Displaying all 5 publications

Abstract:
Sort:
  1. Rohana J, Khairina W, Boo NY, Shareena I
    Pediatr Int, 2011 Aug;53(4):468-74.
    PMID: 21105964 DOI: 10.1111/j.1442-200X.2010.03295.x
    Occlusive plastic applied immediately after birth to reduce evaporative heat loss has been proven effective in preterm infants <28 weeks' gestation. However its effectiveness on preterm infants >28 weeks' gestation has not been shown. This study aimed to determine the effect of occlusive wrap at birth on the temperature at neonatal intensive care unit (NICU) admission among infants of greater than or equal to 24 weeks' and less than 34 weeks' gestation.
    Matched MeSH terms: Hypothermia/prevention & control*
  2. Shafie H, Syed Zakaria SZ, Adli A, Shareena I, Rohana J
    Pediatr Int, 2017 Jul;59(7):776-780.
    PMID: 28370991 DOI: 10.1111/ped.13285
    BACKGROUND: Occlusive body wrap using polyethylene plastic applied immediately after birth had been shown to reduce hypothermia among preterm infants. Various adjunct methods have been studied in an attempt to further reduce the incidence of hypothermia. This study was conducted to determine whether polyethylene cap is more effective than cotton cap as an adjunct to polyethylene occlusive body wrap in reducing hypothermia in preterm infants.

    METHODS: The subjects consisted of preterm infants 24-34 weeks' gestation born at Universiti Kebangsaan Malaysia Medical Centre. Infants were randomly assigned to NeoCap or control groups. Infants in both groups were wrapped in polyethylene sheets from the neck downwards immediately after birth without prior drying. Infants in the control group had their heads dried and subsequently covered with cotton caps while infants in the NeoCap group had polyethylene caps put on without drying. Axillary temperature was measured on admission to the neonatal intensive care unit (NICU), and after having been stabilized in the incubator.

    RESULTS: Among the 80 infants recruited, admission hypothermia (axillary temperature <36.5°C) was present in 37 (92.5%) and in 40 (100%) in the NeoCap and control groups, respectively. There was no significant difference in mean temperature on NICU admission between the two groups (35.3 vs 35.1°C, P = 0.36). Mean post-stabilization temperature, however, was significantly higher in the NeoCap group (36.0 vs 35.5°C, P = 0.01).

    CONCLUSION: Combined use of polyethylene body wrap and polyethylene cap was associated with a significantly higher mean post-stabilization temperature compared with polyethylene body wrap and cotton cap.

    Matched MeSH terms: Hypothermia/prevention & control*
  3. Koh W, Chakravarthy M, Simon E, Rasiah R, Charuluxananan S, Kim TY, et al.
    BMC Anesthesiol, 2021 08 16;21(1):205.
    PMID: 34399681 DOI: 10.1186/s12871-021-01414-6
    BACKGROUND: Anesthesia leads to impairments in central and peripheral thermoregulatory responses. Inadvertent perioperative hypothermia is hence a common perioperative complication, and is associated with coagulopathy, increased surgical site infection, delayed drug metabolism, prolonged recovery, and shivering. However, surveys across the world have shown poor compliance to perioperative temperature management guidelines. Therefore, we evaluated the prevalent practices and attitudes to perioperative temperature management in the Asia-Pacific region, and determined the individual and institutional factors that lead to noncompliance.

    METHODS: A 40-question anonymous online questionnaire was distributed to anesthesiologists and anesthesia trainees in six countries in the Asia-Pacific (Singapore, Malaysia, Philippines, Thailand, India and South Korea). Participants were polled about their current practices in patient warming and temperature measurement across the preoperative, intraoperative and postoperative periods. Questions were also asked regarding various individual and environmental barriers to compliance.

    RESULTS: In total, 1154 valid survey responses were obtained and analyzed. 279 (24.2%) of respondents prewarm, 508 (44.0%) perform intraoperative active warming, and 486 (42.1%) perform postoperative active warming in the majority of patients. Additionally, 531 (46.0%) measure temperature preoperatively, 767 (67.5%) measure temperature intraoperatively during general anesthesia, and 953 (82.6%) measure temperature postoperatively in the majority of patients. The availability of active warming devices in the operating room (p 

    Matched MeSH terms: Hypothermia/prevention & control*
  4. Boo NY, Selvarani S
    Singapore Med J, 2005 Aug;46(8):387-91.
    PMID: 16049607
    This study aimed to determine the proportions of normothermic infants who remained normothermic, and hypothermic infants who became normothermic following the use of a heated water-filled mattress (HWM) in the labour room.
    Matched MeSH terms: Hypothermia/prevention & control*
  5. Boo NY, Chew EL
    Singapore Med J, 2006 Sep;47(9):757-62.
    PMID: 16924356
    This study aimed to compare the core, abdominal wall, and plantar temperatures of well jaundiced term infants undergoing phototherapy with or without clingfilm covering the lower two-thirds of the upper end of their bassinets.
    Matched MeSH terms: Hypothermia/prevention & control*