Displaying publications 1 - 20 of 87 in total

Abstract:
Sort:
  1. Rathakrishnan A, Sekaran SD
    Expert Opin Med Diagn, 2013 Jan;7(1):99-112.
    PMID: 23530846 DOI: 10.1517/17530059.2012.718759
    Dengue is of major concern around the world. Having no pathognomonic features that reliably distinguish it from other febrile illnesses, laboratory diagnosis is important for confirmation. Ideally, a dengue diagnostic test should be sensitive, specific and applicable from the onset of disease to 10 days post-infection.
    Matched MeSH terms: Dengue Virus/isolation & purification*
  2. Rohani A, Zamree I, Joseph RT, Lee HL
    PMID: 19058573
    A study was conducted to examine the persistency of transovarial dengue virus type 2 (DEN-2) in a Selangor strain of Aedes aegypti mosquitoes. Two hundred 4-5 day old female mosquitoes were fed with blood containing dengue virus. The infected mosquitoes were reared to the 7th generation; each generation was screened for the virus using immunological staining methods. The virus was detectable until the 5th generation but absent in the 6th and the 7th generations. Therefore, dengue virus type 2 can be transmitted transovarially in Aedes aegypti mosquitoes until the fifth generation under laboratory conditions.
    Matched MeSH terms: Dengue Virus/isolation & purification*
  3. Tan AH, Linn K, Sam IC, Tan CT, Lim SY
    Parkinsonism Relat Disord, 2015 Feb;21(2):160-1.
    PMID: 25443556 DOI: 10.1016/j.parkreldis.2014.11.009
    Matched MeSH terms: Dengue Virus/isolation & purification*
  4. Aeinehvand MM, Ibrahim F, Harun SW, Djordjevic I, Hosseini S, Rothan HA, et al.
    Biosens Bioelectron, 2015 May 15;67:424-30.
    PMID: 25220800 DOI: 10.1016/j.bios.2014.08.076
    Dengue is the current leading cause of death among children in several Latin American and Asian countries. Due to poverty in areas where the disease is prevalent and the high cost of conventional diagnostic systems, low cost devices are needed to reduce the burden caused by dengue infection. Centrifugal microfluidic platforms are an alternative solution to reduce costs and increase the availability of a rapid diagnostic system. The rate of chemical reactions in such devices often depends on the efficiency of the mixing techniques employed in their microfluidic networks. This paper introduces a micromixer that operates by the expansion and contraction of a microballoon to produce a consistent periodical 3D reciprocating flow. We established that microballoons reduced mixing time of 12 μl liquids from 170 min, for diffusional mixing, to less than 23 s. We have also tested the effect of the microballoon mixers on the detection of the dengue virus. The results indicate that employing a microballoon mixer enhances the detection sensitivity of the dengue virus by nearly one order of magnitude compared to the conventional ELISA method.
    Matched MeSH terms: Dengue Virus/isolation & purification*
  5. Mia MS, Begum RA, Er AC, Abidin RD, Pereira JJ
    Asian Pac J Trop Med, 2013 Jun;6(6):462-6.
    PMID: 23711707 DOI: 10.1016/S1995-7645(13)60075-9
    OBJECTIVE: To analyze trends of dengue incidences and deaths in Malaysia from 2000 to 2010 as well as the predominant dengue virus serotypes during the last decade.

    METHODS: We used the national data on annual reported cases, deaths, incidence rate, mortality rate, and case fatality rate of dengue fever (DF) and dengue hemorrhagic fever (DHF) as well as dengue virus serotypes prevalent in Malaysia during the last decade. Trend/ regression lines were fitted to investigate the trend of dengue incidences and deaths due to the disease for a 11-year period (2000-2010). For the distribution of national incidence rate, mortality rate, and case fatality rate of DF and DHF, descriptive statistics using mean and 95% confidence intervals (CI 39) for means, and range were applied.

    RESULTS: The number of dengue cases and number of deaths have increased, on average, by 14% and 8% per year respectively. The average annual incidence rate of DF per 100 000 populations was higher as compared to that of DHF. Conversely, the yearly mean mortality rate of DHF per 100 000 populations was greater than that of DF. The simultaneous circulation of all four dengue serotypes has been found in Malaysia. But a particular dengue virus serotype predominates for at least two years before it becomes replaced by another serotype.

