Displaying all 6 publications

Abstract:
Sort:
  1. Shah RP, Ding ZP, Ng AS, Quek SS
    Singapore Med J, 2001 Oct;42(10):473-6.
    PMID: 11874151
    Rupture of the sinus of valsalva (RSOV) is an uncommon condition with a variety of manifestations ranging from an asymptomatic murmur to cardiogenic shock. This retrospective 10-year review (1985-1995) of 18 patients from a single institution revealed that 6 (33%) were female and 12 (67%) were male with a mean age of 37.6 +/- 13.4 years and that 72% were Chinese by ethnic descent with the remaining 28% being Malay. Eight patients (44.4%) presented with an asymptomatic murmur, 4 (22.2%) with acute chest pain, 4 (22.2%) with mild heart failure, 2 (11.1%) with severe heart failure, and 2 (11.1%) with cardiogenic shock. Rupture of the right aneurysmal coronary cusp (RCC) made up 15 (83.3%) while those of the non-coronary cusp (NCC) made up the remaining. Most of the RCC ruptures were directed into the right ventricle and all of the NCC ruptures were into the right atrium. Ventricular septal defects (VSDs) were found in 9 (50%) of the patients, (although detected by echocardiography in only one third of those patients), aortic regurgitation in 6 (33.3%) and aortic valve vegetations in 2 (11.1%). Echocardiography was found to be accurate in diagnosing RSOVs with 100% diagnostic accuracy after 1990 with four misdiagnoses before 1990. Of these four patients, two were misdiagnosed as having VSDs, one as having a coronary arteriovenous fistula and one as having a patent ductus arteriosus. The anatomical structure of the "windsock" was seen in 64% of the patients who were correctly diagnosed. The pattern of colour flow and spectral Doppler was seen in all patients and helped to localise the site of rupture and the direction of flow. In summary, echocardiography is a simple and accurate way of diagnosing and defining RSOVs and is the imaging modality of choice.
    Matched MeSH terms: Echocardiography, Doppler, Color*
  2. Kunwar MA, Muhammad I, Khan MN, Sumreen B, Soomro NA, Naseeb K, et al.
    Cureus, 2020 Jun 03;12(6):e8419.
    PMID: 32642335 DOI: 10.7759/cureus.8419
    Background Acute myocardial infarction (MI) is the leading cause of worldwide cardiac morbidities and mortalities. Mitral regurgitation (MR) is a common complication of MI. The severity of ischemic MR (IMR) can range widely, both clinically and hemodynamically. Mitral valve (MV) repair by lifting annuloplasty is a surgical procedure used to correct the pathology of IMR. The immediate outcomes of this technique have not yet been determined. The present study, therefore, evaluated the immediate results of MV annuloplasty performed to complement MV repair in patients with IMR. Methodology All adult patients with IMR who underwent lifting posterior mitral annuloplasty (LPMA) plus concomitant coronary artery bypass grafting (CABG) were included. Immediate outcomes were evaluated by transesophageal color Doppler echocardiography. The frequency of successful outcomes was compared in patients with different baseline characteristics. Results Posterior mitral annuloplasty was successful in 93.1% of patients, including in 92.8% of men and 94.1% of women. The percentages of successful immediate outcomes differed significantly in patients with and without diabetes and hypertension, and in patients with two- and three-vessel disease. Conclusion LPMA resulted in a high percentage of successful immediate outcomes in patients with IMR. Further studies should compare rates of immediate, intermediate, and late outcomes of this technique.
    Matched MeSH terms: Echocardiography, Doppler, Color
  3. Jung HJ, Kwon WK, Lee SJ, Mohamed N, Shin BM, Lee J, et al.
    BMC Anesthesiol, 2016 10 04;16(1):83.
    PMID: 27716083
    BACKGROUND: This study reports the efficacy of intraoperative transesophageal echocardiography (TEE) for evaluation of high take-off coronary ostia and proximal coronary arterial flows as an alternative to preoperative coronary angiography.

