Displaying publications 1 - 20 of 196 in total

Abstract:
Sort:
  1. Norella Kong CT, Chin JH, Izham Cheong IK, Abu Bakar A
    Med J Malaysia, 1988 Jun;43(2):134-7.
    PMID: 3237129
    Matched MeSH terms: Creatinine/urine*
  2. Singh GK, Balzer BW, Desai R, Jimenez M, Steinbeck KS, Handelsman DJ
    Ann. Clin. Biochem., 2015 Nov;52(Pt 6):665-71.
    PMID: 25780247 DOI: 10.1177/0004563215580385
    Urinary hormone concentrations are often adjusted to correct for hydration status. We aimed to determine whether first morning void urine hormones in growing adolescents require adjustments and, if so, whether urinary creatinine or specific gravity are better adjustments.
    Matched MeSH terms: Creatinine
  3. Azrina Md Ralib, Farah Nadia Mohd Hanafiah, Fatimah Dzaharudin, Muhammad Rasydan Abd Ghani, Mohd Nizamudin Ismail, Mohd Basri Mat Nor
    MyJurnal
    Kinetic estimate of GFR (keGFR) is a more accurate estimate of GFR in the
    acute settings with rapidly changing kidney functions. It takes into account the changes
    of creatinine over time, creatinine production rate, and the volume of distribution,
    however needs serial measurement of creatinine. We evaluated which methods of the
    conventional eGFR measurement best correlates with keGFR. This could assist clinicians
    in using a simpler method of calculation and is useful in the absence of serial plasma
    creatinine. (Copied from article).
    Matched MeSH terms: Creatinine
  4. Liao C, Liu F, Alomirah H, Loi VD, Mohd MA, Moon HB, et al.
    Environ Sci Technol, 2012 Jun 19;46(12):6860-6.
    PMID: 22620267 DOI: 10.1021/es301334j
    As concern regarding the toxic effects of bisphenol A (BPA) grows, BPA in many consumer products is gradually being replaced with compounds such as bisphenol S (BPS). Nevertheless, data on the occurrence of BPS in human specimens are limited. In this study, 315 urine samples, collected from the general populations in the United States, China, India, Japan, Korea, Kuwait, Malaysia, and Vietnam, were analyzed for the presence of total BPS (free plus conjugated) concentrations by high-performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS). BPS was detected in 81% of the urine samples analyzed at concentrations ranging from below the limit of quantitation (LOQ; 0.02 ng/mL) to 21 ng/mL (geometric mean: 0.168 ng/mL). The urinary BPS concentration varied among countries, and the highest geometric mean concentration [1.18 ng/mLor 0.933 μg/g creatinine (Cre)] of BPS was found in urine samples from Japan, followed by the United States (0.299 ng/mL, 0.304 μg/g Cre), China (0.226 ng/mL, 0.223 μg/g Cre), Kuwait (0.172 ng/mL, 0.126 μg/g Cre), and Vietnam (0.160 ng/mL, 0.148 μg/g Cre). Median concentrations of BPS in urine samples from the Asian countries were 1 order of magnitude lower than the median concentrations reported earlier for BPA in the same set of samples, with the exception of samples from Japan. There were no significant differences in BPS concentrations between genders (male versus female), or among age groups (categorized as ≤ 19, 20-29, 30-39, 40-49, and ≥ 50 years), or races (Caucasian versus Asian). The daily intake (EDI) of BPS was estimated on the basis of urinary concentrations using a simple pharmacokinetic approach. The median EDI values of BPS in Japan, China, United States, Kuwait, Vietnam, Malaysia, India, and Korea were 1.67, 0.339, 0.316, 0.292, 0.217, 0.122, 0.084, and 0.023 μg/person, respectively. This is the first study to report the occurrence of BPS in human urine.
    Matched MeSH terms: Creatinine/urine
  5. Ang QY, Low SC
    Anal Bioanal Chem, 2015 Sep;407(22):6747-58.
    PMID: 26163132 DOI: 10.1007/s00216-015-8841-9
