Displaying all 7 publications

Abstract:
Sort:
  1. Jalil N, Azma RZ, Mohamed E, Ithnin A, Alauddin H, Baya SN, et al.
    EXCLI J, 2016;15:155-62.
    PMID: 27103895 DOI: 10.17179/excli2015-604
    Glucose-6-Phosphate Dehydrogenase (G6PD) deficiency is the commonest cause of neonatal jaundice in Malaysia. Recently, OSMMR2000-D G6PD Assay Kit has been introduced to quantitate the level of G6PD activity in newborns delivered in Universiti Kebangsaan Malaysia Medical Centre (UKMMC). As duration of sample storage prior to analysis is one of the matters of concern, this study was conducted to identify the stability of G6PD enzyme during storage. A total of 188 cord blood samples from normal term newborns delivered at UKMMC were selected for this study. The cord bloods samples were collected in ethylene-diamine-tetra-acetic acid (EDTA) tubes and refrigerated at 2-8 °C. In addition, 32 out of 188 cord blood samples were spotted on chromatography paper, air-dried and stored at room temperature. G6PD enzyme activities were measured daily for 7 days using the OSMMR2000-D G6PD Assay Kit on both the EDTA blood and dried blood samples. The mean value for G6PD activity was compared between days of analysis using Student Paired T-Test. In this study, 172 out of 188 cord blood samples showed normal enzyme levels while 16 had levels corresponding to severe enzyme deficiency. The daily mean G6PD activity for EDTA blood samples of newborns with normal G6PD activity showed a significant drop on the fourth day of storage (p < 0.005) while for samples with severely deficient G6PD activity, significant drop was seen on third day of storage (p = 0.002). Analysis of dried cord blood showed a significant reduction in enzyme activity as early as the second day of storage (p = 0.001). It was also noted that mean G6PD activity for spotted blood samples were lower compared to those in EDTA tubes for all days (p = 0.001). Thus, EDTA blood samples stored at 2-8 °C appeared to have better stability in terms of their G6PD enzyme level as compared to dried blood samples on filter paper, giving a storage time of up to 3 days.
    Matched MeSH terms: Clinical Enzyme Tests
  2. Azma, R.Z., Siti Zubaidah, M., Azlin, I., Hafiza, A., Nurasyikin, Y., Nor Hidayati, S., et al.
    Medicine & Health, 2014;9(1):11-21.
    MyJurnal
    Glucose-6-phosphate dehydrogenase (G6PD) deficiency is the most common enzyme deficiency worldwide including Malaysia. Screening of cord blood for partial G6PD deficiency is important as they are also prone to develop acute haemolysis. In this study, we determined the prevalence of partial G6PD deficient in paediatric population aged 1 month-12 years and normal term female neonates using OSMMR-D kit with haemoglobin (Hb) normalization and compare it with florescence spot test (FST). A total of 236 children, aged between between 1 month-12 years and 614 normal term female neonates were recruited for this study. Determination of normal means for G6PD activity and; cut-off points for partial and severe deficiency were determined according to WHO Working Group (1989). Determination of prevalence for partial deficiency for both groups (female patient) was done using this enzyme assay kit and findings were compared with FST. In this study, 15.7% (18/115) female children were classified as partial G6PD deficient by quantitative enzyme method (G6PD activity: 4.23-5.26U/gHb). However, FST only detected 0.9% (1/115) with minimal G6PD activity. The prevalence of partial G6PD deficiency in female neonate group was 3.42% (21/614) by enzyme assay versus 0.49% (3/614) by FST. This study concluded that our routine screening method using FST was unable to diagnose female heterozygotes. We recommend using this quantitative enzyme assay method by OSMMR-D kit since it was more sensitive in detecting G6PD deficiency in female neonates compared to FST.
    Matched MeSH terms: Clinical Enzyme Tests
  3. Fah NT
    Med J Malaysia, 1977 Jun;31(4):309-15.
    PMID: 927238
    Matched MeSH terms: Clinical Enzyme Tests
  4. Chan WK, Ida NH, Cheah PL, Goh KL
    J Dig Dis, 2014 Oct;15(10):545-52.
    PMID: 25060399 DOI: 10.1111/1751-2980.12175
    To perform a follow-up study on non-alcoholic fatty liver disease (NAFLD) patients in our previous study using paired liver biopsy.
    Matched MeSH terms: Clinical Enzyme Tests/methods
  5. Gupta ED, Sakthiswary R
    Asian Cardiovasc Thorac Ann, 2014 May;22(4):397-401.
    PMID: 24771726 DOI: 10.1177/0218492313484917
    The objectives of this study were to determine the incidence of a myocardial infarction "false alarm" and evaluate the efficacy of the initial electrocardiogram and cardiac enzymes in diagnosing myocardial infarction in Malaysia.
    Matched MeSH terms: Clinical Enzyme Tests*
  6. Kamath S, Lopez CG
    Med J Aust, 1973 Nov 3;2(18):867-8.
    PMID: 4782397
    Matched MeSH terms: Clinical Enzyme Tests
  7. Balasegaram M
    Ann Surg, 1972 Apr;175(4):528-34.
    PMID: 4259839
    Matched MeSH terms: Clinical Enzyme Tests
Related Terms
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links