terms: Microelectrodes
  8. Li X, Gopinath SCB, Peng X, Lv J
    J Biomed Nanotechnol, 2021 Dec 01;17(12):2495-2504.
    PMID: 34974872 DOI: 10.1166/jbn.2021.3213
    An aptasensor was developed on an interdigitated microelectrode (IDME) by current-volt sensing for the diagnosis of ulcerative colitis by detecting the biomarker lipocalin-2. Higher immobilization of the anti-lipocalin-2 aptamer as a probe was achieved by using sodium dodecyl benzenesulfonate-aided zeolite particles. FESEM and FETEM observations revealed that the size of the zeolite particles was <200 nm, and they displayed a uniform distribution and spherical shape. XPS analysis attested the occurrence of Si, Al, and O groups on the zeolite particles. Zeolite particles were immobilized on IDME by a (3-aminopropyl)-trimethoxysilane amine linker, and then, the aptamer as the probe was tethered on the zeolite particles through a biotin-streptavidin strategy assisted by a bifunctional aldehyde linker. Due to the high occupancy of the aptamer and the efficient electric transfer from zeolite particles, higher changes in current can be observed upon interaction of the aptamer with lipocalin-2. The lower detection of lipocalin-2 was noted as 10 pg/mL, with a linear range from 10 pg/mL to 1 μg/mL and a linear regression equation of y=8E-07x+8E-08; R² = 0.991. Control experiments with complementary aptamer and matrix metalloproteinase-9 indicate the specific detection of lipocalin-2. Furthermore, spiking lipocalin-2 in human serum does not interfere with the identification.
    Matched MeSH terms: Microelectrodes
  9. Ahmad F, Christenson A, Bainbridge M, Yusof AP, Ab Ghani S
    Biosens Bioelectron, 2007 Mar 15;22(8):1625-32.
    PMID: 16934449
    A new implantable electrocatalytic glucose sensor for subcutaneous glucose monitoring has been fabricated by immobilizing glucose oxidase on a chemically modified carbon fiber. The sensor was inserted subcutaneously on a male spraguely rat without any incision after dipping the microsensor in the rat's serum for 3 days. The so called "stained" microsensor, operated in the amperometric mode with an applied potential of +0.23 V versus Ag|AgCl, was able to directly measure the glucose concentration upon infusion of glucose. The results obtained were encouraging, with the response time was less than 2s and the apparent Michaelis-Menten value at 5.1+/-0.5mM. The "stained" microsensor shows good stability and reproducibility with constant response spanned over 25 days. Most common interferences in glucose analysis were minimized by the outerlayer Nafion. Hematology examinations showed minimal material-tissue interaction. Use of such mechanical devices will allow a more refined understanding towards glucose control in diabetic patients as the implanted microsensor was not effected by biocompatibility failures.
    Matched MeSH terms: Microelectrodes
  10. Yunus NA, Nili H, Green NG
    Electrophoresis, 2013 Apr;34(7):969-78.
    PMID: 23436439 DOI: 10.1002/elps.201200466
    Dielectrophoresis is the movement of particles in nonuniform electric fields and has been of interest for application to manipulation and separation at and below the microscale. This technique has the advantages of being noninvasive, nondestructive, and noncontact, with the movement of particle achieved by means of electric fields generated by miniaturized electrodes and microfluidic systems. Although the majority of applications have been above the microscale, there is increasing interest in application to colloidal particles around a micron and smaller. This paper begins with a review of colloidal and nanoscale dielectrophoresis with specific attention paid to separation applications. An innovative design of integrated microelectrode array and its application to flow-through, continuous separation of colloidal particles is then presented. The details of the angled chevron microelectrode array and the test microfluidic system are then discussed. The variation in device operation with applied signal voltage is presented and discussed in terms of separation efficiency, demonstrating 99.9% separation of a mixture of colloidal latex spheres.
    Matched MeSH terms: Microelectrodes
  11. Ibau C, Arshad MKM, Gopinath SCB, Nuzaihan M N M, Fathil MFM, Shamsuddin SA
    Int J Biol Macromol, 2020 Nov 01;162:1924-1936.
