Displaying all 9 publications

Abstract:
Sort:
  1. Roberts AD, Brackley CA
    J Dent, 1996 Sep;24(5):339-43.
    PMID: 8916648
    OBJECTIVES: A survey of general dental practitioners and dental surgery assistants was carried out to ascertain their preferences and opinions on powder-free hydrogel-coated gloves compared with starch-powdered gloves. The aim was to relate the survey findings to laboratory measurements of the frictional characteristics of glove inner surfaces and their water absorptive capability.

    METHODS: The survey was carried out using a questionnaire given to local dental practitioners. Glove friction and water absorption measurements were made using specially designed equipment.

    RESULTS: The survey showed that a selected group of dentist and dental surgery assistants preferred hydrogel-coated gloves, particularly for damp donning, durability and long-term wear comfort. Laboratory measurements showed that the hydrogel coating gave a low friction coefficient against damp skin. The coating was durable, and absorbed water more readily than other treatments.

    CONCLUSION: A survey of dental practitioners and dental surgery assistants and laboratory measurements indicates that hydrogel-coated gloves have superior properties, and are preferred to other non-sterile glove types.

    Matched MeSH terms: Gloves, Surgical*
  2. How SW, Low DYS, Leo BF, Manickam S, Goh BH, Tang SY
    J Hosp Infect, 2023 Jul;137:24-34.
    PMID: 37044283 DOI: 10.1016/j.jhin.2023.03.022
    Following recent viral outbreaks, there has been a significant increase in global demand for gloves. Biomedical research focuses increasingly on antimicrobial gloves to combat microbial transmission and hospital-acquired infections. Most antimicrobial gloves are manufactured using antimicrobial chemicals such as disinfectants, biocides and sanitizers. The design of antimicrobial gloves incorporates advanced technologies, including colloidal particles and nanomaterials, to enhance antimicrobial effectiveness. A category of antimicrobial gloves also explores and integrates natural antimicrobial benefits from animals, plants and micro-organisms. Many types of antimicrobial agents are available; however, it is crucial that the selected agent exhibits a broad spectrum of activity and is not susceptible to promoting resistance. Additionally, future research should focus on the potential effect of antimicrobial gloves on the skin microbiota and irritation during extended wear. Careful integration of the antimicrobial agent is essential to ensure optimal effectiveness without compromising the mechanical properties of the gloves.
    Matched MeSH terms: Gloves, Surgical
  3. Kahar Bador M, Rai V, Yusof MY, Kwong WK, Assadian O
    J Hosp Infect, 2015 Jul;90(3):248-52.
    PMID: 25982193 DOI: 10.1016/j.jhin.2015.03.009
    Inappropriate use of medical gloves may support microbial transmission. New strategies could increase the safety of medical gloves without the risk of patient and surface contamination.
    Matched MeSH terms: Gloves, Surgical/microbiology*; Gloves, Surgical/standards
  4. Razak IA, Latifah RJ, Nasruddin J, Esa R
    Clin Prev Dent, 1991 Jul-Aug;13(4):22-4.
    PMID: 1884572
    A questionnaire was mailed to 1217 dentists whose names appear in the Dentist Register of 1987 in order to assess their awareness and acceptance of hepatitis B vaccine and their pattern of glove usage. Almost all the respondents (99.6%) were aware of the availability of the hepatitis B vaccine yet only 44.8% have received the vaccine. This is in spite of the fact that the majority (61.2%) of the vaccine non-acceptors have no reservations concerning the vaccine. About 71% and 63% of the vaccine-acceptors and non-acceptors respectively believed that the risk of their contracting hepatitis B was high or very high. About 22% of the vaccine non-acceptors never used gloves when treating patients as compared to 9% among vaccine acceptors. Overall, about 78% of the respondents have experienced needleprick injuries in the 3 years preceding the survey.
    Matched MeSH terms: Gloves, Surgical/utilization
  5. Devaraj, V., Zairossani, M.N.
    ASM Science Journal, 2012;6(1):15-21.
    MyJurnal