    CONCLUSIONS: The dengue situation in Malaysia has worsened with an increasing number of reported cases and deaths during the last decade. The increasing trend of dengue highlights the need for a more systematic surveillance and reporting of the disease.

    Matched MeSH terms: Dengue Virus/isolation & purification*
  6. Cardosa MJ, Noor Sham S, Tio PH, Lim SS
    PMID: 3238470
    A dot enzyme immunoassay (DEIA) was used to determine the levels of antibody to dengue 3 virus in the acute and convalescent sera of febrile patients with a clinical diagnosis of dengue fever or dengue haemorrhagic fever. The antibody titres were compared with titres determined by the haemagglutination inhibition (HI) test. The results of the study showed that, besides being more simple to perform, the DEIA is in order of magnitude more sensitive than the HI test. Furthermore, the data suggest that it is possible to use a single dilution as a cutoff point to predict with reasonable accuracy, if a patient has had a recent dengue infection. The DEIA test for antibodies to dengue virus is an appropriate technology highly suitable for rapid diagnosis and surveillance in developing countries.
    Matched MeSH terms: Dengue Virus/isolation & purification*
  7. Du YH, Li Y, Wang RL, Wang HF, Su J, Xu BL, et al.
    Zhonghua Yu Fang Yi Xue Za Zhi, 2018 Nov 06;52(11):1164-1167.
    PMID: 30419702 DOI: 10.3760/cma.j.issn.0253-9624.2018.11.013
    Objective: To confirm the laboratory diagnosis of dengue bordline cases reported in Henan Province and trace its origin from molecular level in 2017. Methods: The study samples were blood samples (3-5 ml), which came from 8 suspected cases of dengue fever reported in the 2017 direct reporting system of Henan provincial infectious disease monitoring network. Meanwhile, case investigation was conducted according to National dengue fever surveillance programme. Serum were separated from blood samples and tested for Dengue NS1 antigen, IgM & IgG antibodies, and dengue RNA. According to dengue diagnosis criteria, confirmed cases were identified by testing results. Samples carried dengue RNA performed for real-time PCR genotyping and amplification of E gene. Then, the amplicons were sequenced and homological and phylogenetic analyses were constructed. Results: 8 serum samples of suspected dengue cases were collected in Henan Province, 2017. Six of them were diagnosed as dengue confirmed cases. All the dengue confirmed cases belonged to outside imported cases, 5 of them were positive by dengue RNA testing. Genotyping results showed there were 1 DENV1 case, 2 DENV2 cases and 2 DENV3 cases. A DENV2 case and a DENV3 case of this study were traced its origin successfully. The sequence of Pakistan imported DENV2 case belongs to cosmopolitan genotype, which was the most consistent with Pakistan's DENV2 KJ010186 in 2013 (identity 99.0%). The sequence of Malaysia imported DENV3 case belongs to genotype I, which was the most consistent with Singapore's DENV3 KX224276 in 2014(identity 99.0%). Conclusion: The laboratory diagnosis and molecular traceability of dengue cases in Henan Province in 2017 confirmed that all cases were imported and did not cause local epidemics.
    Matched MeSH terms: Dengue Virus/isolation & purification
  8. Mazlan NF, Tan LL, Karim NHA, Heng LY, Jamaluddin ND, Yusof NYM, et al.
    Talanta, 2019 Jun 01;198:358-370.
    PMID: 30876573 DOI: 10.1016/j.talanta.2019.02.036
    An optical genosensor based on Schiff base complex (Zn2+ salphen) DNA label and acrylic microspheres (AMs) as polymer support of the capturing DNA probe (cpDNA) was developed for dengue virus serotype 2 (DEN-2) detection via reflectance spectrophotometric method. The solid-state optical DNA biosensor showed high selectivity and specificity up to one-base mismatch in the target DNA sequence owing to the salphen chemical structure that is rich in localized electrons, and allowed π-π stacking interaction between stacked base pairs of double-stranded DNA (dsDNA). The reflectometric DNA microsensor demonstrated a broad linear detection range towards DEN-2 DNA from 1 × 10-15 M to 1 × 10-3 M with a low limit of detection (LOD) obtained at 1.21 × 10-16 M. The DNA biosensor gave reproducible optical response with a satisfactory relative standard deviation (RSD) at 3.1%, (n = 3), and the reflectance response was stable even after four regeneration cycles of the DNA biosensor. The optical genosensor was proven comparable with standard reverse transcription polymerase chain reaction (RT-PCR) in detecting DEN-2 genome acquired from clinical samples of serum, urine and saliva of dengue virus infected patients under informed consent. The developed reflectometric DNA biosensor is advantageous in offering an early DEN-2 diagnosis, when fever symptom started to manifest in patient.