    PMID: 32822729 DOI: 10.1016/j.ijbiomac.2020.08.125
    This work explores Electrochemical Impedance Spectroscopy (EIS) detection for a highly-sensitive quantification of prostate-specific antigen (PSA) in Faradaic (f-EIS) and non-Faradaic modes (nf-EIS). Immobilization of monoclonal antibody specific to PSA (anti-PSA) was performed using 1-ethyl-3-dimethylaminopropylcarbodiimide hydrochloride and N-hydroxysuccinimide crosslinking agents in order to conjugate carboxylic (-COOH) terminated group of 16-Mercaptoundecanoic acid with amine (-NH3+) on anti-PSA epitope. This approach offers simple and efficient approach to form a strong, covalently bound thiol-gold (SAu) for a reliable SAM layer formation. Studies on the topographic of pristine Au-IDE surface were performed by Scanning Electron Microscopy and Energy Dispersive X-ray Spectroscopy techniques, meanwhile a 3-dimensional optical surface profiler, Atomic Force Microscopy and X-ray Photoelectron Spectroscopy techniques were used to validate the successful functionalization steps on the sensor transducer surface. Detection of PSA in f-EIS mode was carried out by measuring the response in charge transfer resistance (Rct) and impedance change (Z), meanwhile in nf-EIS mode, the changes in device capacitance was monitored. In f-EIS mode, the sensor reveals a logarithmic detection of PSA in a range of 100 ng/ml down to 0.01 ng/ml in Phosphate Buffered Saline with a recorded sensitivity of 2.412 kΩ/log10 ([PSA] ng/ml) and the limit of detection (LOD) down to 0.01 ng/ml. The nf-EIS detection mode yields a logarithmic detection range of 5000 ng/ml down to 0.5 ng/ml, with a sensitivity of 8.570 nF/log10 ([PSA] ng/ml) and an LOD of 0.5 ng/ml. The developed bio-assay yields great device stability, specificity to PSA and repeatability of detection that would pave its way for the future development into portable lab-on-chip bio-sensing system.
    Matched MeSH terms: Microelectrodes
  12. Chan JY, Ahmad Kayani AB, Md Ali MA, Kok CK, Ramdzan Buyong M, Hoe SLL, et al.
    Electrophoresis, 2019 10;40(20):2728-2735.
    PMID: 31219180 DOI: 10.1002/elps.201800442
    This paper presents the development and experimental analysis of a curved microelectrode platform for the DEP deformation of breast cancer cells (MDA-MB-231). The platform is composed of arrays of curved DEP microelectrodes which are patterned onto a glass slide and samples containing MDA-MB-231 cells are pipetted onto the platform's surface. Finite element method is utilised to characterise the electric field gradient and DEP field. The performance of the system is assessed with MDA-MB-231 cells in a low conductivity 1% DMEM suspending medium. We applied sinusoidal wave AC potential at peak to peak voltages of 2, 5, and 10 Vpp at both 10 kHz and 50 MHz. We observed cell blebbing and cell shrinkage and analyzed the percentage of shrinkage of the cells. The experiments demonstrated higher percentage of cell shrinkage when cells are exposed to higher frequency and peak to peak voltage electric field.
    Matched MeSH terms: Microelectrodes
  13. Taniselass S, Arshad MKM, Gopinath SCB, Fathil MFM, Ibau C, Anbu P
    Mikrochim Acta, 2021 07 15;188(8):257.
    PMID: 34268634 DOI: 10.1007/s00604-021-04922-x
    A label-free chemical bonding strategy mediated by reduced graphene oxide (rGO) basal plane functional groups has been developed for cardiac Troponin I (cTnI) detection. Four different chemical strategies on respective electrode sensing surface were precedingly examined using electrochemical impedance spectroscopy. The impedimetric assessment was carried out by sweeping frequency at the range 0.1-500 kHz perturbated at a small amplitude of AC voltage (25 mV). The chemical strategy-4 denoted as S-4 shows a significant analytical performance on cTnI detection in spiked buffer and human serum, whereby the pre-mixture of rGO and (3-Aminopropyl)triethoxysilane (APTES) creates a large number of amine sites (-NH2), which significantly enhanced the antibody immobilization without excessive functionalization. The as-fabricated immunosensor exhibited an ultra-low limit of detection of 6.3 ag mL-1 and the lowest antigen concentration measured was at 10 ag mL-1. The immunosensor showed a linear and wide range of cTnI detection (10 ag mL-1-100 ng mL-1) in human serum with a regression coefficient of 0.9716, rapid detection (5 min of binding time), and stable and highly reproducible bioelectrode response with RSD 
    Matched MeSH terms: Microelectrodes
  14. Mok SY, Lim YM, Goh SY
    J Neurosci Methods, 2009 May 15;179(2):284-91.