    Molecular imprinting is an emerging technique to create imprinted polymers that can be applied in affinity-based separation, in particular, biomimetic sensors. In this study, the matrix of siloxane bonds prepared from the polycondensation of hydrolyzed tetraethoxysilane (TEOS) was employed as the inorganic monomer for the formation of a creatinine (Cre)-based molecularly imprinted polymer (MIP). Doped aluminium ion (Al(3+)) was used as the functional cross-linker that generated Lewis acid sites in the confined silica matrix to interact with Cre via sharing of lone pair electrons. Surface morphologies and pore characteristics of the synthesized MIP were determined by field emission scanning electron microscopy (FESEM) and Brunauer-Emmet-Teller (BET) analyses, respectively. The imprinting efficiency of MIPs was then evaluated through the adsorption of Cre with regard to molar ratios of Al(3+). A Cre adsorption capacity of up to 17.40 mg Cre g(-1) MIP was obtained and adsorption selectivity of Cre to its analogues creatine (Cr) and N-hydroxysuccinimide (N-hyd) were found to be 3.90 ± 0.61 and 4.17 ± 3.09, respectively. Of all the studied MIP systems, chemisorption was predicted as the rate-limiting step in the binding of Cre. The pseudo-second-order chemical reaction kinetic provides the best correlation of the experimental data. Furthermore, the equilibrium adsorption capacity of MIP fit well with a Freundlich isotherm (R (2) = 0.98) in which the heterogeneous surface was defined.
    Matched MeSH terms: Creatinine/chemistry*
  6. Keshavarzi F
    Int J Clin Pharm, 2015 Oct;37(5):675-7.
    PMID: 26173939 DOI: 10.1007/s11096-015-0157-5
    Creatinine clearance estimation is widely used to evaluate the renal function of the patients in order to initiate or adjust the drugs dosage. However serum creatinine, as a muscle metabolism by-product, may not be a reliable parameter in underweight and/or non-ambulatory patients, such as geriatric, acquired immunodeficiency syndrome patients and bed-confined and cachexic cases. To avoid overestimation of the renal function in those patients, serum cystatin C can be considered as a sensitive and accurate alternative for serum creatinine.
    Matched MeSH terms: Creatinine/blood*
  7. Chua CT, Wang F
    Med J Malaysia, 1983 Sep;38(3):244-50.
    PMID: 6672569
    Study site: CAPD, University Malaya Medical Centre (UMMC), Kuala Lumpur, Malaysia
    Matched MeSH terms: Creatinine/blood
  8. Zainol Abidin MN, Goh PS, Said N, Ismail AF, Othman MHD, Hasbullah H, et al.
    ACS Appl Mater Interfaces, 2020 Jul 22;12(29):33276-33287.
    PMID: 32589391 DOI: 10.1021/acsami.0c08947
    The development of wearable artificial kidney demands an efficient dialysate recovery, which relies upon the adsorption process. This study proposes a solution to solve the problem of competitive adsorption between the uremic toxins by employing two adsorptive components in a membrane separation process. Dual-layer hollow fiber (DLHF) membranes, which are composed of a polysulfone (PSf)/activated carbon (AC) inner layer and a PSf/poly(methyl methacrylate) (PMMA) outer layer, were prepared for co-adsorptive removal of creatinine and urea from aqueous solution. The DLHF membranes were characterized in terms of morphological, physicochemical, water transport, and creatinine adsorption properties. The membrane was then subjected to an ultrafiltration adsorption study for performance evaluation. The incorporation of AC in membrane, as confirmed by microscopic and surface analyses, has improved the pure water flux up to 25.2 L/(m2 h). A membrane with optimum AC loading (9 wt %) demonstrated the highest maximum creatinine adsorption capacity (86.2 mg/g) based on the Langmuir adsorption isotherm model. In the ultrafiltration adsorption experiment, the membrane removed creatinine and urea with a combined average percent removal of 29.3%. Moreover, the membrane exhibited creatinine and urea uptake recoveries of 98.8 and 81.2%, respectively. The combined action of PMMA and AC in the PSf DLHF membrane has made the adsorption of multiple uremic toxins possible during dialysate recovery.
    Matched MeSH terms: Creatinine/chemistry*
  9. Mohd Tahir NA, Mohd Saffian S, Islahudin FH, Abdul Gafor AH, Makmor-Bakry M
    J Korean Med Sci, 2020 Sep 21;35(37):e306.
    PMID: 32959542 DOI: 10.3346/jkms.2020.35.e306
    BACKGROUND: The objective of this study was to compare the performance of cystatin C- and creatinine-based estimated glomerular filtration rate (eGFR) equations in predicting the clearance of vancomycin.