    Malaysia is the world’s top manufacturer of examination and surgical natural rubber (NR) gloves, exported mainly to the USA and Europe. The glove manufacturing process yields effluent which must be treated to comply with the stringent regulatory requirements imposed by the Malaysian Department of Environment. To make glove manufacturing an eco-friendly process, efforts are geared towards minimizing and utilizing waste or converting it into raw material for making value-added products. Waste generated from the glove industry is mainly rubber sludge which is obtained from the chemical flocculation stage of the effluent treatment process and consists of mainly rubber, remnants of compounding ingredients and water. R&D work by the Malaysian Rubber Board on waste utilization and resource recovery investigations have revealed many uses for this sludge. This paper briefly outlines only one of the many options available, which is the conversion of the sludge into sludge derived fuel (SDF). Preliminary study has identified three formulations of SDF with calorific values (CV) exceeding 16 000 kJ/kg, matching a good grade coal. This was considered as promising results which warrant explorative work for further increasing the CV of SDF to turn it into a viable fuel substitute in the latex products manufacturing industry and subsequently apply for a Clean Development Mechanism status to generate income.
    Matched MeSH terms: Gloves, Surgical
  6. Chan KY, Singh VA, Oun BH, To BH
    Med J Malaysia, 2006 Dec;61 Suppl B:3-7.
    PMID: 17605178
    Glove perforation during surgery has always been a matter of concern as it increases the infection rate and the risk of transmission of blood borne diseases. To determine the common causes, the site and the awareness of glove perforations in orthopaedic surgery, a prospective study was conducted to assess the rate of glove perforation during 130 consecutive orthopaedic operations. All gloves worn by the surgical team were assessed after the surgery using the water-loading test. A total of 1452 gloves were tested, and the rate of perforation was 3.58%. Most of these perforations (61.5%) were unnoticed. The main surgeons had the most perforations (76.9%), followed by first assistants (13.5%) and second assistants (9.6%). Most perforations occurred at the non-dominant hand. The commonest site of perforation was the index finger followed by the thumb. Shearing force with instruments accounted for 45% of the noticed perforations. Majority of these occurred during nailing procedures (33%) and internal fixation without the use of wires (19%). Our rate of glove perforation is similar to other series. Most of them went unnoticed and were mainly due to shearing injuries rather than perforation by sharps. Therefore, there is an increased risk of contamination and break in asepsis during surgery.
    Matched MeSH terms: Gloves, Surgical*
  7. Leitgeb J, Schuster R, Yee BN, Chee PF, Harnoss JC, Starzengruber P, et al.
    BMC Surg, 2015 Jul 04;15:81.
    PMID: 26141495 DOI: 10.1186/s12893-015-0058-5
    BACKGROUND: A surgical glove will protect surgeons and patients only if the glove's integrity remains intact. However, several studies have demonstrated that undetected micro-perforations of surgical gloves are common. Because of the possibility of surgical glove puncture, an antimicrobial surgical glove was developed. The aim of this laboratory based experimental study was to assess the antibacterial efficacy of the interior chlorhexidine-gluconate (CHG)-coat of an antimicrobial synthetic polyisoprene surgical glove by using a standardized microbiological challenge.

    METHODS: Sixteen healthy adult participants donned one antimicrobial surgical glove and one non-antimicrobial surgical glove randomly allocated to their dominant and non-dominant hand following a crossover design. During a 2-h wear time, participants performed standardized finger and hand movements. Thereafter, the interior surface of excised fingers of the removed gloves was challenged with 8.00 log10 cfu/mL S. aureus (ATCC 6538) or K. pneumoniae (ATCC 4352), respectively. The main outcome measure was the viable mean log10 cfu counts of the two glove groups after 5 min contact with the interior glove's surface.

