METHODS: Retrospective data from clinical worksheets given to participants during two implant courses held between the periods of 2013 to 2014 were evaluated. A total of 61 implants were considered based on the inclusion criteria. The effects of parameters such as implant diameter, implant length, age, gender, implant location and osteotomy protocol on ISQ values were analyzed.
RESULTS: Mean ISQ value for all implants was 67.21±9.13. Age of patients (P=0.016) and location of implants (P=0.041) had a significant linear relationship with the ISQ values. Within the age limit of the patients in this study, it was found that an increase in one year of patient's age results in 0.20 decrease in ISQ value (95% CI: -0.36, -0.04). However, placing an implant in the posterior maxilla may negatively affect the ISQ with a likely decrease in primary stability by 6.76 ISQ value (95% CI: -13.22, -0.30).
CONCLUSIONS: The results suggest that the mean ISQ achieved by the participants were comparable with the range reported for this particular type of implants. The patient's age and location of implants were elucidated as the determinant factors of primary implant stability.
PURPOSE: The purpose of this systematic review of the literature and meta-analysis was to analyze the data on the survival of dental implants in patients with HIV.
MATERIAL AND METHODS: A search for relevant articles published up to November 2019 was performed in PubMed/Medline and Cochrane databases, Clinicaltrials.gov, and Google Scholar. Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines were adopted for the conduct of the systematic review. The most pertinent data were extracted and pooled for qualitative and quantitative analyses with 95% confidence intervals. Heterogeneity was analyzed by using I-squared statistics.
RESULTS: A total of 8 studies involving 411 individuals with HIV and 1109 implants were included in the meta-analysis. The mean follow-up period was 2.8 years. A pooled estimate of 95% of implant survival rate with 95% confidence interval(92% to 96%) was noted. Heterogeneity across the 8 studies was found to be 41% with moderate true variability.
CONCLUSIONS: This systematic review demonstrated that HIV infection does not pose a serious threat to implant survival on short-term evaluation, but the evidence is of low quality.
MATERIALS AND METHODS: In this study, 20 implant sites in patients were selected. Ridge mapping was done through a vacuum press template at three buccal (B1, B2, B3), three lingual (L1, L2, L3), and one crestal (C) points for each implant site. Readings were transferred onto the cast, and surgical guides were fabricated for implant placement. Postoperative cone beam computerized tomography (CBCT) was done to assess planned and achieved implant position. Comparison was done between soft tissue depths and implant distance from the crest of alveolar bone determined by the ridge mapping technique with measurements done on CBCT. The points used for ridge mapping were used as the reference for measurements. The data were analyzed using paired t test. p < 0.05 was considered to be statistically significant.
RESULTS: On comparing the mean values of soft tissue depths from the ridge mapping and CBCT data, insignificant differences were found at B1, B2, L1, L2, L3, and C, but significant differences were found at B3. On comparing the implant distances from alveolar bone from both the data, insignificant differences were found at B, B2, B3, L1, L2, and L3 and significant difference was found at the crest in the mean values.
CONCLUSION: Under the limitations of the above study, it can be concluded that a simple chairside procedure like ridge mapping can be used as an effective way for guided implant placement in sufficient available alveolar bone.
PURPOSE: The purpose of this observational study was to measure the prevalence of the presence of the anterior loop and to estimate sex and ethnicity-related variations in anterior loop length in the Malaysian population.
MATERIAL AND METHODS: A total of 100 cone beam computed tomography (CBCT) Digital Imaging and Communications in Medicine (DICOM) files were selected from a pool of 810 ongoing or completed patients in 3 different ethnic groups: Malay (33), Indian (33), and Chinese (34). The DICOM data were imported into commercial software. The IAN was traced with software along with the anterior loop and part of the incisive nerve. The vertical length of the nerve was estimated from the canal to the opening of the mental foramen from the cross-sectional view and translated to the panoramic view. Measurement was made from this point to the most anterior point of the anterior loop by following the trajectory of the nerve and was repeated on the opposite side. A 2-way mixed analysis of variance (ANOVA) test was carried out to evaluate the sex- and ethnicity-related variations (α=.05).
RESULTS: The anterior loop was present in 94% of the 100 participants. Overall anterior loop length (AnLL) ranged between 0.73 and 7.99 mm with a mean length of 3.69 ±1.75 mm on the left side and 3.85 ±1.73 mm on the right side. Among all participants, no statistically significant differences were found between the left and right sides of the mandible (P=.379). Overall, no significant main effect of ethnicity (P=.869) or sex (P=.576) was found on AnLL measurements. Also, with multiple comparisons, no significant effect was found between each pair of ethnic groups. Men in all 3 ethnic groups had greater AnLL than women.
