Displaying all 11 publications

Abstract:
Sort:
  1. Khairul Nizam Siron, Lim, Chia Hua
    MyJurnal
    Neer first popularised the use of primary hemiarthroplasty to treat complex proximal
    humerus fractures, especially when the humeral head is nonviable or not
    reconstructable with internal fixations, and with younger patients. (Copied from article).
    Matched MeSH terms: Hemiarthroplasty
  2. Kunnasegaran R, Chan YH
    Malays Orthop J, 2017 Mar;11(1):64-67.
    PMID: 28435578 DOI: 10.5704/MOJ.1703.007
    The treatment of fractures in osteopetrosis can be complicated and difficult. We describe the use of an industrial grade tungsten carbide drill bit in the treatment of one of these complex fractures. An industrial grade tungsten carbide drill bit was used to fashion a medullary canal in the surgical treatment of a left peri-implant fracture of the neck of femur in a patient with osteopetrosis. The patient was successfully treated with a hemiarthroplasty with good functional outcomes. A tungsten carbide drill bit serves as an effective and safe option in the treatment of osteopetrotic femoral neck fractures.
    Matched MeSH terms: Hemiarthroplasty
  3. Lee, K.H., Ng, A.B.Y., Tan, T.B., Mossinac, K., To, B.C. Se
    Malays Orthop J, 2008;2(2):11-15.
    MyJurnal
    Gentamicin, whether administered either intravenously, incorporated into bone cement or for local intra-operative irrigation, is a commonly used antibiotic in orthopaedic practice. The former two have been well studied, however the literature on the therapeutic efficacy and safety of gentamicin irrigation is sparse. The objective of this study was to assess systemic absorption of gentamicin irrigation in joint replacement surgery. This was a non-randomised, prospective study. Ninety-eight patients (group A) who underwent total joint replacement and 40 patients (group B) who underwent hemi-arthroplasty were treated traoperatively with gentamicin irrigation. Serum gentamicin levels were assayed at 4 hours and 24 hours post-surgery. Sixteen of 98 patients in group A (16%) and 12 out of 40 patients in group B (30%) were found to have serum gentamicin level above 2mcg/ml at 4 hours post-surgery. We conclude that intra-articular gentamicin irrigation is systemically absorbed at substantial levels.
    Matched MeSH terms: Hemiarthroplasty
  4. Krishnan, H., Yoon, T.R., Park, K.S.
    Malays Orthop J, 2010;4(1):26-31.
    MyJurnal
    This retrospective study was undertaken to analyze perioperative parameters, functional outcomes and complications of cemented versus uncemented bipolar hemiarthroplasty in elderly patients presenting with displaced intracapsular femoral neck fracture. The authors reviewed 17 patients that underwent cemented bipolar hemiarthroplasty and 21 patients that underwent uncemented bipolar hemiarthroplasty. The mean follow-up duration in the cemented and uncemented group was 29.9 and 30.5 months respectively. Intraoperative and postoperative blood loss was higher in the cemented group. On the last follow-up the mean HHS was 74.7 in the cemented group and 84.2 in the uncemented group. No statistically significant difference was evident in the pain score. In summary, bipolar hemiarthroplasty was found to be a good option for displaced intracapsular femoral neck fractures, and overall outcome was marginally better in the uncemented group in terms of postoperative of blood loss and functional outcome at last follow up.
    Matched MeSH terms: Hemiarthroplasty
  5. William C, Simmrat S, Suhaeb AM
    Malays Orthop J, 2017 Jul;11(2):78-81.
    PMID: 29021886 MyJurnal DOI: 10.5704/MOJ.1707.015
    Infection of the hip after implant fixation is an uncommon yet devastating complication that results in poor long-term outcome. The gold standard treatment for chronic infection after hip arthroplasty is a two-stage protocol: eradication of infection, follow by re-implantation arthroplasty. The use of interim antibiotic-laden cement spacer has become a popular procedure to maintain hip joint function and provide antibiotic elution simultaneously before re-implantation. However, antibiotic cement spacer is mechanically weak and breaks if overloaded. Therefore, we designed a cement mould with metallic endoskeleton with the aim of creating a stronger, inexpensive, antibiotic-impregnated spacer resembling a unipolar arthroplasty. We report two cases of severe hip joint infection after implant fixation (bipolar hemiarthroplasty, screw fixation neck of femur). Both patients had undergone first stage surgery of debridement and articulating antibiotic cement insertion using our design. Although the second stage surgery was planned for these patients, both patients delayed the operation in view of good functional status after a year walking with the antibiotic cement spacer. These cases showed that the mechanical property of the new antibiotic cement spacer was promising but further mechanical studies upon this new endoskeleton design are required.
    Matched MeSH terms: Hemiarthroplasty
  6. Park KS, Chan CK, Lee DH, Yoon TR
    Indian J Orthop, 2018 8 7;52(4):369-373.
    PMID: 30078894 DOI: 10.4103/ortho.IJOrtho_494_16
    Background: Conversion from failed bipolar hemiarthroplasty (HA) to total hip arthroplasty (THA) presents a great challenge to orthopedic surgeons for bipolar head removal and cup placement with or without change of femoral stem. Conversion THA after failed bipolar arthroplasty is known to offer both symptomatic and functional improvement. This study evaluates the midterm functional outcome and complications, especially dislocation associated with femoral head diameter, after conversion THA.

