Displaying all 15 publications

Abstract:
Sort:
  1. Lukman MR, Sangar P, Sukumar N
    Med J Malaysia, 2007 Mar;62(1):83-4.
    PMID: 17682583
    Paraesophageal hernias have been historically associated with risk of substantial morbidity and mortality. We report a case of a 92 year old lady with acute gastric outlet obstruction due to a chronic paraesophageal hernia that was successfully treated by minimal invasive surgery. Anterior gastropexy was performed after the stomach was reduced. The hiatal opening was enlarged to reduce the risk of obstruction in the future. She was discharged well on the third day.
    Matched MeSH terms: Herniorrhaphy*
  2. Memon MA, Memon B, Yunus RM, Khan S
    Ann Surg, 2016 Feb;263(2):258-66.
    PMID: 26445468 DOI: 10.1097/SLA.0000000000001267
    The aim was to conduct a meta-analysis of randomized controlled trials (RCTs) comparing 2 methods of hiatal closure for large hiatal hernia and to evaluate their strengths and flaws.
    Matched MeSH terms: Herniorrhaphy/methods*
  3. Chai FY
    World J Surg, 2020 10;44(10):3322-3323.
    PMID: 32524160 DOI: 10.1007/s00268-020-05636-6
    Matched MeSH terms: Herniorrhaphy
  4. Lai JH, Loo GH, Shuhaili MAB, Ritza Kosai N
    Int J Surg Case Rep, 2019;60:276-280.
    PMID: 31261047 DOI: 10.1016/j.ijscr.2019.06.045
    INTRODUCTION: Primary fascial closure can be a challenging step during a laparoscopic intraperitoneal onlay mesh (IPOM) repair for a ventral hernia.

    CASE PRESENTATION: We present here a novel technique of using intravenous (IV) cannula as an alternative to suture passer for fascial closure during laparoscopic IPOM repair for a 59-year-old patient with an incisional ventral hernia. The placement of non-absorbable sutures for fascial closure was done with the help of a 14 gauge IV cannula instead of a transfascial suture passer. The rest of the procedural steps were the same as a standard laparoscopic IPOM repair. The patient's post-operative recovery was uneventful.

    DISCUSSION: Primary fascial closure during a laparoscopic IPOM hernia repair can be done either by intracorporeal or extracorporeal techniques, using interrupted or continuous sutures. We propose a novel alternative to suture passer in primary fascial closure. IV cannulas are widely available in hospital settings. The advantage of using an IV cannula instead of a suture passer is that they are widely available. Its single-use also eliminates the risk of transmissible diseases, and as it has a smaller diameter than suture passer, it requires a lower insertion force for successful placement.

    CONCLUSION: An IV cannula may be used as a more economical alternative to a transfascial suture passer. This technique is easily reproducible and does not violate the principles of primary fascial defect closure in laparoscopic ventral hernia repair.

    Matched MeSH terms: Herniorrhaphy
  5. Kong CY, Lai LL, Khoo AYY, Rahman NA, Chin KF
    BMC Surg, 2016 Feb 11;16:8.
    PMID: 26864939 DOI: 10.1186/s12893-016-0123-8
    BACKGROUND: Polypropylene meshes are widely used in hernia repairs. Hernia meshes have been developed incorporating coatings of active agents. One commercially available mesh has a fish oil coating which is promoted as having anti-inflammatory properties. We report a case, a symptomatic foreign body granuloma reaction associated with a fish oil coated polypropylene mesh, which required eventual mesh explantation.

    CASE PRESENTATION: A 61-year old lady with previous peptic ulcer disease underwent a laparoscopic intraperitoneal placement of mesh for incisional hernia utilising a fish oil coated polypropylene mesh. The patient presented 3 months after the procedure complaining of dyspepsia and pain at the operative site. There was no discharge. The patient was managed conservatively. She presented 10 months post-operatively with progressively worsening symptoms and a hard palpable mass in the epigastrium. Abdominal laparoscopy revealed dense adhesive disease around the mesh with exudates. Adhesiolysis, mesh explantation and a partial gastrectomy was performed. Histopathological examination revealed a foreign body granuloma formation to the mesh.

    CONCLUSION: In-vivo studies looking at intraperitoneal mesh placement with fish oil coatings including data on surgical outcomes such as fistula and adhesive characteristics are scarce in the literature. Further monitoring and studies are required to investigate the safety and efficacy profile of this mesh type in in-vivo models.

