Displaying all 10 publications

Abstract:
Sort:
  1. Sil BK, Jamiruddin MR, Haq MA, Khondoker MU, Jahan N, Khandker SS, et al.
    Int J Nanomedicine, 2021;16:4739-4753.
    PMID: 34267520 DOI: 10.2147/IJN.S313140
    BACKGROUND: Serological tests detecting severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) are widely used in seroprevalence studies and evaluating the efficacy of the vaccination program. Some of the widely used serological testing techniques are enzyme-linked immune-sorbent assay (ELISA), chemiluminescence immunoassay (CLIA), and lateral flow immunoassay (LFIA). However, these tests are plagued with low sensitivity or specificity, time-consuming, labor-intensive, and expensive. We developed a serological test implementing flow-through dot-blot assay (FT-DBA) for SARS-CoV-2 specific IgG detection, which provides enhanced sensitivity and specificity while being quick to perform and easy to use.

    METHODS: SARS-CoV-2 antigens were immobilized on nitrocellulose membrane to capture human IgG, which was then detected with anti-human IgG conjugated gold nanoparticle (hIgG-AuNP). A total of 181 samples were analyzed in-house. Within which 35 were further evaluated in US FDA-approved CLIA Elecsys SARS-CoV-2 assay. The positive panel consisted of RT-qPCR positive samples from patients with both <14 days and >14 days from the onset of clinical symptoms. The negative panel contained samples collected from the pre-pandemic era dengue patients and healthy donors during the pandemic. Moreover, the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of FT-DBA were evaluated against RT-qPCR positive sera. However, the overall efficacies were assessed with sera that seroconverted against either nucleocapsid (NCP) or receptor-binding domain (RBD).

    RESULTS: In-house ELISA selected a total of 81 true seropositive and 100 seronegative samples. The sensitivity of samples with <14 days using FT-DBA was 94.7%, increasing to 100% for samples >14 days. The overall detection sensitivity and specificity were 98.8% and 98%, respectively, whereas the overall PPV and NPV were 99.6% and 99%. Moreover, comparative analysis between in-house ELISA assays and FT-DBA revealed clinical agreement of Cohen's Kappa value of 0.944. The FT-DBA showed sensitivity and specificity of 100% when compared with commercial CLIA kits.

    CONCLUSION: The assay can confirm past SARS-CoV-2 infection with high accuracy within 2 minutes compared to commercial CLIA or in-house ELISA. It can help track SARS-CoV-2 disease progression, population screening, and vaccination response. The ease of use of the assay without requiring any instruments while being semi-quantitative provides the avenue of its implementation in remote areas around the globe, where conventional serodiagnosis is not feasible.