    METHODS: MEDLINE and Embase databases were searched from inception up to September 2019 to identify all studies that compared the predictive performance of cystatin C- and/or creatinine-based eGFR in predicting the clearance of vancomycin. The prediction errors (PEs) (the value of eGFR equations minus vancomycin clearance) were quantified for each equation and were pooled using a random-effects model. The root mean squared errors were also quantified to provide a metric for imprecision.

    RESULTS: This meta-analysis included evaluations of seven different cystatin C- and creatinine-based eGFR equations in total from 26 studies and 1,234 patients. The mean PE (MPE) for cystatin C-based eGFR was 4.378 mL min-1 (95% confidence interval [CI], -29.425, 38.181), while the creatinine-based eGFR provided an MPE of 27.617 mL min-1 (95% CI, 8.675, 46.560) in predicting clearance of vancomycin. This indicates the presence of unbiased results in vancomycin clearance prediction by the cystatin C-based eGFR equations. Meanwhile, creatinine-based eGFR equations demonstrated a statistically significant positive bias in vancomycin clearance prediction.

    CONCLUSION: Cystatin C-based eGFR equations are better than creatinine-based eGFR equations in predicting the clearance of vancomycin. This suggests that utilising cystatin C-based eGFR equations could result in better accuracy and precision to predict vancomycin pharmacokinetic parameters.

    Matched MeSH terms: Creatinine/blood*
  10. Chan WF, Lim MK, Aun LM
    Med J Malaysia, 1974 Sep;29(1):54-6.
    PMID: 4282631
    Matched MeSH terms: Creatinine/analysis*
  11. Jalalonmuhali M, Kok Peng N, Soo Kun L
    Int J Nephrol, 2017;2017:2901581.
    PMID: 28702264 DOI: 10.1155/2017/2901581
    AIM: To validate the accuracy of estimated glomerular filtration rate (eGFR) equations in Malay population attending our hospital in comparison with radiolabeled measured GFR.
    METHODS: A cross-sectional study recruiting volunteered patients in the outpatient setting. Chromium EDTA (51Cr-EDTA) was used as measured GFR. The predictive capabilities of Cockcroft-Gault equation corrected for body surface area (CGBSA), four-variable Modification of Diet in Renal Disease (4-MDRD), and Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) equations were calculated.
    RESULTS: A total of 51 subjects were recruited with mean measured GFR 42.04 (17.70-111.10) ml/min/1.73 m(2). Estimated GFR based on CGBSA, 4-MDRD, and CKD-EPI were 40.47 (16.52-115.52), 35.90 (14.00-98.00), and 37.24 (14.00-121.00), respectively. Higher accuracy was noted in 4-MDRD equations throughout all GFR groups except for subgroup of GFR ≥ 60 ml/min/1.73 m(2) where CGBSA was better.
    CONCLUSIONS: The 4-MDRD equation seems to perform better in estimating GFR in Malay CKD patients generally and specifically in the subgroup of GFR < 60 ml/min/1.73 m(2) and both BMI subgroups.
    Study site: University Malaya Medical Centre (UMMC), Kuala Lumpur, Malaysia
    Matched MeSH terms: Creatinine*
  12. The EMPA-KIDNEY Collaborative Group, Herrington WG, Staplin N, Wanner C, Green JB, Hauske SJ, et al.
    N Engl J Med, 2023 Jan 12;388(2):117-127.
    PMID: 36331190 DOI: 10.1056/NEJMoa2204233
    BACKGROUND: The effects of empagliflozin in patients with chronic kidney disease who are at risk for disease progression are not well understood. The EMPA-KIDNEY trial was designed to assess the effects of treatment with empagliflozin in a broad range of such patients.

