Displaying all 6 publications

Abstract:
Sort:
  1. Noraishah Othmanl, Nor Pa' iza M. Hasani, Juhari Mohd Yusof, Roslan Yahya, Mohd Amirul Syafiq
    MyJurnal
    Flow measurement is a critical element for liquid resources monitoring for various applications in many industrial systems. The purposes of the study are to determine the flow rate of liquid system in flow rig using radiotracer techniques and to compare the result with that obtained by the conventional flow meters. The flow rig consists of 58.7m long and 20cm diameter pipeline that can accommodate about 0.296m3 of liquid. Tap water was used as liquid flow in pipeline and conventional flow meters were also installed at the flow rig. Radiotracer was injected as a sharp pulse into the inlet p.peline. The pulse was monitored at the inlet and various points along the outlet pipeline using collimated scintillation detector. The peak to peak and total count methods were applied for radiotracer techniques and showed the comparable results with conventional flow meter.
    Matched MeSH terms: Flowmeters
  2. Mustapha, I., Takriff, M.S., Kamaruddin, S.K., Hassan, N.M., Zain, R.M.
    MyJurnal
    Electrical capacitance tomography (ECT) velocimetry technique was utilized in this study to quantify the flow structure of gas-liquid based on the ECT images. A new 8 electrodes sensor ECT has been successfully developed to provide 2D images in a cross section of pipeline. The ECT has been attentively applied in the test section of the flow rig for imaging the gas-liquid distribution. The inside diameter of ECT pipeline sensor is 100mm. Meanwhile, the flow rig consists of close loop of “CPVC” pipes that includes a pipe test section, two tanks of oil and water respectively and allows the working pressure up to 5 bars. Transparent pipe is used for visual monitoring. A portable Doppler flow meter that utilizes the ultrasonic signal has also been placed at the test section to measure the velocity. The images obtained by ECT show that the different flow patterns have been observed in the horizontal pipe during the experiment. The technique enables realization of the time and position at which particle density fluctuations with respect to dominant time-space levels pass through the pipeline.
    Matched MeSH terms: Flowmeters
  3. Idris AC, Saad MR, Zare-Behtash H, Kontis K
    Sensors (Basel), 2014;14(4):6606-32.
    PMID: 24721773 DOI: 10.3390/s140406606
    Scramjets have become a main focus of study for many researchers, due to their application as propulsive devices in hypersonic flight. This entails a detailed understanding of the fluid mechanics involved to be able to design and operate these engines with maximum efficiency even at their off-design conditions. It is the objective of the present cold-flow investigation to study and analyse experimentally the mechanics of the fluid structures encountered within a generic scramjet inlet at M = 5. Traditionally, researchers have to rely on stream-thrust analysis, which requires the complex setup of a mass flow meter, a force balance and a heat transducer in order to measure inlet-isolator performance. Alternatively, the pitot rake could be positioned at inlet-isolator exit plane, but this method is intrusive to the flow, and the number of pitot tubes is limited by the model size constraint. Thus, this urgent need for a better flow diagnostics method is addressed in this paper. Pressure-sensitive paint (PSP) has been applied to investigate the flow characteristics on the compression ramp, isolator surface and isolator sidewall. Numerous shock-shock interactions, corner and shoulder separation regions, as well as shock trains were captured by the luminescent system. The performance of the scramjet inlet-isolator has been shown to improve when operated in a modest angle of attack.
    Matched MeSH terms: Flowmeters
  4. Hashim SA, Amin MA, Nair A, Raja Mokhtar RA, Krishnasamy S, Cheng K
    Heart Lung Circ, 2018 May;27(5):e59-e63.
    PMID: 29246681 DOI: 10.1016/j.hlc.2017.11.011
    The revision of an internal mammary artery graft anastomosis because of a technical error can be time-consuming and complicated and may lead to complications. Here, we describe the technical details and our early experience of using a standard transit-time flowmeter to exclude technical errors and facilitate rapid decision making for anastomosis revision in an arrested heart during aortic cross-clamping in the absence of ultrasound guidance.
    Matched MeSH terms: Flowmeters*
  5. Mohd Yunos MAS, Hussain SA, Sipaun SM
    Appl Radiat Isot, 2019 Jan;143:24-28.
    PMID: 30368049 DOI: 10.1016/j.apradiso.2018.10.008
    The flow rate or fluid velocity measurement is important to maintain fluid flow quality performance in the systems. This study focuses on determination of volumetric flow rate measurement and to calibrate the conventional flowmeter using industrial radiotracer approach in quadrilateral gas-liquid bubble column reactor. In this work, two different radioisotopes which emit γ-ray have been chosen as radioactive tracer which is 99mTc produced from 99Mo/99mTc radioisotope generator and 198Au nanoparticle form neutron activation at research nuclear reactor TRIGA Mark II. Both radioisotopes representing liquid and solid tracer purposely designed for tracing liquid flow. The peak to peak radiotracer method known as pulse velocity method was applied to determine the volumetric flow rate. The radiation signals were monitored using 4 unit NaI scintillation detectors located at 4 different points nearby the inlet and outlet of the quadrilateral bubble column reactor process stream. The water volume inside the bubble column reactor was fixed at 0.04 m3 and liquid flow rates in this reactor were specified on installed flowmeter at different reference value which is 4 lpm, 8 lpm, and 12 lpm, respectively. The experimental result shows very good linearity and repeatability by following the theoretical equations with less uncertainty in volumetric flow rate measurement. The obtained results also validated the effectiveness of the proposed method for the installed flowmeter calibration efficiency.
    Matched MeSH terms: Flowmeters
Related Terms
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links