METHODS: A randomized controlled trial was carried out in a university hospital in Malaysia. Women with lifestyle-controlled gestational diabetes scheduled to receive clinically indicated antenatal corticosteroids (dexamethasone) were randomized to 12-mg 12 hourly for one day (2 × 12-mg) or 6-mg 12-hourly for two days (4 × 6-mg). 6-point (pre and 2-h postprandial) daily self-monitoring of capillary blood sugar profile for up to 3 consecutive days was started after the first dexamethasone injection. Hyperglycemia is defined as blood glucose pre-meal ≥ 5.3 or 2 h postprandial ≥ 6.7 mmol/L. The primary outcome was a number of hyperglycemic episodes in Day-1 (first 6 BSP points). A sample size of 30 per group (N = 60) was planned.
RESULTS: Median [interquartile range] hyperglycemic episodes 4 [2.5-5] vs. 4 [3-5] p = 0.3 in the first day, 3 [2-4] vs. 1 [0-3] p = 0.01 on the second day, 0 [0-1] vs. 0 [0-1] p = 0.6 on the third day and over the entire 3 trial days 7 [6-9] vs. 6 [4-8] p = 0.17 for 6-mg vs. 12-mg arms, respectively. 2/30 (7%) in each arm received an anti-glycemic agent during the 3-day trial period (capillary glucose exceeded 11 mmol/L). Mean birth weight (2.89 vs. 2.49 kg p
METHODS: This prospective, randomized controlled, open-label trial evaluated 50 women with insulin-treated GDM randomized to either retrospective CGM (6-day sensor) at 28, 32 and 36 weeks' gestation (Group 1, CGM, n = 25) or usual antenatal care without CGM (Group 2, control, n = 25). All women performed seven-point capillary blood glucose (CBG) profiles at least 3 days per week and recorded hypoglycaemic events (symptomatic and asymptomatic CBG
MATERIALS AND METHODS: Seventy-four participants, with type 1 (T1D, n = 24), type 2 (T2D, n = 11), or gestational (n = 39) diabetes, were enrolled across 13 sites (9 in United Kingdom, 4 in Austria). Average gestation was 26.6 ± 6.8 weeks (mean ± standard deviation), age was 30.5 ± 5.1 years, diabetes duration was 13.1 ± 7.3 years for T1D and 3.2 ± 2.5 years for T2D, and 49/74 (66.2%) used insulin to manage their diabetes. Sensors were worn for up to 14 days. Sensor glucose values (masked) were compared with capillary SMBG values (made at least 4 times/day).
RESULTS: Clinical accuracy of sensor results versus SMBG results was demonstrated, with 88.1% and 99.8% of results within Zone A and Zones A and B of the Consensus Error Grid, respectively. Overall mean absolute relative difference was 11.8%. Sensor accuracy was unaffected by the type of diabetes, the stage of pregnancy, whether insulin was used, age or body mass index. User questionnaires indicated high levels of satisfaction with sensor wear, system use, and comparison to SMBG. There were no unanticipated device-related adverse events.
CONCLUSIONS: Good agreement was demonstrated between the FreeStyle Libre System and SMBG. Accuracy of the system was unaffected by patient characteristics, indicating that the system is safe and accurate to use by pregnant women with diabetes.