    METHODS: We enrolled patients with chronic kidney disease who had an estimated glomerular filtration rate (eGFR) of at least 20 but less than 45 ml per minute per 1.73 m2 of body-surface area, or who had an eGFR of at least 45 but less than 90 ml per minute per 1.73 m2 with a urinary albumin-to-creatinine ratio (with albumin measured in milligrams and creatinine measured in grams) of at least 200. Patients were randomly assigned to receive empagliflozin (10 mg once daily) or matching placebo. The primary outcome was a composite of progression of kidney disease (defined as end-stage kidney disease, a sustained decrease in eGFR to <10 ml per minute per 1.73 m2, a sustained decrease in eGFR of ≥40% from baseline, or death from renal causes) or death from cardiovascular causes.

    RESULTS: A total of 6609 patients underwent randomization. During a median of 2.0 years of follow-up, progression of kidney disease or death from cardiovascular causes occurred in 432 of 3304 patients (13.1%) in the empagliflozin group and in 558 of 3305 patients (16.9%) in the placebo group (hazard ratio, 0.72; 95% confidence interval [CI], 0.64 to 0.82; P<0.001). Results were consistent among patients with or without diabetes and across subgroups defined according to eGFR ranges. The rate of hospitalization from any cause was lower in the empagliflozin group than in the placebo group (hazard ratio, 0.86; 95% CI, 0.78 to 0.95; P = 0.003), but there were no significant between-group differences with respect to the composite outcome of hospitalization for heart failure or death from cardiovascular causes (which occurred in 4.0% in the empagliflozin group and 4.6% in the placebo group) or death from any cause (in 4.5% and 5.1%, respectively). The rates of serious adverse events were similar in the two groups.

    CONCLUSIONS: Among a wide range of patients with chronic kidney disease who were at risk for disease progression, empagliflozin therapy led to a lower risk of progression of kidney disease or death from cardiovascular causes than placebo. (Funded by Boehringer Ingelheim and others; EMPA-KIDNEY ClinicalTrials.gov number, NCT03594110; EudraCT number, 2017-002971-24.).

    Matched MeSH terms: Creatinine/urine
  13. Zulkarnain M, Wan Zain WMS, Najib MY, Aniza MJ
    Med J Malaysia, 2024 Jul;79(4):457-463.
    PMID: 39086344
    INTRODUCTION: Hyperuricaemia is common in essential hypertension with varying results in different populations. This study sought to ascertain the association between serum uric acid levels and essential hypertension in Hospital Universiti Sains Malaysia (HUSM).

    MATERIALS AND METHODS: A case-control study design involving 132 subjects (88 subjects of hypertension patients for case group and 44 subjects for control group) aged 18 to 40 years old of both genders was conducted at HUSM primary care clinic and physician clinic from May 2020 to May 2021. Blood samples were collected from each of the case and control subjects and analysed for serum uric acid, urea, creatinine, total cholesterol, triglycerides, LDL and HDL on chemical analyser Architect c8000. The data were analysed by using SPSS Statistics 26.0 version.

    RESULTS: The proportion of subjects with hyperuricaemia in the case group was 48.9%. A significant difference in the uric acid levels between the case group (390.64±92.65μmol/L) and control group (352.09±86.07μmol/L), (p<0.05) was observed. There was no significant difference in the serum uric acid mean ± SD based on the duration of hypertension (<5 years and ≥5 years), (p=0.331) and stages of hypertension (p>0.05). In case group, significant correlations were established between uric acid and triglycerides (r=0.255, p<0.05), uric acid and HDL (r= -0.223, p<0.05), uric acid and urea (r=0.299, p<0.05), uric acid and creatinine (r=0.486, p<0.01). No correlation among uric acid and total cholesterol levels (p>0.05), uric acid and LDL (p>0.05). Serum uric acid was a vital variable in developing hypertension (p<0.05) but not when adapted for age and body mass index (BMI) (p>0.05).