    Matched MeSH terms: Dengue Virus/isolation & purification*
  9. Johari NA, Voon K, Toh SY, Sulaiman LH, Yap IKS, Lim PKC
    PLoS Negl Trop Dis, 2019 Nov;13(11):e0007889.
    PMID: 31730672 DOI: 10.1371/journal.pntd.0007889
    Dengue fever is endemic in Malaysia, contributing to significant economic and health burden in the country. Aedes aegypti and Ae. albopictus are the main vectors of the dengue virus (DENV), which circulates in sylvatic and human transmission cycles and has been present in Malaysia for decades. The study investigated the presence and distribution of DENV in urban localities in the Klang Valley, Peninsular Malaysia. A total of 364 Ae. aegypti and 1,025 Ae. albopictus larvae, and 10 Ae. aegypti and 42 Ae. albopictus adult mosquitoes were screened for the presence of DENV. In total, 31 (2.2%) samples were positive, of which 2 Ae. albopictus larvae were co-infected with two serotypes, one with DENV-2 and DENV-3 and the other with DENV-3 and DENV-4. Phylogenetic analysis determined that the isolates belonged to DENV-1 genotype I (1 Ae. aegypti adult), DENV-2 (1 Ae. albopictus larva), DENV-3 genotype V (3 Ae. aegypti larvae and 10 Ae. albopictus larvae) and DENV-4 genotype IV (6 Ae. aegypti larvae and 12 Ae. albopictus larvae), a sylvatic strain of DENV-4 which was most closely related with sylvatic strains isolated from arboreal mosquitoes and sentinel monkeys in Peninsular Malaysia in the 1970s. All four DENV serotypes were co-circulating throughout the study period. The detection of a sylvatic strain of DENV-4 in Ae. aegypti and Ae. albopictus mosquitoes in urban areas in Peninsular Malaysia highlights the susceptibility of these vectors to infection with sylvatic DENV. The infectivity and vector competence of these urban mosquitoes to this strain of the virus needs further investigation, as well as the possibility of the emergence of sylvatic virus into the human transmission cycle.
    Matched MeSH terms: Dengue Virus/isolation & purification*
  10. Teoh BT, Sam SS, Tan KK, Johari J, Danlami MB, Hooi PS, et al.
    BMC Infect Dis, 2013;13:387.
    PMID: 23964963 DOI: 10.1186/1471-2334-13-387
    BACKGROUND: Early and rapid detection of dengue virus (DENV) infection during the febrile period is crucial for proper patient management and prevention of disease spread. An easy to perform and highly sensitive method is needed for routine implementation especially in the resource-limited rural healthcare settings where dengue is endemic.
    METHODS: A single-tube reverse transcription-loop-mediated isothermal amplification (RT-LAMP) assay with a set of nine primers was developed for the detection of all four DENV serotypes and their different genotypes. The sensitivity and specificity of the RT-LAMP were evaluated. The clinical applicability of RT-LAMP assay for detection of DENV RNA was assessed in a total of 305 sera of clinically-suspected dengue patients. The test results of RT-LAMP were statistically compared to those of quantitative reverse transcription-polymerase chain reaction (qRT-PCR), IgM- and IgG-capture enzyme-linked immunosorbent assays (ELISA).
    RESULTS: Acute DENV infection was confirmed in 171 samples (n = 305); 43.3% (74/171) and 46.8% (80/171) of the samples were positive for DENV using RT-LAMP and qRT-PCR, respectively. The combination of RT-LAMP with the dengue IgM and IgG ELISA increased detection of acute DENV infection to 97.7% (167/171), in comparison to only 70.8% (121/171) when dengue IgM and IgG ELISA alone were used. The RT-LAMP assays showed high concordance (κ = 0.939) with the qRT-PCR. The RT-LAMP assay detected up to 10 copies of virus RNA within an hour but 100% reproducibility (12/12) was achieved with 100 copies. There was no cross reactivity of RT-LAMP with other closely related arboviruses.