    Matched MeSH terms: Herniorrhaphy/adverse effects; Herniorrhaphy/instrumentation*
  6. Yussra Y, Sutton PA, Kosai NR, Razman J, Mishra RK, Harunarashid H, et al.
    Clin Ter, 2013;164(5):425-8.
    PMID: 24217830 DOI: 10.7417/CT.2013.1608
    Inguinal hernia remains the most commonly encountered surgical problem. Various methods of repair have been described, and the most suitable one debated. Single port access (SPA) surgery is a rapidly evolving field, and has the advantage of affording 'scarless' surgery. Single incision laparoscopic surgery (SILS) for inguinal hernia repair is seen to be feasible in both total extraperitoneal (TEP) and transabdominal pre-peritoneal (TAPP) approaches. Data and peri-operative information on both of these however are limited. We aimed to review the clinical experience, feasibility and short term complications related to laparoscopic inguinal hernia repair via single port access. A literature search was performed using Google Scholar, Springerlink Library, Highwire Press, Surgical Endoscopy Journal, World Journal of Surgery and Medscape. The following search terms were used: laparoscopic hernia repair, TAPP, TEP, single incision laparoscopic surgery (SILS). Fourteen articles in English language related to SILS inguinal hernia repair were identified. Nine articles were related to TEP repair and the remaining 5 to TAPP. A total of 340 patients were reported within these studies: 294 patients having a TEP repair and 46 a TAPP. Only two cases of recurrence were reported. Various ports have been utilized, including the SILS port, Tri-Port and a custom- made port using conventional laparoscopic instruments. The duration of surgery was 40-100 minutes and the average length of hospital stay was one day. Early outcomes of this novel technique show it to be feasible, safe and with potentially better cosmetic outcome.
    Matched MeSH terms: Herniorrhaphy/methods*
  7. Siow SL, Mahendran HA, Hardin M, Chea CH, Nik Azim NA
    Asian J Surg, 2013 Apr;36(2):64-8.
    PMID: 23522757 DOI: 10.1016/j.asjsur.2012.11.004
    Using laparoscopic methods for incarcerated scrotal hernias is controversial because of the perceived technical difficulties in treating such hernias. Herein, we present our experience with laparoscopic repair of such hernias.
    Matched MeSH terms: Herniorrhaphy/methods*
  8. Christodoulidou, M., Kosai, N.R., Rajan, R., Hassan, S., Dac, S., Sutton, P.A., et al.
    MyJurnal
    Introduction: Laparoscopic fundoplication is performed for the management of symptomatic hiatus hernias and gastro-oesophageal reflux disease (GORD) refractory to medical therapy. We adopted the use of Gore Bio-A® for selected laparoscopic hiatus hernia repairs in 2011 and with this case series aimed to establish whether mesh augmentation affects symptomatic outcomes. Methods: A retrospective review of prospectively collected data from all laparoscopic fundoplications performed by a single surgeon between October 2011 and January 2013 was performed. Patient specific data were entered into a proforma and analysed using Microsoft ExcelTM. Patient reported outcomes were assessed with a system specific quality of life questionnaire (GORD-HRQL) both pre and post-operatively. Results: Twenty-three patients underwent laparoscopic fundoplication during the study period. Gore Bio-A® re-enforcement of the hiatal repair was used in 14 patients and was the preferred option for those with pre-operative evidence of a large hiatus hernia. Whilst overall there was a statistically significant difference between pre and post-operative scores (21 vs 0, p=
    Matched MeSH terms: Herniorrhaphy
  9. Liew W, Wai YY, Kosai NR, Gendeh HS
    Hernia, 2017 08;21(4):549-554.
    PMID: 28417279 DOI: 10.1007/s10029-017-1611-1
    PURPOSE: Laparoscopic hernioplasty has become a popular choice for inguinal hernia repair since its advent in 1990s. Postoperative pain is an undesirable clinical outcome impairing daily activity of 22.5% of patients. The aim of this study is to evaluate postoperative acute and chronic pain via inflammatory markers as an objective assessment following tacks or glue mesh fixation in TEP repair.

    METHODS: Sixty-six (66) patients with unilateral uncomplicated inguinal hernia were randomized into 34 patients in the tacker and 32 patients in cyanoacrylate glue mesh fixation in TEP repair. The extent of surgical trauma was evaluated by measuring inflammatory markers of C-reactive protein, white blood cell count at 48 h, and ESR at 3 months postoperatively. Postoperative acute and chronic pain was assessed by recording the visual analogue scale scores and surgical complications were recorded over 3 months of the study period.

    RESULTS: The median CRP and WBC levels at postoperative 48 h in both groups raised significantly from the baseline values (p  0.05). The median ESR level increased significantly at 3 months postoperatively from baseline in the glue mesh fixation group only (p  0.05). There was no significant difference for VAS scores at all timelines between the tacker and glue mesh fixation group (p > 0.05).

    CONCLUSION: Cyanoacrylate glue mesh fixation technique as an alternative method to mechanical fixation in TEP repair is comparable to tacker and can be considered to be safe and feasible.

