Displaying all 8 publications

Abstract:
Sort:
  1. Bhugaloo A, Abdullah B, Siow Y, Ng Kh
    Biomed Imaging Interv J, 2006 Apr;2(2):e12.
    PMID: 21614224 MyJurnal DOI: 10.2349/biij.2.2.e12
    The primary objective of this study was to evaluate the specificity and sensitivity of diffusion weighted MR imaging (DWI) in the differentiation and characterisation between benign and malignant vertebral compression fractures compared with conventional T1 WI, T2 WI and fat suppressed contrast enhanced T1 WI in the Malaysian population.
    Matched MeSH terms: Fractures, Compression
  2. Das S, Palaniandy K, Abu Bakar A, Idris Z, Abdullah JM
    Cureus, 2020 Feb 03;12(2):e6850.
    PMID: 32181085 DOI: 10.7759/cureus.6850
    Cervical spine injuries are rare occurrences in children, especially the congenital anomalies of the atlas vertebra. Any injury involving the craniovertebral junction such as Jefferson fracture, is a valid cause for alarm due to the complex nature of the craniovertebral junction and the morbidity associated with it. We report the case of a 10-year-old male, who had failure of fusion of anterior arch of atlas due to the failure of formation of the anterior midline synchondrosis, and this mimicked a Jefferson fracture. If it was not for the peculiar absence of any corresponding evidence to suggest spinal injury, we might have mistaken this extremely rare but benign anomaly for a Jefferson fracture and subjected the patient to needless surgical treatment. Hence, it is concluded that keen clinical acumen and clear understanding of the developmental anatomy of these patients may be necessary to adequately manage them.
    Matched MeSH terms: Fractures, Compression
  3. Chai CS, Kho SS, Chan SK, Tee TT, Tie ST
    Clin Med (Lond), 2021 Jan;21(1):e114-e115.
    PMID: 33479093 DOI: 10.7861/clinmed.2020-0913
    Percutaneous vertebroplasty (PV) involves injection of polymethylmethacrylate bone cement into vertebral body for relief of pain and strengthening of bone in symptomatic vertebral compression fractures.Passage of bone cement into vertebral venous plexus and then into the lungs is a rare and serious complication of PV. The reported incidence up to 26%.We present an incidental finding of pulmonary cement embolism (PCE) after PV. A 68-year-old woman with history of PV 3 years previously for T11 osteoporotic fracture presented to us with cough for 3 weeks following choking on a fish bone.Chest X-ray showed left lower zone consolidation and a high-density opacity in a tubular branching pattern, corresponding to pulmonary arterial distribution. Contrasted computed tomography of the thorax showed segmental pulmonary cement embolism of both lungs and left lower lobe consolidation.She underwent bronchoscopy with findings of a purulent secretion from the left lower lobe. Her symptoms resolved after 2 weeks of antibiotics. She was managed conservatively for the PCE as she remained asymptomatic.This case highlights the need for a standard post-PV chest X-ray, as patients with cement embolisms can be completely asymptomatic. Measures to minimise the risk of pulmonary cement embolisms during PV need to be taken.
    Matched MeSH terms: Fractures, Compression*
  4. Chiu CK, Lisitha KA, Elias DM, Yong VW, Chan CYW, Kwan MK
    J Orthop Surg (Hong Kong), 2018 10 26;26(3):2309499018806700.
    PMID: 30352524 DOI: 10.1177/2309499018806700
    BACKGROUND: This prospective clinical-radiological study was conducted to determine whether the dynamic mobility stress radiographs can predict the postoperative vertebral height restoration, kyphosis correction, and cement volume injected after vertebroplasty.

    METHODS: Patients included had the diagnosis of significant back pain caused by osteoporotic vertebral compression fracture secondary to trivial injury. All the patients underwent routine preoperative sitting lateral spine radiograph, supine stress lateral spine radiograph, and supine anteroposterior spine radiograph. The radiological parameters recorded were anterior vertebral height (AVH), middle vertebral height (MVH), posterior vertebral height (PVH), MVH level below, wedge endplate angle (WEPA), and regional kyphotic angle (RKA). The supine stress versus sitting difference (SSD) for all the above parameters were calculated.

    RESULTS: A total of 28 patients (4 males; 24 females) with the mean age of 75.6 ± 7.7 years were recruited into this study. The mean cement volume injected was 5.5 ± 1.8 ml. There was no difference between supine stress and postoperative radiographs for AVH ( p = 0.507), PVH ( p = 0.913) and WEPA ( p = 0.379). The MVH ( p = 0.026) and RKA ( p = 0.005) were significantly less in the supine stress radiographs compared to postoperative radiographs. There was significant correlation ( p < 0.05) between supine stress and postoperative AVH, MVH, PVH, WEPA, and RKA. The SSD for AVH, PVH, WEPA, and RKA did not have significant correlation with the cement volume ( p > 0.05). Only the SSD-MVH had significant correlation with cement volume, but the correlation was weak ( r = 0.39, p = 0.04).

    CONCLUSIONS: Dynamic mobility stress radiographs can predict the postoperative vertebral height restoration and kyphosis correction after vertebroplasty for thoracolumbar osteoporotic fracture with intravertebral clefts. However, it did not reliably predict the amount of cement volume injected as it was affected by other factors.

