Displaying all 3 publications

Abstract:
Sort:
  1. Tan MC, Ng OC, Yap RYP, Pan Y, Chieng JY
    Fecal occult blood test (FOBT) screening has been shown to decrease the incidence and mortality of colorectal cancer (CRC). The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the immunochemical fecal occult blood test (i-FOBT) in diagnosing CRC were assessed among the patients in a tertiary referral hospital in Malaysia. A total sample of 814 patients aged 16 to 85 years old who performed i-FOBT and endoscopic screenings was obtained. The patients were recruited for a retrospective investigation. Sensitivity, specificity, PPV, and NPV were derived for the CRC screenees. Out of the 814 patients screened using i-FOBT, half of them were above 59 years old (49.6%), and 36% had positive i-FOBT. Gender distribution was almost equal, where 53.4% of the patients were female, and 46.6% were male. Majority of the patients were Malays (56.6%), followed by Chinese (24.0%), Indians (16.5%), and others (2.9%). Among the 71 patients referred for colonoscopy, 57.7% and 42.3% corresponded to positive and negative i-FOBT cases, respectively. Polyps were found to be most common among the patients (25.6%), 7.0% were found positive for invasive CRC, and 35.2% had normal colonoscopic findings. There was a significant association between colonoscopic finding and positive i-FOBT (p=0.001). The sensitivity, specificity, PPV, and NPV for CRC detection were 66.7%, 43.0%, 9.8%, and 93.3%, respectively. The results indicate that i-FOBT is a useful tool in the detection of abnormalities in the lower gastrointestinal tract and therefore serves as a cornerstone for potential large-scale screening programmes.
    Matched MeSH terms: Guaiac
  2. Che Alhadi S, Wan Zain WZ, Zahari Z, Md Hashim MN, Syed Abd Aziz SH, Zakaria Z, et al.
    Ann Coloproctol, 2020 Dec;36(6):409-414.
    PMID: 32972105 DOI: 10.3393/ac.2020.08.27
    PURPOSE: Guaiac fecal occult blood test (gFOBT) has been the standard for colorectal screening but it has low sensitivity and specificity. This study evaluated the use of fecal tumor M2-pyruvate kinase (M2-PK) for detection of colorectal cancer and to compare with the current surveillance tool; gFOBT in symptomatic adult subjects underwent colonoscopy.

    METHODS: Stool samples were collected prospectively from symptomatic adults who had elective colonoscopy from September 2014 to January 2016 and were analyzed with the ScheBo M2-PK Quick test and laboratory detection of fecal hemoglobin.

    RESULTS: The results were correlated to the colonoscopy findings and/or histopathology report. Eighty-five subjects (age of 56.8 ± 15.3 years [mean ± standard deviation]) were recruited with a total of 17 colorectal cancer (20.0%) and 10 colorectal adenoma patients (11.8%). The sensitivity of M2-PK test in colorectal cancer detection was higher than gFOBT (100% vs. 64.7%). M2-PK test had a lower specificity when compared to gFOBT (72.5% vs. 88.2%) in colorectal cancer detection. The positive and negative predictive values were 47.2% and 100% for M2-PK test and 57.9% and 90.9% for gFOBT.

    CONCLUSION: Fecal M2-PK Quick test has a high sensitivity for detection of colorectal cancer when compared to gFOBT, making it the potential choice for colorectal tumor screening biomarker in the future.

    Matched MeSH terms: Guaiac
  3. Roslani AC, Abdullah T, Arumugam K
    Asian Pac J Cancer Prev, 2012;13(1):237-41.
    PMID: 22502676
    OBJECTIVE: Screening for colorectal cancer using guaiac-based fecal occult blood tests (gFOBT) is well established in Western populations, but is hampered by poor patient compliance due to the imposed dietary restrictions. Fecal immunochemical tests (FIT) do not require dietary restriction, but are more expensive than gFOBT and therefore restrict its use in developing countries in Asia. However, Asian diets being low in meat content may not require diet restriction for gFOBT to achieve equivalent results. The objective of this study was to evaluate and compare the validity and suitability of gFOBT and FIT or a combination of the two in screening for colorectal neoplasias without prior dietary restriction in an Asian population.

    METHODS: Patients referred to the Endoscopic Unit for colonoscopy were recruited for the study. Stool samples were collected prior to bowel preparation, and tested for occult blood with both gFOBT and FIT. Dietary restriction was not imposed. To assess the validity of either tests or in combination to detect a neoplasm or cancer in the colon, their false positive rates, their sensitivity (true positive rate) and the specificity (true negative rate) were analyzed and compared.

    RESULTS: One hundred and three patients were analysed. The sensitivity for picking up any neoplasia was 53% for FIT, 40% for gFOBT and 23.3% for the combination. The sensitivities for picking up only carcinoma were 77.8% , 66.7% and 55.5%, respectively. The specificity for excluding any neoplasia was 91.7% for FIT, 74% for gFOBT and 94.5% for a combination, whereas for excluding only carcinomas they were 84%, 73.4% and 93.6%. Of the 69 with normal colonoscopic findings, FOBT was positive in 4.3%, 23.2 %and 2.9% for FIT, gFOBT, or combination of tests respectively.

    CONCLUSION: FIT is the recommended method if we are to dispense with dietary restriction in our patients because of its relatively low-false positivity and better sensitivity and specificity rates.