    CONCLUSION: Serum uric acid was significantly elevated in essential hypertension. The significant associations were established between uric acid and triglycerides, HDL, urea and creatinine in essential hypertension. Serum uric acid was a vital variable to develop hypertension, but the association was weakened by other co-founders as age and BMI. A large-scale population-based study is required to truly conclude the association between serum uric acid levels and essential hypertension in our population.

    Matched MeSH terms: Creatinine/blood
  14. Loo CS, Zaki M, Sulaiman AB, Sukanya AB, Voon YC, Kua SL
    Med J Malaysia, 1994 Mar;49(1):36-43.
    PMID: 8057988
    Functional renal reserve is a measure of the capacity of the kidney to increase the glomerular filtration in response to the stimulus of a protein meal or amino acid infusion. The aim of this study was to evaluate the usefulness of protein meal test to measure functional renal reserve in normal subjects and various groups of renal patients. One hundred and twenty five subjects from the Nephrology Clinic, Kuala Lumpur General Hospital were subjected to a protein loading test to measure their renal reserve. Each subject had to eat a 100 gram cooked chicken meat and timed 2 hours urine collections before and after the test meal were done to measure the creatinine clearances. The 62 healthy subjects showed a mean renal reserve (creatinine clearance after protein loading-baseline creatinine clearance) of 31.0 ml/min. The 31 subjects with various kidney diseases showed a mean renal reserve of 13.5 ml/min. The 19 renal transplant recipients showed renal reserve of 13.2 ml/min. The 12 nephrectomised donors showed renal reserve of 5.4ml/min. Renal reserve may be used to assess suitability of living related transplant donor for nephrectomy.

    Study site: Nephrology Clinic, Kuala Lumpur General Hospital
    Matched MeSH terms: Creatinine/metabolism; Creatinine/urine*
  15. Jacqz-Aigrain E, Leroux S, Thomson AH, Allegaert K, Capparelli EV, Biran V, et al.
    J Antimicrob Chemother, 2019 08 01;74(8):2128-2138.
    PMID: 31049551 DOI: 10.1093/jac/dkz158
    OBJECTIVES: In the absence of consensus, the present meta-analysis was performed to determine an optimal dosing regimen of vancomycin for neonates.

    METHODS: A 'meta-model' with 4894 concentrations from 1631 neonates was built using NONMEM, and Monte Carlo simulations were performed to design an optimal intermittent infusion, aiming to reach a target AUC0-24 of 400 mg·h/L at steady-state in at least 80% of neonates.

    RESULTS: A two-compartment model best fitted the data. Current weight, postmenstrual age (PMA) and serum creatinine were the significant covariates for CL. After model validation, simulations showed that a loading dose (25 mg/kg) and a maintenance dose (15 mg/kg q12h if <35 weeks PMA and 15 mg/kg q8h if ≥35 weeks PMA) achieved the AUC0-24 target earlier than a standard 'Blue Book' dosage regimen in >89% of the treated patients.

    CONCLUSIONS: The results of a population meta-analysis of vancomycin data have been used to develop a new dosing regimen for neonatal use and to assist in the design of the model-based, multinational European trial, NeoVanc.

