Displaying all 9 publications

Abstract:
Sort:
  1. LLEWELLYN-JONES D
    Med J Malaya, 1958 Sep;13(1):65-9.
    PMID: 13589372
    Matched MeSH terms: Dystocia/etiology*
  2. Ng KH, Sivanesan S
    Med J Malaysia, 1973 Dec;28(2):118-9.
    PMID: 4276267
    Matched MeSH terms: Dystocia/etiology*
  3. Mansor A, Arumugam K, Omar SZ
    Eur J Obstet Gynecol Reprod Biol, 2010 Mar;149(1):44-6.
    PMID: 20042263 DOI: 10.1016/j.ejogrb.2009.12.003
    To determine if shoulder dystocia can be predicted in babies born weighing 3.5 kg or more.
    Matched MeSH terms: Dystocia/etiology*; Dystocia/epidemiology*
  4. Sinnathuray TA
    Med J Malaysia, 1979 Sep;34(1):80-5.
    PMID: 542158
    Matched MeSH terms: Dystocia/prevention & control
  5. Sargunam PN, Bak LLM, Tan PC, Vallikkannu N, Noor Azmi MA, Zaidi SN, et al.
    BMC Pregnancy Childbirth, 2019 Dec 11;19(1):493.
    PMID: 31829138 DOI: 10.1186/s12884-019-2602-2
    BACKGROUND: Prolonged latent phase of labor is associated with adverse maternal and neonatal outcomes. Preliminary data indicate that labor induction for prolonged latent phase may reduce cesarean delivery. We performed a study powered to Cesarean delivery to evaluate labor induction compared to expectant management in full term nulliparas hospitalized for persistent contractions but non-progressive to established labor after an overnight stay.

    METHODS: From 2015 and 2017, nulliparas, ≥ 39 weeks' gestation with prolonged latent phase of labor (persistent contractions after overnight hospitalization > 8 h), cervical dilation ≤3 cm, intact membranes and reassuring cardiotocogram were recruited. Participants were randomized to immediate induction of labor (with vaginal dinoprostone or amniotomy or oxytocin as appropriate) or expectant management (await labor for at least 24 h unless indicated intervention as directed by care provider). Primary outcome measure was Cesarean delivery.

    RESULTS: Three hundred eighteen women were randomized (159 to each arm). Data from 308 participants were analyzed. Cesarean delivery rate was 24.2% (36/149) vs. 23.3%, (37/159) RR 1.0 95% CI 0.7-1.6; P = 0.96 in induction of labor vs. expectant arms. Interval from intervention to delivery was 17.1 ± 9.9 vs. 40.1 ± 19.8 h; P 

    Matched MeSH terms: Dystocia/therapy*
  6. LLEWELLYN-JONES D
    J Obstet Gynaecol Br Commonw, 1965 Apr;72:196-202.
    PMID: 14273096
    Matched MeSH terms: Dystocia*
  7. Grace Ng YH, Aminuddin AA, Tan TL, Kuppusamy R, Tagore S, Yeo GSH
    Arch Gynecol Obstet, 2021 May 11.
    PMID: 33973051 DOI: 10.1007/s00404-021-06090-y
    OBJECTIVE: To evaluate the safety in the first 12 h, efficacy and maternal satisfaction of a double balloon catheter (DBC) with vaginal prostaglandin (PGE) for induction of labour (IOL).

    METHODS: We conducted a multicentre randomised controlled study of 420 patients from 1st January 2016 to 31st December 2017 to evaluate the use of DBC in IOL in an Asian population looking at the adverse effects in the first 12 h after insertion. Women were assigned randomly to cervical ripening with either a DBC or a prostaglandin pessary. The adverse events in the 12 h after DBC or first prostaglandin inserted, the efficacy of a DBC to a prostaglandin in labour induction and maternal satisfaction were evaluated.

    RESULTS: There were significantly less women with uterine hyperstimulation in the DBC (2 vs 24, p ≤ 0.0001) compared to the prostaglandin group. There were no women with uterine hyperstimulation and non-reassuring foetal status in the DBC while there were 5 women with uterine hyperstimulation and foetal distress in the prostaglandin group. Use of entonox was significantly less in the DBC group (p = 0.009). There were no significant differences in both groups in caesarean section, vaginal deliveries and time to delivery, although significant less time was needed to achieve cervical os dilation more than 4 cm in the DBC group (p ≤ 0.0001). Neonatal birth outcomes were similar. Women's pain scores were similar for both methods. 80.1% of women allocated the DBC and 76.8% of women allocated the PGE were keen to recommend their method of induction.