    CONCLUSION: The RT-LAMP assay developed in this study is sensitive, specific and simple to perform. The assay improved the detection of dengue when used in combination with serological methods.
    Matched MeSH terms: Dengue Virus/isolation & purification*
  11. Sjatha F, Takizawa Y, Yamanaka A, Konishi E
    Infect Genet Evol, 2012 Dec;12(8):1938-43.
    PMID: 22959957 DOI: 10.1016/j.meegid.2012.08.006
    Dengue viruses are mosquito-borne viruses that cause dengue fever and dengue hemorrhagic fever, both of which are globally important diseases. These viruses have evolved in a transmission cycle between human hosts and mosquito vectors in various tropical and subtropical environments. We previously isolated three strains of dengue type 1 virus (DENV1) and 14 strains of dengue type 3 virus (DENV3) during an outbreak of dengue fever and dengue hemorrhagic fever in Jakarta, Indonesia in 1988. Here, we compared the nucleotide sequences of the entire envelope protein-coding region among these strains. The isolates were 97.6-100% identical for DENV1 and 98.8-100% identical for DENV3. All DENV1 isolates were included in two different clades of genotype IV and all DENV3 isolates were included in a single clade of genotype I. For DENV1, three Yap Island strains isolated in 2004 were the only strains closely related to the present isolates; the recently circulated Indonesian strains were in different clades. Molecular clock analyses estimated that ancestors of the genotype IV strains of DENV1 have been indigenous in Indonesia since 1948. We predict that they diverged frequently around 1967 and that their offspring distributed to Southeast Asia, the Western Pacific, and Africa. For DENV3, the clade containing all the present isolates also contained strains isolated from other Indonesian regions and other countries including Malaysia, Singapore, China, and East Timor from 1985-2010. Molecular clock analyses estimated that the common ancestor of the genotype I strains of DENV3 emerged in Indonesia around 1967 and diverged frequently until 1980, and that their offspring distributed mainly in Southeast Asia. The first dengue outbreak in 1968 and subsequent outbreaks in Indonesia might have influenced the divergence and distribution of the DENV1 genotype IV strains and the DENV3 genotype I strains in many countries.
    Matched MeSH terms: Dengue Virus/isolation & purification
  12. Vinomarlini G, Rogayah T, Saraswathy TS, Thayan R, Apandi M, Fauziah MK, et al.
    PMID: 21323170
    From 2005 to 2009, the Institute for Medical Research (IMR), Kuala Lumpur, Malaysia received 488 serum and blood samples from hospitalized patients on the East Coast of Peninsular Malaysia, suspected of having dengue infection. In this study we determined the prevailing dengue serotypes using a real time polymerase chain reaction assay (RT-PCR). All 4 dengue virus serotypes were found circulating during the study period; however the predominant serotype varied. In 2005 and 2006, the predominant serotypes circulating were DENV-1 and DENV-3, in 2007, DENV-1 and DENV-2 were predominant, and in 2008 and 2009, DENV-3 was the predominant serotype.
    Matched MeSH terms: Dengue Virus/isolation & purification
  13. Matlani M, Chakravarti A, Rawal A, Kashyap B, Gurtoo A
    Trop Doct, 2009 Apr;39(2):115-6.
    PMID: 19299303 DOI: 10.1258/td.2008.080257
    As well as dengue fever (DF) and dengue haemorrhagic fever-dengue shock syndrome (DHF/DSS), other atypical manifestations of dengue virus infection have also been reported. The frequency of CNS involvement in dengue remains unknown, although isolated cases with neurological manifestations have been reported in Southeast Asia, Malaysia, Burma, Puerto Rico and India. We present two cases of encephalitis associated with DF and DHF from New Delhi, India.
    Matched MeSH terms: Dengue Virus/isolation & purification*
  14. Yang F, He JF, Xian HX, Zhang HL, He YQ, Yang H, et al.
    Zhonghua Yu Fang Yi Xue Za Zhi, 2009 Sep;43(9):798-802.