    Matched MeSH terms: Creatinine
  16. Shamsul, B.S., Zakirah, M.
    MyJurnal
    The main objective of this study is to determine the association between respirable hexavalent chromium compounds with urinary β2-microglobulin levels among welders in an automotive components manufacturing plant. 49 welders and 39 workers involved in stamping process were selected as the exposed and the comparative group. β2-microglobulin is a protein renal tubular dysfunction marker that can indicate renal dysfunction caused by heavy metal. Air samples of worker’s breathing zone were collected using personal air sampling pump and filter papers. Filter papers were then diluted and analysed with Atomic Absorption Spectrophotometry (AAS). Workers’ urine samples were collected at the end of 8-hour work shift and analysed with β2-microglobulin ELISA Kit (IBL-Hamburg) and a microtiter reader. Meanwhile, creatinine levels were analysed with creatinine test strips and Reflotron®. A mean concentration of respirable hexavalent chromium compounds in air for the exposed group was 0.135 ± 0.043μg/m3 while for the non-exposed group was 0.124 ± 0.029μg/m3. The mean level of urinary β2-microglobulin per creatinine for the exposed group was 84.996 ± 39.246μg/g while that of the comparative group was 61.365 ± 21.609μg/g. The concentrations of respirable hexavalent chromium compounds were higher in the exposed group compared to the comparative group (Z=-2.444, p=0.015). β2-microglobulin level was also higher in the exposed group compared to the non-exposed group (t=3.821, p=
    Matched MeSH terms: Creatinine
  17. Hussain Imam Muhammad Ismail, Azizi Omar
    MyJurnal
    Familial Paroxysmal Rhabdomyolysis of the non-exertional variety is a rare but treatable disorder previously not described in Malaysia. We report 3 Malay siblings of a consanguinous marriage who developed myoglobulinuria during a febrile illness. The first 2 died without being investigated, but the last had creatinine kinase levels of 24,800 UIL suggesting acute rhabdomyolysis. Fasting appears to be a major precipitating factor, and glucose infusions combined with alkaline diuresis may be life-saving.
    Matched MeSH terms: Creatinine
  18. Mohd Norhafsam Maghpor, Suhaily Amran, Ahmad Sayuti Zainal Abidin, Naemah Tajol Arus, Nurzuhairah Jamil, Nor Husna Mat Hussin
    MyJurnal
    A study has been conducted on trans,trans-muconic acid (t,t-MA) as the biomarker for benzene exposure among
    oil and gas petrol tanker drivers. The objectives of this study are to determine the significant difference and the
    correlation between Benzene personal exposure and urinary t,t-MA among exposed and non-exposed workers. A total
    of 92 questionnaires were distributed to obtain demographic and descriptive data. Benzene personal exposure was
    sampled using SKC passive samplers and the data was analyzed using GC-FID. Urinary t,t-MA was collected at end of
    work shift and analyzed using HPLC-UV detector. A total of 30 non-exposed workers were also sampled. The averages
    of urinary t,t-MA were 96.65 ug/g creatinine for exposed workers and 0.51 ug/g creatinine for non-exposed workers.
    Meanwhile, the averages of Benzene personal exposure were 0.37 mg/m3 and 0.01 mg/m3 for exposed workers and
    non-exposed workers respectively. No significant correlation was found between exposure to benzene with excreted
    urinary t,t-MA of workers occupationally exposed (p-value > 0.05) as well as to workers non-exposed to benzene
    (p-value > 0.05). In conclusion, there is no significant correlation found between Benzene personal exposure and
    urinary t,t-MA among exposed and non-exposed workers. Applicability of using t,t-MA as the biomarker of benzene
    exposure shall be further discussed with all the other confounding factors to be taken into account.
    Matched MeSH terms: Creatinine
  19. Liao CM, Cheong IKS, Kong NCT
    Family Physician, 1991;3(2):31-33.
    Creatinine clearance is calculated from 24 hour urine creatinine excretion. This method of measuring creatinine clearance is cumbersome. Many formulae have been proposed as an alternative method of obtaining predicted creatinine clearance and they have all shown satisfactory results. From our study using 4 formulae, the correlation coefficient using these formulae rangedfrom 0.71 - 0.75. The correlation clearance was even better at > 0.90. We therefore advocate the routine use of these formulae for predicting creatinine clearance by clinicians.
    Study site: Nephrology clinic, Universiti Kebangsaan Malaysia unit at Hospital Kuala Lumpur, Malaysia
    Matched MeSH terms: Creatinine
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links