    Matched MeSH terms: Immunoblotting/methods*
  2. Eamsobhana P, Gan XX, Ma A, Wang Y, Wanachiwanawin D, Yong HS
    J Helminthol, 2014 Dec;88(4):396-401.
    PMID: 23710755 DOI: 10.1017/S0022149X13000321
    A rapid dot immunogold filtration assay (DIGFA) was adopted for specific immunodiagnosis of human cerebral angiostrongyliasis, using purified 31-kDa glycoprotein specific to Angiostrongylus cantonensis as diagnostic antigen and protein A colloidal gold conjugate as antigen-antibody detector. A total of 59 serum samples were assayed - 11 samples from clinically diagnosed patients with detectable A. cantonensis-specific antibody in immunoblotting; 23 samples from patients with other related parasitic diseases, i.e. gnathostomiasis (n= 8), cysticercosis (n= 5), toxocariasis (n= 2), filariasis (n= 4), paragonimiasis (n= 2) and malaria (n= 2); and 25 samples from normal healthy subjects. The sensitivity and specificity of DIGFA to detect anti-A. cantonensis specific antibodies in serologically confirmed angiostrongyliasis cases, were both 100%. No positive DIGFA was observed in cases with other parasitic diseases, and the healthy control subjects. The 3-min DIGFA is as sensitive and specific as the 3-h immunoblot test in angiostrongyliasis confirmed cases that revealed a 31-kDa reactive band. The gold-based DIGFA is more rapid and easier to perform than the traditional enzyme-linked immunosorbent assay (ELISA). The test utilizing purified A. cantonensis antigen is reliable and reproducible for specific immunodiagnosis of human infection with A. cantonensis - thus can be applied as an additional routine test for clinical diagnostic support. Large-scale sero-epidemiological studies in endemic communities in north-east Thailand are under way to evaluate its usefulness under field conditions.
    Matched MeSH terms: Immunoblotting/methods*
  3. Lee TC, Yusoff K, Nathan S, Tan WS
    J Virol Methods, 2006 Sep;136(1-2):224-9.
    PMID: 16797732
    Newcastle disease virus (NDV) strains can be classified as virulent or avirulent based upon the severity of the disease. Differentiation of the virus into virulent and avirulent is necessary for effective control of the disease. Biopanning experiments were performed using a disulfide constrained phage displayed heptapeptide library against three pathotypes of NDV strains: velogenic (highly virulent), mesogenic (moderately virulent) and lentogenic (avirulent). A phage clone bearing the peptide sequence SWGEYDM capable of distinguishing virulent from avirulent NDV strains was isolated. This phage clone was employed as a diagnostic reagent in a dot blot assay and it successfully detected only virulent NDV strains.
    Matched MeSH terms: Immunoblotting/methods*
  4. Koay AS, Tay ST, Cheong YM, Yasin RM
    PMID: 8629074
    An IgM dot-immunobinding assay (IgM-DIA) was developed for the diagnosis of scrub typhus infection. The whole cell antigens of Karp, Kato and Gilliam strains of Rickettsia tsutsugamushi were immobilized onto nitrocellulose paper and reacted with patients sera. The presence of IgM R. tsutsugamushi specific antibody in the patient sera could be detected by the observation of a visible brown dot on the nitrocellulose paper. The IgM-DIA has a sensitivity of 90.4% and specificity of 81.4% as compared to the indirect immunoperoxidase test. The IgM-DIA is rapid, simple, cost-effective, does not require microscope or incubator. It is recommended as a rapid screening test for the diagnosis of scrub typhus infection in the field or rural area within the hyperendemic region.
    Matched MeSH terms: Immunoblotting/methods*
  5. Ong EB, Anthony AA, Ismail A, Ismail A, Lim TS
    Diagn Microbiol Infect Dis, 2013 Sep;77(1):87-9.
    PMID: 23790417 DOI: 10.1016/j.diagmicrobio.2013.05.010
    The hemolysin (HlyE) protein of Salmonella enterica serovar Typhi was reported to be antigenic. This work describes the cloning, expression, and purification of a hexahistidine-tagged HlyE protein under native conditions. Immunoblot analysis and a competitive enzyme-linked immunosorbent assay using sera from typhoid patients showed the presence of HlyE-specific antibodies in circulation.
    Matched MeSH terms: Immunoblotting/methods
  6. Weddle JR, Chan TC, Thompson K, Paxton H, Kelly DJ, Dasch G, et al.
    Am J Trop Med Hyg, 1995 Jul;53(1):43-6.
    PMID: 7625532
    We compared a commercially available dot-blot immunoassay system with the indirect immunofluorescence assay (IFA) in tests of known negative and known positive sera from scrub typhus cases. Using a panel of 100 sera from patients with various rickettsial and nonrickettsial infections, we observed that the IFA was 99% specific and the dipstick assay was 98% specific. In tests of 91 sera (30 negative and 61 positive for scrub typhus antibodies) from a study of febrile patients in Malaysia, using the standard of an IFA titer < 1:64 as negative, an IFA titer > 1:128 as positive, and an IFA titer = 1:64 as either positive or negative (supported by clinical records), dipsticks were 83% specific and 90% sensitive. The quantitative correlation of the dipsticks to IFA titers was confirmed by significant differences in geometric means of inverse IFA titers corresponding to the number of positive dipstick spots (no dots = 8.5, one dot = 43.3, two dots = 206.7, and three dots = 676.9). The assay would enable physicians and public health workers who deal with patients to quickly diagnose and appropriately treat most cases of the disease, especially in areas of high prevalence where the proportion of false-positive results to true-positive results would be low.