    Materials and Methods: Forty eight hips with the conversion of bipolar HA to THA were followed up for an average 6.2 years (range 2.0-11.5 years). Twenty one hips had conversion surgery to THA using metal-on-metal articulation (28 or 32 mm head). Nine hips used ceramic-on-ceramic (28-40 mm) and eighteen hips used large head metal-on-metal bearing (>40 mm). Outcome was evaluated using Harris Hip Score (HHS) and Western Ontario McMaster Universities Osteoarthritis Index (WOMAC) score. The radiographs were analyzed for evidence of osteolysis and/or loosening. The complications were evaluated, especially dislocation with different femoral head diameter.

    Results: Average HHS significantly improved from 42 preoperatively to 86 postoperatively and the average WOMAC score also significantly improved from 47 to 22 postoperatively. Radiological evaluation showed all the femoral components were stable. There was one acetabular component loosening, which required revision 9 years after conversion to THA. One dislocation and one recurrent dislocation were recorded in isolated acetabular revision hip; whereas one dislocation, one recurrent dislocation, and one trochanteric nonunion occurred in the hips with revision of both components. All dislocations occurred in hips with a femoral head size of 28 mm (P = 0.052). The cup and femoral head interval length was the most significant factor contributing to dislocation (P = 0.013).

    Conclusions: Conversion THA after failed bipolar HA offers a reliable pain relief and functional improvement. To prevent dislocation, it is highly recommended to use a larger diameter femoral head, especially where the cup size is big.

    Matched MeSH terms: Hemiarthroplasty
  7. Balaji G, Sriharsha Y, Sharma D
    Malays Orthop J, 2019 Jul;13(2):49-51.
    PMID: 31467653 DOI: 10.5704/MOJ.1907.010
    A 58-year old female patient presented to us with a three months' old fracture of the neck of femur. She underwent bipolar hemiarthroplasty. In the immediate postoperative period, she developed deep vein thrombosis for which she was started on anticoagulant therapy. Patient had persistent discharge from the wound since then and underwent regular dressings. On the eighth post-op day, she developed sciatic nerve palsy secondary to wound haematoma. The haematoma was decompressed immediately and she had a dramatic improvement in pain but her neurological deficit persisted. The wound healed completely without any complications. At three months follow up, she had recovered completely with grade 5/5 power in ankle and foot and full sensory recovery in the sciatic nerve distribution. She was ambulating comfortably with a walker. At final follow up around 20 months post-operation, she was pain-free and walking without any support. The wound had healed completely.
    Matched MeSH terms: Hemiarthroplasty
  8. Wam, B.L., Chee, E.K., Ewe, T.W.
    Malays Orthop J, 2010;4(3):11-15.
    MyJurnal
    The PROSTALAC (PROSThesis Antibiotic Loaded Acrylic Cement) functional spacer is made with antibiotic-loaded acrylic cement. We use it as an interim spacer in two-stage exchange arthroplasty in cases of infected total knee or total hip replacement. PROSTALAC allows continuous rehabilitation between stages as it maintains good alignment and stability of the joint with a reasonable range of movement. It also helps to maintain the soft-tissue planes, thereby facilitating the second-stage procedure. We report here early outcomes of the use of PROSTALAC in 5 patients - 3 in total knee replacements, 1 in a total hip replacement and 1 in a bipolar hemiarthroplasty.
    Matched MeSH terms: Hemiarthroplasty
  9. Harjeet, S., Suhail, A., Shahril, Y., Masbah, O., Subanesh, S.
    Malays Orthop J, 2009;3(1):24-27.
    MyJurnal
    Fracture of the femoral neck is one of the most common types of osteoporotic fractures. Hemiarthroplasty continues to be a good option despite current calls for total hip arthroplasty in this subset of patients. The hemiarthroplasty is less expensive and easier to perform, and can be adequately carried out in smaller hospitals with basic orthopaedic facilities staffed by general orthopaedists. Functional demands of the elderly among Asians are often less compared to similar subsets of Western population on which most comparative hip studies are based. This study was undertaken to investigate the outcome for femoral neck fractures treated with conventional hemiarthroplasty. The authors hope to provide information based on local data as a reference for our doctors and patients.
    Matched MeSH terms: Hemiarthroplasty
  10. Gema A, Irianto KA, Setiawati R
    Malays Orthop J, 2021 Mar;15(1):63-71.
    PMID: 33880150 DOI: 10.5704/MOJ.2103.010
    Introduction: Early femoral stem subsidence has been a concern as a predictor of the beginning of implant loosening, especially on cementless hip arthroplasty implants. This study aimed to determine the factors that affect femoral stem subsidence and outcome following hemiarthroplasty in the geriatric population.