    CONCLUSION: Double balloon catheter remains a good alternative method for inducing women in view of a good safety profile with low risk of hyperstimulation and high maternal satisfaction.

    CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT02620215.

    Matched MeSH terms: Dystocia
  8. Awang, M.S., Abdul Razak, A.H., Che Ahmad, A., Mohd Rus, R.
    MyJurnal
    Introduction: The purpose of this study is to identify the incidence of clavicle fractures in newborn
    associated with fetal, maternal and process of deliveries in Kuantan General Hospital from June 2012 until
    January 2014. This study is to determine epidemiological data of clavicle fractures, maternal and baby risk
    factors associated with clavicle fractures of newborn and its’ outcome.

    Methods: This is a prospective
    study. 13 patients were identified to fulfill the inclusion criteria of the study. The data of
    sociodemographic, associated fetal and maternal risk factors and the outcomes were recorded using
    proforma. The statistical data analysis was done using SPSS 12.0.

    Results: Out of 20,257 live births at our
    centre during the study period, 13 infants were diagnosed to have clavicle fractures, giving an incidence of
    0.64 per 1000 live births. There were 5 (38.5%) left, 7 (53.8%) right and one (7.7%) bilateral fracture. All
    fractures located at the mid shaft of the clavicle and none have associated brachial plexus injuries. All
    infants were delivered through vaginal delivery (61.5%); five through assisted delivery (instrumental); 2
    (15.4%) forcep and 3 (23.1%) vacuum. Two of the babies developed shoulder dystocia. The average birth
    weight was 3371 grams (SD 0.269) and mean gestational age was 38.7 weeks (SD 1.16). Five of the mothers
    (38.5%) were primigravida and eight (61.5%) were multigravida in which,7 (53.8%)were healthy without
    other co-morbidty, 5 (38.5%) having gestational diabetis and one (7.7%) hypertension. The average maternal
    weight was 62.0 kg and height 1.58 metres with average BMI of 24.16 (3.29SD). All eventually had a
    complete recovery at 6 weeks with clinical and radiological evident of fracture union.

    Conclusions: In
    conclusion, all patients with clavicle fractures were found following vaginal delivery. There were no
    associations between neonatal clavicle fractures with maternal or baby risk factors. All fractures healed
    without any complications.
    Matched MeSH terms: Dystocia
  9. Ganeshan M, Bujang MA, Soelar SA, Karalasingam SD, Suharjono H, Jeganathan R
    J Obstet Gynaecol India, 2018 Jun;68(3):173-178.
    PMID: 29895995 DOI: 10.1007/s13224-017-1000-9
    Aims: The aim of this study is to compare obstetric outcomes between overweight and class 1 obesity among pregnant women in their first pregnancy based on WHO's BMI cut-offs and the potential public health action points identified by WHO expert consultations specific for high-risk population such as Asians.

    Methods: This is a retrospective cohort review of data obtained from the Malaysian National Obstetrics and Gynaecology Registry between the year 2010 and year 2012. All women in their first pregnancy with a booking BMI in their first trimester were included in this study. The association between BMI classifications as defined by the WHO cut-offs and the potential public health action points identified by WHO expert consultations towards adverse obstetric outcomes was compared.

    Results: A total of 88,837 pregnant women were included in this study. We noted that the risk of adverse obstetric outcomes was significantly higher using the public health action points identified by WHO expert consultations even among the overweight group as the risk of stillbirths was (OR 1.2; 95% CI 1.0,1.4), shoulder dystocia (OR 1.9; 95% CI 1.2,2.9), foetal macrosomia (OR 1.8; 95% CI 1.6,2.0), caesarean section (OR 1.9; 95% CI 1.8,2.0) and assisted conception (OR 1.9; 95% CI 1.6,2.1).

    Conclusion: A specifically lower BMI references based on the potential public health action points for BMI classifications were a more sensitive predictor of adverse obstetric outcomes, and we recommend the use of these references in pregnancy especially among Asian population.

    Matched MeSH terms: Dystocia
Related Terms
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links