    PMID: 19428539 DOI: 10.1016/j.jneumeth.2009.02.009
    A device to facilitate high-density seeding of dissociated neural cells on planar multi-electrode arrays (MEAs) is presented in this paper. The device comprises a metal cover with two concentric cylinders-the outer cylinder fits tightly on to the external diameter of a MEA to hold it in place and an inner cylinder holds a central glass tube for introducing a cell suspension over the electrode area of the MEA. An O-ring is placed at the bottom of the inner cylinder and the glass tube to provide a fluid-tight seal between the glass tube and the MEA electrode surface. The volume of cell suspension in the glass tube is varied according to the desired plating density. After plating, the device can be lifted from the MEA without leaving any residue on the contact surface. The device has enabled us to increase and control the plating density of neural cell suspension with low viability, and to prepare successful primary cultures from cryopreserved neurons and glia. The cultures of cryopreserved dissociated cortical neurons that we have grown in this manner remained spontaneously active over months, exhibited stable development and similar network characteristics as reported by other researchers.
    Matched MeSH terms: Microelectrodes
  15. Zhou D, Gopinath SCB, Mohamed Saheed MS, Siva Sangu S, Lakshmipriya T
    Int J Nanomedicine, 2020;15:10171-10181.
    PMID: 33363373 DOI: 10.2147/IJN.S284752
    Background: In recent years, nanomaterials have justified their dissemination for biosensor application towards the sensitive and selective detections of clinical biomarkers at the lower levels. MXene is a two-dimensional layered transition metal, attractive for biosensing due to its chemical, physical and electrical properties along with the biocompatibility.

    Materials and Methods: This work was focused on diagnosing osteosarcoma (OS), a common bone cancer, on MXene-modified multiple junction triangles by dielectrode sensing. Survivin protein gene is highly correlated with OS, identified on this sensing surface. Capture DNA was immobilized on MXene by using 3-glycidoxypropyltrimethoxysilane as an amine linker and duplexed by the target DNA sequence.

    Results: The limitation and sensitivity of detection were found as 1 fM with the acceptable regression co-efficient value (y=1.0037⨰ + 0.525; R2=0.978) and the current enhancement was noted when increasing the target DNA concentrations. Moreover, the control sequences of single- and triple-mismatched and noncomplementary to the target DNA sequences failed to hybridize on the capture DNA, confirming the specificity. In addition, different batches were prepared with capture probe immobilized sensing surfaces and proved the efficient reproducibility.

    Conclusion: This microgap device with Mxene-modified multiple junction triangles dielectrode surface is beneficial to quantify the survivin gene at its lower level and diagnosing OS complication levels.

    Matched MeSH terms: Microelectrodes
  16. Yan G, Li Q, Hong X, Gopinath SCB, Anbu P, Li C, et al.
    Mikrochim Acta, 2021 05 11;188(6):185.
    PMID: 33977395 DOI: 10.1007/s00604-021-04836-8
    An abdominal aortic aneurysm (AAA) is abnormal swelling in the abdominal aorta and a prevalent life-threatening disease. This research introduces a new interdigitated microelectrode (IDME)-sensing surface modified by iron oxide nanoworms (IONWs) for detecting the AAA biomarker insulin-like growth factor-1 (IGF1). A sandwich pattern was formulated with the IGF1 aptamer and IGFBP1 (IGF binding protein-1) on the IONW-constructed IDME hybrid to identify IGF1. The surface morphology of the IONWs revealed a uniform distribution of worm-like structures (80-100 nm) as confirmed by FESEM and FETEM analyses. Further, the presence of the major elements, Fe and O, was confirmed by EDX and XPS studies. The crystal planes that appeared in the IONW reflect cubic magnetite. IONW-modified IDME attained a limit of detection for IGF1 of 1 fM (3σ) with an aptamer-IGF1-IGFBP1 sandwich. This sandwich with IGFBP1 enhanced the current level at all concentrations of IGF1 and displayed linearity in the range 1 fM to 100 pM with a determination coefficient of R2 = 0.9373 [y = 3.38221x - 4.79]. Control experiments with complementary aptamer sequences, IGF2 and IGFBP3 did not show notable signal changes, indicating the specific detection of IGF1. This IONW constructed electrode helps to achieve the detection of low amounts of IGF1 and diagnose AAA at the stage prior to rupture.