    Materials and Methods: This is a retrospective study of 179 patients who underwent cementless bipolar hemiarthroplasty during the 2011-2019 period at an orthopaedic and traumatology hospital. Data on the patient's demography, pre-operative American Society Anaesthesiologist (ASA) score, body mass index (BMI), canal flare index (CFI), Dorr classification, and stem alignment were obtained. The primary outcomes were post-operative femoral stem subsidence, post-operative pain, and functional outcome using Harris Hip Score (HHS). Statistical analysis was conducted to identify risk factors associated with the primary outcome.

    Results: The mean femoral stem subsidence was 2.16 ±3.4 mm. The mean post-operative Visual Analog Score (VAS) on follow-up was 1.38 ± 1. Mean HHS on follow-up was 85.28±10.3. American Society Anaesthesiologist score 3 (p = 0.011, OR = 2.77) and varus alignment (p=0.039, OR = 6.963) were related to worse stem subsidence. Otherwise, neutral alignment (p = 0.045 and OR = 0.405) gave protection against femoral stem subsidence. The female gender (p = 0.014, OR 2.53) was associated with postoperative pain onset. Neutral alignment had significant relationship with functional outcomes (p = 0.01; OR 0.33).

    Conclusion: A higher ASA score and varus stem alignment were related to a higher risk of femoral stem subsidence. Meanwhile, neutral stem alignment had a protective effect on the femoral stem subsidence and outcome.

    Matched MeSH terms: Hemiarthroplasty
  11. Lim CY, Mat-Hassan S, Awang M, Md-Ariff MF, Hau-Abdullah MA
    Malays Orthop J, 2019 Nov;13(3):21-27.
    PMID: 31890106 DOI: 10.5704/MOJ.1911.004
    Introduction: Proximal femur resection and endoprosthetic reconstruction is the preferred treatment for extensive bony destruction and pathological fractures. Due to the relatively high cost of endoprosthesis, we adopted the modified unipolar hemiarthroplasty (MUH) for reconstruction when the mode of treatment was for palliation. Materials and Methods: This is a retrospective case study of six patients, who had bone and multi-organs metastases with extensive proximal femur involvement with pathologic fractures who underwent resection and MUH reconstruction during the period 2013 to 2017. All patients were classified as Group B / C based on Scandinavian Sarcoma Group survival scoring, with estimated survival of maximum six months. The basic MUH construct consisted of Austin-Moore prosthesis which was secured to a Küntscher nail using cerclage wire and cemented into the femoral canal. Subsequently, the whole length of the prosthesis which remained outside the canal was coated with cement. Results: The mean age was 61.8 years. The mean survival was 3.9 months, post-operation. There was no implant failure during patients' life span; however, a third of the patients developed infection. Wheel chair ambulation was started immediately post-operation for all patients, and two patients progressed to walking frame ambulation. The total cost of each construct was below US$490 in comparison to long-stem hemiarthroplasty (roughly US$ 1700). Conclusion: Our aim was to alleviate pain, facilitate rehabilitation, ease nursing care and improve quality of life for metastatic bone disease patients until end of life. MUH for the treatment of pathological fracture in proximal femoral metastases is a feasible palliative surgical modality in resource-limited settings.
    Matched MeSH terms: Hemiarthroplasty
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links