    Matched MeSH terms: Herniorrhaphy/methods*
  10. Tan GH, Harunarashid H, Das S, Goh YH, Ramzisham AR
    Clin Ter, 2010;161(6):533-4.
    PMID: 21181082
    An internal hernia through the mesosalpinx is a rare condition which is often overlooked. We report the case of a 65-year-old lady who presented with features of small bowel obstruction. At laparotomy, a gangrenous ileum was found to have herniated through a defect in the right mesosalpinx. We discuss this rare cause of a small bowel obstruction and its diagnostic dilemma.
    Matched MeSH terms: Herniorrhaphy
  11. Kihne M, Ramanujam TM, Sithasanan N
    Med J Malaysia, 2006 Jun;61(2):251-3.
    PMID: 16898325 MyJurnal
    Mesocolic hernia is a rare cause of intestinal obstruction in children. The diagnosis involves a high index of suspicion and prompt intervention to prevent strangulation and a high morbidity. The embryological basis of the condition is of paramount importance to assist the eventual surgical correction.
    Matched MeSH terms: Herniorrhaphy
  12. Wong PS
    Med J Malaysia, 1999 Dec;54(4):523-5.
    PMID: 11072475
    Pericardial rupture after blunt chest trauma is described in the literature. This case report summarises our experience with a 22-year old male patient who suffered blunt chest trauma during a motor vehicle accident. On admission no serious injuries could be detected, but 3 hours later, displacement of the heart to the right hemithorax combined with sudden cardiac failure appeared. Emergency thoracotomy revealed a right-sided rupture of the pericardium with complete herniation of the heart into the right pleural cavity and consequent strangulation by the margins of the pericardial defect.
    Matched MeSH terms: Herniorrhaphy
  13. Tham LY, Beh ZY, Shariffuddin II, Wang CY
    Korean J Anesthesiol, 2019 12;72(6):606-609.
    PMID: 31304693 DOI: 10.4097/kja.d.18.00354
    BACKGROUND: The laryngeal mask airway (LMAⓇ) ProtectorTM (Teleflex Medical Co., Ireland) is the latest innovation in the second generation of LMA devices. One distinguishing feature of this device is its integrated, color-coded cuff pressure indicator (Cuff PilotTM technology) which enables continuous cuff pressure monitoring and allows adjustments when necessary; this ensures patient safety due to better monitoring.

    CASE: We report a case of postoperative unilateral hypoglossal nerve palsy after uncomplicated use of the LMA Protector. To the best of our knowledge, this could be the second reported case.

    CONCLUSIONS: This case demonstrates that anesthetists need to routinely measure cuff pressure and that the Cuff PilotTM technology is not a panacea for potential cranial nerve injury after airway manipulation.

    Matched MeSH terms: Herniorrhaphy
  14. Pue LB, Lo TS, Wu PY, Tan YL
    J Obstet Gynaecol Res, 2014 Feb;40(2):611-3.
    PMID: 24245849 DOI: 10.1111/jog.12174
    Abdominal sacrocolpopexy is a well-established procedure for the reconstruction of apical support in pelvic organ prolapse. Its long-term efficacy is well known; however, it is also associated with higher perioperative morbidity when compared with the less invasive transvaginal approach. Long-term risk of bowel-related complication from abdominal sacrocolpopexy is rare, but can be significant as it is often serious and requires major surgical intervention. Here we highlight an unusual case of strangulated small bowel (in this instance complicated with sepsis secondary to peritonitis), 14 years after an abdominal sacrocolpopexy procedure. This example amplifies the need for proper preoperative counseling; also, life-long follow-up is necessary for patients undergoing this procedure.
    Matched MeSH terms: Herniorrhaphy
  15. Quah BS, Malik AS, Simpson H
    Malays J Med Sci, 2000 Jan;7(1):27-32.
    PMID: 22844212 MyJurnal
    Experience of acute medical, surgical conditions, and clinical procedures of undergraduate students were assessed via a questionnaire survey during the final week of the 1993/1998 programme at the School of Medical Sciences, Univestiti Sains Malaysia. Individual performances were assessed by a scoring system. One hundred and twenty four students responded, (response rate 97%). More than 90% had seen myocardial infarction, cerebrovascular accident, pneumonia, respiratory distress, gastroenteritis, coma, and snake bite. Less than 33% had witnessed acute psychosis, diabetic ketoacidosis, acute hepatic failure, status epilepticus, near drowning, hypertensive encephalopathy, acute haemolysis or child abuse.Acute surgical/obstetrics cases, seen by >90% students, included fracture of long bones, head injury, acute abdominal pain, malpresentation and foetal distress. Less than 33% had observed epistaxis, sudden loss of vision, peritonitis or burns. Among operations only herniorrhaphy, Caesarian section, internal fixation of fracture and cataract extraction were seen by >80% students. The main deficits in clinical procedures are in rectal and vaginal examinations, urine collection and microscopic examinations. The performance of individual students, assessed by a scoring system, showed 15 students had unacceptably low scores (<149/230, 50%), 37 had good scores (>181.4/230, 70%) and 5 had superior scores (197.6/230, 80%).
    Matched MeSH terms: Herniorrhaphy