CONCLUSIONS: The anterior loop was present in 94% of the 100 participants among the 3 major ethnic groups of Malaysia. Overall AnLL ranged between 0.73 and 7.99 mm and mean lengths of 3.69 ±1.75 mm on the left side and 3.85 ±1.73 mm on the right side, with no significant ethnicity- or sex-related variations.
MATERIALS AND METHODS: Twenty-one patients with implants were included in this study and implants were assessed by resonance frequency analysis (RFA). Bone levels of the implants were assessed by measuring mesial and distal bone levels from the periapical radiograph, and soft tissue was assessed from probing depth using a periodontal probe. Implants were assessed for stability and probing depth at pre-loading, at 3 months and 6 months post-loading. RFA and probing depth were statistically compared from different time points. Correlation of probing depth and marginal bone loss with implant stability was also determined.
RESULTS: The average change in implant stability quotient (ISQ) measurements from pre-loading to 6 months post-loading was found to be statistically significant (p <0.005). The average probing depth reduced from 1.767 mm at pre-loading to 1.671 mm at post-loading 3 months, and 1.600 mm at post-loading 6 months. At 6 months of function, radiographic examination yielded 0.786 mm mesial bone loss and 0.8 mm distal bone loss. It was found to be statistically significant (p <0.005) but within an acceptable range. No significant correlation was found between implant stability and bone loss; and implant stability and probing depth.
CONCLUSION: The study revealed an increasing trend in implant stability values with the time that indicates successful osseointegration. Increasing mean values for mesial and distal bone loss were also found.
CLINICAL SIGNIFICANCE: The success of dental implants is highly dependent on the quality of bone and implant-bone interface, i.e., osseointegration. The most important factors that influence the survival rate of an implant is initial stability. The present study found the changes in the peri-implant hard and soft tissues and implant stability. This article, while being a prospective study, may show the evidence of successful osseointegration by increasing trend in implant stability (RFA) values with time which can help to the clinician in the long-term management of implants.
MATERIAL AND METHODS: Sandblasted and cleansed planar titanium specimens with a size of 5 × 5 × 1 mm were coated on one side with 0.25 vol% eicosapentaenoic acid (EPA). The other side of the specimens was kept highly polished (the control side). These specimens were inserted in rabbit mandibles. Twelve rabbits were randomly assigned into three study groups (n = 4). The rabbits were sacrificed at 4, 8, and 12 weeks. The harvested specimens with the implants were assessed for new bone formation on both sides of the implant using CBCT, conventional radiographs, and the biaxial pullout test. The results were statistically analyzed by a nonparametric Kruskal-Wallis test and Friedman's test as multiple comparisons and by Brunner-Langer nonparametric mixed model approach (R Software).
RESULTS: A significant osteoconductive bone formation was found on the EPA-coated Ti implant surface (P < 0.05) at 8 weeks when compared to the polished surface (control). Biaxial pullout test results showed a significant difference (P < 0.05) after 8 and 12 weeks with a maximum force of 243.8 N, compared to 143.25 N after 4 week.
CONCLUSION: EPA implant coating promoted osteoconduction on the Ti implant surfaces, enhancing the anchorage of the implant to the surrounding bone in white New Zealand rabbits.
MATERIAL AND METHODS: Thirty-four patients (mean age 60.70 ± 8.7 years) received telescopic crown or locator attachments for ISOD and completed OHIP-14 (Malaysian version) and DS questionnaires, at baseline (T0 ) with new conventional complete dentures (CCD) and 3 months (T1 ) and 3 years (T2 ) after ISOD conversion. Mandibular bone volume was calculated from cone beam computed tomography (CBCT) datasets using Mimics software. Mean changes (MC) in OHIP-14 and DS at intervals were analyzed using the Wilcoxon signed-rank test and effect size (ES). The association of bone volume, implant attachment type, and other patient variables with the change in OHIP-14 and DS were determined using multivariate linear regression analysis.
RESULTS: The MC in OHIP-14 and DS scores from T0 to T1 and T2 showed significant improvement with moderate and large ES, respectively. Regression analyses for the change in OHIP-14 score from T0 to T2 showed significant association with implant attachment type (P = 0.043), bone volume (P = 0.004), and baseline OHIP-14 (P = 0.001), while for DS, the association was only significant with baseline DS score (P = 0.001).
CONCLUSION: Improvement in patients' OHRQoL and satisfaction with ISOD was associated with their baseline ratings. Mandibular bone volume had a stronger association for improvement in OHRQoL compared to type of attachment.