    CASE PRESENTATION: In a 65-year old male undergoing the bicuspid aortic valve (BAV) repair and the extensive remodeling of dilated sinus and tubular junction, and preoperative coronary angiography were unsuccessfully completed due to an allergic reaction to the contrast medium. Intraoperative TEE by employing various 3-dimensional volume images of coronary ostia and Doppler tracings of the coronary arterial flows enabled a thorough pre-procedural evaluation of the high take-off coronary arteries and post-procedural evaluation by confirming the absence of any compromise in coronary arterial flow.

    CONCLUSION: In the present case, intraoperative application of various TEE imaging modalities enabled comprehensive evaluation of high-taking off coronary artery, as an alternative to preoperative coronary angiography, in a patient undergoing an extensive aortic valve and aortic root repair procedure.

    Matched MeSH terms: Echocardiography, Doppler, Color/methods
  4. Abdelbasit MA, Alwi M, Kandavello G, Che Mood M, Samion H, Hijazi ZM
    Catheter Cardiovasc Interv, 2015 Jul;86(1):94-9.
    PMID: 25675888 DOI: 10.1002/ccd.25878
    OBJECTIVES: To evaluate the feasibility, safety, and efficacy of the Occlutech® PDA occluder for closure of patent ductus arteriosus (PDA).

    BACKGROUND: The Occlutech® PDA occluder is novel, self-shaping Nitinol wire device with PET (polyethylene terephthalate) patches integrated into the shank of the device to assure a better obturation of the ductus. The Occlutech® PDA occluder has undergone two design modifications.

    METHODS: A prospective, non-randomized pilot study was started in November 2011. Thirty-three patients were included until April 2013. Patients weighing <6 kg or those with associated cardiac anomalies that required surgery were excluded. All patients were followed up by transthoracic echocardiography at 24 hr, 30 days, 90 days, 180 days, and 360 days after implantation. Residual shunt, left pulmonary artery (LPA) and descending aortic velocities were among the parameters assessed. All occluders were delivered via 6-8 F long sheaths and PDA closures were performed following standard techniques.

    RESULTS: Thirty three patients (20 female/13 male), with a median age of 2 years (6 month to 38 years), and median weight of 9.3 kg (6-69.2 kg) were included. The narrowest median PDA diameter was 3mm (1.8-5.8 mm). All the 33 patients were closed successfully using Occlutech ductal occluder, 16 patients (48.4%) had immediate and complete closure on angiography. Within 24 hr, color Doppler revealed complete closure in 27patients (81.8%), 32patients (97%) at 30 days, and in 100% of patients at 90 days. All patients with a large PDA had immediate residual shunt which was closed at the 90-day follow-up. There was no device embolization, hemolysis, or obstruction to the LPA or descending aorta.

    CONCLUSION: The new Occlutech® PDA is safe and effective. In patients with a large PDA complete closure tended to take longer time.

    Matched MeSH terms: Echocardiography, Doppler, Color
  5. Qureshi AU, Latiff HA, Sivalingam S
    Cardiol Young, 2014 Aug;24(4):756-9.
    PMID: 24016801 DOI: 10.1017/S1047951113001200
    Incomplete involution of valve of systemic venous sinus can present across a spectrum of anatomical lesions ranging from eustachian valve to division of right atrium (cor triatriatum dexter) with overlapping features. We present the case of a neonate presenting with cyanosis, having persistent valve of systemic venous sinus with anatomical details of the redundant tissue in right atrium suggesting an intermediate form between Chiari network and division of right atrium.
    Matched MeSH terms: Echocardiography, Doppler, Color
  6. Jin-Poi T, Shatriah I, Ng SL, Zurkurnai Y, Yunus R
    JAMA Ophthalmol, 2013 Feb;131(2):263-5.
    PMID: 23411903 DOI: 10.1001/jamaophthalmol.2013.587
    Matched MeSH terms: Echocardiography, Doppler, Color
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links