    Matched MeSH terms: Fractures, Compression/diagnosis; Fractures, Compression/surgery
  5. Komang-Agung IS, Hydravianto L, Sindrawati O, William PS
    Malays Orthop J, 2018 Nov;12(3):6-13.
    PMID: 30555640 DOI: 10.5704/MOJ.1811.002
    Introduction: Percutaneous vertebroplasty (PV) is one of the available treatments for vertebral compression fracture (VCF). Polymethylmethacrylate (PMMA) is the most common bone substitute used in the procedure, but it has several disadvantages. Bioceramic material, such as hydroxyapatite (HA), has better biological activity compared to PMMA. The aim of this study was to find an optimal biomaterial compound which offers the best mechanical and biological properties to be used in PV. Materials and Methods: This was an experimental study with goat (Capra aegagrus hircus) as an animal model. The animals' vertebral columns were injected with PMMA-HA compound. Animal samples were divided into four groups, and each group received a different proportion of PMMA:HA compound. The mechanical and biological effects of the compound on the bone were then analysed. The mechanical effect was assessed by measuring the vertebral body's compressive strength. Meanwhile, the biological effect was assessed by analysing the callus formation in the vertebral body. Results: The optimal callus formation and compressive strength was observed in the group receiving PMMA:HA with a 1:2 ratio. Conclusion: A mixture of PMMA and HA increases the quality of callus formation and the material's compressive strength. The optimum ratio of PMMA:HA in the compound is 1:2.
    Matched MeSH terms: Fractures, Compression
  6. Looi, Collin Seng-Kim
    MyJurnal
    Background: To assess the effect of cement vertebroplasty on the activity of daily living of elderly patients who have sustained a vertebral osteoporotic fracture.
    Patients and Methods: Seven patients with clinically significant and radiologically proven osteoporotic vertebral compression fractures suitable to be treated with percutaneous cement vertebroplasty were recruited. Evaluation was based on pre- and postprocedure activity by clinical documentation (including interview) and by a self-developed questionnaire (including quality of life).
    Results: Following the procedure, 54% of patients resumed their activities of daily living with minimal pain while 46% of patients were able to do so without any pain (p
    Matched MeSH terms: Fractures, Compression
  7. Alizadeh M, Kadir MR, Fadhli MM, Fallahiarezoodar A, Azmi B, Murali MR, et al.
    J Orthop Res, 2013 Sep;31(9):1447-54.
    PMID: 23640802 DOI: 10.1002/jor.22376
    Posterior instrumentation is a common fixation method used to treat thoracolumbar burst fractures. However, the role of different cross-link configurations in improving fixation stability in these fractures has not been established. A 3D finite element model of T11-L3 was used to investigate the biomechanical behavior of short (2 level) and long (4 level) segmental spine pedicle screw fixation with various cross-links to treat a hypothetical L1 vertebra burst fracture. Three types of cross-link configurations with an applied moment of 7.5 Nm and 200 N axial force were evaluated. The long construct was stiffer than the short construct irrespective of whether the cross-links were used (p < 0.05). The short constructs showed no significant differences between the cross-link configurations. The XL cross-link provided the highest stiffness and was 14.9% stiffer than the one without a cross-link. The long construct resulted in reduced stress to the adjacent vertebral bodies and screw necks, with 66.7% reduction in bending stress on L2 when the XL cross-link was used. Thus, the stability for L1 burst fracture fixation was best achieved by using long segmental posterior instrumentation constructs and an XL cross-link configuration. Cross-links did not improved stability when a short structure was used.
    Matched MeSH terms: Fractures, Compression/surgery*
  8. Lee JS, Choi SJ, Kim L, Park IS, Han JY, Kim JM, et al.
    Malays J Pathol, 2019 Aug;41(2):213-222.
    PMID: 31427559
    INTRODUCTION: Anaplastic lymphoma kinase-positive (ALK+) anaplastic large cell lymphoma (ALCL) with a non-common pattern can be diagnostic challenging. Pathologists can be unavoidably and unintentionally blind to non-descript tumor cells in a lymphohistiocytic- (LH) or small-cell (SC)-pattern. We report a case of primary systemic ALK+ ALCL with a SC pattern that presented as secondary gastric lesions with a mixed LH and SC pattern that was masqueraded as inflammatory lesions.

    CASE REPORT: A 34-year-old woman with intractable epigastric pain was referred to have repeated endoscopy with biopsy. She was found to multiple gastric erosions and nodules that were diagnosed as inflammatory lesions both endoscopically and histologically. Meanwhile, she developed an acute onset of severe back pain associated with a pathologic compression fracture in the T3 thoracic vertebral body. Imaging studies disclosed a disseminated systemic disease involving abdominopelvic lymph nodes and cervical and thoracic vertebral bodies. The needle biopsy of the pelvic lymph node disclosed diffuse proliferation of monomorphic small round cells that were diffusely positive for CD30 and ALK. A diagnosis of ALK+ ALCL with a monomorphic SC pattern was rendered.

    DISCUSSION: A retrospective review of the gastric biopsies with the aid of immunohistochemistry enabled us to recognise the presence of lymphomatous infiltrates with a mixed LH and SC pattern in every piece of gastric biopsies that were repeatedly misdiagnosed as inflammatory lesions. This case illustrates a significant diagnostic pitfall of the LH- and SC-patterns in ALK+ ALCL, in which the tumour cells featuring lymphoid, plasmacytoid or histiocytoid appearance can be masqueraded as inflammatory cells.

    Matched MeSH terms: Fractures, Compression
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links