    PMID: 20137564
    To isolate and identify the pathogen of Dengue fever from Shenzhen city in 2005 - 2006, and to analyze the molecular characteristics of the isolated Dengue virus strain as well as to explore its possible origin.
    Matched MeSH terms: Dengue Virus/isolation & purification*
  15. Rohani A, Potiwat R, Zamree I, Lee HL
    PMID: 19842428
    In this study, artificial membrane feeding technique was used to orally feed Aedes aegypti with dengue and chikungunya viruses. Virus detection was carried out by reverse transcriptase polymerase chain reaction. The study did not detect dual infection of Ae. aegypti with dengue and chikungunya virus from the same pool or from individual mosquitoes. Oral receptivity of Ae. aegypti to chikungunya virus was higher than that of dengue virus.
    Matched MeSH terms: Dengue Virus/isolation & purification*
  16. Mallhi TH, Sarriff A, Adnan AS, Khan YH, Hamzah AA, Jummaat F, et al.
    J Coll Physicians Surg Pak, 2015 Nov;25(11):828-34.
    PMID: 26577971 DOI: 11.2015/JCPSP.828834
    Dengue Viral Infection (DVI) imperils an estimated 2.5 billion people living in tropical and subtropical regions. World Health Organization (2011) guidelines also classified dengue as 'Expanded Dengue Syndrome' to incorporate wide spectrum of unusual manifestations of dengue infection affecting various organ systems - including liver, kidney, heart and brain. Renal involvements are least appreciated area of dengue infection, therefore, we systematically reviewed studies describing renal disorders in dengue infection, with emphasis on Acute Kidney Injury (AKI). The purpose of current review is to underscore clinicians’attention to this neglected intricacy of DVI. It suggests that dengue induced renal involvements vary from glomerulonephritis, nephrotic range proteinuria and AKI. We observed great disparity in incidence of AKI among dengue patients, based upon criteria used to define AKI. AKI among dengue patients was found to be associated with significant morbidity, mortality and longer hospitalization, adding financial burden to patients and healthcare system. Additionally, we identified several predictors of AKI in dengue patients including old age, obesity, severe dengue infection and concurrent bacterial or viral infection. Direct viral injury and deposition of antigen-antibody complex in glomerulus were found to be possible causes of renal disorders in dengue infection. Prior knowledge of clinico-laboratory characteristics and risk factors with early detection of AKI by using appropriate criteria would not only reduce morbidity and mortality but also decrease burden to patients and healthcare system.
    Matched MeSH terms: Dengue Virus/isolation & purification
  17. Kotaki T, Yamanaka A, Mulyatno KC, Churrotin S, Sucipto TH, Labiqah A, et al.
    Infect Genet Evol, 2016 Jan;37:88-93.
    PMID: 26553170 DOI: 10.1016/j.meegid.2015.11.002
    Indonesia is one of the biggest dengue endemic countries, and, thus, is an important place to investigate the evolution of dengue virus (DENV). We have continuously isolated DENV in Surabaya, the second biggest city in Indonesia, since 2008. We previously reported sequential changes in the predominant serotype from DENV type 2 (DENV-2) to DENV type 1 (DENV-1) in November 2008 and from DENV-1 to DENV-2 in July 2013. The predominance of DENV-2 continued in 2014, but not in 2015. We herein phylogenetically investigated DENV-2 transitions in Surabaya between 2008 and 2014 to analyze the divergence and evolution of DENV-2 concomitant with serotype shifts. All DENV-2 isolated in Surabaya were classified into the Cosmopolitan genotype, and further divided into 6 clusters. Clusters 1-3, dominated by Surabaya strains, were defined as the "Surabaya lineage". Clusters 4-6, dominated by strains from Singapore, Malaysia, and many parts of Indonesia, were the "South East Asian lineage". The most recent common ancestor of these strains existed in 1988, coinciding with the time that an Indonesian dengue outbreak took place. Cluster 1 appeared to be unique because no other DENV-2 isolate was included in this cluster. The predominance of DENV-2 in 2008 and 2013-14 were caused by cluster 1, whereas clusters 2 and 3 sporadically emerged in 2011 and 2012. The characteristic amino acids of cluster 1, E-170V and E-282Y, may be responsible for its prevalence in Surabaya. No amino acid difference was observed in the envelope region between strains in 2008 and 2013-14, suggesting that the re-emergence of DENV-2 in Surabaya was due to the loss or decrease of herd immunity in the 5-year period when DENV-2 subsided. The South East Asian lineage primarily emerged in Surabaya in 2014, probably imported from other parts of Indonesia or foreign countries.