    Matched MeSH terms: Microelectrodes
  17. Valli H, Ahmad S, Sriharan S, Dean LD, Grace AA, Jeevaratnam K, et al.
    Clin Exp Pharmacol Physiol, 2018 03;45(3):278-292.
    PMID: 29027245 DOI: 10.1111/1440-1681.12870
    Acute RyR2 activation by exchange protein directly activated by cAMP (Epac) reversibly perturbs myocyte Ca2+ homeostasis, slows myocardial action potential conduction, and exerts pro-arrhythmic effects. Loose patch-clamp studies, preserving in vivo extracellular and intracellular conditions, investigated Na+ current in intact cardiomyocytes in murine atrial and ventricular preparations following Epac activation. Depolarising steps to varying test voltages activated typical voltage-dependent Na+ currents. Plots of peak current against depolarisation from resting potential gave pretreatment maximum atrial and ventricular currents of -20.23 ± 1.48 (17) and -29.8 ± 2.4 (10) pA/μm2 (mean ± SEM [n]). Challenge by 8-CPT (1 μmol/L) reduced these currents to -11.21 ± 0.91 (12) (P  .05). Assessment of the inactivation that followed by applying subsequent steps to a fixed voltage 100 mV positive to resting potential gave concordant results. Half-maximal inactivation voltages and steepness factors, and time constants for Na+ current recovery from inactivation in double-pulse experiments, were similar through all the pharmacological conditions. Intracellular sharp microelectrode membrane potential recordings in intact Langendorff-perfused preparations demonstrated concordant variations in maximum rates of atrial and ventricular action potential upstroke, (dV/dt)max . We thus demonstrate an acute, reversible, Na+ channel inhibition offering a possible mechanism for previously reported pro-arrhythmic slowing of AP propagation following modifications of Ca2+ homeostasis, complementing earlier findings from chronic alterations in Ca2+ homeostasis in genetically-modified RyR2-P2328S hearts.
    Matched MeSH terms: Microelectrodes
  18. Liu Z, Gopinath SCB, Wang Z, Li Y, Anbu P, Zhang W
    Mikrochim Acta, 2021 05 15;188(6):187.
    PMID: 33990848 DOI: 10.1007/s00604-021-04834-w
    A new zeolite-iron oxide nanocomposite (ZEO-IO) was extracted from waste fly ash of a thermal power plant and utilized for capturing aptamers used to quantify the myocardial infarction (MI) biomarker N-terminal prohormone B-type natriuretic peptide (NT-ProBNP); this was used in a probe with an integrated microelectrode sensor. High-resolution microscopy revealed that ZEO-IO displayed a clubbell structure and a particle size range of 100-200 nm. Energy-dispersive X-ray spectroscopy and X-ray photoelectron spectroscopy confirmed the presence of Si, Al, Fe, and O in the synthesized ZEO-IO. The limit of detection for NT-ProBNP was 1-2 pg/mL (0.1-0.2 pM) when the aptamer was sandwiched with antibody and showed the doubled current response even at a low NT-ProBNP abundance. A dose-dependent interaction was identified for this sandwich with a linear plot in the concentration range 1 to 32 pg/mL (0.1-3.2 pM) with a determination coefficient R2 = 0.9884; y = 0.8425x-0.5771. Without  sandwich, the detection limit was 2-4 pg/mL (0.2-0.4 pM) and the determination coefficient was R2 = 0.9854; y = 1.0996x-1.4729. Stability and nonfouling assays in the presence of bovine serum albumin, cardiac troponin I, and myoglobin revealed that the aptamer-modified surface is stable and specific for NT-Pro-BNP. Moreover, NT-ProBNP-spiked human serum exhibited selective detection. This new nanocomposite-modified surface helps in detecting NT-Pro-BNP and diagnosing MI at stages of low expression.
    Matched MeSH terms: Microelectrodes
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links