Displaying all 2 publications

Abstract:
Sort:
  1. Baig MA, Swamy KB, Baksh AD, Bahashwan A, Moshrif Y, Al Sawat A, et al.
    Indian J Pathol Microbiol, 2021 8 4;64(3):518-523.
    PMID: 34341263 DOI: 10.4103/IJPM.IJPM_709_20
    Background: : HPLC is one of the most important tools for accurate diagnosis of hemoglobinopathies and thalassemias. The advantage of the HPLC system is the excellent resolution, reproducibility &quantification of several normal and abnormal hemoglobin.

    Results: BIO RAD Variant II analyzer was used. Sickle cell syndromes including double heterozygous states accounted for 56.13% of total cases. HbSS, HbS/β0-th, HbS/β+-th β-thal trait comprises 29%, 6.5%, 5.1%& 10% of total cases respectively with mean MCV (fl) = 84, 68,71,64 respectively. The Mean HbA2 for β-thal trait, HbE trait &HbE-β thal showed 5.1 ± 1.1, 19 ± 9 & 24 ± 8 respectively. HbF is increased in 8.6% case (excluding SC syndromes & β-thal disorders), of these 5.5% were infants & 12 cases of Aplastic Anemias. Peak P2 >7% (2.4% cases) was seen in uncontrolled diabetes mellitus which on quantification showed HbA1C = 8 ± 2.1 mmol/L.

    Discussion: : HPLC in correlation with CBC parameters & family studies can aid in the diagnosis of majority of Hemoglobinopathies and thalassemic syndrome. The CBC & HPLC parameters of the present study are in good correlation with the research conducted by Tejinder Sing, RiouJ & Alla Joutovsky. Present study showed HPLC comprehensively characterizing HbS, A, A2, F, S, C, D from each other & was also applicable for the quantification of HbA1c for the monitoring of Diabetes Mellitus.

    Conclusion: : The merits of HPLC are small quantity of sample required, economical, less TAT, accurate categorization of HbS, HbA2 & F. But one has to be aware of the limitations and problems associated with this method due to variant hemoglobin within the same retention windows. The present findings show HPLC as an excellent & powerful diagnostic tool for the direct identification of hemoglobin variants with a high degree of precision in the quantification of normal and abnormal hemoglobin fractions.

    Matched MeSH terms: Chromatography, High Pressure Liquid/standards*
  2. Shehzadi N, Hussain K, Khan MT, Salman M, Islam M
    Pak J Pharm Sci, 2017 Sep;30(5):1767-1777.
    PMID: 29084700
    The absence of chromophore and/or conjugated system, prerequisite for UV and florescent light detection, or absorbance at very low wavelength necessitates the development of simple and reliable methods for the determination of amikacin sulphate. Therefore, the present study describes for the first time dynamics of the drug derivatization using ninhydrin reagent and development and validation of a simple RP-HPLC method, using diode array detector (DAD). The variables such as heating time, heating type, drug-reagent ratio, reagent composition and storage temperature of the derivative were optimized. The analyte and aqueous ninhydrin solution upon heating for 2.00-5.00 min produced the colored drug-derivative which was stable for one month at refrigeration. The derivatized drug (20.00μL) was eluted through a column - Eclipse DB-C18 (5.00 µm, 4.60×150.00 mm), maintained at 25°C- using isocratic mobile phase comprising water and acetonitrile (70:30, v/v) at a flow rate of 1.00 mL/min, and detected at 400 nm. The method was found to be reliable (98.08-100.72% recovery), repeatable (98.02-100.72% intraday accuracy) and reproducible (98.47-101.27% inter day accuracy) with relative standard deviation less than 5%. The results of the present study indicate that the method is easy to perform, specific and sensitive, and suitable to be used for the determination of amikacin sulphate in bulk and pharmaceutical preparations using less expensive/laborious derivatization.
    Matched MeSH terms: Chromatography, High Pressure Liquid/standards
Related Terms
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links