    Matched MeSH terms: Dengue Virus/isolation & purification
  18. Jahanshahi P, Sekaran SD, Adikan FR
    Med Biol Eng Comput, 2015 Aug;53(8):679-87.
    PMID: 25791696 DOI: 10.1007/s11517-015-1262-2
    Evaluation of binding between analytes and its relevant ligands on surface plasmon resonance (SPR) biosensor is of considerable importance for accurate determination and screening of an interference in immunosensors. Dengue virus serotype 2 was used as a case study in this investigation. This research work compares and interprets the results obtained from analytical analysis with the experimental ones. Both the theoretical calculations and experimental results are verified with one sample from each category of dengue serotypes 2 (low, mid, and high positive), which have been examined in the database of established laboratorial diagnosis. In order to perform this investigation, the SPR angle variations are calculated, analyzed, and then validated via experimental SPR angle variations. Accordingly, the error ratios of 5.35, 6.54, and 3.72% were obtained for the low-, mid-, and high-positive-specific immune globulins of patient serums, respectively. In addition, the magnetic fields of the biosensor are numerically simulated to show the effect of different binding mediums.
    Matched MeSH terms: Dengue Virus/isolation & purification*
  19. Chan SY, Kautner I, Lam SK
    PMID: 7855637
    Dengue viruses pose a considerable global public health problem with an estimated 100 million cases of illness every year. This illustrates the need for rapid and reliable diagnostic methods for proper patient management and disease control. Currently, laboratory diagnosis depends on serology or virus isolation, with both methods having certain drawbacks. Alternatively, reverse transcription and polymerase chain reaction (RT-PCR) offers the potential for the rapid, highly sensitive and specific detection of dengue viruses. Since we occasionally encounter the problem of insufficient amounts of patient serum for the direct detection of dengue viruses, a method was developed for the extraction of viral RNA after biological amplification in mosquito larvae. Using this method, 15 of 19 clinical samples tested were correctly identified using RT-PCR.
    Matched MeSH terms: Dengue Virus/isolation & purification*
  20. Fang R, Sinniah M, Kuen LS
    Malays J Pathol, 1992 Dec;14(2):117-20.
    PMID: 1304624
    Dengue fever/Dengue haemorrhagic fever (DF/DHF) has been a public health problem in Malaysia with an endemic level of about 7 per 100,000 population per year. In 1990, Malaysia experienced its most severe outbreak of DF/DHF with a record total of 5,590 cases referred to the Division of Virology, Institute for Medical Research (IMR). Of these, 1,880 were confirmed serologically to be DF/DHF. The conventional serological procedure, the Haemagglutination Inhibition (HI) test, for the diagnosis of DF/DHF is cumbersome and causes delay in diagnosis. Another problem associated with the HI test has been that it has often been difficult to obtain a second convalescent serum sample for an accurate diagnosis. This has raised an urgent need to establish a "rapid" test for diagnosis of DF/DHF. As such the authors recently carried out an evaluation of a newly available commercial rapid test, namely, the Dengue Blot Assay (Diagnostic Biotechnology Singapore Pte Ltd). The test is intended for use in laboratory confirmation of dengue virus infection. The evaluation was to determine if the test could be utilised as a routine laboratory test and to establish its sensitivity and specificity. Over 400 samples were tested against the Dengue Blot Assay. Results were checked against an in-house Dengue IgM ELISA and HI assay. Preliminary results indicate that the sensitivity and specificity of the Dengue Blot is satisfactory. Our results also indicate that the Dengue Blot has a useful role to play in a routine laboratory especially since it provides rapid results on single serum samples thereby reducing the workload in a busy diagnostic laboratory.
    Matched MeSH terms: Dengue Virus/isolation & purification*
Filters
Contact Us

Please provide feedback to Administrator ([email protected])