    Matched MeSH terms: Immunoblotting/methods*
  7. Kotresha D, Poonam D, Muhammad Hafiznur Y, Saadatnia G, Nurulhasanah O, Sabariah O, et al.
    Trop Biomed, 2012 Mar;29(1):129-37.
    PMID: 22543613 MyJurnal
    In this study we have cloned unreported gene fragments of Toxoplasma gondii GRA7 and SAG1 and expressed the corresponding recombinant proteins, followed by evaluation of their usefulness for the serological diagnosis of toxoplasmosis. Both recombinant proteins were expressed efficiently in insoluble form, purified by single step Ni-NTA affinity chromatography and their antigenicity to detect toxoplasma specific IgG antibodies were determined by immunoblotting. A total of 60 serum samples from three groups of individuals based on their anti-toxoplasma antibody profiles were tested, namely (I) IgM+, IgG+ (n=20), (II) IgM-, IgG+ (n=20) and (III) IgM-, IgG- (n=20). Both recombinant proteins exhibited high sensitivity (100%) with sera from Group I. rGRA7 and rSAG1 reacted 40% and 80% respectively with Group II sera. The specificity of the recombinant proteins based on reactivities with Group III sera were 100% and 80% with rGRA7 and rSAG1 respectively. Thus rGRA7 was found to be better at discriminating probable acute from chronic phases of toxoplasmosis, and it also showed higher specificity.
    Matched MeSH terms: Immunoblotting/methods
  8. Henry Sum MS, Yee SF, Eng L, Poili E, Lamdin J
    Biomed Res Int, 2017;2017:3608042.
    PMID: 29201901 DOI: 10.1155/2017/3608042
    Rice tungro disease (RTD) is one of the most destructive diseases of rice in South and Southeast Asia. RTD is routinely detected based on visual observation of the plant. However, it is not always easy to identify the disease in the field as it is often confused with other diseases or physiological disorders. Here we report the development of two serological based assays for ease of detection of RTD. In this study we had developed and optimized an indirect ELISA and dot-blot assay for detection of RTD. The efficiency of both assays was evaluated by comparing the specificity and sensitivity of the assays to PCR assay using established primer sets. The indirect ELISA showed 97.5% and 96.6%, while the dot-blot assay showed 97.5% and 86.4% sensitivity and specificity, respectively, when compared to established PCR method. The high sensitivity and specificity of the two assays merit the use of both assays as alternative methods to diagnose RTD. Furthermore, the dot-blot assay is a simple, robust, and rapid diagnostic assay that is suitable for field test for it does not require any specialized equipment. This is a great advantage for diagnosing RTD in paddy fields, especially in the rural areas.
    Matched MeSH terms: Immunoblotting/methods*
  9. Eamsobhana P, Yong HS, Mak JW, Wattanakulpanich D
    PMID: 9561620
    A dot-blot ELISA was compared with a previously performed sandwich ELISA for the detection of Parastrongylus cantonensis antigens in sera from patients. Using the same monoclonal antibody and the same sera, 6 of 10 sera (60%) from parastronglyiasis patients were positive in dot-blot ELISA, whereas with sandwich ELISA, 5 of the same patient sera (50%) were positive. The specificity in both assays was 100% using 50 sera from patients with other parasitic diseases; of these, 10 each were from patients with cysticercosis, filariasis, gnathostomiasis, malaria and toxocariasis. The control group consisted of 53 sera from normal health Thais and Malaysians. The sensitivity of the assays was, however, slightly better with dot-blot ELISA and because it is simple, quick and cost-effective, it may be a test of choice for specific diagnosis of human parastrongyliasis.
    Matched MeSH terms: Immunoblotting/methods*
  10. Palaeya V, Lau YL, Mahmud R, Chen Y, Fong MY
    Malar J, 2013;12:182.
    PMID: 23734702 DOI: 10.1186/1475-2875-12-182
    Plasmodium knowlesi is the fifth species identified to cause malaria in humans and is often misdiagnosed as Plasmodium malariae due to morphological similarities. The development of an inexpensive, serological detection method utilizing antibodies specific to P. knowlesi would be a valuable tool for diagnosis. However, the identification of specific antigens for these parasites remains a major challenge for generating such assays. In this study, surface protein containing an altered thrombospondin repeat domain (SPATR) was selected as a potentially specific antigen from P. knowlesi. Its multistage expression by sporozoites, asexual erythrocytic forms and gametocytes, along with its possible role in liver cell invasion, suggests that SPATR could be used as a biomarker for diagnosis of P. knowlesi.
    Matched MeSH terms: Immunoblotting/methods