    RESULTS: When comparing an antimicrobial glove against an untreated reference glove after 2-h simulated use wear-time, a mean reduction factor of 6.24 log10 (S. aureus) and 6.22 log10 (K. pneumoniae) was achieved after 5 min contact.

    CONCLUSION: These results demonstrate that wearing antibacterial gloves on hands does not negatively impact their antibacterial activity after 2-h of wear. This may have a potential benefit for patient safety in case of glove puncture during surgical procedures.

    Matched MeSH terms: Gloves, Surgical/microbiology*
  8. Turjanmaa K, Palosuo T, Alenius H, Leynadier F, Autegarden JE, André C, et al.
    Allergy, 1997 Jan;52(1):41-50.
    PMID: 9062628
    For the diagnosis of IgE-mediated (immediate) hypersensitivity to natural rubber latex (NRL), skin prick testing with extracts of latex gloves has been widely used, but such extracts are difficult to standardize. The present study aimed to produce on an industrial scale an NRL extract from freshly collected NRL and to evaluate, calibrate, and standardize the extract by both in vivo and in vitro testing. The source material, latex of the rubber tree, Hevea brasiliensis (clone RRIM 600), was frozen immediately after collection in Malaysia and shipped in dry ice to Stallergènes SA, France. Protein and allergen profiles were analyzed by sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE), immunoblotting, isoelectric focusing (IEF), crossed immunoelectrophoresis (CIE), and crossed radioimmunoelectrophoresis (CRIE). Allergen quantification was effected by RAST inhibition. The capacity of the preparation to elicit immediate hypersensitivity reactions in vivo was measured by skin prick testing in 46 latex-allergic patients and 76 nonallergic control subjects. SDS-PAGE and immunoblot profiles of the extract and an NRL standard (E8) provided by the US Food and Drug Administration were almost identical, disclosing several distinct IgE-binding proteins with apparent molecular weights of 14, 20, 27, 30, and 45 kDa, conforming to reported molecular weights of several significant NRL allergens. An arbitrary index of reactivity (IR) of 100 was assigned to the extract at 1:200 dilution (w/v), having a protein content of 22 micrograms/ml. Skin prick testing of latex-allergic patients and controls using the extract at 100 IR revealed 93% sensitivity, 100% specificity, 100% negative predictive value, and 96% positive predictive value. In conclusion, a skin prick test reagent for diagnosis of type I NRL allergy was successfully standardized. The reagent was demonstrated to contain most, if not all, of the currently known clinically significant NRL allergens, and it showed high sensitivity and specificity.
    Matched MeSH terms: Gloves, Surgical/adverse effects
  9. Rohna R, Ganesapillai T, Salbiah D, Zaiton I
    Med J Malaysia, 1999 Mar;54(1):128-31.
    PMID: 10972018
    A two years retrospective analysis of patients diagnosed as contact allergic dermatitis with positive patch test attending the Dermatology clinic was performed. Of the 346 patients with a positive patch test, 14% had occupational dermatitis. This condition affected mainly young and inexperienced workers. An inverse relationship was seen between age and prevalence of occupational allergic dermatitis. Allergic hand dermatitis was the commonest presentation in occupational allergic dermatitis. This was followed by dermatitis of the exposed skin (face, neck, hands and forearms). The common sensitising agents identified were rubber chemicals and nickel. The two main groups at risk were factory workers and medical personnel. The common allergens found in factory workers were epoxy resin, pewter, nickel and rubber chemicals. Exposure dermatitis occurred in patients working in the pewter industry. Two thirds of medical personnel with hand dermatitis were allergic to rubber gloves. One year follow up after patch testing showed that 19% of patients still suffered from chronic dermatitis. Dermatitis improved in 34% of patients. Forty-seven percent were cured and stopped attending the clinic after patch testing and adequate counselling.

    Study site: Dermatology Clinic, Hospital Kuala Lumpur
    Matched MeSH terms: Gloves, Surgical
Related Terms
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links